Citations

Clear

10 citation(s) found for "Khan, Abraham".

Gatherings in Esophagology: Innovations and Future Directions in the Diagnosis and Management of Reflux Disease
Cable, Jennifer, Giuli, R, Fox, Mark , Rosen, Rachel L., Valdovinos‐García, Luis R., Siboni, Stefano, Clarke, John O. , Samuels, Tina L. , Scarpignato, Carmelo , Fass, Ronnie, Remes-Troche, José María, Khan, Abraham, Rahman, Afrin Kamal, Lynch, Kristle L. , Jodorkovsky, Daniela , Vela, Marcelo F. , Vandenberg, Alexandra, Kuo, Braden, Ergün, Pelin , Jirapinyo, Pichamol, Asti, Emanuele, Tolone, Salvatore, Salvador, Renato , Sozzi, Marco, Husain, Inna, Wu, J. , Hobson, Anthony, Sharma, Nirmal , Gyawali, C. Prakash, Sifrim, Daniel, Savarino, E V, Bortoli, Nicola De, Rogers, Benjamin D. , Clarke, J , Valdovinos-García, Luis R. , Siboni, Stefano , Johnston, Nikki , Stein, Ellen M. , Fass, Ronnie , Remes Troche, José M , Kuo, Braden , Jirapinyo, Pichamol , Asti, Emanuele , Sheu, Eric Garland , Sozzi, Marco , Hobson, Anthony, Lo, Wai–Kit , Duncan, Daniel R. , Gyawali, C. Prakash , Chan, Walter W. , Sifrim, Daniel

Mayo Clinic

Annals of the New York Academy of Sciences | March 12, 2026 | Volume: 1557 | Issue: 1 | Pages: No page available

10.1111/nyas.70225 | PMID 41817458 Get It

ABSTRACT Recent advances in the diagnosis and management of reflux disease were the central focus of the inaugural Gatherings in Esophagology (GiE), which convened experts across gastroenterology, surgery, otolaryngology, pulmonology, and basic research. The sessions highlighted innovations in reflux monitoring—including high‐resolution manometry, wireless pH monitoring, and novel salivary biomarkers—while critically evaluating their diagnostic accuracy and clinical utility. Presentations explored the limitations of traditional proton‐pump inhibitor therapy, the emergence of potassium‐competitive acid blockers as a new class of acid suppressants, and the evolving role of adjunctive treatments such as mucosal protectants, reflux reducers, and neuromodulators for refractory symptoms. The discourse extended to advanced interventional procedures, including transoral incisionless fundoplication, magnetic sphincter augmentation, and the RefluxStop device, with discussion of patient selection, efficacy, and complication management. Discussants emphasized the pathophysiology and management of extraesophageal manifestations of reflux, the interplay between reflux and pulmonary disease, and the diagnostic challenges in pediatric populations. The meeting also addressed the integration of behavioral therapies, the role of the microbiome, and the application of artificial intelligence in reflux diagnostics. Collectively, these insights underscore a shift toward precision medicine in reflux disease, emphasizing individualized diagnostic strategies and tailored therapeutic approaches to improve patient outcomes.
Interrater Reliability of Functional Lumen Imaging Probe Panometry and High-Resolution Manometry for the Assessment of Esophageal Motility Disorders
Chen, Joan W. , Khan, Abraham, Chokshi, Reena V. , Clarke, John O. , Garza, Jose M. , Gupta, Milli , Gyawali, C. Prakash , Jain, Anand , Katz, Philip O. , Konda, Vani J. , Lazarescu, Adriana , Lynch, Kristle L. , Schnoll‐Sussman, Felice , Vela, Marcelo F. , Schauer, Jacob M. , Pandolfino, John E. , Carlson, Dustin A. , Clarke, J , Gyawali, C P , Chen, Joan , Khan, Abraham, Fass, Ronnie , Spechler, Stuart Jon , Yadlapati, Rena , Kahrilas, Peter J.

Mayo Clinic

American Journal of Gastroenterology | April 12, 2023 | Volume: 118 | Issue: 8 | Pages: 1334-1343

10.14309/ajg.0000000000002285 | PMID 37042784 Get It

INTRODUCTION: High-resolution manometry (HRM) and functional lumen imaging probe (FLIP) are primary and/or complementary diagnostic tools for the evaluation of esophageal motility. We aimed to assess the interrater agreement and accuracy of HRM and FLIP interpretations. METHODS: Esophageal motility specialists from multiple institutions completed the interpretation of 40 consecutive HRM and 40 FLIP studies. Interrater agreement was assessed using intraclass correlation coefficient (ICC) for continuous variables and Fleiss' κ statistics for nominal variables. Accuracies of rater interpretation were assessed using the consensus of 3 experienced raters as the reference standard. RESULTS: Fifteen raters completed the HRM and FLIP studies. An excellent interrater agreement was seen in supine median integral relaxation pressure (ICC 0.96, 95% confidence interval 0.95–0.98), and a good agreement was seen with the assessment of esophagogastric junction (EGJ) outflow, peristalsis, and assignment of a Chicago Classification version 4.0 diagnosis using HRM (κ = 0.71, 0.75, and 0.70, respectively). An excellent interrater agreement for EGJ distensibility index and maximum diameter (0.91 [0.90–0.94], 0.92 [0.89–0.95]) was seen, and a moderate-to-good agreement was seen in the assignment of EGJ opening classification, contractile response pattern, and motility classification (κ = 0.68, 0.56, and 0.59, respectively) on FLIP. Rater accuracy for Chicago Classification version 4.0 diagnosis on HRM was 82% (95% confidence interval 78%–84%) and for motility diagnosis on FLIP Panometry was 78% (95% confidence interval 72%–81%). DISCUSSION: Our study demonstrates high levels of interrater agreement and accuracy in the interpretation of HRM and FLIP metrics and moderate-to-high levels for motility classification in FLIP, supporting the use of these approaches for primary or complementary evaluation of esophageal motility disorders.
Inter‐ and intra‐rater agreement of interpretation of functional lumen imaging probe in healthy subjects
Yadlapati, Rena , Gyawali, C. Prakash , Carlson, Dustin A. , Pandolfino, John E. , Fass, Ronnie , Lin, Haiying, Richter, Joel E. , Vela, Marcelo F. , Vaezi, Michael F. , Clarke, John O. , Khan, Abraham , Vela, Marcelo F , Clarke, J , Gyawali, C P , Fass, Ronnie , Khan, Anzalee

Mayo Clinic

Neurogastroenterology & Motility | December 8, 2022 | Volume: 35 | Issue: 3 | Pages: No page available

10.1111/nmo.14505 | PMID 36480408 Get It

AbstractBackgroundThe functional lumen imaging probe (FLIP) evaluates esophagogastric junction (EGJ) opening and esophageal contractility. Both post hoc and real‐time analyses are possible, but reproducibility and reliability of analysis remain undefined. This study assesses inter‐ and intra‐rater agreement of normative FLIP measurements among novice and experienced users.MethodsEight motility experts from different institutions independently evaluated de‐identified video recordings from 27 asymptomatic healthy subjects using FLIP. Interpretation methods simulating a post‐procedure and a live procedure setting were tested. Novice FLIP users (n = 3) received training prior to post‐procedure interpretation. Experienced FLIP users (n = 5) interpreted using both methods. Users recorded maximum EGJ and distal esophageal body diameter, distensive pressure, and EGJ distensibility index (EGJ‐DI), at balloon fill volumes of 50‐, 60‐, and 70 ml, as well as repetitive antegrade contractions (RACs). Inter‐ and intra‐rater agreements of diameters, distensive pressure and EGJ‐DI were assessed by intra‐class correlation coefficient (ICC) and Pearson's correlation coefficient (PCC). Percentage agreement evaluated inter‐ and intra‐rater reliability for RACs.Key ResultsNovice and experienced users acquired normative FLIP metrics. Good‐to‐excellent inter‐ and intra‐rater reliability were achieved for all variables at 60 ml balloon fill volumes. Median parameters at 60 ml balloon fill volume were as follows: EGJ‐DI 5.5 mm2/mmHg, maximum EGJ diameter 18.6 mm, distensive pressure at maximum EGJ diameter 48.1 mmHg, and distal esophageal body diameter 19.5 mm.Conclusions and InferencesNormative FLIP parameters can be reliably extracted from FLIP videos using both real‐time and post hoc analyses, with high reliability between experienced and novice users.
Clinical role of ambulatory reflux monitoring in PPI non‐responders: recommendation statements
Yadlapati, Rena , Gawron, Andrew J. , Gyawali, C. Prakash , Chen, Joan W. , Clarke, John O. , Jain, Anand , Lynch, Kristle L. , Khan, Abraham, Katz, Philip O. , Katzka, David A. , Richter, Joel E. , Schnoll‐Sussman, Felice , Vaezi, Michael F. , Vela, Marcelo F. , Pandolfino, John E. , Chen, Joan , Katzka, D A , Richter, Joel , Vela, Marcelo, Clarke, J , Gyawali, C P , Fass, Ronnie , Khan, Abraham, Spechler, Stuart Jon

Mayo Clinic

Alimentary Pharmacology & Therapeutics | August 16, 2022 | Volume: 56 | Issue: 8 | Pages: 1274-1283

10.1111/apt.17180 | PMID 35971888 Get It

Summary Background Optimal ambulatory reflux monitoring methodology in symptomatic reflux patients continues to be debated. Aims To utilise published literature and expert opinion to develop recommendation statements addressing use of ambulatory reflux monitoring in clinical practice Methods The RAND Appropriateness Method (RAM) was utilised among 17 experts with discussion, revision and two rounds of ranking of recommendation statements. Ambulatory reflux monitoring protocol, methodology and thresholds ranked as appropriate by ≥80% of panellists met the criteria for appropriateness. Results Prolonged (96‐h recommended) wireless pH monitoring off proton pump inhibitor (PPI) was identified as the appropriate diagnostic tool to assess the need for acid suppression in patients with unproven gastro‐oesophageal reflux disease (GERD) and persisting typical reflux symptoms despite once‐daily PPI. Acid exposure time (AET) <4.0% on all days of monitoring with negative reflux‐symptom association excludes GERD and does not support ongoing PPI treatment. Conversely, AET >6.0% across ≥2 days is conclusive evidence for GERD and supports treatment for GERD, while AET >10% across ≥2 days identifies severe acid burden that supports escalation of anti‐reflux treatment. In previously proven GERD, impedance‐pH monitoring on PPI is helpful in defining refractory GERD and mechanisms of continued symptoms; the presence of <40 reflux events, AET <2.0% and a negative reflux‐symptom association does not support escalation of anti‐reflux treatment. In contrast, AET > 4.0% and positive reflux‐symptom association support escalation of anti‐reflux treatment, including use of invasive therapeutics. Conclusions Statements meeting appropriateness for average clinical care have been identified when utilising reflux monitoring in patients with typical reflux symptoms and PPI non‐response.
Variability in endoscopic assessment of Nissen fundoplication wrap integrity and hiatus herniation
Song, Erin J. , Yadlapati, Rena , Chen, Joan W. , Parish, Alice , Whitson, Matthew J. , Ravi, Karthik , Patel, Amit , Carlson, Dustin A. , Khan, Abraham, Niedzwiecki, Donna , Leiman, David A. , Patel, A , Niedzwiecki, Donna , Ravi, Karthik , Khan, Abraham

Mayo Clinic

Diseases of the Esophagus | December 29, 2021 | Volume: 35 | Issue: 5 | Pages: No page available

10.1093/dote/doab078 | PMID 34963133 Get It

Summary Background Upper endoscopy (EGD) is frequently performed in patients with esophageal complaints following anti-reflux surgery such as fundoplication. Endoscopic evaluation of fundoplication wrap integrity can be challenging. Our primary aim in this pilot study was to evaluate the accuracy and confidence of assessing Nissen fundoplication integrity and hiatus herniation among gastroenterology (GI) fellows, subspecialists, and foregut surgeons. Methods Five variations of post-Nissen fundoplication anatomy were included in a survey of 20 sets of EGD images that was completed by GI fellows, general GI attendings, esophagologists, and foregut surgeons. Accuracy, diagnostic confidence, and inter-rater agreement across providers were evaluated. Results There were 31 respondents in the final cohort. Confidence in pre-survey diagnostics significantly differed by provider type (mean confidence out of 5 was 1.8 for GI fellows, 2.7 for general GI attendings, 3.6 for esophagologists, and 3.6 for foregut surgeons, P = 0.01). The mean overall accuracy was 45.9%, which significantly differed by provider type with the lowest rate among GI fellows (37%) and highest among esophagologists (53%; P = 0.01). The accuracy was highest among esophagologists across all wrap integrity variations. Inter-rater agreement was low across wrap integrity variations (Krippendorf’s alpha &lt;0.30), indicating low to no agreement between providers. Conclusion In this multi-center survey study, GI fellows had the lowest accuracy and confidence in assessing EGD images after Nissen fundoplication, whereas esophagologists had the highest. Diagnostic confidence varied considerably and inter-rater agreement was poor. These findings suggest experience may improve confidence, but highlight the need to improve the evaluation of fundoplication wraps.
Classifying Esophageal Motility by FLIP Panometry: A Study of 722 Subjects With Manometry
Carlson, Dustin A. , Gyawali, C. Prakash , Khan, Abraham, Chen, Joan W. , Chokshi, Reena V. , Clarke, John O. , Garza, Jose M. , Jain, Anand , Katz, Philip O. , Konda, Vani J. , Lynch, Kristle L. , Schnoll‐Sussman, Felice , Vela, Marcelo F. , Prescott, Jacqueline, Baumann, Alexandra J. , Donnan, Erica N. , Pandolfino, John E. , Clarke, J , Gyawali, C P , Khan, Abraham, Yadlapati, Rena , Spechler, Stuart Jon , Kou, Wenjun , Kahrilas, Peter J.

Mayo Clinic

American Journal of Gastroenterology | October 20, 2021 | Volume: 116 | Issue: 12 | Pages: 2357-2366

10.14309/ajg.0000000000001532 | PMID 34668487 Get It

INTRODUCTION: Functional luminal imaging probe (FLIP) panometry can evaluate esophageal motility in response to sustained esophageal distension at the time of sedated endoscopy. This study aimed to describe a classification of esophageal motility using FLIP panometry and evaluate it against high-resolution manometry (HRM) and Chicago Classification v4.0 (CCv4.0). METHODS: Five hundred thirty-nine adult patients who completed FLIP and HRM with a conclusive CCv4.0 diagnosis were included in the primary analysis. Thirty-five asymptomatic volunteers (“controls”) and 148 patients with an inconclusive CCv4.0 diagnosis or systemic sclerosis were also described. Esophagogastric junction (EGJ) opening and the contractile response (CR) to distension (i.e., secondary peristalsis) were evaluated with a 16-cm FLIP during sedated endoscopy and analyzed using a customized software program. HRM was classified according to CCv4.0. RESULTS: In the primary analysis, 156 patients (29%) had normal motility on FLIP panometry, defined by normal EGJ opening and a normal or borderline CR; 95% of these patients had normal motility or ineffective esophageal motility on HRM. Two hundred two patients (37%) had obstruction with weak CR, defined as reduced EGJ opening and absent CR or impaired/disordered CR, on FLIP panometry; 92% of these patients had a disorder of EGJ outflow per CCv4.0. DISCUSSION: Classifying esophageal motility in response to sustained distension with FLIP panometry parallels the swallow-associated motility evaluation provided with HRM and CCv4.0. Thus, FLIP panometry serves as a well-tolerated method that can complement, or in some cases be an alternative to HRM, for evaluating esophageal motility disorders.
Chicago Classification update (version 4.0): Technical review on diagnostic criteria for achalasia
Khan, Anzalee , Yadlapati, Rena , Gonlachanvit, Sutep , Katzka, David A. , Vaezi, Michael F. , Vela, Marcelo F. , Pandolfino, John E. , Khan, Abraham , Vela, Marcelo, Park, Moo In

Mayo Clinic

Neurogastroenterology & Motility | July 1, 2021 | Volume: 33 | Issue: 7 | Pages: No page available

10.1111/nmo.14182 | PMID 34190376 Get It

Abstract The recommended diagnostic criteria for achalasia have been recently updated by Chicago Classification version 4.0 (CCv4.0), the widely accepted classification scheme for esophageal motility disorders using metrics from high‐resolution manometry (HRM). CCv4.0 continued upon prior versions by subtyping achalasia into type I, type II, and type III on HRM. The achalasia subgroup of the CCv4.0 Working Group developed both conclusive and inconclusive statements for the HRM diagnoses of achalasia subtypes. Conclusive achalasia on HRM is defined as an abnormal median integrated relaxation pressure (IRP) in the primary position of wet swallows along with 100% failed peristalsis, with type I achalasia having 100% failed peristalsis without panesophageal pressurization (PEP), type II achalasia with PEP in at least 20% of swallows, and type III achalasia having at least 20% of swallows premature with no appreciable peristalsis. An inconclusive HRM diagnosis of achalasia can arise when there is an integrated relaxation pressure (IRP) that is borderline or at the upper limit of normal in at least one position, there is an abnormal IRP in both positions but evidence of peristalsis with PEP or premature swallows, or there is peristalsis in the secondary position after apparent achalasia in the primary position. In patients with dysphagia and an inconclusive HRM diagnosis of achalasia, supportive testing beyond HRM such as a timed barium esophagram (TBE) for functional lumen imaging probe (FLIP) is recommended. The review recommends a diagnostic algorithm for achalasia, discusses therapeutic options for the disease, and outlines future needs on this topic.
Esophageal motility disorders on high‐resolution manometry: Chicago classification version 4.0 ©
Yadlapati, Rena , Fox, Mark , Bredenoord, Albert J. , Gyawali, C. Prakash , Roman, Sabine , Babaei, Arash , Mittal, Ravinder K. , Rommel, Nathalie , Savarino, Edoardo , Smout, A. J. P. M. , Vaezi, Michael F. , Akiyama, Junichi, Bhatia, Shobna , Carlson, Dustin A. , Chen, Joan W. , Cisternas, Daniel , Cock, Charles , Defilippi, Claudia, Gonlachanvit, Sutep , Hebbard, Geoffrey , Jung, Kee Wook , Katz, Philip O. , Katzka, David A. , Khan, Anzalee , Kohn, Geoffrey P. , Lazarescu, Adriana , Lengliner, Johannes, Omari, Taher , Pohl, Daniel , Richter, Joel E. , Serra, Jordi , Sweis, Rami , Tack, Jan , Tatum, Roger P. , Vela, Marcelo F. , Wu, Justin C. Y. , Xiao, Yinglian , Pandolfino, John E. , Fox, Mark R , Gyawali, C P , Roman, S , Babaei, Arash , Mittal, Ravinder K , Sifrim, Daniel , Smout, André , Zerbib, Frank , Bor, Serhat , Carlson, Dustin A , Cisternas, Daniel , Cock, Charles , de Bortoli, Nicola , Fass, Ronnie , Ghoshal, Uday C , Jung, Kee Wook , Khan, Abraham , Omari, Taher , Park, Moo In , Penagini, Roberto , Serra, Jordi , Tack, Jan , Savarino, Edoardo , Kahrilas, Peter J. , Bor, Serhat , Coss‐Adame, Enrique , Bortoli, Nicola de , Fass, Ronnie , Ghoshal, Uday C. , Hani, Albis Cecilia , Mittal, Sumeet K. , Penagini, Roberto , Tutuian, Radu I. , Wong, Reuben K.

Mayo Clinic

Neurogastroenterology & Motility | December 29, 2020 | Volume: 33 | Issue: 1 | Pages: No page available

10.1111/nmo.14058 | PMID 33373111 Get It

Abstract Chicago Classification v4.0 (CCv4.0) is the updated classification scheme for esophageal motility disorders using metrics from high‐resolution manometry (HRM). Fifty‐two diverse international experts separated into seven working subgroups utilized formal validated methodologies over two‐years to develop CCv4.0. Key updates in CCv.4.0 consist of a more rigorous and expansive HRM protocol that incorporates supine and upright test positions as well as provocative testing, a refined definition of esophagogastric junction (EGJ) outflow obstruction (EGJOO), more stringent diagnostic criteria for ineffective esophageal motility and description of baseline EGJ metrics. Further, the CCv4.0 sought to define motility disorder diagnoses as conclusive and inconclusive based on associated symptoms, and findings on provocative testing as well as supportive testing with barium esophagram with tablet and/or functional lumen imaging probe. These changes attempt to minimize ambiguity in prior iterations of Chicago Classification and provide more standardized and rigorous criteria for patterns of disorders of peristalsis and obstruction at the EGJ.
The functional lumen imaging probe in gastrointestinal disorders: the past, present, and future
Clarke, John O. , Ahuja, Nitin K. , Fernandez‐Becker, Nielsen , Kamal, A. N. , Khan, Abraham, Lynch, Kristie L., Vela, Marcelo F. , Clarke, J , Gregersen, Hans N. , Kamal, Afrin N., Khan, Abraham

Mayo Clinic

Annals of the New York Academy of Sciences | August 28, 2020 | Volume: 1482 | Issue: 1 | Pages: 16-25

10.1111/nyas.14463 | PMID 32814368 Get It

AbstractThe functional lumen imaging probe (FLIP) is a diagnostic tool that utilizes impedance planimetry to allow the assessment of luminal diameter and distensibility. It has been used primarily in esophageal diseases, in particular, in the assessment of achalasia, esophagogastric junction outflow obstruction, and eosinophilic esophagitis (EoE). The usage and publications have increased over the past decade and it is now an essential tool in the armamentarium of the esophagologist. Indications are emerging outside of the esophagus, in particular with regard to gastroparesis. Our paper will review the history of FLIP, optimal current usage, data for key esophageal disorders (including achalasia, reflux, and EoE), data for nonesophageal disorders, and our sense as to whether FLIP is ready for prime time, as well as gaps in evidence and suggestions for future research.
Use of the Functional Lumen Imaging Probe in Clinical Esophagology
Savarino, Edoardo , Pietro, Massimiliano di , Bredenoord, Albert J. , Carlson, Dustin A. , Clarke, John O. , Khan, Abraham, Vela, Marcelo F. , Pohl, Daniel , Pandolfino, John E. , Gyawali, C. Prakash , Khan, Anzalee , Clarke, J , Gyawali, C P , Khan, Abraham , Savarino, Edoardo , Khan, Abraham, Yadlapati, Rena , Roman, Sabine

Mayo Clinic

American Journal of Gastroenterology | August 1, 2020 | Volume: 115 | Issue: 11 | Pages: 1786-1796

10.14309/ajg.0000000000000773 | PMID 33156096 Get It

The functional lumen imaging probe (FLIP) measures luminal dimensions using impedance planimetry, performed most often during sedated upper endoscopy. Mechanical properties of the esophageal wall and opening dynamics of the esophagogastric junction (EGJ) can be objectively evaluated in esophageal motor disorders, eosinophilic esophagitis, esophageal strictures, during esophageal surgery and in postsurgical symptomatic states. Distensibility index, the ratio of EGJ cross sectional area to intraballoon pressure, is the most useful FLIP metric. Secondary peristalsis from balloon distension can be displayed topographically as repetitive anterograde or retrograde contractile activity in the esophageal body, similar to high-resolution manometry. Real-time interpretation and postprocessing of FLIP metadata can complement the identification of esophageal outflow obstruction and achalasia, especially when findings are inconclusive from alternate esophageal tests in symptomatic patients. FLIP can complement the diagnosis of achalasia when manometry and barium studies are inconclusive or negative in patients with typical symptoms. FLIP can direct adequacy of disruption of the EGJ in achalasia when used during and immediately after myotomy and pneumatic dilation. Lumen diameter measured using FLIP in eosinophilic esophagitis and in complex strictures can potentially guide management. An abbreviated modification of the Grading of Recommendations Assessment, Development, and Evaluation was used to determine the quality of available evidence and recommendations regarding FLIP utilization. FLIP metrics that are diagnostic or suggestive of an abnormal motor pattern and metrics that define normal esophageal physiology were developed by consensus and are described in this review.