One of the technical limitations of surgeon-modified fenestrated stent grafts is the lack of a diameter-reducing wire, which facilitates catheterization of target branches if there are errors of device design, alignment, or implantation. This article describes a technique of adding a diameter-reducing wire to the modified TX2 fenestrated stent graft for compassionate use in aortic emergencies or high-risk patients who do not have access to manufactured devices. The modified Cook TX2 stent graft was created using reinforced fenestrations with gold nitinol markers. After the TX2 stent was fully unsheathed, one of the nitinol wires located in the inner cannula was withdrawn and redirected externally through and through the fabric of the stent graft. Each Z stent was constrained using the nitinol wire for support and two nonlocking polypropylene loops. The use of a diameter-reducing wire facilitates side branch catheterization by allowing longitudinal and rotational movement to the modified fenestrated stent graft in patients where there is misalignment between the fenestration and the origin of the target vessel.
Background— The Carotid Revascularization Endarterectomy Versus Stenting Trial (CREST) found a higher risk of stroke after carotid artery stenting and a higher risk of myocardial infarction (MI) after carotid endarterectomy. Methods and Results— Cardiac biomarkers and ECGs were performed before and 6 to 8 hours after either procedure and if there was clinical evidence of ischemia. In CREST, MI was defined as biomarker elevation plus either chest pain or ECG evidence of ischemia. An additional category of biomarker elevation with neither chest pain nor ECG abnormality was prespecified (biomarker+ only). Crude mortality and risk-adjusted mortality for MI and biomarker+ only were assessed during follow-up. Among 2502 patients, 14 MIs occurred in carotid artery stenting and 28 MIs in carotid endarterectomy (hazard ratio, 0.50; 95% confidence interval, 0.26 to 0.94; P =0.032) with a median biomarker ratio of 40 times the upper limit of normal. An additional 8 carotid artery stenting and 12 carotid endarterectomy patients had biomarker+ only (hazard ratio, 0.66; 95% confidence interval, 0.27 to 1.61; P =0.36), and their median biomarker ratio was 14 times the upper limit of normal. Compared with patients without biomarker elevation, mortality was higher over 4 years for those with MI (hazard ratio, 3.40; 95% confidence interval, 1.67 to 6.92) or biomarker+ only (hazard ratio, 3.57; 95% confidence interval, 1.46 to 8.68). After adjustment for baseline risk factors, both MI and biomarker+ only remained independently associated with increased mortality. Conclusions— In patients randomized to carotid endarterectomy versus carotid artery stenting, both MI and biomarker+ only were more common with carotid endarterectomy. Although the levels of biomarker elevation were modest, both events were independently associated with increased future mortality and remain an important consideration in choosing the mode of carotid revascularization or medical therapy. Clinical Trial Registration— URL: http://www.ClinicalTrials.gov . Unique identifier: NCT00004732.
AJR Teaching File: Incidental Breast Cancer Detected With 18F-FDG PET/CT
Response to Letter Regarding Article, “Attained Educational Level and Incident Atherothrombotic Events in Low- and Middle-Income Compared With High-Income Countries”