Back to Authors

Karataylι-Özgürsoy, Selmin

Mayo Clinic

Mayo Clinic in Florida

Citations 3

Effect of Partial Uncinectomy After Balloon Sinuplasty on Maxillary Sinus Irrigant Penetration: A Cadaveric Study
Karataylι-Özgürsoy, Selmin, Gonzalez, Valeria , Olomu, Osarenoma , Donaldson, Angela M. , Martinez-Paredes, Jhon F, Karatayli-Ozgursoy, Selmin, Gonzalez, Valeria V , Martinez‐Paredes, Jhon F.

OTO Open | January 27, 2021 | Volume: 5 | Issue: 1 | Pages: No page available

10.1177/2473974x21989583 Get It

ObjectiveThe uncinate process may play a role in the amount of irrigation penetrance. In this cadaver study, we aimed to investigate if the addition of partial uncinectomy provides better maxillary sinus irrigation penetrance than balloon sinuplasty (BSP) alone.Study DesignCadaveric study.SettingSimulation laboratory at the Mayo Clinic in Florida.MethodsFive fresh‐frozen human cadaveric heads (10 sides) were used to assess maxillary sinus irrigation penetration after 3 interventions performed sequentially: irrigation penetrance with no intervention, irrigation after BSP, and irrigation after BSP and partial removal of the uncinate. Penetrance was recorded with intrasinus endoscopy and scored by 4 blinded observers using a scale from 0 (no irrigation) to 5 (fully irrigated). The diameter of the maxillary ostium was measured before and after BSP. Internal consistency was evaluated with Cronbach’s alpha.ResultsMean ostium size increased from 4.1 to 6.8 mm after BSP (P =. 013). Cronbach’s alpha was 0.93. The median scores of irrigation penetration after no intervention, BSP, and BSP and partial uncinectomy were 2.5, 3, and 4, respectively. We found a significantly higher penetrance following partial uncinectomy plus BSP versus BSP alone (P =. 008). Both interventions had a statistically significant difference in irrigation penetrance as compared with no intervention (P =. 0001).ConclusionMaxillary sinus irrigation penetration increased from baseline after BSP. The addition of a partial uncinectomy to the balloon dilation of the maxillary sinus was associated with a statistically significant increase in irrigation penetrance scores as compared with BSP alone.
Bilateral Multicanal Benign Paroxysmal Positional Vertigo Coexisting with a Vestibular Schwannoma: Case Report
Karataylι-Özgürsoy, Selmin, Stamper, Greta C., Lundy, Larry, Zapala, David A.

Ear, Nose & Throat Journal | January 10, 2019 | Volume: 90 | Issue: 1 | Pages: E10-E15

10.1177/014556131109000114 Get It

We describe a rarely encountered case of coexisting bilateral multicanal benign paroxysmal positional vertigo (BPPV) and vestibular schwannoma in a 56-year-old woman. The patient had presented with a 10-year history of dizziness and imbalance, and her vestibular findings were perplexing. We decided on a working diagnosis of BPPV and began treatment. After several months of canalith repositioning maneuvers had failed to resolve her symptoms, we obtained magnetic resonance imaging, which revealed the presence of the vestibular schwannoma. This case serves as a reminder of the importance of differentiating between central and peripheral vestibular disorders, as well as central and anterior canal BPPV-induced down-beating nystagmus in order to establish the correct diagnosis and initiate appropriate treatment.
Cochlear Implant Fixation Using Resorbable Mesh
Lundy, Larry, Karataylι-Özgürsoy, Selmin

Ear, Nose & Throat Journal | January 10, 2019 | Volume: 90 | Issue: 7 | Pages: 306-312

10.1177/014556131109000707 Get It

In this article we describe a new method of cochlear implant receiver-stimulator fixation using a resorbable poly (D,L) lactic acid mesh. We conducted a retrospective case review at a tertiary referral center; 10 pediatric and 4 adult patients had undergone cochlear implantation during the period from February to October 2008. Resorbable poly (D,L) lactic acid mesh and pins were used for fixation of the cochlear implant receiver stimulator. The receiver stimulator was assessed for stability/migration, and the scalp flap/incision were evaluated for allergic reactions, infections, and healing problems. With an average followup of 17.2 months, no patients had migration of the receiver stimulator, and there was no evidence of infection, wound dehiscence, or allergic reaction. Early results indicate that fixation of a cochlear implant receiver stimulator using resorbable mesh is well tolerated and provides good stability without device migration. Resorbable mesh fixation of the receiver stimulator is a reasonable alternative technique for cochlear implantation.