Citations

Showing 10 of 107906 citations.

Intraperitoneal metastasis of gastric cancer: new insights on resident macrophages
Yu, Xianzhe , Zhu, Ling‐Ling , Zhu, Lingling, Wang, Leibo

Mayo Clinic

International Journal of Surgery | November 14, 2025 | Volume: 112 | Issue: 2 | Pages: 4547-4562

10.1097/js9.0000000000003944 | PMID 41233166 Get It

Peritoneal metastasis (PM) is a common and lethal complication of gastric cancer (GC), occurring in approximately 50% of patients with advanced disease. It is characterized by a highly immunosuppressive microenvironment and limited response to current systemic therapies, resulting in a median survival of only 3–6 months. The objective of this review was to explore the critical role of resident macrophages within the peritoneal immune microenvironment in the development and progression of GC PM and to discuss their potential as therapeutic targets. Peritoneal resident macrophages (PRMs), particularly the GATA6⁺ large peritoneal macrophages (LPMs), are hijacked by GC cells through metabolic reprogramming, transcriptional regulation, and paracrine signaling. These macrophages adopt a protumor M2-like phenotype, promote immunosuppression through T-cell exclusion and Treg recruitment, facilitate cancer cell adhesion and spheroid formation, and contribute to chemotherapy resistance. Emerging therapeutic strategies, including cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (HIPEC), nanoparticle-mediated macrophage repolarization, CSF-1 R/CCR2 axis inhibition, and chimeric antigen receptor macrophages (CAR-M), show promise in targeting these cells to restore antitumor immunity. In conclusion, resident macrophages are pivotal in shaping the immunosuppressive landscape of GC PM. Targeting these cells represents a promising avenue for novel combination therapies aimed at improving outcomes for patients with GC PM.
Rethinking SLIL classifications in the age of needle arthroscopy: do we need sub-grades?
Reiser, Daniel , Kakar, Sanjeev , Reiser, Daniel , Reiser, Daniel

Mayo Clinic

Bone & Joint Open | November 14, 2025 | Volume: 6 | Issue: 11 | Pages: 1466-1467

10.1302/2633-1462.611.bjo-2025-0265.r1 | PMID 41232567 Get It

How to Interpret a Nerve Conduction Study
Zelikovich, Aaron S. , Pucci, Gabriela Figueiredo , Minkis, Jonathan, Pinto, Marcus Vinícius , Pinto, Marcus V , Pucci, Gabriela F

Mayo Clinic

Neurology Education | November 13, 2025 | Volume: 4 | Issue: 4 | Pages: No page available

10.1212/ne9.0000000000200275 | PMID 41244751 Get It

One-Year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication With a Subcutaneous Implantable Cardioverter Defibrillator
Lloyd, Michael S. , Roberts, Paul R. , Doshi, Rahul N. , Wright, David J. , Boersma, Lucas V.A. , Friedman, Paul A. , Neužil, Petr , Blomström‐Lundqvist, Carina , Bongiorni, M. G. , Burke, Martin C. , Gras, Daniel , Kutalek, Steven , Marijon, Éloi , Amin, Anish K. , Aasbo, Johan D. , West, Julie, Matznick, Elizabeth , Speakman, Benjamin, Bachman, Tara N. , Reddy, Vivek Y , Roberts, Paul , Doshi, Rahul N , Wright, David L , Boersma, Lucas , Friedman, Paul A , Neuzil, Petr , Blomström-Lundqvist, Carina , Bongiorni, Maria Grazia , Burke, Martin C , Gras, Daniel , Kutalek, Steven P , Marijon, Eloi , Tolosana, Jose María , Amin, Anish K , Epstein, Laurence M , Aasbo, Johan D , Callahan, Thomas D , Brisben, Amy J , Matznick, Elizabeth , Bachman, Tara N , Mont, Lluís , Knops, Reinoud Elwin , Reddy, Vivek Y. , Epstein, Laurence M.

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | November 13, 2025 | Volume: 19 | Issue: 1 | Pages: No page available

10.1161/circep.125.014395 | PMID 41231774 Get It

BACKGROUND: MODULAR antitachycardia pacing (ATP), a multicenter, international trial, assesses a modular cardiac rhythm management system: a subcutaneous implantable cardioverter defibrillator in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular tachycardia. METHODS: Enrolees had one or more clinical risk factors for ventricular tachycardia and did not require chronic pacing. Complications included prespecified major LP system- and procedure-related complications, and any complication related to the LP, subcutaneous implantable cardioverter defibrillator, implantation, or study protocol. Survival analysis was performed to identify complication-free rates, therapy delivery, and all-cause mortality. RESULTS: The 297 patients enrolled had an ejection fraction of 35±13%, 43% secondary prevention indications, and 59% with prior ventricular arrhythmias. Of 286 patients undergoing LP implantation (100% success), 251 patients completed 12-month follow-up. Mortality rate was 6%, with none related to the implant procedure. Median follow-up duration was 23.4 months (interquartile range, 17.9–28.1). The LP major complication-free rate was 97.2%, exceeding the performance goal. The overall LP+ subcutaneous implantable cardioverter defibrillator system-related complication-free rate was 88.5%. Appropriate tachyarrhythmia-therapy (ATP+shock) rates were 14.4%, and appropriate shock rates were 8.5%. Inappropriate total tachyarrhythmia therapy was 9.5% of which 8.5% were shocks. ATP was 67.3% successful in terminating ventricular arrhythmia episodes and accelerated ventricular arrhythmias in 10.1% of episodes. Overall therapy burden (ATP+shock) was 96/100 patient-years, of which 44/100 patient-years was for shock delivery. CONCLUSIONS: One-year outcomes of the first modular pacing-defibrillator system reveal low system and LP complication rates and good ATP efficacy rates, suggesting that the modular cardiac rhythm management is a viable alternative to single-chamber implantable cardioverter defibrillators using low-energy pacing capability without the need for transvenous leads. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/ ; Unique identifier: NCT04798768.
Winning at the Radiology Podium: First-timer’s Guide to Crafting and Delivering a Memorable Conference Presentation
Raichandani, Surbhi , Ansari, Shehbaz , Sorin, Vera , Ozcan, B. Bersu , Rouzrokh, Pouria , Rouzrokh, Pouria

Mayo Clinic

RadioGraphics | November 13, 2025 | Volume: 45 | Issue: 12 | Pages: No page available

10.1148/rg.250003 | PMID 41231714 Get It

Imaging in Renovascular Hypertension: State of the Art
Gonzalez, Tomas V. , Bookwalter, Candice A., Khandelwal, Ashish , François, Christopher J. , Takahashi, Edwin A. , Bookwalter, Candice, Rajiah, Prabhakar , François, Christopher , Takahashi, Edwin A , Khandelwal, Ashish , Rajiah, Prabhakar

Mayo Clinic

RadioGraphics | November 13, 2025 | Volume: 45 | Issue: 12 | Pages: No page available

10.1148/rg.240211 | PMID 41231712 Get It

Renovascular hypertension is the most common cause of secondary hypertension, and radiologist awareness of the various imaging appearances and various causes is crucial for accurate diagnosis and guiding treatment.
Transformable Renal Cancer Targeted Responsive Nanopeptide Probes Effectively Inhibit Renal Cancer Progression and Metastasis by Inhibiting Renal Blood Vessels and Cancer Cells
Kong, Bin , Wu, Xiu‐Hai, Li, Cong , Chen, Meiqun, Liu, Yuwen , Liu, Cunyao, Wang, Xinyue , Chen, Bogong, Zang, Jiahui, Jian, Lingrui, Shen, Jiachen , Yu, Jiaao, Wu, Qiang , Yang, Guang , Wang, Ziqi , Wang, Lu , Wang, Lu , Liu, Pan , Chen, Meiqun, Liu, Cunyao, Liu, Ming

Mayo Clinic

ACS Applied Materials & Interfaces | November 13, 2025 | Volume: 17 | Issue: 47 | Pages: 64232-64243

10.1021/acsami.5c16546 | PMID 41231680 Get It

Measurement of microdosimetric spectra of high‐LET particle beams using the ENCORE detector
Hartzell, Shannon , López-Saavedra, E. , Wiedenhöver, I. , Beltran, Chris , Beltran, Chris J , Furutani, Keith M. , Almaraz-Calderon, Sergio J , Baby, L. T.

Mayo Clinic

Medical Physics | November 13, 2025 | Volume: 52 | Issue: 11 | Pages: No page available

10.1002/mp.70150 | PMID 41231684 Get It

Abstract Background Heavy ion radiotherapy offers distinct advantages over conventional treatments due to its superior dose distribution and enhanced biological effectiveness. However, the microdosimetric characteristics of high linear energy transfer (LET) ions, particularly near the Bragg peak, remain poorly characterized. Most experimental microdosimetry has been conducted at lower LETs, leaving a critical gap in high‐LET microdosimetric data. Purpose This study aims to extend microdosimetry to several different high‐LET ions (700–2500 keV/µm) using the novel ENCORE detector. Methods Microdosimetry was performed at the Florida State University John D. Fox Accelerator Laboratory using the ENCORE detector, a multi‐sampling ionization chamber filled with low‐pressure tissue‐equivalent gas capable of resolving energy deposition from approximately 200 keV to 3 MeV. 12 C, 16 O, and 28 Si beams were accelerated to 17–55 MeV and delivered to the segmented detector. Energy deposition patterns near the Bragg peak were recorded, and microdosimetric spectra were reconstructed. Monte Carlo was used to model the experimental setup. From each measured and simulated spectra, dose‐mean lineal energy () was calculated and compared. Results The 16 strips of the ENCORE corresponded to a tissue‐equivalent thickness of 17.6 µm, enabling resolution of energy deposition immediately proximal and distal to the Bragg peak. In six measurement configurations, the ion beam stopped within this range, allowing precise mapping of the profile around the peak; in the remaining configurations, the beam fully traversed the detector. Across all beams, difference between measured and simulated averaged 12%, based on one measurement per strip. Peak measured reached 920 ± 220, 1240 ± 206, and 2460 ± 620 keV/µm for 12 C, 16 O, and 28 Si beams, respectively. Conclusion This study demonstrated that ENCORE can resolve microdosimetric spectra with high spatial and LET resolution across a range of ion energies. Measured values reasonably agreed with Monte Carlo simulations, validating the potential of ENCORE for position‐resolved microdosimetry and model benchmarking in particle therapy.
Method Validation of Dipeptidyl Peptidase 3 Assay
Donato, Leslie J. , Meeusen, Jeffrey W. , Scott, Renee’ J, Vasile, Vlad C. , Jaffe, Allan S. , Donato, Leslie , Scott, Renee’ J, Jaffe, Allan S.

Mayo Clinic

The Journal of Applied Laboratory Medicine | November 13, 2025 | Volume: 11 | Issue: 2 | Pages: 350-356

10.1093/jalm/jfaf173 | PMID 41231409 Get It

Abstract Background Dipeptidyl peptidase 3 (DPP3) is a peptidase released from dying cells. It cleaves proteins in the renin–angiotensin pathway, which can result in hemodynamic instability. At elevated concentrations DPP3 is associated with worse outcomes, particularly in patients with shock. Herein we describe the assay performance of a DPP3 assay (4TEEN4 Pharmaceuticals GmbH) in human plasma. Methods DPP3 concentration was measured using the DPP3 immunoluminometric assay (4TEEN4 Pharmaceuticals GmbH) and the signal was read using a luminometer (Berthold Centro LB963). Analytical performance was established for precision, linearity, accuracy, detection limit, analytical specificity, reference interval, kit lot-to-lot comparison, specimen type, and sample stability. Results Limit of detection was verified at 1.6 ng/mL in EDTA plasma with a coefficient of variation (CV) of <10%. Precision studies revealed a CV ≤ 6% at 28.5 ng/mL and 59.4 ng/mL and comparability with a manufacturer performed assay was demonstrated between 7.7 and 195.2 ng/mL. An upper 97.5% limit of 22 ng/mL without age or sex associations was verified in healthy donors. The assay was not susceptible to interference from lipemia or bilirubin. However, measured DPP3 concentrations increased linearly with increasing hemolysis. DPP3 concentrations are stable in EDTA plasma for up to 24 h and at least 11 months when stored ambient or at −80°C, respectively. Conclusions DPP3 can be measured precisely in EDTA plasma using the immunoluminometric DPP3 assay. Given the potential clinical use of DPP3 in critical care patients, caution should be taken to avoid inducing pre-analytical hemolysis during sample collection.