Citations

Clear

7 citation(s) found for "Costamagna, Guido".

Correction: Devices and techniques for bariatric and metabolic endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Technical and Technology Review
Boškoski, Ivo , Shamah, Steven, Bove, Vincenzo , Siena, Martina De , Huberty, Vincent , Perretta, Silvana , Sharaiha, Reem Z. , De Siena, Martina , Huberty, Vincent , Sharaiha, Reem Z , Facciorusso, Antonio , Fuccio, Lorenzo , Costamagna, Guido , Matteo, Maria Valeria , Dayyeh, Barham K. Abu , Maselli, Roberta , Pontecorvi, Valerio , Stier, Christine , Facciorusso, Antonio , Fuccio, Lorenzo

Mayo Clinic

Endoscopy | November 7, 2025 | Volume: 57 | Issue: 11 | Pages: C19-C19

10.1055/a-2739-2796 | PMID 41198053 Get It

Devices and techniques for bariatric and metabolic endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Technical and Technology Review
Boškoski, Ivo , Shamah, Steven, Bove, Vincenzo , Siena, Martina De , Huberty, Vincent , Perretta, Silvana , Pontecorvi, Valerio , Stier, Christine , Sharaiha, Reem Z. , De Siena, Martina , Huberty, Vincent , Sharaiha, Reem Z , Facciorusso, Antonio , Fuccio, Lorenzo , Costamagna, Guido , Matteo, Maria Valeria , Dayyeh, Barham K. Abu , Maselli, Roberta , Facciorusso, Antonio , Fuccio, Lorenzo

Mayo Clinic

Endoscopy | July 9, 2025 | Volume: 57 | Issue: 09 | Pages: 1033-1055

10.1055/a-2630-2062 | PMID 40628371 Get It

Abstract Endoscopic bariatric and metabolic therapies (EBMTs) are increasingly recognized as valuable tools for managing obesity and related metabolic disorders. As the prevalence of obesity continues to rise globally, there is a growing demand for effective, safe, and less invasive treatment options. This review provides a comprehensive summary of the available EBMTs, including both stomach-targeted and small-bowel-targeted devices. The review details the various devices, outlines the techniques for their proper use, and discusses their indications. It also presents data on their efficacy and safety, and the management of adverse events and weight regain, as well as anticipated future developments. The paper emphasizes the necessity for additional high quality randomized controlled trials and long-term outcome data to better define the role of these therapies within obesity treatment protocols. Overall, this review serves as an authoritative resource for endoscopists, bariatric specialists, and the wider healthcare community involved in obesity care, promoting best practices and guiding the appropriate implementation of EBMTs in clinical settings.
Computer‐aided detection for esophageal achalasia (with video)
Shiwaku, Hironari , Misawa, Masashi , Inoue, Haruhiro , Boškoski, Ivo , Shimamura, Yuto , Ikebuchi, Yuichiro , Ominami, Masaki , Htet, Hein , Messmann, H, Colosso, Bianca Maria Quarta , Repici, Alessandro , Stavropoulos, Stavros N. , Bechara, Robert , Sethi, Amrita, Beyna, Torsten , Santi, Esperanza Grace , Sharma, Prateek , Eleftheriadis, Nikolas, Minami, Hitomi, Haber, Gregory , Seewald, Stefan , Shiwaku, Akio, Shiwaku, Yoshiyuki, Mori, Kensaku, Costamagna, Guido , Shimamura, Yuto , Ikebuchi, Yuichiro , Iwaya, Yugo , Htet, Hein Myat Thu , Colosso, Bianca Maria Quarta , Bechara, Robert , Kahaleh, Michel , Beyna, Torsten , Jiang, Kai, Oda, Masahiro , Familiari, Pietro , Hayee, Bu , Ho, Khek Yu , So, Jimmy Bok Yan , Bhandari, Pradeep , Grimes, Kevin L. , Maselli, Roberta , Hassan, Cesare , Fukami, Norio , Kahaleh, Michel , Sethi, Amrita , Neuhaus, Horst Ekkehard , Chiu, Philip Wai Yan , Eleftheriadis, Nikolas, Draganov, Peter V. , Mori, Kensaku , Kudo, Shin‐ei , Hasegawa, Suguru

Mayo Clinic

Digestive Endoscopy | June 12, 2025 | Volume: 37 | Issue: 8 | Pages: 851-861

10.1111/den.15028 | PMID 40506418 Get It

ObjectivesAchalasia is an esophageal motility disorder that impairs quality of life and is often missed (20–50%) on endoscopy. A newly developed computer‐aided detection (CAD) software has shown high accuracy for achalasia diagnosis in preclinical settings. However, its benefit in a clinical setting remains unclear.MethodsBetween February and August 2023, 83 endoscopists from 27 centers assessed 50 randomized endoscopic videos (25 achalasia, 25 nonachalasia) without and with CAD. Endoscopists assessed videos without CAD, then with CAD after 2 months. The primary end‐point was improvement in sensitivity for nonexperienced endoscopists (no endoscopic experience of achalasia). Sensitivity, specificity, and accuracy with and without CAD were compared using the McNemar test.ResultsSensitivity for diagnosing achalasia increased significantly with CAD, rising from 74.2% (95% confidence interval [CI] 72.2–76.0%) to 91.2% (95% CI 89.9–92.4%) for all readers, showing a difference of 17.1% (95% CI 15.1–19.0%). Specifically, sensitivity improved from 66.9% (95% CI 63.6–70.0%) to 91.9% (95% CI 89.9–93.6%) among nonexperienced endoscopists, resulting in a difference of 25.0% (95% CI 21.7–28.4%), and from 79.5% (95% CI 77.1–81.8%) to 90.8% (95% CI 89.0–92.3%) among experienced endoscopists (endoscopic experience of at least one achalasia case), with a difference of 11.3% (95% CI 8.9–13.6%). Accuracy and specificity improved significantly with CAD assistance, regardless of reader's experience.ConclusionCAD improves achalasia detection by 17%, confirming preclinical results. The benefit was higher for nonexperienced endoscopists. CAD assistance may lead to prompt and effective treatment, minimizing the risk of false‐negative diagnosis in clinical practice.Trial registrationThis study was registered in the University Hospital Medical Information Network Clinical Trial Registry (https://www.umin.ac.jp/ctr/) number: UMIN000053047.
Global prospective case series of ERCPs using a single-use duodenoscope
Bruno, Marco J. , Beyna, Torsten , Carr‐Locke, David L. , Chahal, Prabhleen , Costamagna, Guido , Devereaux, Benedict , Giovannini, Marc, Khor, Christopher , Lau, James Y., May, Gary R. , Muthusamy, V. Raman , Petersen, Bret T. , Raijman, Isaac , Reddy, D. Nageshwar , Ross, Andrew S., Sejpal, Divyesh V., Sherman, Stuart , Siddiqui, Uzma D. , Ziady, Christopher, Peetermans, Joyce , Rousseau, Matthew , Slivka, Adam, Group, EXALT Single-use Duodenoscope Study, Fichera, Alessandro , Pleskow, Douglas , Goenka, Mahesh Kumar , Patel, Sandeep , Petersen, Bret T. , Pleskow, Douglas K. , Repici, Alessandro , Group, EXALT Single-use Duodenoscope Study

Mayo Clinic

Endoscopy | July 18, 2023 | Volume: 55 | Issue: 12 | Pages: 1103-1114

10.1055/a-2131-7180 | PMID 37463599 Get It

Background The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. Methods 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ≥ 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). Results Among 551 patients, 236 (42.8 %) were aged > 65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3–4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. Conclusions In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.
Use of probe‐based confocal laser endomicroscopy (pCLE) in gastrointestinal applications. A consensus report based on clinical evidence
Wang, Kenneth K. , Carr‐Locke, David L. , Singh, Satish K. , Neumann, Helmut , Bertani, Helga , Galmiche, Jean-Paul, Arsenescu, Razvan, Caillol, Fabrice , Chang, Kenneth J. , Chaussade, Stanislas, Coron, Emmanuel , Dlugosz, Aldona , Gan, S. Ian , Giovannini, Marc, Gress, Frank G., Haluszka, Oleh, Kahaleh, Michel , Konda, Vani J. , Prat, Frédéric, Sharma, Prateek , Slivka, Adam, Wolfsen, Herbert C. , Zfass, Alvin M., Costamagna, Guido , Ho, Khek Yu , Shah, Raj J. , Kahaleh, Michel

Mayo Clinic

United European Gastroenterology Journal | January 14, 2015 | Volume: 3 | Issue: 3 | Pages: 230-254

10.1177/2050640614566066 | PMID 26137298 Get It

Background Probe‐based confocal laser endomicroscopy (pCLE) provides microscopic imaging during an endoscopic procedure. Its introduction as a standard modality in gastroenterology has brought significant progress in management strategies, affecting many aspects of clinical care and requiring standardisation of practice and training. Objective This study aimed to provide guidance on the standardisation of its practice and training in Barrett's oesophagus, biliary strictures, colorectal lesions and inflammatory bowel diseases. Methods Initial statements were developed by five group leaders, based on the available clinical evidence. These statements were then voted and edited by the 26 participants, using a modified Delphi approach. After two rounds of votes, statements were validated if the threshold of agreement was higher than 75%. Results Twenty‐six experts participated and, among a total of 77 statements, 61 were adopted (79%) and 16 were rejected (21%). The adoption of each statement was justified by the grade of evidence. Conclusion pCLE should be used to enhance the diagnostic arsenal in the evaluation of these indications, by providing microscopic information which improves the diagnostic performance of the physician. In order actually to implement this technology in the clinical routine, and to ensure good practice, standardised initial and continuing institutional training programmes should be established.
Defining esophageal landmarks, gastroesophageal reflux disease, and Barrett's esophagus
DeVault, Kenneth R. , McMahon, Barry P. , Marchese, Michele , Hejazi, Reza , McCallum, Richard W. , Savarino, Vincenzo , Zentilin, Patrizia , Savarino, Edoardo , Thomson, Mike , Souza, Rhonda F. , Donohoe, Claire L. , O’Farrell, Naoimh J. , Reynolds, John V. , DeVault, Kenneth, Çelebi, Altay , Costamagna, Guido , Clarke, John O. , Savarino, Edoardo

Mayo Clinic

Annals of the New York Academy of Sciences | January 6, 2014 | Volume: 1300 | Issue: 1 | Pages: 278-295

10.1111/nyas.12253 | PMID 24117649 Get It

The following paper on gastroesophageal reflux disease (GERD) and Barrett's esophagus (BE) includes commentaries on defining esophageal landmarks; new techniques for evaluating upper esophageal sphincter (UES) tone; differential diagnosis of GERD, BE, and hiatal hernia (HH); the use of high‐resolution manometry for evaluation of reflux; the role of fundic relaxation in reflux; the use of 24‐h esophageal pH–impedance testing in differentiating acid from nonacid reflux and its potential inclusion in future Rome criteria; classification of endoscopic findings in GERD; the search for the cell origin that generates BE; and the relationship between BE, Barrett's carcinoma, and obesity.