Abstract Purpose Failed stapes surgery presents a diagnostic challenge requiring high-resolution imaging to guide revision. Energy-integrating detector CT (EID-CT) is widely used but limited by spatial resolution and metal artifact. Photon-counting CT (PCCT) offers improved spatial resolution and reduced noise, with potential advantages in temporal bone imaging. The purpose of this study was to compare PCCT and EID-CT in identifying etiologies of failed primary stapes surgery, with emphasis on diagnostic accuracy, interobserver agreement, and interpreter confidence Methods In this retrospective study, 38 patients with failed primary stapes surgery who underwent successful revision surgery and pre-revision CT were included; 18 underwent PCCT and 20 underwent EID-CT. Three expert reviewers independently determined the cause of surgical failure, compared against the reference standard of intraoperative findings at revision. Diagnostic accuracy, interobserver agreement (Fleiss kappa), and reader confidence were compared between modalities. Results Overall interobserver agreement was substantially higher with PCCT (κ = 0.75; 95% CI, 0.60–0.90) than EID-CT (κ = 0.44; 95% CI, 0.30–0.59), with improved agreement observed across etiologies of failure; confidence intervals were non-overlapping for overall agreement and ossicular discontinuity. Consensus diagnostic accuracy was comparable between modalities (88.9% PCCT vs 85% EID-CT; p = 1.00), as was interpreter confidence (4.33 PCCT vs 4.17 EID-CT; p = 0.29). Conclusion In this small cohort, PCCT and EID-CT demonstrated similar diagnostic accuracy and reader confidence, whereas PCCT demonstrated significantly higher interobserver agreement, suggesting more reproducible assessment of failed stapes surgery and a potential role in supporting revision surgical planning.
Coupling of Low Frequency Hemodynamic Oscillations Between the Brain and Spinal Cord
ABSTRACTIn Functional Magnetic Resonance Imaging (fMRI), the primary contrast is Blood Oxygen Level Dependent (BOLD) signal. Systemic Low Frequency Oscillations (sLFO) are BOLD signals between 0.01 and 0.1 Hz originating from systemic physiological processes. While sLFO signals in the brain have been shown to travel with blood in numerous studies, their behavior in the spinal cord (SC) remains unexplored. This study characterizes the coupling between brain‐sLFO and SC‐sLFO signals. Understanding brain‐SC‐coupling is pivotal for unraveling the vascular continuity of the central nervous system, which plays a crucial role in SC‐injury pathophysiology. BOLD signal extraction involved registering structural masks to fMRI space to obtain average time series from the brain, SC, and superior sagittal sinus. The sLFOs of the time series were cross‐correlated to determine vascular delays and analyzed for band power. It is found that the SC‐sLFO signal comprises two components relative to the brain, showing opposite correlation polarity and varying delays. These findings suggest that highly oxygenated blood arrives at the spinal cord before arriving at the brain, and some component of the brain's venous output circulates to or near to the spinal cord later, likely due to unique arterial and venous pathways connecting the central nervous system. This insight offers a valuable imaging marker for future studies on the effects of SC injury on brain‐SC interconnectivity.