Citations

Clear

17 citation(s) found for "Villablanca, Pedro".

Real-World Outcomes of Transcatheter Tricuspid Valve Replacement
Makkar, R R, Gupta, A, O’Neill, Brian P., Lalani, Christina , Sharma, Rahul P., Yadav, Pradeep, Frisoli, Tiberio M., Thourani, Vinod, Eleid, Mackram F., Lee, James, Babaliaros, Vasilis C., Haeffele, Christiane , Bajwa, Tanvir , Flueckiger, Peter, Cubeddu, Robert J., Davidson, Laura J., Padang, Ratnasari , Spinetto, Pedro Villablanca, Narang, Akhil , Williams, Mathew, Gleason, Patrick, Tang, Gilbert H. L., Khera, Sahil , Vavalle, John P., Byku, Isida , Depta, Jeremiah P., Garcia, Santiago, Kapadia, Samir, Zajarías, Alan , Chanin, Jake, Kodali, Susheel K., Herrmann, Howard C., Morse, M. Andrew, Petrossian, George , Sivak, Joseph A. , Hahn, Rebecca T., Song, Yang, Leon, M.B., Yeh, Robert W., Davidson, C, Haeffele, Christiane , Makkar, Raj , Gupta, Aakriti , O’Neill, Brian Patrick , Sharma, Rahul P., Yadav, Pradeep , Frisoli, Tiberio , Thourani, Vinod H. , Makar, Moody M. , Eleid, Mackram F. , Lee, James, Babaliaros, Vasilis , Flueckiger, Peter B. , Davidson, Laura J., Allaqaband, Suhail Q. , Williams, Mathew R., Gleason, Patrick T. , Tang, Gilbert H.L. , Vavalle, John P. , Depta, Jeremiah P , Garcia, Santiago A. , Kapadia, Samir , Kodali, Susheel , Herrmann, Howard C. , Morse, M. Andrew M. , Hahn, Rebecca T , Song, Yang, Yeh, Robert W. , Davidson, Charles J.

Mayo Clinic

JAMA | April 13, 2026 | Volume: 335 | Issue: 18 | Pages: 1606

10.1001/jama.2026.3446 | PMID 41973411 Get It

Importance Transcatheter tricuspid valve replacement (TTVR) demonstrated superior outcomes over medical therapy in patients with severe tricuspid regurgitation (TR) in the Edwards EVOQUE Transcatheter Tricuspid Valve Replacement: Pivotal Clinical Investigation of Safety and Clinical Efficacy Using a Novel Device II (TRISCEND II) randomized clinical trial, and received regulatory approval in the US in 2024. Contemporary real-world data on its effectiveness and safety remain limited. Objective To evaluate 30-day clinical, echocardiographic, and health status outcomes of TTVR in real-world use. Design, Setting, and Population Retrospective cohort study of all consecutive patients who underwent TTVR in the US from February 2024 through March 2025 in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Patients had symptomatic, severe TR despite optimal medical therapy and TTVR was deemed appropriate by a heart team. Statistical analysis was conducted from September 2025 to February 2026. Exposure Device-enabled TTVR. Main Outcomes and Measures Thirty-day event rates (all-cause death, stroke, bleeding, new cardiac implantable electronic device [CIED] implantation, heart failure hospitalizations), TR reduction, and changes in health status (New York Heart Association [NYHA] functional class and Kansas City Cardiomyopathy Questionnaire Overall Summary [KCCQ-OS] score) are reported. Subgroup analyses examined the impact of baseline CIED status on outcomes. Results Among 1034 attempted procedures at 82 centers (mean [SD] age, 77.1 [10.6] years; 69.1% female; 73.2% NYHA functional class III/IV), a valve was successfully implanted in 1017 patients (98.4%). Mild or less TR was achieved in 98.4% of patients post procedure and in 97.7% at 30 days. At 30 days, all-cause mortality was 3.1%; stroke, 0.2%; bleeding, 7.9%; new CIED, 15.9% in CIED-naive patients; and heart failure hospitalization, 3.1%. There were significant improvements in NYHA functional class (class I/II, 82.7%; P < .001) and mean KCCQ-OS score (22.4 points; P < .001) from baseline to 30 days. There were no significant differences in 30-day mortality ( P = .47), heart failure hospitalization ( P > .99), and functional outcomes ( P = .55) when patients were stratified by baseline CIED status. Conclusions and Relevance Early US real-world experience with TTVR confirms safety and effectiveness in patients with severe TR. Thirty-day outcomes are consistent with the TRISCEND II pivotal trial, demonstrating acceptable safety, near-complete TR elimination, and significant health status improvements in an older, comorbid population. Rates of new CIED implantation and bleeding were lower than randomized clinical trial experience.
Recurrent Gastrointestinal Bleeding in Patients With Atrial Fibrillation Treated With Left Atrial Appendage Occlusion
Ramadan, Adham, Doma, Mohamed , Félix, Iuri Ferreira , Ahmed, Mahmoud Samy, Mahmoud, Ahmed K., Ismayl, Mahmoud, Karara, Yehia , Villablanca, Pedro A., Saw, J, DeSimone, Christopher V., Doma, Mohamed , Ferreira Felix, Iuri , Mahmoud, Ahmed K , DeSimone, Christopher V , Ramadan, Adham, Kamel, Ibrahim, Ismayl, Mahmoud , Villablanca, Pedro, Saw, Jacqueline , DeSimone, Christopher V. , Goldsweig, Andrew M.

Mayo Clinic

Pacing and Clinical Electrophysiology | February 21, 2026 | Volume: 49 | Issue: 7 | Pages: 898-910

10.1111/pace.70177 | PMID 41721735 Get It

ABSTRACT Background Concomitant atrial fibrillation (AF) and gastrointestinal (GI) bleeding present a clinical challenge due to recurrent bleeding risk associated with anticoagulation for AF‐associated stroke prevention. Left atrial appendage occlusion (LAAO) offers an alternative stroke prevention strategy, but its impact on recurrent GI bleeding remains unknown. Methods This retrospective, multicenter cohort study used the TriNetX database to identify adults with AF on oral anticoagulation and a history of GI bleeding. Patients were stratified by treatment with or without LAAO. 1:1 propensity score matching (PSM) was employed. The primary outcome was recurrent GI bleeding. Cox regression analysis was used to generate hazard ratios (HRs) with 95% confidence intervals (CIs). Odds ratios (ORs) were used to evaluate effect sizes between groups. Kaplan–Meier curves were used for time‐to‐event analyses. Results After PSM, 9259 patients were compared in each group. Odds of recurrent GI bleeding were consistently lower in patients undergoing LAAO than without LAAO across all follow‐up intervals: at 3 months (OR 0.84; 95% CI 0.78–0.91), 6 months, 1 year, 3 years, and 5 years (OR 0.87; 95% CI 0.82–0.92). Kaplan–Meier analysis demonstrated significantly lower risk of recurrent GI bleeding with LAAO (HR 0.80; 95% CI 0.76–0.84; p < 0.01). Conclusion In patients with AF and prior GI bleeding, LAAO was associated with a significantly lower risk of recurrent GI bleeding at short‐term and long‐term time intervals.
Sex-Based Differences in Outcomes With Percutaneous Transcatheter Repair of Mitral Regurgitation With the MitraClip System: Transcatheter Valve Therapy Registry From 2011 to 2017
Villablanca, Pedro , Vemulapalli, Sreekanth , Stebbins, Amanda , Dai, Dadi, So, Chak-Yu , Eng, Marvin H. , Wang, Dee Dee , Frisoli, Tiberio , Lee, James , Kang, Guson , Ibrahim, Homam , Staniloae, Cezar , Gaba, Prakriti , Lemor, Alejandro , Finn, Matthew , Leon, Martin B. , Villablanca, Pedro A , Lee, James C , Staniloae, Cezar , Lemor, Alejandro , Ramakrishna, Harish , Shah, Binita , Wang, Dee Dee , Szerlip, Molly , Williams, Mathew , O’Neill, William W. , Shah, Binita

Mayo Clinic

Circulation: Cardiovascular Interventions | November 16, 2021 | Volume: 14 | Issue: 11 | Pages: No page available

10.1161/circinterventions.120.009374 | PMID 34784236 Get It

Background: Women have a higher rate of adverse events after mitral valve surgery. We sought to evaluate whether outcomes after transcatheter edge-to-edge repair intervention by sex have similar trends to mitral valve surgery. Methods: The primary outcome was 1-year major adverse events defined as a composite of all-cause mortality, stroke, and any bleeding in the overall study cohort. Patients who underwent transcatheter edge-to-edge repair for mitral regurgitation with the MitraClip system in the Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy registry were evaluated. Linked administrative claims from the Centers for Medicare and Medicaid Services were used to evaluate 1-year clinical outcomes. Associations between sex and outcomes were evaluated using a multivariable logistic regression model for in-hospital outcomes and Cox model for 1-year outcomes. Results: From November 2013 to March 2017, 5295 patients, 47.6% (n=2523) of whom were female, underwent transcatheter edge-to-edge repair. Females were less likely to have >1 clip implanted ( P <0.001) and had a lower adjusted odds ratio of device success (adjusted odds ratio, 0.78 [95% CI, 0.67–0.90]), driven by lower odds of residual mitral gradient <5 mm Hg (adjusted odds ratio, 0.54 [CI, 0.46–0.63]) when compared with males. At 1-year follow-up, the primary outcome did not differ by sex. Female sex was associated with lower adjusted 1-year risk of all-cause mortality (adjusted hazard ratio, 0.80 [CI, 0.68–0.94]), but the adjusted 1-year risk of stroke and any bleeding did not differ by sex. Conclusions: No difference in composite outcome of all-cause mortality, stroke, and any bleeding was observed between females and males. Adjusted 1-year all-cause mortality was lower in females compared with males.
Short‐ and mid‐term outcomes in percutaneous mitral valve replacement using balloon expandable valves
Eng, Marvin H. , Kargoli, Faraj , Wang, Dee Dee , Frisoli, Tiberio , Villablanca, Pedro, Nemeh, Hassan, Guerrero, Mayra , O’Neill, Brian , Wyman, Janet , Guerrero, Mayra E , O'Neill, Brian P , Wang, Dee Dee , Lee, James C. , Villablanca, Pedro, Greenbaum, Adam B. , O’Neill, William W.

Mayo Clinic

Catheterization and Cardiovascular Interventions | June 9, 2021 | Volume: 98 | Issue: 6 | Pages: 1193-1203

10.1002/ccd.29783 | PMID 34106514 Get It

AbstractBackgroundDue to elevated surgical risk, transcatheter mitral valve replacement (TMVR) is used as an alternative for treating failed bioprosthetic valves, annuloplasty repairs and mitral annular calcification (MAC). We report the procedural and longitudinal outcomes for each subtype: Mitral valve‐in‐valve (MVIV), mitral valve‐in‐ring (MViR), and valve‐in‐MAC (ViMAC).MethodsConsecutive patients undergoing TMVR from October 2013 to December 2019 were assessed. Patients at high risk for left ventricular outflow tract obstruction had either alcohol septal ablation or intentional laceration of the anterior leaflet (LAMPOON).ResultsEight‐eight patients underwent TMVR; 38 MViV, 31 MViR, and 19 ViMAC procedures were performed. The median Society of Thoracic Surgery 30‐day predicted risk of mortality was 8.2% (IQR 5.2, 19.9) for all. Sapien 3 (78%) and transseptal access (98%) were utilized in most cases. All‐cause in‐hospital mortality, technical, and procedural success were 8%, 83%, and 66% respectively. Median follow up was 1.4 years (IQR 0.5–2.9 years) and overall survival was 40% at 4 years. Differential survival rates were observed with MViV doing the best, followed by MViR and ViMAC having a <20% survival at 4 years. After adjusting for co‐variates, MViV procedure was the strongest predictor of survival (HR 0.24 [95% CI 0.079–0.7]).ConclusionTMVR is performed in at high‐risk patients with attenuated long‐term survival. MViV has the best success and survival rate, but long‐term survival in MViR and ViMAC is guarded.
Racial, ethnic and socioeconomic disparities in patients undergoing left atrial appendage closure
Sparrow, Robbie , Sanjoy, Shubrandu , Choi, Yun‐Hee , Elgendy, Islam Y. , Jneid, Hani , Villablanca, Pedro , Holmes, David R. , Sposato, Luciano A. , Mamas, Mamas A. , Sparrow, Robert T. , Sposato, Luciano A , Mamas, Mamas , Bagur, Rodrigo , Elgendy, Islam Y , Sanjoy, Shubrandu S , Pershad, Ashish , Alraies, M Chadi , Bagur, Rodrigo

Mayo Clinic

Heart | April 1, 2021 | Volume: 107 | Issue: 24 | Pages: 1946-1955

10.1136/heartjnl-2020-318650 | PMID 33795381 Get It

Objective This manuscript aims to explore the impact of race/ethnicity and socioeconomic status on in-hospital complication rates after left atrial appendage closure (LAAC). Methods The US National Inpatient Sample was used to identify hospitalisations for LAAC between 1 October 2015 to 31 December 2018. These patients were stratified by race/ethnicity and quartiles of median neighbourhood income. The primary outcome was the occurrence of in-hospital major adverse events, defined as a composite of postprocedural bleeding, cardiac and vascular complications, acute kidney injury and ischaemic stroke. Results Of 6478 unweighted hospitalisations for LAAC, 58% were male and patients of black, Hispanic and ‘other’ race/ethnicity each comprised approximately 5% of the cohort. Adjusted by the older Americans population, the estimated number of LAAC procedures was 69.2/100 000 for white individuals, as compared with 29.5/100 000 for blacks, 47.2/100 000 for Hispanics and 40.7/100 000 for individuals of ‘other’ race/ethnicity. Black patients were ~5 years younger but had a higher comorbidity burden. The primary outcome occurred in 5% of patients and differed significantly between racial/ethnic groups (p<0.001) but not across neighbourhood income quartiles (p=0.88). After multilevel modelling, the overall rate of in-hospital major adverse events was higher in black patients as compared with whites (OR: 1.60, 95% CI 1.22 to 2.10, p<0.001); however, the incidence of acute kidney injury was higher in Hispanics (OR: 2.19, 95% CI 1.52 to 3.17, p<0.001). No significant differences were found in adjusted overall in-hospital complication rates between income quartiles. Conclusion In this study assessing racial/ethnic disparities in patients undergoing LAAC, minorities are under-represented, specifically patients of black race/ethnicity. Compared with whites, black patients had higher comorbidity burden and higher rates of in-hospital complications. Lower socioeconomic status was not associated with complication rates.
Transcatheter Mitral Valve Replacement After Surgical Repair or Replacement
Simonato, Matheus , Ribeiro, Henrique Barbosa , Webb, John G. , Backer, Ole De , Villablanca, Pedro, Rihal, Charanjit S. , Eleid, Mackram F. , Kempfert, Jörg , Unbehaun, Axel , Erlebach, Magdalena , Casselman, Filip , Saia, Francesco , Ubben, Timm , Meincke, Felix , Napodano, Massimo, Codner, Pablo , Schöfer, Joachim, Pelletier, Marc , Cheung, Anson , Shuvy, Mony , Palma, José Honório , Duncan, Alison , Sinning, Jan-Malte, Arbel, Yaron , Weger, Arend de , Eltchaninoff, Hélène, Hemery, Thibault, Tchétché, Didier , Dumonteil, Nicolas, Rodés‐Cabau, Josep , Kim, Won-Keun, Spargias, Konstantinos, Kourkoveli, Panagiota, Ben‐Yehuda, Ori , Barbanti, Marco , Fiorina, Claudia , Thukkani, Arun K., Jones, Noah, Presbitero, Patrizia , Petronio, Anna Sonia , Champagnac, Didier , Rudolph, Tanja K. , Iadanza, Alessandro , Nombela‐Franco, Luis , Bonaros, Nikolaos , Kass, Malek , Amabile, Nicolas , Messina, Antonio , Andreas, Martin , Welsh, Robert C. , Schoels, Wolfgang , Hellig, Farrel, Windecker, Stephan , Stortecky, Stefan , Maisano, Francesco , Stone, Gregg W. , Dvir, Danny , Rihal, Charanjit, Eleid, Mackram, Nombela-Franco, Luis , Windecker, Stephan , Maisano, Francesco , De Backer, Ole , Whisenant, Brian K. , Kornowski, Ran , Guerrero, Mayra , Wijeysundera, Harindra C. , Søndergaard, Lars , Rihal, Charanjit S. , Adam, Matti , Montorfano, Matteo , Ancona, Marco , Gaia, Diego Felipe , Hildick-Smith, David , Veulemans, Verena , Sinning, Jan‐Malte, Testa, Luca , Landes, Uri , Kim, Won-Keun, Teles, Rui Campante , Mackensen, G. Burkhard , Allali, Abdelhakim , Bleiziffer, Sabine , Salizzoni, Stefano , Agrifoglio, Marco , Bruschi, Giuseppe , Chhatriwalla, Adnan K , Hirji, Sameer

Mayo Clinic

Circulation | September 25, 2020 | Volume: 143 | Issue: 2 | Pages: 104-116

10.1161/circulationaha.120.049088 | PMID 32975133 Get It

Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. Results: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76–996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510–1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR ( P <0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients ( P =0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P <0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P =0.02). The rates of Mitral Valve Academic Research Consortium–defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P =0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74–12.56; P =0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88–21.53; P <0.001) were both independently associated with repeat mitral valve replacement. Conclusions: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.
Complete percutaneous apical access and closure: Short and intermediate term outcomes
Eng, Marvin H. , Kherallah, Riyad , Guerrero, Mayra , Frisoli, Tiberio , Villablanca, Pedro , Wang, Dee Dee , Wyman, Janet , Wang, Dee Dee , Guerrero, Mayra E , Greenbaum, Adam B. , Lee, James , O’Neill, William W.

Mayo Clinic

Catheterization and Cardiovascular Interventions | January 20, 2020 | Volume: 96 | Issue: 2 | Pages: 481-487

10.1002/ccd.28731 | PMID 31957915 Get It

AbstractObjectivesTo examine the safety of utilizing transapical access during structural interventions.BackgroundComplex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access.MethodsRetrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths.ResultsA total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol‐based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50–652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205–628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices.ConclusionsTransapical access and closure with nitinol‐based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high‐risk patients.
Association of peripheral artery disease with in‐hospital outcomes after endovascular transcatheter aortic valve replacement
Mohananey, Divyanshu , Villablanca, Pedro , Ando, Tomo , Wang, Dee Dee , Wiley, José , Eng, Marvin H. , Shah, Binita , Saucedo, Jorge , Bhatt, Deepak L. , Ando, Tomo , Wang, Dee Dee , Eng, Marvin , Ramakrishna, Harish , Bhatt, Deepak L , Shah, Binita , Gupta, Tanush , Ranka, Sagar , Bhatia, Nirmanmoh , Adegbala, Oluwole Muyiwa , Kalra, Ankur , O’Neill, William W.

Mayo Clinic

Catheterization and Cardiovascular Interventions | April 26, 2019 | Volume: 94 | Issue: 2 | Pages: 249-255

10.1002/ccd.28310 | PMID 31025488 Get It

AbstractObjectivesThe aim of this study was to determine the prevalence of peripheral artery disease (PAD) and its association with in‐hospital outcomes after endovascular transcatheter aortic valve replacement (EV‐TAVR).BackgroundTAVR is an established treatment for patients at prohibitive, high, or intermediate surgical risk. PAD is a significant comorbidity in the determination of surgical risk. However, data on association of PAD with outcomes after EV‐TAVR are limited.MethodsPatients in the National Inpatient Sample who underwent EV‐TAVR between January 1, 2012 and September 30, 2015 were evaluated. The primary outcome was in‐hospital mortality.ResultsA total of 51,685 patients underwent EV‐TAVR during the study period. Of these, 12,740 (24.6%) had a coexisting diagnosis of PAD. The adjusted odds for in‐hospital mortality [OR 1.08 (95% CI 0.83–1.41)], permanent pacemaker implantation [OR 0.98 (0.85–1.14)], conversion to open aortic valve replacement [OR 1.05 (0.49–2.26)], or acute myocardial infarction [OR 1.31(0.99–1.71)] were not different in patients with versus without PAD. However, patients with PAD had greater adjusted odds of vascular complications [OR 1.80 (1.50–2.16)], major bleeding [OR 1.20 (1.09–1.34)], acute kidney injury (AKI) [OR 1.19 (1.05–1.36)], cardiac complications [aOR 1.21 (1.01–1.44)], and stroke [OR 1.39(1.10–1.75)] compared with patients without PAD. Length of stay (LOS) was significantly longer for patients with PAD [7.23 (0.14) days vs. 7.11 (0.1) days, p < 0.001].ConclusionOf patients undergoing EV‐TAVR, ~25% have coexisting PAD. PAD was not associated with increased risk of in‐hospital mortality but was associated with higher risk of vascular complications, major bleeding, AKI, stroke, cardiac complications, and longer LOS.
Bivalirudin versus heparin in patients undergoing percutaneous peripheral interventions: A systematic review and meta-analysis
Olmedo, Wilman, Villablanca, Pedro , Sanina, Cristina , Weinreich, Michael , Brevik, Jeannine, Avendaño, Ricardo , Bravo, Claudio , Babaev, Anvar, Attubato, Michael , Hernandez-Suarez, DF, Cox‐Alomar, Pedro, Pyo, Robert, Krishnan, Prakash , Wiley, José , Villablanca, Pedro A , Avendano, Ricardo , Ramakrishna, Harish , Hernandez-Suarez, D F , Walker, Jonathan R. , Romero, Jorge E.

Mayo Clinic

Vascular | December 1, 2018 | Volume: 27 | Issue: 1 | Pages: 78-89

10.1177/1708538118807522 | PMID 30501582 Get It

Background Bivalirudin may be an effective alternative anticoagulant to heparin for use in percutaneous peripheral interventions. We aimed to compare the safety and efficacy of bivalirudin versus heparin as the procedural anticoagulant agent in patients undergoing percutaneous peripheral intervention. Methods For this meta-analysis and systematic review, we conducted a search in PubMed, Medline, Embase, and Cochrane for all the clinical studies in which bivalirudin was compared to heparin as the procedural anticoagulant in percutaneous peripheral interventions. Outcomes studied included all-cause mortality, all-bleeding, major and minor bleeding, and access site complications. Results Eleven studies were included in the analysis, totaling 20,137 patients. There was a significant difference favoring bivalirudin over heparin for all-cause mortality (risk ratio 0.58, 95% CI 0.39–0.87), all-bleeding (risk ratio 0.62, 95% CI 0.50–0.78), major bleeding (risk ratio 0.61, 95% CI 0.39–0.96), minor bleeding (risk ratio 0.66, 95% CI 0.47–0.92), and access site complications (risk ratio 0.66, 95% CI 0.51–0.84). There was no significant difference in peri-procedural need for blood transfusions (risk ratio 0.79, 95% CI 0.57–1.08), myocardial infarction (risk ratio 0.87, 95% CI 0.59–1.28), stroke (risk ratio 0.77, 95% CI 0.59–1.01), intracranial bleeding (risk ratio 0.77, 95% CI 0.29–2.02), or amputations (OR 0.75, 95% CI 0.53–1.05). Conclusion Our meta-analysis suggests that bivalirudin use for percutaneous peripheral interventions is associated with lower all-cause mortality, bleeding, and access site complications as compared to heparin. Further large randomized trials are needed to confirm the current results.
Comparison of local versus general anesthesia in patients undergoing transcatheter aortic valve replacement: An updated meta‐analysis
Villablanca, Pedro , Mohananey, Divyanshu , Villablanca, Pedro A , Ramakrishna, Harish

Mayo Clinic

Catheterization and Cardiovascular Interventions | April 16, 2018 | Volume: 92 | Issue: 5 | Pages: 1018-1019

10.1002/ccd.27639 | PMID 29659154 Get It