Citations

Clear

5 citation(s) found for "Abudan, Anas".

Burden of arrhythmia in hospitalized HIV patients
Abudan, Anas , Vaidya, Vaibhav R. , Tripathi, Byomesh , Noseworthy, Peter A. , DeSimone, Daniel C. , Egbe, Alexander , Arora, Shilpkumar , Sridhar, Haarini , DeSimone, Christopher V. , Mulpuru, Siva K. , Deshmukh, Abhishek , Abudan, Anas A , Mulpuru, Siva K , Deshmukh, Abhishek J , Tripathi, Byomesh , Noseworthy, Peter A , DeSimone, Christopher V , DeSimone, Daniel C

Mayo Clinic

Clinical Cardiology | December 10, 2020 | Volume: 44 | Issue: 1 | Pages: 66-77

10.1002/clc.23506 | PMID 33295667 Get It

AbstractBackgroundThe improved life expectancy observed in patients living with human immunodeficiency virus (HIV) infection has made age‐related cardiovascular complications, including arrhythmias, a growing health concern.HypothesisWe describe the temporal trends in frequency of various arrhythmias and assess impact of arrhythmias on hospitalized HIV patients using the Nationwide Inpatient Sample (NIS).MethodsData on HIV‐related hospitalizations from 2005 to 2014 were obtained from the NIS database using International Classification of Diseases, 9th Revision (ICD‐9) codes. Data was further subclassified into hospitalizations with associated arrhythmias and those without. Baseline demographics and comorbidities were determined. Outcomes including in‐hospital mortality, cost of care, and length of stay were extracted. SAS 9.4 (SAS Institute Inc., Cary, NC) was utilized for analysis. A multivariable analysis was performed to identify predictors of arrhythmias among hospitalized HIV patients.ResultsAmong 2 370 751 HIV‐related hospitalizations identified, the overall frequency of any arrhythmia was 3.01%. Atrial fibrillation (AF) was the most frequent arrhythmia (2110 per 100 000). The overall frequency of arrhythmias increased over time by 108%, primarily due to a 132% increase in AF. Arrhythmias are more frequent among older males, lowest income quartile, and nonelective admissions. Patients with arrhythmias had a higher in‐hospital mortality rate (9.6%). In‐hospital mortality among patients with arrhythmias decreased over time by 43.8%. The cost of care and length of stay associated with arrhythmia‐related hospitalizations were mostly unchanged.ConclusionsArrhythmias are associated with significant morbidity and mortality in hospitalized HIV patients. AF is the most frequent arrhythmia in hospitalized HIV patients.
Burden of Arrhythmia in Hospitalized HIV Patients
Abudan, Anas , Vaidya, Vaibhav, Tripathi, Byomesh , Egbe, Alexander , Arora, Shilpkumar , Sridhar, Haarini , DeSimone, Christopher V. , Mulpuru, Siva K. , Deshmukh, Abhishek , DeSimone, Christopher V , Noseworthy, Peter A. , DeSimone, Daniel C.

Mayo Clinic

No container title available | July 16, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159493215.58844465 Get It

Background: The improved life expectancy observed in patients living with Human Immunodeficiency Virus (HIV) infection has made age-related cardiovascular complications, including arrhythmias, a growing health concern. We describe the temporal trends in frequency of various arrhythmias and assess impact of arrhythmias on hospitalized HIV patients using the Nationwide Inpatient Sample (NIS) Methods and Results: Data on HIV-related hospitalizations from 2005 to 2014 were obtained from the NIS using International Classification of Diseases, 9th Revision (ICD-9) codes. Data was further subclassified into hospitalizations with associated arrhythmias and those without arrhythmia. Baseline demographics and comorbidities were determined. Outcomes including in-hospital mortality, cost of care, and length of stay were extracted. SAS 9.4 (SAS Institute Inc., Cary, North Carolina) was utilized for analysis. A multivariable analysis was performed to identify predictors of arrhythmias among hospitalized HIV patients. Among 2,370,751 HIV-related hospitalizations identified, the overall frequency of any arrhythmia was 3.01%. Atrial fibrillation (AF) was the most frequent arrhythmia (2110 per 100,000). The overall frequency of arrhythmias has increased over time by 108%, primarily due to a 132% increase in AF. Arrhythmias are more frequent among older males, lowest income quartile and non-elective admissions. Patients with arrhythmias had a higher in-hospital mortality rate (9.6%). In-hospital mortality among patients with arrhythmias has decreased over time by 43.8%. The cost of care and length of stay associated with arrhythmia-related hospitalizations were mostly unchanged. Conclusions: Arrhythmias are associated with significant morbidity and mortality in hospitalized HIV patients. AF is the most frequent arrhythmia in hospitalized HIV patients.
P4126Safety of magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices: A systematic review and meta-analysis
Padmanabhan, Deepak , Izath, A, Al‐Masry, Anas Abudan , Gamero, Sonia Fortin, Barout, Ahmad, Assaf, Yazan , Shetty, Devi Prasad , Asirvatham, S, Felmlee, Joel P. , Watson, Robert E. , Cha, Y, Friedman, Paul A. , Farwati, Medhat , Al-Masry, A, Kella, Danesh

Mayo Clinic

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz745.0698 Get It

Abstract Recent guideline statements approve the performance of magnetic resonance imaging (MRI) in patients with non-conditional cardiac implantable electronic devices (CIEDs) under certain closely monitored conditions. Data from current registries may have lower power to discern changes that may occur in the CIED after the MRI. Objective We aimed to systematically review the literature to identify the adverse events and significance of changes in device function associated with performing MRI in patients with CIEDs Methods A comprehensive literature search of the databases was performed between 1980- 2017. Two independent reviewers selected studies and extracted data. A random-effects model was used for meta-analysis. Results A total of 7,422 patients underwent 8,865 MRI studies. No death occurred post MRI. Clinical adverse events were extremely rare (mostly less than 1%) and are summarized in Table 1. No significant changes in the pooled mean effect size estimate was noted for the changes in the lead parameters (pacing threshold, sensing and impedance) Binary outcomes post magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices Outcome Sample size Number of patients Rate SE LL of CI UL of CI Death 7401 0 0 0 0 0 Atrial arrhythmia 7173 10 0.001 0.0004 0.0007 0.0024 Ventricular arrhythmia 7371 9 0.0012 0.0004 0.0006 0.0022 Oversensing 4981 17 0.0034 0.0008 0.0020 0.0053 Inhibition of pacing 7371 6 0.0008 0.0003 0.0003 0.0016 Lead Failure/Generator Failure 7475/7475 2/8 0.0002/0.0011 0.0001/0.0004 0.0001/0.0005 0.0009/0.002 Power on Reset 1388 105 0.0131 0.0014 0.0107 0.0161 Did not complete scan 6851 13 0.0019 0.0005 0.0011 0.0031 Chest pain 7080 11 0.0021 0.0004 0.0008 0.0027. Lead threshold rise (>0.5v/>50%-A/V) 5076/6246 12/16 0.0024/0.0026 0.0007/0.0006 0.0013/0.0015 0.0040/0.0041 Change in Battery voltage >0.04V 7132 42 0.0061 0.0009 0.0043 0.0079 Sensing decrease >50%-A/V 5087/5834 17/9 0.0033/0.0015 0.0008/0.0005 0.0020/0.0008 0.0052/0.0028 Impedance changes >50ohms/>50% 5810 22 0.0038 0.0008 0.0024 0.0057 Rise in cardiac enzymes 1703 26 0.0152 0.0030 0.0102 0.0219 A, atrial; V, ventricular; SE, standard Error; LL, lower limit; UL, upper limit; CI, Confidence intervals. Conclusions MRI in patients with non-conditional CIEDs can be performed with high degree of safety and low rate of clinical events when performed under standardized protocols Acknowledgement/Funding None
Safety and compatibility of smart device heart rhythm monitoring in patients with cardiovascular implantable electronic devices
Abudan, Anas, Isath, Ameesh , Ryan, J. , Henrich, Mark, Dugan, Jennifer , Ladewig, Dorothy J., Friedman, Paul A. , Abudan, Anas A , Ryan, James D , Henrich, Mark J, Dugan, Jennifer L, Dillon, John J, Friedman, Paul A , Attia, Zachi I. , Dillon, John

Mayo Clinic

Journal of Cardiovascular Electrophysiology | June 13, 2019 | Volume: 30 | Issue: 9 | Pages: 1602-1609

10.1111/jce.14024 | PMID 31190453 Get It

AbstractIntroductionEmerging medical technology has allowed for monitoring of heart rhythm abnormalities using smartphone compatible devices. The safety and utility of such devices have not been established in patients with cardiac implantable electronic devices (CIEDs). We sought to assess the safety and compatibility of the Food and Drug Administration‐approved AliveCor Kardia device in patients with CIEDs.Methods and ResultsWe prospectively recruited patients with CIED for a Kardia recording during their routine device interrogation. A recording was obtained in paced and nonpaced states. Adverse clinical events were noted at the time of recording. Electrograms (EGMs) from the cardiac device were obtained at the time of recording to assess for any electromagnetic interference (EMI) introduced by Kardia. Recordings were analyzed for quality and given a score of 3 (interpretable rhythm, no noise), 2 (interpretable rhythm, significant noise) or 1 (uninterpretable). A total of 251 patients were recruited (59% with a pacemaker and 41% with ICD). There were no adverse clinical events noted at the time of recording and no changes to CIED settings. Review of all EGMs revealed no EMI introduced by Kardia. Recordings were correctly interpreted in 90% of paced recordings (183 had a score of 3, 43 of 2, and 25 of 1) and 94.7% of nonpaced recordings (147 of 3, 15 of 2, and 9 of 1).ConclusionThe AliveCor Kardia device has an excellent safety profile when used in conjunction with most CIEDs. The quality of recordings was preserved in this population. The device, therefore, can be considered for heart rhythm monitoring in patients with CIEDs.
Percutaneous epicardial pacing using a novel transverse sinus device
Vaidya, Vaibhav R. , Sugrue, Alan , Padmanabhan, Deepak , Killu, Ammar M. , Naksuk, Niyada , Al‐Masry, Anas Abudan , Isath, Ameesh , Pedersen, Joanne, Yngsdal, Lisa, Ladewig, Dorothy J., Friedman, Paul A. , Asirvatham, Samuel J. , Asirvatham, Samuel J

Mayo Clinic

Journal of Cardiovascular Electrophysiology | June 8, 2018 | Volume: 29 | Issue: 9 | Pages: 1308-1316

10.1111/jce.13661 | PMID 29882395 Get It

AbstractBackgroundTransvenous lead implantation has multiple drawbacks and complications that can be overcome by epicardial lead placement. We aimed to design percutaneously implanted epicardial leads that are anchored through the transverse sinus (TS).Methods and resultsWe designed a novel multielectrode pacing device with four bipole electrode pairs. The device is advanced through the TS, with both ends externalized out of the pericardium. We tested the prototype in one proof‐of‐concept and 5 additional acute canine experiments.The TS device recorded ventricular and atrial electrograms. The median amplitude of near‐field ventricular electrograms was 3.3 mA (IQR 2.0–4.3) and of near‐field atrial electrograms was 2.1 mA (IQR 1.3–2.2). The median ventricular threshold (N = 30) was 1.1 mA (IQR 0.7–3.1) at a median pulse width of 0.5 ms (IQR 0.5–0.5). The median atrial threshold (N = 10) was 2.4 mA (IQR 1.1–7.8) at a median pulse width of 0.5 ms (IQR 0.5–0.9). Right and left ventricular and atrial pacing morphologies were noted while pacing electrodes adjacent to these chambers. Simultaneous left (LV) and right ventricular (RV) pacing showed reduction in QRS duration from 116 ms (RV) and 105 ms (LV) to 91 ms. On necropsy, the device was located in the TS in all animals. There were TS abrasions in one animal, and no other acute complications.ConclusionsThis study highlights a novel approach to epicardial pacing harnessing the unique anatomy of the transverse sinus as an anchoring point. Placement of this novel transverse sinus device was safe and feasible, with acceptable atrial and ventricular thresholds.