Technical Note: kV‐independent coronary calcium scoring: A phantom evaluation of score accuracy and potential radiation dose reduction
Tao, Shengzhen , Sheedy, Emily N., Bruesewitz, Michael R. , Weber, Nikkole M. , Williams, Kyle , Halaweish, Ahmed F., Schmidt, Bernhard , Williamson, Eric E. , McCollough, C, Sheedy, Emily, Bruesewitz, Michael, Weber, Nikkole, McCollough, Cynthia, Leng, Shuai

Mayo Clinic

Medical Physics | December 18, 2020 | Volume: 48 | Issue: 3 | Pages: 1307-1314

10.1002/mp.14663 | PMID 33332626 Get It

Purpose To determine the accuracy of CT number and calcium score of a kV‐independent technique based on an artificial 120 kV reconstruction, and its potential to reduce radiation dose. Methods Anthropomorphic chest phantoms were scanned on a third‐generation dual‐source CT system equipped with the artificial 120 kV reconstruction. First, a phantom module containing a 20‐mm diameter hydroxyapatite (HA) insert was scanned inside the chest phantoms at different tube potentials (70–140 kV) to evaluate calcium CT number accuracy. Next, three small HA inserts (diameter/length = 5 mm) were inserted into a pork steak and scanned inside the phantoms to evaluate calcium score accuracy at different kVs. Finally, the same setup was scanned using automatic exposure control (AEC) at 120 kV, and then with automatic kV selection (auto‐kV). Phantoms were also scanned at 120 kV using a size‐dependent mA chart. CT numbers of soft tissue and calcium were measured from different kV images. Calcium score of each small HA insert was measured using commercial software. Results The CT number difference from 120 kV was small with tube potentials from 90 to 140 kV for both soft tissue and calcium (maximal difference of 4/5 HU, respectively). Consistent calcium scores were obtained from images of different kVs compared to 120 kV, with a relative difference <8%. Auto‐kV provided a 25–34% dose reduction compared to AEC alone. Conclusion A kV‐independent calcium scoring technique can produce artificial 120 kV images with consistent soft tissue and calcium CT numbers compared to standard 120 kV examinations. When coupled with auto‐kV, this technique can reduce radiation by 25–34% compared to that with AEC alone, while providing consistent calcium scores as that of standard 120 kV examinations.
Low‐dose CT image and projection dataset
Moen, Taylor R., Chen, Baiyu , Holmes, David R. , Yu, Zhicong , Yu, Lifeng , Duan, Xinhui , Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Mayo Clinic

Medical Physics | November 17, 2020 | Volume: 48 | Issue: 2 | Pages: 902-911

10.1002/mp.14594 | PMID 33202055 Get It

Purpose To describe a large, publicly available dataset comprising computed tomography (CT) projection data from patient exams, both at routine clinical doses and simulated lower doses. Acquisition and Validation Methods The library was developed under local ethics committee approval. Projection and image data from 299 clinically performed patient CT exams were archived for three types of clinical exams: noncontrast head CT scans acquired for acute cognitive or motor deficit, low‐dose noncontrast chest scans acquired to screen high‐risk patients for pulmonary nodules, and contrast‐enhanced CT scans of the abdomen acquired to look for metastatic liver lesions. Scans were performed on CT systems from two different CT manufacturers using routine clinical protocols. Projection data were validated by reconstructing the data using several different reconstruction algorithms and through use of the data in the 2016 Low Dose CT Grand Challenge. Reduced dose projection data were simulated for each scan using a validated noise‐insertion method. Radiologists marked location and diagnosis for detected pathologies. Reference truth was obtained from the patient medical record, either from histology or subsequent imaging. Data Format and Usage Notes Projection datasets were converted into the previously developed DICOM‐CT‐PD format, which is an extended DICOM format created to store CT projections and acquisition geometry in a nonproprietary format. Image data are stored in the standard DICOM image format and clinical data in a spreadsheet. Materials are provided to help investigators use the DICOM‐CT‐PD files, including a dictionary file, data reader, and user manual. The library is publicly available from The Cancer Imaging Archive ( https://doi.org/10.7937/9npb‐2637 ). Potential Applications This CT data library will facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence. The provided clinical information allows evaluation of task‐based diagnostic performance.
Deep‐learning‐based direct inversion for material decomposition
Gong, Hao , Tao, Shengzhen , Rajendran, Kishore , Zhou, Wei , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Medical Physics | October 6, 2020 | Volume: 47 | Issue: 12 | Pages: 6294-6309

10.1002/mp.14523 | PMID 33020942 Get It

PurposeTo develop a convolutional neural network (CNN) that can directly estimate material density distribution from multi‐energy computed tomography (CT) images without performing conventional material decomposition.MethodsThe proposed CNN (denoted as Incept‐net) followed the general framework of encoder–decoder network, with an assumption that local image information was sufficient for modeling the nonlinear physical process of multi‐energy CT. Incept‐net was implemented with a customized loss function, including an in‐house‐designed image‐gradient‐correlation (IGC) regularizer to improve edge preservation. The network consisted of two types of customized multibranch modules exploiting multiscale feature representation to improve the robustness over local image noise and artifacts. Inserts with various densities of different materials [hydroxyapatite (HA), iodine, a blood–iodine mixture, and fat] were scanned using a research photon‐counting detector (PCD) CT with two energy thresholds and multiple radiation dose levels. The network was trained using phantom image patches only, and tested with different‐configurations of full field‐of‐view phantom and in vivo porcine images. Furthermore, the nominal mass densities of insert materials were used as the labels in CNN training, which potentially provided an implicit mass conservation constraint. The Incept‐net performance was evaluated in terms of image noise, detail preservation, and quantitative accuracy. Its performance was also compared to common material decomposition algorithms including least‐square‐based material decomposition (LS‐MD), total‐variation regularized material decomposition (TV‐MD), and U‐net‐based method.ResultsIncept‐net improved accuracy of the predicted mass density of basis materials compared with the U‐net, TV‐MD, and LS‐MD: the mean absolute error (MAE) of iodine was 0.66, 1.0, 1.33, and 1.57 mgI/cc for Incept‐net, U‐net, TV‐MD, and LS‐MD, respectively, across all iodine‐present inserts (2.0–24.0 mgI/cc). With the LS‐MD as the baseline, Incept‐net and U‐net achieved comparable noise reduction (both around 95%), both higher than TV‐MD (85%). The proposed IGC regularizer effectively helped both Incept‐net and U‐net to reduce image artifact. Incept‐net closely conserved the total mass densities (i.e., mass conservation constraint) in porcine images, which heuristically validated the quantitative accuracy of its outputs in anatomical background. In general, Incept‐net performance was less dependent on radiation dose levels than the two conventional methods; with approximately 40% less parameters, the Incept‐net achieved relatively improved performance than the comparator U‐net, indicating that performance gain by Incept‐net was not achieved by simply increasing network learning capacity.ConclusionIncept‐net demonstrated superior qualitative image appearance, quantitative accuracy, and lower noise than the conventional methods and less sensitive to dose change. Incept‐net generalized and performed well with unseen image structures and different material mass densities. This study provided preliminary evidence that the proposed CNN may be used to improve the material decomposition quality in multi‐energy CT.
Overcoming calcium blooming and improving the quantification accuracy of percent area luminal stenosis by material decomposition of multi-energy computed tomography datasets
Li, Zhoubo , Halaweish, Ahmed F., Yu, Zhicong , Yu, Lifeng , Ritman, Erik L., Leng, Shuai , Halaweish, Ahmed F , Yu, Lifeng , McCollough, Cynthia H , Leng, Shuai , McCollough, Cynthia H.

Mayo Clinic

Journal of Medical Imaging | October 1, 2020 | Volume: 7 | Issue: 05 | Pages: No page available

10.1117/1.jmi.7.5.053501 | PMID 33033732 Get It

Use of artificial intelligence in computed tomography dose optimisation
McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Annals of the ICRP | September 1, 2020 | Volume: 49 | Issue: 1_suppl | Pages: 113-125

10.1177/0146645320940827 | PMID 32870019 Get It

The field of artificial intelligence (AI) is transforming almost every aspect of modern society, including medical imaging. In computed tomography (CT), AI holds the promise of enabling further reductions in patient radiation dose through automation and optimisation of data acquisition processes, including patient positioning and acquisition parameter settings. Subsequent to data collection, optimisation of image reconstruction parameters, advanced reconstruction algorithms, and image denoising methods improve several aspects of image quality, especially in reducing image noise and enabling the use of lower radiation doses for data acquisition. Finally, AI-based methods to automatically segment organs or detect and characterise pathology have been translated out of the research environment and into clinical practice to bring automation, increased sensitivity, and new clinical applications to patient care, ultimately increasing the benefit to the patient from medically justified CT examinations. In summary, since the introduction of CT, a large number of technical advances have enabled increased clinical benefit and decreased patient risk, not only by reducing radiation dose, but also by reducing the likelihood of errors in the performance and interpretation of medically justified CT examinations.
Update on Multienergy CT: Physics, Principles, and Applications
Rajiah, Prabhakar , Parakh, Anushri , Kay, Fernando Uliana , Kambadakone, Avinash , Leng, Shuai , Kay, Fernando , Baruah, Dhiraj, Kambadakone, Avinash R , Leng, Shuai , Rajiah, Prabhakar , Baruah, Dhiraj

Mayo Clinic

RadioGraphics | August 21, 2020 | Volume: 40 | Issue: 5 | Pages: 1284-1308

10.1148/rg.2020200038 | PMID 32822281 Get It

Deep-learning-based model observer for a lung nodule detection task in computed tomography
Gong, Hao , Hu, Qiyuan , Walther, Andrew , Koo, Chi Wan , Levin, David L. , Johnson, Tucker F. , Hora, Megan J., Yu, Lifeng , Takahashi, Edwin A. , Leng, Shuai , McCollough, Cynthia H , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Mayo Clinic

Journal of Medical Imaging | June 30, 2020 | Volume: 7 | Issue: 04 | Pages: 1

10.1117/1.jmi.7.4.042807 | PMID 32647740 Get It

Multi‐energy computed tomography and material quantification: Current barriers and opportunities for advancement
Jacobsen, Megan C. , Thrower, Sara , Court, Laurence E. , Tamm, Eric P. , Cody, Dianna D. , Layman, Rick R. , Thrower, Sara , Ger, Rachel , Leng, Shuai , Brock, Kristy K. , Cressman, Erik N. K.

Mayo Clinic

Medical Physics | May 26, 2020 | Volume: 47 | Issue: 8 | Pages: 3752-3771

10.1002/mp.14241 | PMID 32453879 Get It

Computed tomography (CT) technology has rapidly evolved since its introduction in the 1970s. It is a highly important diagnostic tool for clinicians as demonstrated by the significant increase in utilization over several decades. However, much of the effort to develop and advance CT applications has been focused on improving visual sensitivity and reducing radiation dose. In comparison to these areas, improvements in quantitative CT have lagged behind. While this could be a consequence of the technological limitations of conventional CT, advanced dual‐energy CT (DECT) and photon‐counting detector CT (PCD‐CT) offer new opportunities for quantitation. Routine use of DECT is becoming more widely available and PCD‐CT is rapidly developing. This review covers efforts to address an unmet need for improved quantitative imaging to better characterize disease, identify biomarkers, and evaluate therapeutic response, with an emphasis on multi‐energy CT applications. The review will primarily discuss applications that have utilized quantitative metrics using both conventional and DECT, such as bone mineral density measurement, evaluation of renal lesions, and diagnosis of fatty liver disease. Other topics that will be discussed include efforts to improve quantitative CT volumetry and radiomics. Finally, we will address the use of quantitative CT to enhance image‐guided techniques for surgery, radiotherapy and interventions and provide unique opportunities for development of new contrast agents.
Quantitative Knee Arthrography in a Large Animal Model of Osteoarthritis Using Photon-Counting Detector CT
Murthy, Naveen S. , Frick, Matthew A., Tao, Shengzhen , Unger, Mark, LaVallee, Katherine T, Larson, Nicholas B. , Maus, Timothy P. , Larson, Nicholas B , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Mayo Clinic

Investigative Radiology | January 27, 2020 | Volume: 55 | Issue: 6 | Pages: 349-356

10.1097/rli.0000000000000648 | PMID 31985604 Get It

Objective The aim of this study was to grade cartilage damage in a swine model of osteoarthritis using a whole-body photon-counting detector (PCD) CT. Materials and Methods A multienergy phantom containing gadolinium (Gd) (2, 4, 8, and 16 mg/mL) and hydroxyapatite (200 and 400 mg/cc) was scanned using a PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs, D50 reconstruction kernel) to serve as calibration for material decomposition and to assess quantification accuracy. Osteoarthritis was induced in Yucatan miniswine (n = 8) using 1.2 mg monoiodoacetate (MIA) injected into a randomized knee, whereas the contralateral control knee received saline. Twenty-one days later, a contrast bolus (gadoterate meglumine, 4 mL/knee) was intra-articularly administered into both knees. The knees were simultaneously scanned on the PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs). Multienergy images were reconstructed with a sharp “V71” kernel and a quantitative “D50” kernel. Image denoising was applied to the V71 images before grading cartilage damage, and an iterative material decomposition technique was applied to D50 images to generate the Gd maps. Two radiologists blinded to the knee injection status graded the cartilage integrity based on a modified International Cartilage Repair Society scoring system. Histology was performed on excised cartilage using methylene blue/basic fuchsin. Statistical analysis of grade distribution was performed using an exact test of omnibus symmetry with P < 0.05 considered significant. Results Material decomposed images from the multienergy phantom scan showed delineation and quantification of Gd and hydroxyapatite with a root-mean-squared error of 0.3 mg/mL and 18.4 mg/cc, respectively. In the animal cohort, the radiologists reported chondromalacia in the MIA knees with International Cartilage Repair Society scores ranging from grade 1 (cartilage heterogeneity, n = 4 knees) to grade 3 (up to 100% cartilage loss, n = 4 knees). Grade 1 was characterized by cartilage heterogeneity and increased joint space in the patellofemoral compartment, whereas grade 3 was characterized by cartilage erosion and bone-on-bone articulation in the patellofemoral compartment. All control knees were scored as grade 0 (normal cartilage). Significant difference (P = 0.004) was observed in the grade distribution between the MIA and control knees. Gross examination of the excised knees showed cartilage lesions in the grade 3 MIA knees. The Gd maps from material decomposition showed lower contrast levels in the joint space of the MIA knee compared with the contralateral control knee due to joint effusion. Histology revealed chondrocyte loss in the MIA knee cartilage confirming the chondrotoxic effects of MIA on cartilage matrix. Conclusions We demonstrated a high-resolution and quantitative PCD-CT arthrography technique for grading cartilage damage in a large animal model of osteoarthritis. Photon-counting detector CT offers simultaneous high-resolution and multienergy imaging capabilities that allowed morphological assessment of cartilage loss and quantification of contrast levels in the joint as a marker of joint disease. Cartilage damage in the MIA knees was graded using PCD-CT images, and the image-based findings were further confirmed using histology and gross examination of the excised knees.