Back to Authors

Tokavanich, Nithi

https://orcid.org/0000-0003-1846-3786

Mayo Clinic

University of Michigan

Citations 17

QRS area as a predictor of cardiac resynchronization therapy response: A systematic review and meta‐analysis
Tokavanich, Nithi , Prasitlumkum, Narut , Mongkonsritragoon, Wimwipa , Trongtorsak, Angkawipa , Cheungpasitporn, Wisit , Cheungpasitporn, Wisit , Prasitlumkum, Narut , Chokesuwattanaskul, Ronpichai

Pacing and Clinical Electrophysiology | January 9, 2022 | Volume: 45 | Issue: 3 | Pages: 393-400

10.1111/pace.14441 Get It

AbstractBackgroundQRS area, a three‐dimensional QRS complex, is a novel vectorcardiography method of measuring the magnitude of electrical forces in the heart. Hypothetically, a greater QRS area denotes higher dyssynchrony and indicates potential benefits from cardiac resynchronization therapy (CRT). Previous studies suggest a positive correlation between QRS area and the degree of response to CRT, but its clinical use remains unclear. We performed a meta‐analysis of the relationship between QRS area and survival benefit following CRT.MethodsWe comprehensively searched the MEDLINE, EMBASE, and Cochrane databases from inception to August 2021. We included studies with prospective and retrospective cohort designs that reported QRS area before CRT and total mortality. Data from each study were analyzed using a random‐effects model. The results were reported as a hazard ratio (HR) and 95% confidence intervals.ResultsFive observational studies including 4931 patients were identified. The cut‐off values between large and small QRS areas ranged from 102 to 116 μVs. Our analysis showed a larger QRS area was statistically associated with increased 5‐year survival in patients implanted with CRT (HR pooled 0.48, 95% CI 0.46–0.51, I2 = 54%, p < .0001). Greater QRS area reduction (pre‐ and post‐implantation) were associated with a lower total mortality rate (HR pooled 0.45, 95% CI 0.38–0.52, I2 = 0%, p < .0001).ConclusionLarger pre‐implantation QRS area was associated with increased survival after CRT. QRS area reduction following CRT implantation was also associated with lower mortality. QRS area may potentially become an additional selection criterion for CRT implantations.
The effect of QRS area in predicting survival benefit following cardiac resynchronization therapy: a systematic review and meta-analysis
Tokavanich, Nithi , Mongkonsritragoon, Wimwipa , Prasitlumkum, Narut , Cheungpasitporn, Wisit , Trongtorsak, Angkawipa , Chokesuwattanaskul, Ronpichai

European Heart Journal | October 20, 2021 | Volume: 42 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehab724.0702 Get It

Abstract Background QRS area, three-dimensional QRS complex, is among novel vectorcardiographical methods of measuring the magnitude of electrical forces generated by the heart. Hypothetically, greater QRS area portrayed higher dyssynchronous electrical activation, possibly deriving significant cardiac resynchronization therapy (CRT) benefit. Previous studies suggested a positive correlation between QRS areas and the degree of CRT responses. Nevertheless, its clinical use has remained premature. We hence performed a systematic review and meta-analysis of QRS area in predicting survival benefit following CRT. Method We comprehensively searched the databases of MEDLINE, EMBASE, and Cochrane database from inception to March 2021. Included studies with prospective and retrospective cohort design. Studies those report QRS area before implantation of CRT and outcome of total mortality. Data of each study were combined with random effects model. The results were reported in hazard ration (HR) with 95% confidence intervals. Result Four observational studies, including 4,931 patients, were identified. The cut-off values between large and small QRS areas ranged from 102–116 μVs. Our analysis showed larger QRS area was statistically associated with survival benefit in patients implanted with CRT with follow up time up to 5 years (Pooled hazard ratio 0.46, 95% confident interval 0.38–0.55, I2=42%). More QRS areas changes (pre and post implantation) were associated with lower total mortality rate (Pooled hazard ratio 0.45, 95% confident interval 0.38–0.52, I2=0%). Conclusion Patients with pre-implantation larger QRS area were strongly associated with survival benefit after CRT implantation. QRS area may potentially become additional selection criteria for CRT implantation. Funding Acknowledgement Type of funding sources: None. Figure 1. Forest plot of pooled hazard ratioTable 1. Study characteristics
Comparison between same‐day discharge and overnight stay after atrial fibrillation ablation: Systematic review and meta‐analysis
Prasitlumkum, Narut , Cheungpasitporn, Wisit , Chokesuwattanaskul, Ronpichai , Kewcharoen, Jakrin , Tokavanich, Nithi , Navaravong, Leenhapong , Jongnarangsin, Krit, Cheungpasitporn, Wisit , Chokesuwattanaskul, Ronpichai , Kewcharoen, Jakrin , Navaravong, Leenhapong , Prasitlumkum, Narut

Pacing and Clinical Electrophysiology | October 19, 2021 | Volume: 44 | Issue: 12 | Pages: 2054-2066

10.1111/pace.14380 Get It

AbstractBackgroundIn the modern era, atrial fibrillation (AF) ablation trend has been shifted toward same‐day discharge (SDD), from a traditional overnight stay. Yet, recent studies have not well stated the safety profiles which remained poor‐understood and dispersed. We hence performed systematic review and meta‐analysis to assess the adverse outcomes of SDD in comparison with an overnight stay.MethodsDatabases were searched through January 2021. Effect estimates from the individual studies were extracted and combined using random‐effects, generic inverse variance method of der Simonian and Laird. The primary outcomes included total cumulative complications and immediate complications following AF ablation.ResultsTen observational studies were met our inclusion criteria, comprising of total population of 11,660 patients, with SDD 51.3%. For total cumulative complications, there were no differences observed between SDD and overnight stay (5.2% vs. 6.2%: pooled OR 0.77: 95% CI 0.55–1.08, p = .13 with I2 = 27.1%). In addition, comparable immediate complications were also demonstrated (5.2 % vs. 4.3: pooled OR 1.08: 95% CI 0.72–1.62, p = .718, with I2 = 37.3 %).ConclusionOur study suggested that SDD had similar complication rates, both total cumulative and immediate outcomes, compared with overnight stay in selected patients following AF ablation. Nevertheless, randomized control trials are warranted to validate the findings.
Benefit of Atrial Overdrive Pacing in Patients with Sleep Apnea: A Meta-Analysis
Tokavanich, Nithi , Leelapatana, Pattranee , Prechawat, Somchai, Rungpradubvong, Voravut , Mongkonsritrakoon, Wimwipa, Vallabhajosyula, Saraschandra , Cheungpasitporn, Wisit , Chokesuwattanaskul, Ronpichai , Cheungpasitporn, Wisit , Chokesuwattanaskul, Ronpichai , Vallabhajosyula, Saraschandra , Prasitlumkum, Narut , Thongprayoon, Charat

Journal of Clinical Medicine | September 9, 2021 | Volume: 10 | Issue: 18 | Pages: 4065

10.3390/jcm10184065 Get It

Background: Sleep apnea is one of the most common conditions around the world. This disorder can significantly impact cardiovascular morbidity and mortality. Atrial overdrive pacing (AOP) is a treatment modality that can potentially decrease respiratory events. There is currently a lack of evidence to confirm the benefits of AOP. We aimed to assess the impact of AOP in patients with obstructive sleep apnea (OSA), central sleep apnea (CSA), and mixed type. Methods: A literature search for studies that reported the impact on apnea–hypopnea index (AHI) by cardiac implantable electronic devices with different pacing modes was conducted using MEDLINE, Embase, and Cochrane Database from inception through July 2020. Pooled standard mean difference with 95%CI was calculated using a random-effects model. Results: Fifteen studies, including thirteen randomized studies and two observational studies containing 440 patients, were identified. The standard mean difference in apnea–hypopnea index of atrial overdrive pacing demonstrated less duration of apnea/hypopnea in patients with atrial overdrive pacing (AOP) (SMD −0.29, 95%CI: −0.48, −0.10, I2 = 57%). Additional analysis was performed to assess the effect of atrial overdrive pacing in patients with or without severe sleep apnea syndrome (mean AHI < 30 defined as non-severe). There was no statistically significant difference in standardized mean in AHI in both subgroups between AOP and control groups (SMD −0.25, severe sleep apnea syndrome SMD −0.03, I2 = 0.00%). Conclusions: AOP was associated with a statistically significant reduction in AHI, but the magnitude of reduction was small. AOP may potentially be used as an adjunctive treatment with other modalities in treating patients with sleep apnea.
Antidepressants and Risk of Sudden Cardiac Death: A Network Meta-Analysis and Systematic Review
Cheungpasitporn, Wisit , Tokavanich, Nithi , Ding, Kimberly R., Kaewput, Wisit , Chokesuwattanaskul, Ronpichai , Cheungpasitporn, Wisit , Ding, Kimberly R , Kaewput, Wisit , Chokesuwattanaskul, Ronpichai , Prasitlumkum, Narut , Kewcharoen, Jakrin , Thongprayoon, Charat , Vallabhajosyula, Saraschandra

Medical Sciences | April 25, 2021 | Volume: 9 | Issue: 2 | Pages: 26

10.3390/medsci9020026 Get It

Background: Antidepressants are one of the most prescribed medications, particularly for patients with mental disorders. Nevertheless, there are still limited data regarding the risk of ventricular arrhythmia (VA) and sudden cardiac death (SCD) associated with these medications. Thus, we performed systemic review and meta-analysis to characterize the risks of VA and SCD among patients who used common antidepressants. Methods: A literature search for studies that reported risk of ventricular arrhythmias and sudden cardiac death in antidepressant use from MEDLINE, EMBASE, and Cochrane Database from inception through September 2020. A random-effects model network meta-analysis model was used to analyze the relation between antidepressants and VA/SCD. Surface Under Cumulative Ranking Curve (SUCRA) was used to rank the treatment for each outcome. Results: The mean study sample size was 355,158 subjects. Tricyclic antidepressant (TCA) patients were the least likely to develop ventricular arrhythmia events/sudden cardiac deaths at OR 0.24, 0.028–1.2, OR 0.32 (95% CI 0.038–1.6) for serotonin and norepinephrine reuptake inhibitors (SNRI), and OR 0.36 (95% CI 0.043, 1.8) for selective serotonin reuptake inhibitors (SSRI), respectively. According to SUCRA analysis, TCA was on a higher rank compared to SNRI and SSRI considering the risk of VA/SCD. Conclusion: Our network meta-analysis demonstrated the low risk of VA/SCD among patients using antidepressants for SNRI, SSRI and especially, TCA. Despite the relatively lowest VA/SCD in TCA, drug efficacy and other adverse effects should be taken into account in patients with mental disorders.
A Network Meta-analysis and Systematic Review of Left Bundle Branch Pacing, His Bundle Pacing, Biventricular Pacing or RV Pacing in Patients Requiring Permanent Pacemaker
Tokavanich, Nithi , Mongkonsritragoon, Wimwipa , Cheungpasitporn, Wisit , Cheungpasitporn, Wisit , Prasitlumkum, Narut , Thongprayoon, Charat , Vallabhajosyula, Saraschandra , Chokesuwattanaskul, Ronpichai

No container title available | February 12, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-185029/v1 Get It

Abstract Background: Cardiac dyssynchronization is the proposed mechanism for pacemaker-induced cardiomyopathy. The standard of treatment is biventricular pacing. Left bundle branch pacing and His bundle pacing are novel interventions that imitate the natural conductionof the heart with, theoretically, less interventricular dysynchrony. One of the surrogate markers of interventricular synchrony is QRS duration. Our study aimed to compare the change of QRS duration before and after implantation between types of cardiac implantable electronic device (CIED): left bundle branch pacing versus His bundle pacing versus biventricular pacing and conventional right ventricular pacing. Methods: A literature search for studies that reported an interval change of QRS duration after CIED implantation was conducted utilizing the MEDLINE, EMBASE, and Cochrane databases. All relevant work through September 2020 from these databases was included in this analysis. A random-effects model network meta-analysis was used to analyze QRS duration changes (i.e., electrical cardiac synchronization) across different CIED implantations. Results: The mean study sample size, from 16 included studies, was 185 subjects. According to SUCRA analysis for the studies analyzed, the His bundle pacing intervention resulted in the most dramatic decline in QRS duration (mean difference -53 ms, 95% CI -67, -39), followed by left bundle branch pacing (mean difference -46 ms, 95% CI -60, -33) and biventricular pacing (mean difference -19 ms, 95% CI -37, -1.8), when compared to conventional right ventricle apical lead placement. Conclusion: Our network meta-analysis found that His bundle branch pacing devices have the greatest effect on QRS duration reduction after implantation, followed by left bundle branch pacing. Physiologic pacing interventions result in improved electrocardiography markers of cardiac synchronicity, narrower QRS duration, and might lower electromechanical dyssynchrony.
Baseline significant tricuspid regurgitation is associated with higher mortality in transcatheter aortic valve replacement: systemic review and meta-analysis
Kittipibul, Veraprapas , Tokavanich, Nithi , Rattanawong, Pattara , Angsubhakorn, Natthapon , Gillaspie, Erin A. , Cheungpasitporn, Wisit , Cheungpasitporn, Wisit , Rattanawong, Pattara , Prasitlumkum, Narut , Kewcharoen, Jakrin , Mao, Michael A.

Journal of Cardiovascular Medicine | May 6, 2019 | Volume: 20 | Issue: 7 | Pages: 477-486

10.2459/jcm.0000000000000807 Get It

Introduction Significant tricuspid regurgitation is a well recognized indicator of right ventricular dysfunction. Recent studies have shown that significant tricuspid regurgitation is potentially associated with increased mortality in patients with severe aortic stenosis who underwent transcatheter aortic valve replacement (TAVR). However, data remained sparse and inconclusive. Thus, we performed a systematic review and meta-analysis of the literature to assess the association between significant tricuspid regurgitation and mortality in post TAVR patients. Hypothesis Significant tricuspid regurgitation is predictive for higher mortality in patients undergoing TAVR. Methods We comprehensively searched the databases of MEDLINE and EMBASE from inception to October 2018. Included studies were published observational studies that reported multivariate analysis of the effects of significant tricuspid regurgitation on all-cause mortality among patients undergoing TAVR. Data from each study were combined utilizing the random-effects, generic inverse variance method of DerSimonian and Laird to calculate odds ratios (ORs) and 95% confidence intervals (CIs). Results Nine cohort studies from August 2011 to May 2018 consisting of 27 614 patients with severe aortic stenosis undergoing TAVR (6255 with and 21 359 without significant tricuspid regurgitation) were included in this meta-analysis. The presence of significant tricuspid regurgitation was associated with higher all-cause mortality (pooled OR = 2.26, 95% CI: 1.45–3.52, P < 0.001). We found that all-cause mortality remained statistically substantial in all subgroups (30-day all-cause mortality: OR = 2.05, 95% CI: 1.20–3.49, P = 0.009; midterm all-cause mortality: OR = 9.67, 95% CI: 2.44–38.31, P = 0.001; and long-term all-cause mortality: OR = 1.48, 95% CI: 1.19–1.85, P < 0.001). Funnel plots and Egger's regression asymmetry test were performed and showed no publication bias. Conclusion Significant tricuspid regurgitation increased risk of mortality by up to two-fold among patients with severe aortic stenosis undergoing TAVR. Our study suggests that significant tricuspid regurgitation should be considered a component of risk stratification tools.