Back to Authors

Morrow, Duane A.

Mayo Clinic

Mayo Clinic

Citations 14

Fluorescent Microspheres Injected into Skeletal Muscle to Observe Fluid Movement in Interstitial Space
Evertz, Loribeth Q., Greising, Sarah M. , Morrow, Duane A., Sieck, Gary C. , Kaufman, Kenton R.

The FASEB Journal | June 21, 2021 | Volume: 29 | Issue: S1 | Pages: No page available

10.1096/fasebj.29.1_supplement.lb694 Get It

The force within a muscle may be assessed using intramuscular pressure measurements (IMP). However, a limiting factor in implementing this technology in the clinic is the observed variability of IMP measurements. The variability may be due in part to the flow of interstitial fluid. The objective of this study was to develop a technique for tracking interstitial fluid flow during muscle lengthening using fluorescent microspheres. Additionally, the effect of microsphere diameter on dispersion was evaluated. Fluorescent microspheres were injected into the rat tibialis anterior (TA) either before (right limb) or after (left limb) lengthening to 10% strain (n = 5). To help discriminate the effects of microsphere size, 10 µl of microspheres (0.25% by volume) were injected simultaneously: 0.1 µm in sky blue and 0.2 µm in yellow green. Once frozen, 20 µm muscle cross‐sections were stained and imaged using confocal microscopy to evaluate the microsphere's axial dispersion as a percent of muscle length. The microsphere dispersion was normalized to the muscle length. The fluorescent microspheres flowed with the interstitial fluid and did not penetrate the muscle fiber. There was significantly greater microsphere dispersion with passive strain (p‐value > 0.01) for lengthened samples (31±7%) compared to static samples (17±9%). Dispersion did not differ for the two bead sizes. In conclusion, this illustrates the microspheres track the interstitial fluid and passive lengthening results in additional dispersion. Supported by NIH under award number R01HD31476 and T32HL105355.
Analysis of fluid movement in skeletal muscle using fluorescent microspheres
Evertz, Loribeth Q., Greising, Sarah M. , Morrow, Duane A., Sieck, Gary C. , Kaufman, Kenton R. , Sieck, Gary , Kaufman, Kenton R

Muscle & Nerve | February 2, 2016 | Volume: 54 | Issue: 3 | Pages: 444-450

10.1002/mus.25063 Get It

ABSTRACTIntroductionRegional variability in interstitial fluid pressure confounds use of intramuscular pressure measurement to assess muscle force. It is hypothesized that interstitial flow is dependent on intramuscular pressure. The goal of this study was to assess the feasibility of using fluorescent microspheres to evaluate movement of interstitial fluid in skeletal muscle.MethodsTwo diameters of fluorescent microspheres were injected into the rat tibialis anterior during both static (n = 6) and passively lengthened (10% strain) experimental conditions (n = 6). Microsphere dispersion was evaluated using confocal imaging of transverse muscle sections.ResultsFluorescent microspheres tracked interstitial fluid while not penetrating the muscle fiber. When compared with the static condition, significantly greater dispersion (P = 0.003) was seen with passively lengthened conditions (17 ± 9% vs. 31 ± 7%, respectively). Dispersion did not differ for the 2 microsphere sizes (P = 0.811).ConclusionsFluorescent microspheres track movement of interstitial fluid, and dispersion is dependent on passive lengthening. Muscle Nerve 54: 444–450, 2016
Tensile Material Properties of Skeletal Muscle Tissue in Longitudinal and Transverse Directions
Morrow, Duane A., Donahue, Tammy L. Haut , Odegard, Gregory M. , Kaufman, Kenton R.

ASME 2008 Summer Bioengineering Conference, Parts A and B | March 13, 2014 | Volume: No volume available | Issue: No issue available | Pages: 1027-1028

10.1115/sbc2008-193043 Get It

Since Blix noted that force varies with muscle length [1], many investigators have worked to characterize the passive length-tension properties of skeletal muscle in the tissue’s fiber direction [2]. However, few reports have examined the properties of muscle in either transverse extension or in longitudinal shear [3–4]. Material properties in these three directions are needed to fully characterize computational models, which generally describe muscle as being transversely isotropic, hyperelastic, and isovolumetric [3–6]. Further, previous studies reporting tri-planar material properties indicate that muscle tissue is stiffer in the transverse direction compared to the longitudinal direction [3–4]. This counters conventional notions of transversely isotropic materials, which are generally stiffer in the fiber direction.
Constitutive Modeling of Skeletal Muscle Tissue
Donahue, Tammy L. Haut , Morrow, Duane A., Odegard, Gregory M. , Kaufman, Kenton R.

ASME 2007 Summer Bioengineering Conference | March 12, 2014 | Volume: No volume available | Issue: No issue available | Pages: 873-874

10.1115/sbc2007-175848 Get It

The main functions of the human musculoskeletal system are to sustain loads and provide mobility. Bones and joints themselves cannot produce movement; skeletal muscles provide the ability to move. Knowledge of muscle forces during given activities can provide insight into muscle mechanics, muscle physiology, musculoskeletal mechanics, neurophysiology, and motor control. However, clinical examinations or instrumented strength testing only provides information regarding muscle groups. Musculoskeletal models are typically needed to calculate individual muscle forces.
Validation of a Finite Element Model of Passive Force and Pressure in Skeletal Muscle
Morrow, Duane A., Donahue, Tammy L. Haut , Odegard, Gregory M. , Kaufman, Kenton R. , Kaufman, Kenton R

ASME 2009 Summer Bioengineering Conference, Parts A and B | July 19, 2013 | Volume: No volume available | Issue: No issue available | Pages: 339-340

10.1115/sbc2009-206211 Get It

Intramuscular pressure (IMP) has been put forth as a surrogate measure for muscle force. As technological advancements have lead to the creation of smaller IMP microsensors, obtaining IMP readings in the clinic has come closer to becoming a minimally-invasive reality. However, appropriate use of data from these sensors relies upon an understanding of the mechanism of pressure changes within skeletal muscle. To that end, a constitutive model, representing muscle as a transversely isotropic, hyperelastic, and isovolumetric was created [1] for implementation in a finite element simulation. The purpose of this study was to validate this constitutive muscle model with passive elongation tests of skeletal muscle tissue from New Zealand White (NZW) rabbits. Reaction forces and hydrostatic pressures resulting from applied deformations were determined with the finite element modeling (FEM) approach and were compared with previously published experimental data [2].
A Poroelastic Model of Skeletal Muscle Tissue Used to Predict Intramuscular Pressure
Morrow, Duane A., Donahue, Tammy L. Haut , Odegard, Gregory M. , Kaufman, Kenton R. , Kaufman, Kenton R

ASME 2012 Summer Bioengineering Conference, Parts A and B | July 19, 2013 | Volume: No volume available | Issue: No issue available | Pages: 719-720

10.1115/sbc2012-80346 Get It

Many single-phase, solid mechanics computational models of skeletal muscle have been created based on the assumptions that skeletal muscle is hyperelastic, transversely isotropic,1,2 and isovolumic. However, muscle has also been observed to have non-linear time-dependent behaviors that can be modeled using viscoelasticity or poroelasticity. The inherent viscoelasticity of muscle may not fully explain the time-dependent nature that may arise from extracellular fluid filtration3 and redistribution4 within the tissue. Further, intramuscular pressure (IMP) has been shown to have a heterogeneous distribution in muscle. This may be attributable to the movement of extracellular fluid, but the mechanisms of fluid redistribution are not completely understood. While a viscoelastic model may predict time-dependent responses of skeletal muscle, viscoelastic theory does not explain underlying causative tissue behaviors.5
Internal Pressure in Human Meniscal Attachments Subjected to Physiological Loading
Miller, Emily J. , Morrow, Duane A., Kaufman, Kenton R. , Donahue, Tammy L. Haut , Villegas, Diego F. , Kaufman, Kenton R

ASME 2009 Summer Bioengineering Conference, Parts A and B | July 19, 2013 | Volume: No volume available | Issue: No issue available | Pages: 705-706

10.1115/sbc2009-206363 Get It

Meniscal attachments serve to anchor and transfer loads from menisci to the tibia. These ligamentous tissues are composed of collagen fibers, elastin, ground substance and water. Ligaments have a time- and history-dependent viscoelastic behavior due in part to the interaction of the water and the ground substance [1]. The movement of water within ligamentous tissue is limited because of charged proteoglycan molecules. It has been shown that some exudation of water is present during cyclic loading of ligamentous tissue [2]. The movement and its inhibition could lead to changes of pressure within the meniscal attachments. Therefore, the purpose of this study was to quantify the internal pressure in human meniscal attachments subjected to physiological loading. Since it is thought that the posterior attachment is subjected to both tension and compression, while the anterior attachment is primarily subjected to tension [3–5], we hypothesized that the attachments mechanical environment is dictated by the external loads, and hence, the posterior attachment would elicit higher pressures.
A Validated Finite Element Model of Force in Active and Passive Skeletal Muscle
Morrow, Duane A., Donahue, Tammy L. Haut , Odegard, Gregory M. , Kaufman, Kenton R. , Kaufman, Kenton R

ASME 2010 Summer Bioengineering Conference, Parts A and B | July 15, 2013 | Volume: No volume available | Issue: No issue available | Pages: 175-176

10.1115/sbc2010-19385 Get It

A fully 3D, continuum mechanics based model of skeletal muscle, validated against experimental force data, can be used to computationally solve for individual muscle forces. A constitutive formulation, representing muscle as a transversely isotropic, hyperelastic, and isovolumetric material [1] has been implemented in a finite element model (FEM) of passive skeletal muscle and validated against experimental tension measurements [2]. Of further interest is an expanded formulation that will allow for the addition of muscle activation levels on the overall skeletal muscle force generation. The purpose of this study was to expand the FEA model to include muscle activation and validate it with tests of active skeletal muscle tissue at varied lengths.
Use of a Poroelastic Model to Predict Intramuscular Pressure
Morrow, Duane A., Odegard, Gregory M. , Kaufman, Kenton R. , Kaufman, Kenton R

Poromechanics V | June 21, 2013 | Volume: No volume available | Issue: No issue available | Pages: 2174-2183

10.1061/9780784412992.256 Get It

Surgical therapy for tremor in multiple sclerosis
Matsumoto, Joseph Y., Morrow, Duane A., Davis, D.H., Ahlskog, J. Eric , Walker, A. , Sneve, D., Noseworthy, John H., Kaufman, Kenton R. , Rodriguez, Moses

Neurology | May 13, 2012 | Volume: 57 | Issue: 10 | Pages: 1876-1882

10.1212/wnl.57.10.1876 Get It