Quantitative computed tomography-based finite-element analysis (QCT/FEA) has become increasingly popular in an attempt to understand and possibly reduce vertebral fracture risk. It is known that scanning acquisition settings affect Hounsfield units (HU) of the CT voxels. Material properties assignments in QCT/FEA, relating HU to Young's modulus, are performed by applying empirical equations. The purpose of this study was to evaluate the effect of QCT scanning protocols on predicted stiffness values from finite-element models. One fresh frozen cadaveric torso and a QCT calibration phantom were scanned six times varying voltage and current and reconstructed to obtain a total of 12 sets of images. Five vertebrae from the torso were experimentally tested to obtain stiffness values. QCT/FEA models of the five vertebrae were developed for the 12 image data resulting in a total of 60 models. Predicted stiffness was compared to the experimental values. The highest percent difference in stiffness was approximately 480% (80 kVp, 110 mAs, U70), while the lowest outcome was ∼1% (80 kVp, 110 mAs, U30). There was a clear distinction between reconstruction kernels in predicted outcomes, whereas voltage did not present a clear influence on results. The potential of QCT/FEA as an improvement to conventional fracture risk prediction tools is well established. However, it is important to establish research protocols that can lead to results that can be translated to the clinical setting.
Comparison of Passive Stiffness Changes in the Supraspinatus Muscle After Double‐Row and Knotless Transosseous‐Equivalent Rotator Cuff Repair Techniques: A Cadaveric Study
Purpose To investigate the alteration of passive stiffness in the supraspinatus muscle after double‐row (DR) and knotless transosseous‐equivalent (KL‐TOE) repair techniques, using shear wave elastography (SWE) in cadavers with rotator cuff tears. We also aimed to compare altered muscular stiffness after these repairs to that obtained from shoulders with intact rotator cuff tendon. Methods Twelve fresh‐frozen cadaveric shoulders with rotator cuff tear (tear size: small [6], medium‐large [6]) were used. Passive stiffness of 4 anatomic regions in the supraspinatus muscle was measured based on an established SWE method. Each specimen underwent DR and KL‐TOE footprint repairs at 30° glenohumeral abduction. SWE values, obtained at 0°, 10°, 20°, 30°, 60°, and 90° abduction, were assessed in 3 different conditions: preoperative (torn) and postoperative conditions with the 2 techniques. The increased ratio of SWE values after repair was compared among the 4 regions to assess stiffness distribution. In addition, SWE values were obtained on 12 shoulders with intact rotator cuff tendons as control. Results In shoulders with medium‐large‐sized tears, supraspinatus muscles showed an increased passive stiffness after rotator cuff repairs, and this was significantly observed at adducted positions. KL‐TOE repair showed uniform stiffness changes among the 4 regions of the supraspinatus muscle (mean, 189% to 218% increase after repair), whereas DR repair caused a significantly heterogeneous stiffness distribution within the muscle (mean, 187% to 319% after repair, P = .002). Although a repair‐induced increase in muscle stiffness was observed also in small‐sized tears, there were no significant differences in repaired stiffness changes between DR and KL‐TOE (mean, 127% to 138% and 127% to 130% after repairs, respectively). Shoulders with intact rotator cuff tendon showed uniform SWE values among the 4 regions of the supraspinatus muscle (mean, 38.2 to 43.0 kPa). Conclusions Passive stiffness of the supraspinatus muscle increases after rotator cuff repairs for medium‐large‐sized tears. KL‐TOE technique for the medium‐large‐sized tear provided a more uniform stiffness distribution across the repaired supraspinatus muscles compared with the DR technique. Clinical Relevance Based on this insight, investigating rotator cuff muscle stiffness changes, further studies using SWE may determine the optimal repair technique for various sizes of rotator cuff tears.
THE EFFECT OF FREEZING ON BIOMECHANICAL PROPERTIES OF THE CARPAL TUNNEL SUBSYNOVIAL CONNECTIVE TISSUE
Biomechanical evaluation of the subsynovial connective tissue (SSCT) provides insight into the causes of carpal tunnel syndrome. Studies of carpal tunnel mechanics have been performed using fresh-frozen cadaver tissue. Freezing can affect mechanical properties of some tissues, but its effect on SSCT is unknown. A total of 16 rabbit paws were harvested from eight New Zealand rabbits and subjected to mechanical testing consisting of three repeated tendon excursions in sets of three different excursion magnitudes. One paw from each animal was unfrozen. The contralateral paw was frozen and thawed before testing. Force, energy and stiffness of the first cycle of each set were evaluated, as were ratios of the second to first cycle for each parameter. Two-factor ANOVA with repeated measures over both factors was performed. No significant interactions between factors were found. There were no significant differences between fresh and frozen paws for any parameters, though there were significant differences between excursion amplitudes. The damage threshold was not different between fresh and frozen paws. This study demonstrated that freezing rabbit subsynovial connective tissue does not significantly change its mechanical properties. The same may be true for human cadaver tissues. Results of cadaver mechanical testing may not be influenced by this preservation technique.
Effects of lubricant and autologous bone marrow stromal cell augmentation on immobilized flexor tendon repairs