Citations

Clear

162 citation(s) found for "Huston, John".

Proceedings From the Ice Hockey Summit III: Action on Concussion
Smith, Aynsley M., Alford, Patrick A., Aubry, Mark, Benson, Brian W., Brooks, Alison, Burke, Charles J., Eaves, Michael, Eickhoff, Chad, Erredge, Kristen, Fraser, Douglas D. , Giza, Christopher C. , Greenwald, Richard M., Hoshizaki, Blaine, Huston, John , Jorgensen, Janelle, Joyner, Michael J. , Leaf, Matthew, Leddy, John J. , Margarucci, Kevin, Munce, Thayne A. , Prideaux, Cara C. , Roberts, William O. , Shen, Francis X. , Soma, David , Tabrum, Mark, Stuart, Michael, Wethe, Jennifer V. , Whitehead, James R., Wiese‐Bjornstal, Diane M. , Dodick, David, Finnoff, Jonathan, Joyner, Michael, Krause, David, Prideaux, Cara, Wethe, Jennifer, Joyner, Michael J , Wethe, Jennifer V , Alford, Patrick W. , Black, Amanda M. , D’Arcy, Ryan C.N. , Dodick, David W. , Farrell, Kyle , Finnoff, Jonathan T. , Krause, David A. , LaVoi, Nicole M. , Margulies, Susan Sheps , Mihalik, Jason P. , Oeur, Anna , Stuart, Michael J.

Mayo Clinic

Clinical Journal of Sport Medicine | December 16, 2019 | Volume: 31 | Issue: 3 | Pages: e150-e160

10.1097/jsm.0000000000000745 | PMID 31842055 Get It

Objectives: The Ice Hockey Summit III provided updated scientific evidence on concussions in hockey to inform these 5 objectives: (1) describe sport related concussion (SRC) epidemiology; (2) classify prevention strategies; (3) define objective, diagnostic tests; (4) identify treatment; and (5) integrate science and clinical care into prioritized action plans and policy. Methods: Our action plan evolved from 40 scientific presentations. The 155 attendees (physicians, athletic trainers, physical therapists, nurses, neuropsychologists, scientists, engineers, coaches, and officials) voted to prioritize these action items in the final Summit session. Results: To (1) establish a national and international hockey database for SRCs at all levels; (2) eliminate body checking in Bantam youth hockey games; (3) expand a behavior modification program (Fair Play) to all youth hockey levels; (4) enforce game ejection penalties for fighting in Junior A and professional hockey leagues; (5) establish objective tests to diagnose concussion at point of care; and (6) mandate baseline testing to improve concussion diagnosis for all age groups. Conclusions: Expedient implementation of the Summit III prioritized action items is necessary to reduce the risk, severity, and consequences of concussion in the sport of ice hockey.
Contemporary and emerging magnetic resonance imaging methods for evaluation of moyamoya disease
Rinaldo, Lorenzo , Brinjikji, Waleed , Huston, John , Klaas, James P. , Lehman, Vance T. , Cogswell, Petrice M. , Lanzino, Giuseppe

Mayo Clinic

Neurosurgical Focus | December 6, 2019 | Volume: 47 | Issue: 6 | Pages: E6

10.3171/2019.9.focus19616 | PMID 31786551 Get It

Numerous recent technological advances offer the potential to substantially enhance the MRI evaluation of moyamoya disease (MMD). These include high-resolution volumetric imaging, high-resolution vessel wall characterization, improved cerebral angiographic and perfusion techniques, high-field imaging, fast scanning methods, and artificial intelligence. This review discusses the current state-of-the-art MRI applications in these realms, emphasizing key imaging findings, clinical utility, and areas that will benefit from further investigation. Although these techniques may apply to imaging of a wide array of neurovascular or other neurological conditions, consideration of their application to MMD is useful given the comprehensive multidimensional MRI assessment used to evaluate MMD. These MRI techniques span from basic cross-sectional to advanced functional sequences, both qualitative and quantitative. The aim of this review was to provide a comprehensive summary and analysis of current key relevant literature of advanced MRI techniques for the evaluation of MMD with image-rich case examples. These imaging methods can aid clinical characterization, help direct treatment, assist in the evaluation of treatment response, and potentially improve the understanding of the pathophysiology of MMD.
The effect of spiral trajectory correction on pseudo‐continuous arterial spin labeling with high‐performance gradients on a compact 3T scanner
Kang, Daehun , Yarach, Uten , In, Myung‐Ho , Gray, Erin M. , Trzasko, Joshua D. , Shu, Yunhong , Bernstein, Matt A. , Bernstein, Matt A , Kang, Daehun , In, Myung-Ho , Jo, Hang Joon , Huston, John

Mayo Clinic

Magnetic Resonance in Medicine | December 4, 2019 | Volume: 84 | Issue: 1 | Pages: 192-205

10.1002/mrm.28110 | PMID 31799747 Get It

PurposeTo demonstrate the feasibility of pseudo‐continuous arterial‐spin–labeled (pCASL) imaging with 3D fast‐spin‐echo stack‐of‐spirals on a compact 3T scanner (C3T), to perform trajectory correction for eddy‐current–induced deviations in the spiral readout of pCASL imaging, and to assess the correction effect on perfusion‐related images with high‐performance gradients (80 mT/m, 700T/m/s) of the C3T.MethodsTo track eddy‐current–induced artifacts with Archimedean spiral readout, the spiral readout in pCASL imaging was performed with 5 different peak gradient slew rate (Smax) values ranging from 70 to 500 T/m/s. The trajectory for each Smax was measured using a dynamic field camera and applied in a density‐compensated gridding image reconstruction in addition to the nominal trajectory. The effect of the trajectory correction was assessed with perfusion‐weighted (ΔM) images and proton‐density–weighted images as well as cerebral blood flow (CBF) maps, obtained from 10 healthy volunteers.ResultsBlurring artifact on ΔM images was mitigated by the trajectory correction. CBF values on the left and right calcarine cortices showed no significant difference after correction. Also, the signal‐to‐noise ratio of ΔM images improved, on average, by 7.6% after correction (P < .001). The greatest improvement of 12.1% on ΔM images was achieved with a spiral readout using Smax of 300~400 T/m/s.ConclusionEddy currents can cause spiral trajectory deviation, which leads to deformation of the CBF map even in cases of low value Smax. The trajectory correction for spiral‐readout–based pCASL produces more reliable results for perfusion imaging. These results suggest that pCASL is feasible on C3T with high‐performance gradients.
Phantom validation of quantitative susceptibility and dynamic contrast‐enhanced permeability MR sequences across instruments and sites
Hobson, Nicholas , Polster, Sean P. , Flemming, Kelly D. , Shu, Yunhong , Huston, John , Gerrard, Chandra Y., Selwyn, Reed , Mabray, Marc C. , Zafar, Atif , Girard, Romuald , Carrión‐Penagos, Julián , Chen, Yu Fen, Parrish, Todd B. , Zhou, Xiaohong Joe , Stadnik, Agnieszka , Koskimäki, Janne , Turley, Dallas, Awad, Issam A. , Flemming, Kelly, Girard, Romuald , Carrión-Penagos, Julián , Zhou, Xiaohong Joe , Mabray, Marc C , Flemming, Kelly D , Hobson, Nicholas , Polster, Sean P , Cao, Ying , Koenig, James I. , Shenkar, Robert , Dimov, Alexey , Carroll, Timothy

Mayo Clinic

Journal of Magnetic Resonance Imaging | September 13, 2019 | Volume: 51 | Issue: 4 | Pages: 1192-1199

10.1002/jmri.26927 | PMID 31515878 Get It

BackgroundQuantitative susceptibility mapping (QSM) and dynamic contrast‐enhanced quantitative permeability (DCEQP) on magnetic resonance (MR) have been shown to correlate with neurovascular disease progression as markers of vascular leakage and hemosiderin deposition. Applying these techniques as monitoring biomarkers in clinical trials will be necessary; however, their validation across multiple MR platforms and institutions has not been rigorously verified.PurposeTo validate quantitative measurement of MR biomarkers on multiple instruments at different institutions.Study TypePhantom validation between platforms and institutions.Phantom ModelT1/susceptibility phantom, two‐compartment dynamic flow phantom.Field Strength/Sequence3T/QSM, T1 mapping, dynamic 2D SPGR.AssessmentPhilips Ingenia, Siemens Prisma, and Siemens Skyra at three different institutions were assessed. A QSM phantom with concentrations of gadolinium, corresponding to magnetic susceptibilities of 0, 0.1, 0.2, 0.4, and 0.8 ppm was assayed. DCEQP was assessed by measuring a MultiHance bolus as the consistency of the width ratio of the curves at the input and outputs over a range of flow ratios between outputs.Statistical TestsEach biomarker was assessed by measures of accuracy (Pearson correlation), precision (paired t‐test between repeated measurements), and reproducibility (analysis of covariance [ANCOVA] between instruments).ResultsQSM accuracy of r2 > 0.997 on all three platforms was measured. Precision (P = 0.66 Achieva, P = 0.76 Prisma, P = 0.69 Skyra) and reproducibility (P = 0.89) were good. T1 mapping of accuracy was r2 > 0.98. No significant difference between width ratio regression slopes at site 2 (P = 0.669) or site 3 (P = 0.305), and no significant difference between width ratio regression slopes between sites was detected by ANCOVA (P = 0.48).Data ConclusionThe phantom performed as expected and determined that MR measures of QSM and DCEQP are accurate and consistent across repeated measurements and between platforms.Level of Evidence: 1Technical Efficacy Stage: 2J. Magn. Reson. Imaging 2020;51:1192–1199.
Presymptomatic Screening for Intracranial Aneurysms in Patients with Autosomal Dominant Polycystic Kidney Disease
Sanchis, Irina M., Shukoor, Shehbaz, Irazabal, María V. , Madsen, Charles D. , Hogan, Marie C. , Zoghby, Ziad , Harris, Peter C. , Brown, Robert D., Torres, Vicente E. , El-Zoghby, Ziad , Harris, Peter C , Torres, Vicente E , Irazabal, Maria V , Hogan, Marie C , Chebib, Fouad T. , Huston, John

Mayo Clinic

Clinical Journal of the American Society of Nephrology | July 30, 2019 | Volume: 14 | Issue: 8 | Pages: 1151-1160

10.2215/cjn.14691218 | PMID 31362991 Get It

Background and objectives Intracranial aneurysm rupture is the most devastating complication of autosomal dominant polycystic kidney disease. Whether selective or widespread intracranial aneurysm screening is indicated remains controversial. Design, setting, participants & measurements Records of 3010 patients with autosomal dominant polycystic kidney disease evaluated at the Mayo Clinic between 1989 and 2017 were reviewed. Those who had presymptomatic magnetic resonance angiography screening were included. Results Ninety-four intracranial aneurysms were diagnosed in 75 of 812 (9%) patients who underwent magnetic resonance angiography screening. Sex, age, race, and genotype were similar in the groups with and without aneurysms; hypertension and history of smoking were more frequent in the aneurysm group. Twenty-nine percent of patients with aneurysms compared with 11% of those without aneurysms had a family history of subarachnoid hemorrhage ( P <0.001). Most aneurysms were small (median diameter =4 mm; range, 2–12 mm); 85% were in the anterior circulation. During a total imaging follow-up of 469 patient-years, de novo intracranial aneurysms were detected in five patients; eight intracranial aneurysms grew (median =2 mm; range, 1–3 mm). During a total clinical follow-up of 668 patient-years, seven patients had preemptive clipping or coil embolization; no intracranial aneurysms ruptured. During a total clinical follow-up of 4783 patient-years in 737 patients with no intracranial aneurysm detected on the first magnetic resonance angiography screening, two patients had an intracranial aneurysm rupture (0.04 per 100 person-years; 95% confidence interval, 0 to 0.10). The rate of intracranial aneurysm rupture in large clinical trials of autosomal dominant polycystic kidney disease was 0.04 per 100 patient-years (95% confidence interval, 0.01 to 0.06). Conclusions Intracranial aneurysms were detected by presymptomatic screening in 9% of patients with autosomal dominant polycystic kidney disease, more frequently in those with familial history of subarachnoid hemorrhage, hypertension, or smoking. None of the patients with and two of the patients without aneurysm detection on screening suffered aneurysmal ruptures. The overall rupture rate in our autosomal dominant polycystic kidney disease cohort was approximately five times higher than that in the general population.
Distortion‐free imaging: A double encoding method (DIADEM) combined with multiband imaging for rapid distortion‐free high‐resolution diffusion imaging on a compact 3T with high‐performance gradients
In, Myung‐Ho , Tan, Ek T. , Trzasko, Joshua D. , Shu, Yunhong , Yarach, Uten , Tao, Shengzhen , Gray, Erin M. , Tao, Shengzhen , Tan, Ek T , Kang, Daehun , Huston, John , Bernstein, Matt A. , In, Myung-Ho

Mayo Clinic

Journal of Magnetic Resonance Imaging | May 21, 2019 | Volume: 51 | Issue: 1 | Pages: 296-310

10.1002/jmri.26792 | PMID 31111581 Get It

BackgroundDistortion‐free, high‐resolution diffusion imaging using DIADEM (Distortion‐free Imaging: A Double Encoding Method), proposed recently, has great potential for clinical applications. However, it can suffer from prolonged scan times and its reliability for quantitative diffusion imaging has not been evaluated.PurposeTo investigate the clinical feasibility of DIADEM‐based high‐resolution diffusion imaging on a novel compact 3T (C3T) by evaluating the reliability of quantitative diffusion measurements and utilizing both the high‐performance gradients (80 mT/m, 700 T/m/s) and the sequence optimization with the navigator acquisition window reduction and simultaneous multislice (multiband) imaging.Study TypeProspective feasibility study.Phantom/SubjectsDiffusion quality control phantom scans to evaluate the reliability of quantitative diffusion measurements; 36 normal control scans for B0‐field mapping; six healthy and two patient subject scans with a brain tumor for comparisons of diffusion and anatomical imaging.Field Strength/Sequence3T; the standard single‐shot echo‐planar‐imaging (EPI), multishot DIADEM diffusion, and anatomical (2D‐FSE [fast‐spin‐echo], 2D‐FLAIR [fluid‐attenuated‐inversion‐recovery], and 3D‐MPRAGE [magnetization prepared rapid acquisition gradient echo]) imaging.AssessmentThe scan time reduction, the reliability of quantitative diffusion measurements, and the clinical efficacy for high‐resolution diffusion imaging in healthy control and brain tumor volunteers.Statistical TestBland–Altman analysis.ResultsThe scan time for high in‐plane (0.86 mm2) resolution, distortion‐free, and whole brain diffusion imaging were reduced from 10 to 5 minutes with the sequence optimizations. All of the mean apparent diffusion coefficient (ADC) values in phantom were within the 95% confidence interval in the Bland–Altman plot. The proposed acquisition with a total off‐resonance coverage of 597.2 Hz wider than the expected bandwidth of 500 Hz in human brain could yield a distortion‐free image without foldover artifacts. Compared with EPI, therefore, this approach allowed direct image matching with the anatomical images and enabled improved delineation of the tumor boundaries.Data ConclusionThe proposed high‐resolution diffusion imaging approach is clinically feasible on C3T due to a combination of hardware and sequence improvements.Level of Evidence3Technical EfficacyStage 1 J. Magn. Reson. Imaging 2020;51:296–310.
Abstract TP582: A Multi-Site Validation of MRI Biomarkers of Vascular Leak and Hemorrhage for Forthcoming Clinical Trials
Hobson, Nick, Turley, Dallas, Cao, Ying , Selwyn, Reed , Stadnik, Agnieszka , Carroll, Timothy , Awad, Issam A. , Polster, Sean P. , Flemming, Kelly D. , Huston, John , Morrison, Leslie , Girard, Romuald , Hanley, Daniel F. , Koskimäki, Janne , Shenkar, Robert

Mayo Clinic

Stroke | January 30, 2019 | Volume: 50 | Issue: Suppl_1 | Pages: No page available

10.1161/str.50.suppl_1.tp582 Get It

Background: Cerebral cavernous malformation is a genetic neurovascular disorder causing aberrant angiogenesis and lesion development within capillary beds. Lesions exhibit impaired endothelial barrier function, causing blood-brain barrier leakage and hemorrhage. Quantitative MRI biomarkers (dynamic contrast-enhanced quantitative permeability (DCEQP) and quantitative susceptibility mapping (QSM)) have been shown to correlate with CCM disease progression as measures of barrier leakage and hemorrhagic iron deposition, and there is interest in utilizing these biomarkers as endpoints in clinical trials. However, their consistencies across multiple platforms and institutions has not yet been rigorously verified. Materials and Methods: Instruments used were a 3T Philips Ingenia at University of Chicago and a 3T Siemens Prisma at Northwestern University. QSM was assessed by five balloons filled with varying concentrations of MultiHance, corresponding to magnetic susceptibilities of 0, 0.1, 0.2, 0.4, and 0.8, surrounded by an agarose gel. Permeability was assessed by the injection of a bolus of MultiHance through a coiled hose inside a water-filled shell, and the consistency of the peak-to-peak ratio of the curves at the input and output was measured. Each biomarker was assessed by accuracy (to expected values, Pearson correlation), precision (between repeated measurements, paired t-test), and reproducibility (between instruments, paired t-test). Results: QSM measured with an accuracy of r 2 = 0.997 on the Philips Achieva and r 2 = 0.999 on the Siemens Prisma. Each scanner had adequate precision between measurements, showing no significant difference by a paired t-test (p = 0.66 Achieva, p = 0.45 Prisma), and the reproducibility between scanners also showed no significant difference (p = 0.89). The peak-to-peak ratio on DCEQP scans was accurate (r 2 = 0.998), precise between measurements (p = 0.54), and repeatable between instruments (p = 0.49). Conclusion: Quantitative imaging biomarkers DCEQP and QSM are accurate, consistent across multiple measurements, and between platforms and will be useful for future clinical trials in CCM.
Abstract TMP96: Carotid Plaque Characteristics Correlated to Baseline Vascular Risk Factors in a Large Randomized Trial: Results from CREST-2
Lal, Brajesh K. , Chrencik, Matthew T. , Khan, Amir , Jones, Michael , Sternbergh, Charles, Rapp, Joseph H., Mukherjee, Dipankar , Henke, Peter K. , Yokemick, John, Moore, Wesley S. , Voeks, Jenifer H. , Brott, Thomas G. , Huston, John , Sikdar, Siddhartha , Howard, George , Meschia, James F.

Mayo Clinic

Stroke | January 30, 2019 | Volume: 50 | Issue: Suppl_1 | Pages: No page available

10.1161/str.50.suppl_1.tmp96 Get It

Objectives: Assessment of carotid disease is most commonly performed with duplex ultrasonography (DUS). Measures of plaque area and tissue composition from DUS images may identify patients at risk for future neurologic events, and may assess the effects of vascular risk-factor modification (by measuring change in plaque area and/or tissue constituents). We quantified plaque area and tissue constituents from DUS images of CREST-2 participants at baseline and correlated them with their baseline vascular risk factors. Methods: CREST-2 consists of two multicenter, randomized trials in patients with asymptomatic ≥70% carotid stenosis comparing intensive medical management (IMM) plus endarterectomy or stenting vs IMM alone. Baseline B-mode DUS images from 500 patients underwent manual plaque outlining and automatic pixel brightness assessment. Plaque area, grayscale median (GSM), Gray-Weale score for heterogeneity, and areas for intraplaque hemorrhage and lipid were the output parameters. We computed the parameter estimates (95% confidence intervals) for baseline patient characteristics (age, sex, race, diabetes, smoking, BMI, blood pressure and LDL levels) versus plaque characteristics. Results: High-risk plaque features (larger plaque area, lower GSM , lower Gray-Weale scores, or larger areas of hemorrhage and lipid) were present in older patients, males, and those with elevated diastolic blood pressure and LDL levels (Table). Conclusions: In a randomized trial of asymptomatic patients with high-grade carotid stenosis, DUS-based computation of plaque geometry and tissue composition is feasible. Elevated diastolic blood pressure and LDL levels at baseline are associated with high-risk plaque characteristics. These novel findings identify potentially modifiable targets for aggressive treatment to reduce stroke-risk in patients with carotid stenosis.