Abstract Postmortem computed tomography (PMCT) has been integrated into the practice of many forensic pathologists. To evaluate the utility of PMCT in supplementing and/or supplanting medicolegal autopsy, we conducted a prospective double‐blind comparison of abnormal findings reported by the autopsy pathologist with those reported by a radiologist reviewing the PMCT. We reviewed 890 cases: 167 with blunt force injury (BFI), 63 with pediatric trauma (under 5 years), 203 firearm injuries, and 457 drug poisoning deaths. Autopsy and radiology reports were coded using the Abbreviated Injury Scale and abnormal findings and cause of death (COD) were compared for congruence in consensus conferences with novel pathologists and radiologists. Overall sensitivity for recognizing abnormal findings was 71% for PMCT and 74.6% for autopsy. Sensitivities for PMCT/autopsy were 74%/73.1% for BFI, 61.5%/71.4% for pediatric trauma, 84.9%/83.7% for firearm injuries, and 56.5%/66.4% for drug poisoning deaths. COD assigned by reviewing PMCT/autopsy was correct in 88%/95.8% of BFI cases, 99%/99.5% of firearm fatalities, 82.5%/98.5% of pediatric trauma deaths, and 84%/100% of drug poisoning deaths of individuals younger than 50. Both autopsy and PMCT were imperfect in recognizing injuries. However, both methods identified the most important findings and are sufficient to establish COD in cases of BFI, pediatric trauma, firearm injuries and drug poisoning in individuals younger than 50. Ideally, all forensic pathologists would have access to a CT scanner and a consulting radiologist. This would allow a flexible approach that meets the diagnostic needs of each case and best serves decedents' families and other stakeholders.
Phantom validation of quantitative susceptibility and dynamic contrast‐enhanced permeability MR sequences across instruments and sites
Journal of Magnetic Resonance Imaging | September 13, 2019 | Volume: 51 | Issue: 4 | Pages: 1192-1199
BackgroundQuantitative susceptibility mapping (QSM) and dynamic contrast‐enhanced quantitative permeability (DCEQP) on magnetic resonance (MR) have been shown to correlate with neurovascular disease progression as markers of vascular leakage and hemosiderin deposition. Applying these techniques as monitoring biomarkers in clinical trials will be necessary; however, their validation across multiple MR platforms and institutions has not been rigorously verified.PurposeTo validate quantitative measurement of MR biomarkers on multiple instruments at different institutions.Study TypePhantom validation between platforms and institutions.Phantom ModelT1/susceptibility phantom, two‐compartment dynamic flow phantom.Field Strength/Sequence3T/QSM, T1 mapping, dynamic 2D SPGR.AssessmentPhilips Ingenia, Siemens Prisma, and Siemens Skyra at three different institutions were assessed. A QSM phantom with concentrations of gadolinium, corresponding to magnetic susceptibilities of 0, 0.1, 0.2, 0.4, and 0.8 ppm was assayed. DCEQP was assessed by measuring a MultiHance bolus as the consistency of the width ratio of the curves at the input and outputs over a range of flow ratios between outputs.Statistical TestsEach biomarker was assessed by measures of accuracy (Pearson correlation), precision (paired t‐test between repeated measurements), and reproducibility (analysis of covariance [ANCOVA] between instruments).ResultsQSM accuracy of r2 > 0.997 on all three platforms was measured. Precision (P = 0.66 Achieva, P = 0.76 Prisma, P = 0.69 Skyra) and reproducibility (P = 0.89) were good. T1 mapping of accuracy was r2 > 0.98. No significant difference between width ratio regression slopes at site 2 (P = 0.669) or site 3 (P = 0.305), and no significant difference between width ratio regression slopes between sites was detected by ANCOVA (P = 0.48).Data ConclusionThe phantom performed as expected and determined that MR measures of QSM and DCEQP are accurate and consistent across repeated measurements and between platforms.Level of Evidence: 1Technical Efficacy Stage: 2J. Magn. Reson. Imaging 2020;51:1192–1199.