Back to Authors

Morrow, Duane A.

Mayo Clinic

Mayo Clinic

Citations 14

An Ultraminiature MEMS Pressure Sensor With High Sensitivity for Measurement of Intramuscular Pressure (IMP) in Patients With Neuromuscular Diseases
Sezen, Serdar , Rajamani, Rajesh , Morrow, Duane A., Kaufman, Kenton R. , Gilbert, Barry K., Kaufman, Kenton R

Journal of Medical Devices | September 3, 2009 | Volume: 3 | Issue: 3 | Pages: No page available

10.1115/1.3192103 Get It

An ultraminiature micropressure sensor to accurately measure intramuscular pressure has been developed. The MEMS sensor is fabricated through surface micromachining and consists of a capacitive array of eight 150 μm diameter sensing membranes connected in parallel. The membranes have been vacuum-sealed via a subsequent deposition and patterning batch microfabrication step. A deep reactive ion etcher (DRIE) based postfabrication self-release has been utilized to fabricate individual devices. Each device has an outline that incorporates specially designed “anchor” structures that are utilized to attach on the muscle tissue during measurements to minimize the effect of muscle contractions on sensor readings. Electrical isolation of the wire bonds and bonding pads has been accomplished by utilizing glob-topping technique. The fabricated sensor performance has been experimentally validated inside a pressure chamber. The current sensors have 0.2 mm Hg pressure resolution in the ±19 mm Hg dynamic range with negligible hysteresis and show a flat frequency response in the 0–5.5 Hz experimental test range.
Intraneural ganglia: a clinical problem deserving a mechanistic explanation and model
Elangovan, Shreehari, Odegard, Gregory M. , Morrow, Duane A., Wang, Huan , Hébert-Blouin, Marie-Noëlle, Spinner, Robert J. , Hébert‐Blouin, Marie‐Noëlle

Neurosurgical Focus | January 30, 2009 | Volume: 26 | Issue: 2 | Pages: E11

10.3171/foc.2009.26.2.e11 Get It

Intraneural ganglion cysts have been considered a curiosity for 2 centuries. Based on a unifying articular (synovial) theory, recent evidence has provided a logical explanation for their formation and propagation. The fundamental principle is that of a joint origin and a capsular defect through which synovial fluid escapes following the articular branch, typically into the parent nerve. A stereotypical, reproducible appearance has been characterized that suggests a shared pathogenesis. In the present report the authors will provide a mechanistic explanation that can then be mathematically tested using a preliminary model created by finite element analysis.
Constitutive Modeling of Skeletal Muscle Tissue With an Explicit Strain-Energy Function
Odegard, Gregory M. , Donahue, Tammy L. Haut , Morrow, Duane A., Kaufman, Kenton R. , Kaufman, Kenton R

Journal of Biomechanical Engineering | November 11, 2008 | Volume: 130 | Issue: 6 | Pages: No page available

10.1115/1.3002766 Get It

While much work has previously been done in the modeling of skeletal muscle, no model has, to date, been developed that describes the mechanical behavior with an explicit strain-energy function associated with the active response of skeletal muscle tissue. A model is presented herein that has been developed to accommodate this design consideration using a robust dynamical approach. The model shows excellent agreement with a previously published model of both the active and passive length-tension properties of skeletal muscle.
IN VIVO LOCATION OF JOINT CENTERS OF THE SHOULDER SYSTEM: GLENO-HUMERAL AND SCAPULO-THORACIC JOINTS BETWEEN TWO POSTURES DESCRIBING THE ARM ELEVATION IN THE PLANE OF SCAPULA USING TECHNIQUES BASED UPON BIPLANAR RADIOGRAPHY
Berthonnaud, Éric , Herzberg, Guillaume , Morrow, Duane A., An, Kai‐Nan, Dimnet, J.

Journal of Mechanics in Medicine and Biology | January 8, 2007 | Volume: 06 | Issue: 04 | Pages: 385-397

10.1142/s0219519406002060 Get It

In biomechanics, the knowledge of accurate location of a joint center is essential because equilibration of the external loads and muscular forces about the joint is performed about this specific point. This paper focuses on the location of centers of gleno-humeral joint and scapulo-thoracic joint in a subject moving their arm in the scapular plane with a magnitude of 120°. Biplanar radiography with successive exposures has been used locating anatomical axes of bones. Geometric models of bones were defined allowing access to bone morphology by superposing model projections onto X-ray imaged bone contours. Functional models were used so as to represent the behavior in motion of shoulder joints. These techniques allowed us to access to results describing the linear and angular relative displacements of the shoulder bones between two different postures. The gleno-humeral and scapulo-thoracic finite joint centers (F H and F S ) are first defined through the location of the corresponding helical axis of motion (HAM) moving the joint from positions occupied in initial and final postures. The gleno-humeral and scapulo-thoracic mean joint centers (M H and M S ) are then calculated using a new technique, which defines that each joint center has the point having the smallest migrations while moving continuously from initial to final postures. This allows for the analysis of the linear and angular clearances, which affect joint center migration. The whole continuous movement has been parsed into several steps to test the stability of the mean joint center throughout the motion.