Citations

Clear

10 citation(s) found for "Verma, Atul".

Effectiveness and Safety of Intramyocardial Needle Ablation for Refractory Ventricular Tachycardia and Premature Ventricular Complexes: A Systematic Review and Meta‐Analysis
Qureshi, Muhammad Ahmad , Rawlley, Bharat , Jain, Vardhmaan, Verma, Atul, Siontis, Konstantinos C. , Deshmukh, Abhishek , Khan, Arfaat , Gupta, Kartik , Rawlley, Bharat , Siontis, Konstantinos C , Deshmukh, Abhishek J , Jain, Vardhmaan, Verma, Atul, Raad, Mohamad

Mayo Clinic

Journal of Cardiovascular Electrophysiology | July 14, 2025 | Volume: 36 | Issue: 9 | Pages: 2279-2286

10.1111/jce.70000 | PMID 40654169 Get It

ABSTRACTIntroductionIntramyocardial needle ablation is a novel technique for treating refractory ventricular tachycardia (VT) and premature ventricular complexes (PVC). However, studies defining the effectiveness and safety of this procedure are limited. This meta‐analysis aims to evaluate the safety and effectiveness of needle ablation for VT and PVC refractory to standard ablation.MethodsEmbase, Ovid (includes Medline), and ClinicalTrials.gov were searched from inception to December 31, 2024. Human studies on needle ablation for recurrent VT and PVC were included. Primary outcome was immediate effectiveness (no immediate post‐procedural inducible VT or PVC). Secondary outcomes were long‐term effectiveness (no clinical VT or PVC at 6 months) and safety (composite measure of peri‐ and post‐procedural complications).ResultsA total of five studies including 180 patients (140 VT; 40 PVC) were analyzed. Mean ages ranged from 54 to 66 years. Among 129 patients with VT, immediate effectiveness was 75% (95% CI, 54–92; I2 80%), and cumulative freedom from clinical VT dropped to 43% at 6 months (95% CI, 35–52; I2 0%). Among 40 patients with PVC, immediate effectiveness was 82% (95% CI, 67–94; I2 0%), and long‐term effectiveness was 76% (95% CI, 61–90; I2 0%). Safety outcomes were reported in 19% of patients (95% CI, 13–27; I2 0%) and 10% of patients (95% CI 1, 23; I2 0%) in the VT and PVC arm, respectively. Death related to ablation was report in 7 patients (5.0%) only in the VT studies.ConclusionIntramyocardial needle ablation is an emerging alternative approach for refractory VT and PVC ablation, showing cautious but promising results and safety profiles. Prospective studies and an international registry could provide valuable insights needed for optimal patient selection and protocol refinement.
Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
Haines, David E. , Boersma, Lucas V.A. , Sood, Nitesh , Natale, Andrea , Marchlinski, Francis E. , Calkins, Hugh , Sanders, Prashanthan , Packer, Douglas L. , Kuck, Karl-Heinz , Hindricks, Gerhard , Önal, Birce , Cerkvenik, Jeffrey , Tada, Hiroshi , Investigators, on behalf of the PULSED AF, Verma, Atul , Boersma, Lucas , Natale, Andrea , Marchlinski, Francis E , Calkins, Hugh , Sanders, Prashanthan , Packer, Douglas L , Kuck, Karl-Heinz , Onal, Birce , Verma, Atul , DeLurgio, David B. , Investigators, on behalf of the PULSED AF

Mayo Clinic

Circulation | March 6, 2023 | Volume: 147 | Issue: 19 | Pages: 1422-1432

10.1161/circulationaha.123.063988 | PMID 36877118 Get It

Background: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. Methods: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. Results: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. Conclusions: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04198701.
Ablation of Refractory Ventricular Tachycardia Using Intramyocardial Needle Delivered Heated Saline-Enhanced Radiofrequency Energy: A First-in-Man Feasibility Trial
Packer, Douglas L. , Wilber, David J. , Dyrda, Katia , Nault, Isabelle , Killu, Ammar M. , Kanagasundram, Arvindh N. , Richardson, Travis D. , Stevenson, William G. , Curley, Michael , Investigators, for the SERF, Kapa, Suraj , Dyrda, Katia , Nault, Isabelle , Killu, Ammar M , Kanagasundram, Arvindh , Richardson, Travis , Stevenson, William , Verma, Atul , Curley, Michael , Kapa, Suraj , Verma, Atul , Investigators, for the SERF

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | July 1, 2022 | Volume: 15 | Issue: 8 | Pages: No page available

10.1161/circep.121.010347 | PMID 35776711 Get It

Background: Ablation of ventricular tachycardia (VT) is limited by the inability to create penetrating lesions to reach intramyocardial origins. Intramural needle ablation using in-catheter, heated saline-enhanced radio frequency (SERF) energy uses convective heating to increase heat transfer and produce deeper, controllable lesions at intramural targets. This first-in-human trial was designed to evaluate the safety and efficacy of SERF needle ablation in patients with refractory VT. Methods: Thirty-two subjects from 6 centers underwent needle electrode ablation. Each had recurrent drug-refractory monomorphic VT after implantable cardioverter defibrillator implantation and prior standard ablation. During the SERF study procedure, one or more VTs were induced and mapped. The SERF needle catheter was used to create intramural lesions at targeted VT site(s). Acute procedural success was defined as noninducibility of the clinical VT after the procedure. Patients underwent follow-up at 30 days, and 3 and 6 months, with implantable cardioverter defibrillator interrogation at follow-up to determine VT recurrence. Results: These refractory VT patients (91% male, 66±10 years, ejection fraction 35±11%; 56% ischemic, and 44% nonischemic) had a median of 45 device therapies (shock/antitachycardia pacing) for VT in the 3 to 6 months pre-SERF ablation. The study catheter was used to deliver an average of 10±5 lesions per case, with an average of 430±295 seconds of radiofrequency time, 122±65 minute of catheter use time, and a procedural duration of 4.3±1.3 hours. Acute procedural success was 97% for eliminating the clinical VT. At average follow-up of 5 months (n=32), device therapies were reduced by 89%. Complications included 2 periprocedural deaths: an embolic mesenteric infarct and cardiogenic shock, 2 mild strokes, and a pericardial effusion treated with pericardiocentesis (n=1). Conclusions: Intramural heated saline needle ablation showed complete acute and satisfactory mid-term control of difficult VTs failing 1 to 5 prior ablations and drug therapy. Further study is warranted to define safety and longer-term efficacy. Registration: URL: https://www.clinicaltrials.gov ; Unique Identifier: NCT03628534 and NCT02994446.
First-in-Human Experience and Acute Procedural Outcomes Using a Novel Pulsed Field Ablation System: The PULSED AF Pilot Trial
Boersma, Lucas V.A. , Haines, David E., Natale, Andrea , Marchlinski, Francis E. , Sanders, Prashanthan , Calkins, Hugh , Packer, Douglas L. , Hummel, John D. , Önal, Birce , Rosen, Sofi, Kuck, Karl-Heinz , Hindricks, Gerhard, Wilsmore, Bradley , Verma, Atul , Boersma, Lucas , Natale, Andrea , Marchlinski, Francis E , Sanders, Prashanthan , Calkins, Hugh , Packer, Douglas L , Hummel, John , Onal, Birce , Kuck, Karl-Heinz , Wilsmore, Bradley , Haines, David E., Rosen, Sofi, Hindricks, Gerhard

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | December 29, 2021 | Volume: 15 | Issue: 1 | Pages: No page available

10.1161/circep.121.010168 | PMID 34964367 Get It

Background: Pulsed field ablation (PFA) is a novel form of ablation using electrical fields to ablate cardiac tissue. There are only limited data assessing the feasibility and safety of this type of ablation in humans. Methods: PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; https://www.clinicaltrials.gov ; unique identifier: NCT04198701) is a nonrandomized, prospective, multicenter, global, premarket clinical study. The first-in-human pilot phase evaluated the feasibility and efficacy of pulmonary vein isolation using a novel PFA system delivering bipolar, biphasic electrical fields through a circular multielectrode array catheter (PulseSelect; Medtronic, Inc). Thirty-eight patients with paroxysmal or persistent atrial fibrillation were treated in 6 centers in Australia, Canada, the United States, and the Netherlands. The primary outcomes were ability to achieve acute pulmonary vein isolation intraprocedurally and safety at 30 days. Results: Acute electrical isolation was achieved in 100% of pulmonary veins (n=152) in the 38 patients. Skin-to-skin procedure time was 160±91 minutes, left atrial dwell time was 82±35 minutes, and fluoroscopy time was 28±9 minutes. No serious adverse events related to the PFA system occurred in the 30-day follow-up including phrenic nerve injury, esophageal injury, stroke, or death. Conclusions: In this first-in-human clinical study, 100% pulmonary vein isolation was achieved using only PFA with no PFA system–related serious adverse events. Graphic Abstract: A graphic abstract is available for this article.
Primer on Pulsed Electrical Field Ablation
Asivatham, Samuel J., Castellví, Quim , Neal, Robert E. , Asirvatham, Samuel J. , Verma, Atul , Asirvatham, Samuel J , Neal, Robert E , Verma, Atul , Deneke, Thomas

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | September 20, 2021 | Volume: 14 | Issue: 9 | Pages: No page available

10.1161/circep.121.010086 | PMID 34538095 Get It

Pulsed electrical field (PEF) energy is a promising technique for catheter ablation of cardiac arrhythmias. In this article, the key aspects that need to be considered for safe and effective PEF delivery are reviewed, and their impact on clinical feasibility is discussed. The most important benefit of PEF appears to be the ability to kill cells through mechanisms that do not alter stromal proteins, sparing sensitive structures to improve safety, without sacrificing cardiomyocyte ablation efficacy. Many parameters affect PEF treatment outcomes, including pulse intensity, waveform shape, and number of pulses, as well as electrode configuration and geometry. These physical and electrical characteristics must be titrated carefully to balance target tissue effects with collateral implications (muscle contraction, temperature rise, risk of electrical arcing events). It is important to note that any combination of parameters affecting PEF needs to be tested for clinical efficacy and safety. Applying PEF clinically requires knowledge of the fundamentals of this technology to exploit its opportunities and generate viable, durable health improvements for patients.
Reduction in Pulmonary Vein Stenosis and Collateral Damage With Pulsed Field Ablation Compared With Radiofrequency Ablation in a Canine Model
Howard, Brian, Haines, David E. , Packer, Douglas L. , Kirchhof, Nicole , Barka, Noah , Önal, Birce , Fraasch, Steve, Miklavčič, Damijan , Stewart, Mark T. , Packer, Douglas, Onal, Birce , Verma, Atul

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | July 27, 2020 | Volume: 13 | Issue: 9 | Pages: No page available

10.1161/circep.120.008337 | PMID 32877256 Get It

Background: Pulmonary vein (PV) stenosis is a highly morbid condition that can result after catheter ablation for PV isolation. We hypothesized that pulsed field ablation (PFA) would reduce PV stenosis risk and collateral injury compared with irrigated radiofrequency ablation (IRF). Methods: IRF and PFA deliveries were randomized in 8 dogs with 2 superior PVs ablated using one technology and 2 inferior PVs ablated using the other technology. IRF energy (25–30 W) or PFA was delivered (16 pulse trains) at each PV in a proximal and in a distal site. Contrast computed tomography scans were collected at 0, 2, 4, 8, and 12-week (termination) time points to monitor PV cross-sectional area at each PV ablation site. Results: Maximum average change in normalized cross-sectional area at 4-weeks was −46.1±45.1% post-IRF compared with −5.5±20.5% for PFA ( P ≤0.001). PFA-treated targets showed significantly fewer vessel restrictions compared with IRF ( P ≤0.023). Necropsy showed expansive PFA lesions without stenosis in the proximal PV sites, compared with more confined and often incomplete lesions after IRF. At the distal PV sites, only IRF ablations were grossly identified based on focal fibrosis. Mild chronic parenchymal hemorrhage was noted in 3 left superior PV lobes after IRF. Damage to vagus nerves as well as evidence of esophagus dilation occurred at sites associated with IRF. In contrast, no lung, vagal nerve, or esophageal injury was observed at PFA sites. Conclusions: PFA significantly reduced risk of PV stenosis compared with IRF postprocedure in a canine model. IRF also caused vagus nerve, esophageal, and lung injury while PFA did not.
Abstract 189: Identifying Patients at Highest Risk of Developing Atrial Fibrillation and the Role of Remote Prior Stroke: Insights From the REVEAL AF Study
Elkind, Mitchell S, Kowey, Peter R. , Halperin, Jonathan L. , Ziegler, Paul , Pouliot, Erika , Reiffel, James A. , Wachter, Rolf , Verma, Atul , Gersh, Bernard J.

Mayo Clinic

Stroke | October 8, 2018 | Volume: 49 | Issue: Suppl_1 | Pages: No page available

10.1161/str.49.suppl_1.189 Get It

Introduction: Recent trials using insertable cardiac monitors (ICMs) show high rates of atrial fibrillation (AF) in those at risk of developing AF based on demographics. Further identifying subsets who could benefit most from ICMs is desirable. We evaluated if the recently-developed HAVOC risk score which has predicted AF in cryptogenic stroke patients also predicts AF detection by ICMs in those without a recent stroke. Methods: Participants from the prospective REVEAL AF study, which reported frequent clinically unrecognized AF in patients at risk for AF (CHADS 2 scores ≥3 or =2 with ≥1 additional risk factor), with ICM data and not on anti-arrhythmic drugs were included. Ischemic stroke <1 year ago excluded participation. HAVOC scores were calculated using points for hypertension (2), age ≥75 (2), valvular disease (2), vascular disease (1), obesity (1), congestive heart failure (4), and coronary artery disease (2). Prior stroke, an AF outcome, generally not a cause, is not included. Score classification is: low (0-4), intermediate (5-9), or high (10-14). Corresponding AF detection rates were compared via the log-rank test. Results: Among 391 participants, 95 (24%), 241 (62%), and 55 (14%) had low, intermediate, and high HAVOC scores, respectively. At 18 months, AF incidence was significantly less for those with low (19.5%) vs intermediate (32.1%) or high (34.2%) scores (p=0.045, Figure). At 18 months, AF incidence was similar among those with (n=79) vs. without (n=312) a history of remote stroke (27.1% vs. 29.9%; p>0.05, median time from stroke to ICM insertion=4 years). Conclusions: The HAVOC risk score identified a subset of high risk individuals at greatest risk of developing AF. AF incidence rates were similar among those with and without prior remote stroke. Remote strokes may not be a strong predictor of AF in this population. HAVOC scores could be a useful approach to identify those at high likelihood of manifesting AF, as best documented by long-term monitoring.
2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation
Calkins, Hugh , Hindricks, Gerhard , Cappato, Riccardo , Kim, Young‐Hoon , Aguinaga, Luis, Akar, Joseph G. , Badhwar, Vinay , Camm, A. John , Chen, Peng‐Sheng , Chen, Shih‐Ann , Chung, Mina K. , Nielsen, Jens Cosedis , Curtis, Anne B. , Davies, D. Wyn, Groot, Natasja M.S. de , Duytschaever, Mattias , Edgerton, James R. , Ellenbogen, Kenneth A. , Ernst, Sabine , Fenelon, Guilherme , Gerstenfeld, Edward P. , Haines, David E. , Haïssaguerre, Michel , Jackman, Warren M. , Jalife, José , Kalman, Jonathan M. , Kautzner, Josef , Kottkamp, Hans , Kuck, Karl Heinz, Kumagai, Koichiro , Lee, Richard, Lewalter, Thorsten , Lindsay, Bruce D., Mansour, Moussa , Michaud, Gregory F., Nakagawa, Hiroshi , Natale, Andrea , Okumura, Ken , Packer, Douglas L. , Reynolds, Matthew R. , Sanders, Prashanthan , Scanavacca, Maurício , Schilling, Richard J. , Tondo, Claudio , Tsao, Hsuan-Ming, Verma, Atul , Wilber, David J. , Reviewers:, Document, Paola, Ângelo Amato Vincenzo de , Kistler, Peter M. , Pisani, Cristiano , Raviele, Antonio , Satomi, Kazuhiro , Stiles, Martin K. , Willems, Stephan , Haı̈ssaguerre, Michel , Packer, Douglas, Verma, Atul , Natale, Andrea , Sanders, Prashanthan , Nielsen, Jens C , de Groot, Natasja M S , Saad, Eduardo , Brugada, Josép , Day, John , d'Avila, Andre , Biase, Luigi Di , Ellinor, Patrick T. , Haissaguerre, Michel , Helm, Robert H. , Hylek, Elaine M. , Macle, Laurent , Marchlinski, Francis E. , Michaud, Gregory F. , Nattel, Stanley , Pokushalov, Evgeny A. , Tsao, Hsuan-Ming, Yamane, Teiichi , Reviewers:, Document, Blomström‐Lundqvist, Carina , Lip, Gregory Y H , Peters, Nicholas Simon , Scanavacca, Maurício , Tondo, Claudio , Ernst, Sabine , Ellenbogen, Kenneth A

Mayo Clinic

EP Europace | January 17, 2018 | Volume: 20 | Issue: 1 | Pages: e1-e160

10.1093/europace/eux274 | PMID 29016840 Get It

2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summary
Calkins, Hugh , Hindricks, Gerhard , Cappato, Riccardo , Kim, Young‐Hoon , Aguinaga, Luis, Akar, Joseph G. , Badhwar, Vinay , Camm, A. John , Chen, Peng‐Sheng , Chen, Shih‐Ann , Chung, Mina K. , Nielsen, Jens Cosedis , Curtis, Anne B. , Davies, D. Wyn, Groot, Natasja M.S. de , Duytschaever, Mattias , Edgerton, James R. , Ellenbogen, Kenneth A. , Ernst, Sabine , Fenelon, Guilherme , Gerstenfeld, Edward P. , Haines, David E. , Haïssaguerre, Michel , Jackman, Warren M. , Jalife, José , Kalman, Jonathan M. , Kautzner, Josef , Kottkamp, Hans , Kuck, Karl Heinz, Kumagai, Koichiro , Lee, Richard, Lewalter, Thorsten , Lindsay, Bruce D., Mansour, Moussa , Michaud, Gregory F., Nakagawa, Hiroshi , Natale, Andrea , Okumura, Ken , Packer, Douglas L. , Reynolds, Matthew R. , Sanders, Prashanthan , Scanavacca, Maurício , Schilling, Richard J. , Tondo, Claudio , Tsao, Hsuan-Ming, Verma, Atul , Wilber, David J. , Haı̈ssaguerre, Michel , Packer, Douglas, Verma, Atul , Natale, Andrea , Sanders, Prashanthan , Nielsen, Jens C , de Groot, Natasja M S , Saad, Eduardo , Brugada, Josép , Day, John , d'Avila, Andre , Biase, Luigi Di , Ellinor, Patrick T. , Haissaguerre, Michel , Helm, Robert H. , Hylek, Elaine M. , Macle, Laurent , Marchlinski, Francis E. , Michaud, Gregory F. , Nattel, Stanley , Pokushalov, Evgeny A. , Tsao, Hsuan-Ming, Yamane, Teiichi , Scanavacca, Maurício , Tondo, Claudio , Ernst, Sabine , Ellenbogen, Kenneth A

Mayo Clinic

EP Europace | January 5, 2018 | Volume: 20 | Issue: 1 | Pages: 157-208

10.1093/europace/eux275 | PMID 29016841 Get It

Incidence of Previously Undiagnosed Atrial Fibrillation Using Insertable Cardiac Monitors in a High-Risk Population
Reiffel, James A. , Kowey, Peter R. , Halperin, Jonathan L. , Wachter, Rolf , Pouliot, Erika , Ziegler, Paul , Investigators, for the REVEAL AF, Verma, Atul , Gersh, Bernard J. , Investigators, for the REVEAL AF

Mayo Clinic

JAMA Cardiology | August 26, 2017 | Volume: 2 | Issue: 10 | Pages: 1120

10.1001/jamacardio.2017.3180 | PMID 28842973 Get It