Citations

Showing 10 of 107964 citations.

Sex and Test Verification Bias
Roger, Véronique L. , Pellikka, Patricia A. , Bell, Malcolm R. , Chow, Charles W.H., Bailey, Kent R. , Seward, James B., Pellikka, Patricia A

Mayo Clinic

Circulation | June 12, 2012 | Volume: 95 | Issue: 2 | Pages: 405-410

10.1161/01.cir.95.2.405 | PMID 9008457 Get It

Background The use of exercise echocardiography for the diagnosis of coronary artery disease (CAD) has been validated in pilot studies but is not documented in clinical practice and in women comparatively with men. The objectives of this study were to determine the effects of sex and of test verification bias on the diagnostic performance of exercise echocardiography. Methods and Results Three thousand six hundred seventy-nine consecutive patients (1714 women, 1965 men) who underwent an exercise echocardiographic study were studied; the observed sensitivity, specificity, and correct classification rate were calculated among 340 patients (244 men, 96 women) who underwent angiography; to study the effect of test verification bias, sensitivity and specificity were estimated for all patients who underwent exercise echocardiography including those not referred to angiography. In the angiographic group, the prevalence of CAD was 60% in women and 80% in men. The observed sensitivity and specificity of exercise echocardiography was 78% and 44% in men and 79% and 37% in women. After adjustment for test verification bias, the estimated sensitivity was lower in women (32% versus 42% in men), whereas specificity was similar in both sexes. The positive predictive value was lower in women (66%) compared with men (84%). Conclusions In clinical practice, test verification bias results in a lower observed specificity and a higher sensitivity of exercise echocardiography. In women, positive predictive value and adjusted sensitivity are lower compared with that in men.
Mechanical Pressure and Stretch Release Endothelin-1 From Human Atherosclerotic Coronary Arteries In Vivo
Hasdai, David, Holmes, David R. , Garratt, Kirk N. , Edwards, William D. , Lerman, Amir

Mayo Clinic

Circulation | June 12, 2012 | Volume: 95 | Issue: 2 | Pages: 357-362

10.1161/01.cir.95.2.357 | PMID 9008449 Get It

Background Endothelin-1 (ET-1) is an endothelium-derived vasoactive peptide with mitogenic properties. In vitro, vascular release of ET-1 is increased in response to mechanical stress. The goal of the present study was to examine whether ET-1 is released from human atherosclerotic coronary arteries in vivo in response to mechanical pressure and stretch and to characterize immunoreactivity for ET-1 and its precursor, big ET-1, within the atheromatous plaque. Methods and Results Circulating ET-1 levels were measured in 20 patients before and after coronary angioplasty for stable angina at three sampling sites: the femoral artery and the coronary artery segments proximal and distal to the lesion dilated. In addition, atheromatous tissue obtained from 20 patients undergoing directional coronary atherectomy for stable angina were analyzed for immunoreactivity for ET-1 and big ET-1. In patients undergoing angioplasty, ET-1 levels in the distal coronary artery increased after balloon dilatation (8.4±0.9 to 16.4±2 pg/mL, P <.05); proximal coronary artery and systemic ET-1 levels were unchanged. The degree of mechanical stress applied (product of duration and pressure of balloon inflation) correlated with the change in distal coronary artery ET-1 levels ( r =.71, P <.01). Immunoreactivity for big ET-1 and ET-1 was ubiquitous in the extracellular space and the intracellular compartment (macrophages, myointimal cells, myofibroblasts, and endothelial cells) of human coronary atheromatous tissue. Conclusions Big ET-1 and ET-1 immunoreactivity is ubiquitous within the intracellular and extracellular compartments of coronary atherosclerotic tissue. ET-1 is released from these sites in response to mechanical stress. These findings support a role for endothelins in the evolution and progression of coronary atherosclerosis in humans.
Clinical Reality of Lowering Total and LDL Cholesterol
Frye, Robert L.

Mayo Clinic

Circulation | June 12, 2012 | Volume: 95 | Issue: 2 | Pages: 306-307

10.1161/01.cir.95.2.306 | PMID 9008438 Get It

Relation of Operator Volume and Experience to Procedural Outcome of Percutaneous Coronary Revascularization at Hospitals With High Interventional Volumes
Ellis, Stephen G. , Holmes, David R. , Shaw, Richard E. , Block, Peter C. , King, Spencer B., Weintraub, William S.

Mayo Clinic

Circulation | June 12, 2012 | Volume: 95 | Issue: 11 | Pages: 2479-2484

10.1161/01.cir.95.11.2479 | PMID 9184577 Get It

Background Although an inverse relation between physician caseload and complications has been conclusively demonstrated for several surgical procedures, such data are lacking for percutaneous coronary intervention, and the ACC/AHA guidelines requiring ≥75 cases per year for operator “competency” are considered by some physicians to be arbitrary. Methods and Results From quality-controlled databases at five high-volume centers, models predictive of death and the composite outcome of death, Q-wave infarction, or emergency bypass surgery were developed from 12 985 consecutively treated patients during 1993 through 1994. Models had moderate to high discriminative capacity (area under ROC curves, 0.65 to 0.85), were well calibrated, and were not overfitted by standard tests. These models were used for risk adjustment, and the relations between both yearly caseload and years of interventional experience and the two adverse outcome measures were explored for all 38 physicians with ≥30 cases per year. The average physician performed a mean±SD of 163±24 cases per year and had been practicing angioplasty for 8±5 years. Risk-adjusted measures of both death and the composite adverse outcome were inversely related to the number of cases each operator performed annually but bore no relation to total years of experience. Both adverse outcomes were more closely related to the logarithm of caseload (for death, r =.37, P =.01; for death, Q-wave infarction, or bypass surgery, r =.58, P <.001) than to linear caseload. Conclusions In this analysis, high-volume operators had a lower incidence of major complications than did lower-volume operators, but the difference was not consistent for all operators. If these data are validated, their implications for hospital, physician, and payer policy will require exploration.
Aortic Valve Replacement for Aortic Stenosis With Severe Left Ventricular Dysfunction
Connolly, Heidi M. , Oh, Jae K. , Orszulak, Thomas A., Osborn, Sara L., Roger, Véronique L. , Hodge, David O. , Bailey, Kent R. , Seward, James B., Tajik, A. Jamil

Mayo Clinic

Circulation | June 12, 2012 | Volume: 95 | Issue: 10 | Pages: 2395-2400

10.1161/01.cir.95.10.2395 | PMID 9170402 Get It

BackgroundAortic valve replacement for aortic stenosis (AS) carries an increased risk in the presence of left ventricular (LV) systolic dysfunction. Few data are available on the outcome of such patients.Methods and ResultsBetween 1985 and 1992, 154 consecutive patients (107 men and 47 women) with LV systolic dysfunction (ejection fraction [EF] ≤35%) underwent aortic valve replacement for AS. The mean preoperative characteristics included EF, 27±6%; aortic valve mean gradient, 44±18 mm Hg; aortic valve area, 0.6±0.2 cm2; and cardiac output, 4.1±1.5 L/min. Simultaneous coronary artery bypass graft surgery was performed in 78 patients (51%). Perioperative (30-day) mortality was 9% (14 of 154 patients). Fifty patients died during follow-up. Coronary artery disease (P=.002) and a reduced preoperative cardiac output (P=.03) were significantly related to reduced overall survival rate by multivariate analysis. Postoperative improvement occurred in most patients; 88% were New York Heart Association class III or IV before surgery versus 7% after surgery. Postoperative EF was assessed in 76% of survivors; 76% of these demonstrated improvement. By multivariate analysis, change in EF was inversely related to coronary disease (P=.002) and preoperative aortic valve area (P=.03).ConclusionsDespite LV dysfunction, the risk of aortic valve replacement for AS was acceptable and related to coronary artery disease and mean aortic gradient, and long-term survival was related to coronary disease and cardiac output. Improvement in symptoms and EF occurred in most patients.
Marked Inflammatory Sequelae to Implantation of Biodegradable and Nonbiodegradable Polymers in Porcine Coronary Arteries
Giessen, Willem J. van der, Schwartz, Robert S., Beusekom, Heleen M.M. van , Holmes, David R. , Ellis, Stephen G. , Lincoff, A. Michael , Serruys, Patrick W. , Topol, Eric J.

Mayo Clinic

Circulation | June 12, 2012 | Volume: 94 | Issue: 7 | Pages: 1690-1697

10.1161/01.cir.94.7.1690 | PMID 8840862 Get It

Background With the thrombogenic tendency and permanent implant nature of metallic stents, synthetic polymers have been proposed as candidate materials for stents and local drug delivery designs. We investigated the biocompatibility of several synthetic polymers after experimental placement in the coronary artery. Methods and Results Five different biodegradable polymers (polyglycolic acid/polylactic acid [PGLA], polycaprolactone [PCL], polyhydroxybutyrate valerate [PHBV], polyorthoester [POE], and polyethyleneoxide/polybutylene terephthalate [PEO/PBTP]) and three nonbiodegradable polymers (polyurethane [PUR], silicone [SIL], and polyethylene terephthalate [PETP]) were tested as strips deployed longitudinally across 90° of the circumferential surface of coil wire stents. Appropriately sized polymer-loaded stents were implanted in porcine coronary arteries of 2.5- to 3.0-mm diameter. Four weeks after implantation, stent patency was assessed by angiography followed by microscopic examination of the coronary arteries. The biodegradable PCL, PHBV, and POE and the nonbiodegradable PUR and SIL evoked extensive inflammatory responses and fibrocellular proliferation (thickness of tissue response: 0.79±0.22, 1.12±0.01, 2.36±0.60, 1.24±0.36, and 1.43±0.15 mm, respectively). Less but still severe responses were observed for the biodegradable PGLA and PEO/PBTP (0.46±0.18 and 0.61±0.23 mm, respectively) and for the nonbiodegradable PETP (0.46±0.11 mm). Conclusions An array of both biodegradable and nonbiodegradable polymers has been demonstrated to induce a marked inflammatory reaction within the coronary artery with subsequent neointimal thickening, which was not expected on the basis of in vitro tests. The observed tissue response may be attributable to a combination of parent polymer compound, biodegradation products, and possibly implant geometry.
Diagnosis of Sinus Venosus Atrial Septal Defect With Transesophageal Echocardiography
Pascoe, R., Oh, Jae K. , Warnes, Carole A. , Danielson, Gordon K., Seward, James B., Tajik, A. Jamil

Mayo Clinic

Circulation | June 12, 2012 | Volume: 94 | Issue: 5 | Pages: 1049-1055

10.1161/01.cir.94.5.1049 | PMID 8790045 Get It

BackgroundSinus venosus atrial septal defect (SVD) is underdiagnosed with transthoracic echocardiography because of its posterior (far field) location. Transesophageal echocardiography (TEE) should be ideally suited to diagnose SVD, given the proximity of the transducer to the defect.Methods and ResultsA retrospective study was undertaken that used the medical history, echocardiographic findings, and surgical data of patients identified from computer records as having the diagnosis of SVD during the period in which TEE has been in use (1987 to 1995). Twenty-five patients (14 females and 11 males; median age, 45 years; range, 10 to 75 years) with SVD had TEE between 1987 and 1995. Prior transthoracic echocardiography clearly defined the SVD in 3 of these patients, and it was suspected in another 11 on the basis of color-flow imaging. Ten patients had unexplained dilatation of the right side of the heart, which prompted TEE examination. SVD was visualized with TEE in all 25 patients and ranged in size from 1 to 3 cm. Thirty-seven right-sided anomalous pulmonary venous connections were identified in 23 patients. No left-sided anomalous pulmonary venous connections were detected. Anatomic confirmation was obtained in all 23 surgical patients. No patient required preoperative cardiac catheterization for diagnosis.ConclusionsTEE is accurate for the diagnosis of SVD and should be undertaken in any patient with unexplained dilatation of the right side of the heart. The associated pulmonary venous abnormalities can be identified with TEE. Cardiac catheterization for diagnostic purposes should not be required before surgical correction.
Extent of Clinical Improvement After Surgical Treatment of Hypertrophic Obstructive Cardiomyopathy
McCully, Robert B. , Tajik, A. Jamil , Danielson, Gordon K., Nishimura, Rick A. , Schaff, Hartzell V.

Mayo Clinic

Circulation | June 12, 2012 | Volume: 94 | Issue: 3 | Pages: 467-471

10.1161/01.cir.94.3.467 | PMID 8759090 Get It

BackgroundA subgroup of patients with hypertrophic obstructive cardiomyopathy remain severely symptomatic despite optimal medical therapy. Septal myectomy reduces or eliminates left ventricular outflow obstruction and produces marked symptomatic improvement. With the recent advent of alternative methods for treatment of this disorder, such as dual-chamber pacing, it is necessary to establish the risks and benefits of septal myectomy in the modern surgical era.Methods and ResultsThe clinical, ECG, echocardiographic, cardiac catheterization, and surgical data were analyzed for 65 patients 20 to 70 years old with hypertrophic obstructive cardiomyopathy who had surgical treatment between 1986 and 1992. Specific symptoms and overall functional status were evaluated before surgery and at the end of the first postoperative year. Subsequent long-term clinical postoperative follow-up was also obtained. The extent of postoperative improvement was measured by the presence and severity of persistent symptoms, overall New York Heart Association (NYHA) functional class, and patients' self-perceptions of overall improvement. Of the patients, 95% were in NYHA functional class III or IV before surgery: 95% had dyspnea, 62% had angina, 63% had near-syncope, and 23% had syncope. The overall early mortality rate was 4.6%; there was no mortality among the 45 patients who underwent isolated septal myectomy. At the 1-year postoperative evaluation, 89% of survivors were in NYHA functional class I or II, and 47% believed that they had 100% improvement. Significant improvement (as defined) was seen in 67% of patients with dyspnea, 90% with angina, 86% with near-syncope, and 100% with syncope. The 5-year survival rate was 92%.ConclusionsThe results of the present study reaffirm the efficacy of surgical treatment of hypertrophic obstructive cardiomyopathy in patients who are severely symptomatic despite optimal medical therapy and serve as a useful reference by which the surgical approach can be compared with new and potentially promising treatment alternatives.
Secular Trends in Cardiac Transplant Recipient and Donor Management in the United States, 1990 to 1994
Rodeheffer, Richard J. , Naftel, David C., Stevenson, Lynne W. , Porter, Charles , Miller, Leslie W., Kenzora, Joseph L., Haas, Garrie J. , Bourge, Robert C. , Mehra, Mandeep R. , Young, James B. , Kirklin, James K. , Mehra, Mandeep R

Mayo Clinic

Circulation | June 12, 2012 | Volume: 94 | Issue: 11 | Pages: 2883-2889

10.1161/01.cir.94.11.2883 | PMID 8941117 Get It

Background The growth of the US cardiac transplant waiting list has outpaced the increase in donors, resulting in a widening gap between the number of waiting recipients and available donors. These trends have generated concern that longer waiting times may result in more patients deteriorating to urgent status and that transplanting only patients who are in an advanced state of decompensation will reduce posttransplant survival. Furthermore, the shortage of donors may result in extending the guidelines for donor acceptability to a degree that increases graft failure and posttransplant mortality. We measured these secular trends in the Cardiac Transplant Research Database to provide current data on time-dependent changes in US cardiac transplant practice and survival. Methods and Results At the time of this analysis, the Cardiac Transplant Research Database included all 2749 patients transplanted from January 1, 1990, to June 30, 1994, in the 25 participating transplant centers. During this 4.5-year period, the median waiting time for recipients who received a transplant increased from 2.7 to 3.5 months ( P <.0001), and the proportion of recipients whose status was urgent at transplantation increased from 41% to 60% ( P <.0001). Donor ischemic time increased from 150 to 166 minutes ( P <.0001), and the proportion of donors requiring pressor support increased from 68% to 85% ( P <.0001). Despite these changes in practice, the 1-year survival rate remained constant at 84% during this 4.5-year interval. There was no significant difference in 1-year survival rate between urgent status patients (83%) and nonurgent status patients (85%) ( P =.08). Conclusions The widening gap between the number of waiting recipients and the number of donors has resulted in a continuing trend toward transplanting urgent status recipients and to a liberalization of donor acceptance criteria. Despite these changes, posttransplant survival has remained constant.
Surgery for Aortic Regurgitation in Women
Klodas, Elizabeth , Tajik, A. Jamil , Mullany, Charles J., Bailey, Kent R. , Seward, James B., Enriquez‐Sarano, Maurice , Enriquez-Sarano, Maurice

Mayo Clinic

Circulation | June 12, 2012 | Volume: 94 | Issue: 10 | Pages: 2472-2478

10.1161/01.cir.94.10.2472 | PMID 8921790 Get It

BackgroundIndications for surgical correction of aortic regurgitation have been established mostly in men and have not been validated in women. The outcome of this surgical correction in women is unknown.Methods and ResultsBaseline characteristics and postoperative outcomes were compared between 51 women and 198 men undergoing surgery for isolated aortic regurgitation between 1980 and 1989. Compared with men, women had surgery rarely for severe left ventricular enlargement (systolic diameter ≥55 mm in 11% versus 27%,P=.031; diastolic diameter ≥80 mm in 0% versus 16%,P<.0001) and more often for class III to IV symptoms (59% versus 32%,P<.0001). Operative mortalities were similar in women and men (3.9% and 4.5%, respectively). Among operative survivors, 10-year survival was worse for women than for men (39±9% versus 72±4%,P=.0002) and, in contrast with men, was worse than expected for women (P<.0001). Independent predictors of late survival were different for men (age and ejection fraction) and women (age and concomitant coronary bypass grafting). By multivariate analysis, female sex was an independent predictor of worse late survival (adjusted relative risk, 1.80; 95% CI, 1.04 to 3.11).ConclusionsThe generalization to women of the unadjusted left ventricular diameter surgical criteria established in men results in irrelevant criteria almost never reached in women, who often undergo surgery after developing severe symptoms. After surgery, women exhibit an excess late mortality, suggesting that surgical correction of aortic regurgitation should be considered at an earlier stage in women.