The Heart Center, Rigshospitalet, Copenhagen, Denmark.
Citations 4
Standardized endpoint definitions for trials of transcatheter left atrial appendage closure: a consensus from the Left Atrial Appendage Academic Research Consortium
European Heart Journal | July 9, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available
Abstract Since its introduction in 2002, left atrial appendage closure (LAAC) has rapidly expanded as an alternative to anticoagulation in patients with atrial fibrillation at high risk of stroke. Harmonized processes for data collection, analysis, and reporting in LAAC trials are essential to enhance research quality and improve clinical practice. The Left Atrial Appendage Academic Research Consortium (LAARC) initiative is an independent collaboration of academic research organizations, cardiology and neurology experts, clinical trialists, and regulatory authorities from the USA, Europe, and Asia. The consortium engaged clinical experts, regulators—including the US Food and Drug Administration (FDA), European Notified Bodies, and Japan’s Pharmaceuticals and Medical Devices Agency (PMDA)—and industry leaders to define standardized study elements and endpoints for LAAC trials. Key considerations included alignment with prior Academic Research Consortium initiatives, procedural and mechanistic insights, and clinical relevance. Consensus definitions were proposed for mortality, stroke, bleeding, and device performance, along with composite endpoints for safety and effectiveness. The proposed LAARC consensus definitions aim to standardize endpoint reporting, improve comparability across studies, and support regulatory and clinical trial applications for this evolving therapy through broad dissemination in the peer-reviewed literature.
Comparison of Flow Dynamics After Left Atrial Appendage Occlusion With the Watchman FLX Versus Amulet Devices: Implications for Device‐Related Thrombosis
Catheterization and Cardiovascular Interventions | June 25, 2025 | Volume: 106 | Issue: 4 | Pages: 2084-2092
ABSTRACT Background This study aims to assess how Watchman FLX (Boston Scientific) and Amplatzer Amulet (Abbott) devices for left atrial appendage occlusion (LAAO) impact the flow dynamics in the LA and the risk of device‐related thrombosis (DRT). Methods Flow simulations were carried out for 12 AF patients before and after undergoing LAAO. Six patients had Watchman FLX while the other six had Amulet devices, of which three in each group had DRT. The flow parameters investigated included the LA velocities, pressure, time averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT). Low TAWSS and high OSI and RRT are generally associated with flow stasis and thrombosis. Results LA flow dynamics differed significantly between the two groups. On average, after LAAO, the Amulet patients exhibited a 25% increase in TAWSS and 24% decrease in RRT while the Watchman FLX patients exhibited, on average, a 24% decrease in TAWSS and a 23% increase in RRT. Both populations experienced an increase in LA pressure (~10% for Amulet patients and 16% for Watchman FLX patients). Increased DRT volume seems to be correlated with low TAWSS and elevated RRT. Conclusion This preliminary study suggests that the Amulet device might be associated with improved LA flow dynamics and a potentially lower incidence of DRT compared with the Watchman. However, a larger clinical study is needed to confirm these findings.
Understanding the role of the left atrial appendage on the flow in the atrium
Catheterization and Cardiovascular Interventions | July 21, 2024 | Volume: 104 | Issue: 6 | Pages: 1290-1298
Abstract Background The exclusion/occlusion of the left atrial appendage (LAA) is a treatment option for atrial fibrillation (AF) patients who are at high risk of stroke and high risk of bleeding. As the role of the LAA is not well understood or explored, this study aims to assess its role on flow dynamics in the left atrium. Methods Computational fluid dynamics (CFD) simulations were carried out for nine AF patients before and after LAA exclusion. The flow parameters investigated included the LA velocities, Time Averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI), Relative Residence Time (RRT), and Pressure in the LA. Results This study shows that, on average, a decrease in TAWSS (1.82 ± 1.85 Pa to 1.27 ± 0.96 Pa, p < 0.05) and a slight increase in OSI (0.16 ± 0.10 to 0.17 ± 0.10, p < 0.05), RRT (1.87 ± 1.84 Pa −1 to 2.11 ± 1.78 Pa −1 , p < 0.05), and pressure (−19.2 ± 6.8 mmHg to −15.3 ± 8.3 mmHg, p < 0.05) were observed in the LA after the exclusion of the LAA, with a decrease in low‐magnitude velocities. Conclusion The exclusion of the LAA seems to be associated with changes in LA flow dynamics. Further studies are needed to elucidate the clinical implications of these changes.
Transcatheter Mitral Valve Replacement After Surgical Repair or Replacement
Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. Results: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76–996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510–1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR ( P <0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients ( P =0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P <0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P =0.02). The rates of Mitral Valve Academic Research Consortium–defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P =0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74–12.56; P =0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88–21.53; P <0.001) were both independently associated with repeat mitral valve replacement. Conclusions: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.