Citations

Showing 10 of 108015 citations.

Effects of Increased Free Fatty Acid Availability on Adipose Tissue Fatty Acid Storage in Men
Koutsari, Chistina, Jensen, Michael D. , Mundi, Manpreet S.

Mayo Clinic

The Journal of Clinical Endocrinology & Metabolism | September 5, 2014 | Volume: 99 | Issue: 12 | Pages: E2635-E2642

10.1210/jc.2014-2690 | PMID 25192251 Get It

Context:A portion of free fatty acids (FFA) released from adipose tissue lipolysis are re-stored in adipocytes via direct uptake. Rates of direct adipose tissue FFA storage are much greater in women than men, but women also have greater systemic FFA flux and more body fat.Objective:We tested the hypotheses that experimental increases in FFA in men would equalize the rates of direct adipose tissue FFA storage in men and women.Design:We used a lipid emulsion infusion to raise FFA in men to levels seen in post-absorptive women. Direct FFA storage (μmol·kg fat−1·min−1) rates in abdominal and femoral fat was assessed using stable isotope tracer infusions to measure FFA disappearance rates and an iv FFA radiotracer bolus/timed biopsy.Setting:These studies were performed in a Clinical Research Center.Participants:Data from 13 non-obese women was compared with that from eight obese and eight non-obese men.Intervention:The men received a lipid emulsion infusion to raise FFA.Main Outcome Measures:We measured the rates of direct FFA storage in abdominal and femoral adipose tissue.Results:The three groups were similar in age and FFA flux by design; obese men had similar body fat percentage as non-obese women. Despite matching for FFA concentrations and flux, FFA storage per kg abdominal (P < .01) and femoral (P < .001) fat was less in both lean and obese men than in non-obese women. Abdominal FFA storage rates were correlated with proteins/enzymes in the FFA uptake/triglyceride synthesis pathway in men.Conclusion:The lesser rates of direct FFA adipose tissue in men compared with women cannot be explained by reduced FFA availability.
A Weekend Call
Mansel, J. Keith

Mayo Clinic

Journal of Palliative Medicine | September 5, 2014 | Volume: 17 | Issue: 9 | Pages: 1072-1072

10.1089/jpm.2013.0575 | PMID 25192066 Get It

Factors contributing to the yield of asymmetric bilateral implantation of intracranial electrodes
Lee, Ricky W. , Mandrekar, Jay , Cascino, Gregory D. , Wetjen, Nicholas M. , Meyer, Fredric B. , Marsh, W. Richard , So, Elson, Worrell, Gregory A. , Wirrell, Elaine , So, Elson L.

Mayo Clinic

Epilepsia | September 5, 2014 | Volume: 55 | Issue: 10 | Pages: 1620-1625

10.1111/epi.12766 | PMID 25196143 Get It

SummaryObjectiveTo determine the outcome of implanting fewer electrodes over the hemisphere with less supporting presurgical localizing data.MethodsWe retrospectively reviewed our epilepsy surgery database at Mayo Clinic, Rochester, Minnesota, between January 1, 1999, and December 31, 2011, to identify patients who had an asymmetric number of electrode contacts implanted in each hemisphere for seizure localization. We scored each presurgical noninvasive data point (0, 0.5, or 1) to predict the likelihood of identifying seizure onset in the hemisphere with fewer intracranial electrode contacts (HFEC). An aggregate score was obtained for each patient.ResultsThirteen (37%) of 35 patients had HFEC‐onset seizures on intracranial electroencephalography (iEEG). The following factors predicted HFEC‐onset seizures: (1) temporal lobe epilepsy (p = 0.02); (2) interictal scalp electroencephalographic discharges at the HFEC (p = 0.04); and (3) both interictal and ictal scalp EEG discharges at the HFEC (p = 0.01). The median (range) aggregate score was 2 (1–3) for patients with HFEC‐onset seizures recorded on iEEG and 1 (0–3) for patients without HFEC‐onset seizures (p = 0.001). Using this scoring model, the odds ratio of identifying HFEC‐onset seizures on iEEG was 6.4 for each one‐point increment in the aggregate score. The area under the receiver operating characteristic curve for this model was 0.84, suggesting excellent ability of the aggregate score to discriminate between patients with and without HFEC‐onset seizures on iEEG.SignificanceImplanting electrodes on the basis of limited supporting presurgical data may be useful in selected patients, especially those with temporal lobe epilepsy, interictal scalp discharges involving the HFEC, or both interictal and ictal scalp discharges involving the HFEC. In addition, our proposed scoring system may be helpful in selecting patients with complicated epilepsy for implantation of an asymmetric number of intracranial electrodes in the hemispheres.
Prevention of Staphylococcus Epidermidis Biofilm Formation Using Electrical Current
Pozo, José Luís del , Rouse, Mark S., Euba, Gorane , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Steckelberg, James M., Patel, Robin , Del Pozo, Jose L, Patel, Robin

Mayo Clinic

Journal of Applied Biomaterials & Functional Materials | September 5, 2014 | Volume: 12 | Issue: 2 | Pages: 81-83

10.5301/jabfm.5000208 | PMID 25097026 Get It

A technique for the prevention of staphylococcal adhesion by electrical current exposure was investigated. Teflon coupons were exposed to a continuous flow of 10 3 cfu/ml Staphylococcus epidermidis with or without 2000 microA DC electrical current delivered by electrodes on opposite sides of a coupon, touching neither each other nor the coupon. A mean 3.46 (SD, 0.20) and 5.70 (SD, 1.03) log 10 cfu/cm 2 were adhered to the non-electrical current exposed coupons after 4 h and 24 h, respectively. A mean 2.46 (SD, 0.31) and 1.47 (SD, 0.73) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by graphite electrodes. A mean 2.21 (SD, 0.14) and 0.55 (SD, 0.00) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by stainless steel electrodes. Electrical current may be useful in the prevention of staphylococcal adhesion to biomaterials.
Labral Injury: Radiographic Predictors at the Time of Hip Arthroscopy
Redmond, John M., Gupta, Asheesh, Hammarstedt, Jon E. , Stake, Christine E. , Dunne, Kevin , Domb, Benjamin G.

Mayo Clinic

Arthroscopy | September 5, 2014 | Volume: 31 | Issue: 1 | Pages: 51-56

10.1016/j.arthro.2014.07.002 | PMID 25200941 Get It

Purpose The purpose of this study was to investigate the influence of multiple demographic and radiographic findings on the size of labral tears identified at the time of hip arthroscopy. Methods Data were prospectively collected for patients treated with arthroscopic labral repair or debridement from February 2008 to August 2011. Preoperative radiographic and demographic data were collected for 392 patients during the study period. Exclusion criteria included revision surgery and previous hip conditions. An anteroposterior pelvic view, 45° Dunn view, and false‐profile view were used to measure Tönnis grade, neck‐shaft angle, alpha angle, lateral center edge angle (LCEA), anterior center edge angle (ACEA), acetabular inclination, and the extent of crossover sign when present. At the time of surgery, labral tear size and location were documented for all patients, using traditional acetabular clock face nomenclature for sizing. A multiple linear regression analysis was then performed to assess the correlation of radiographic and demographic findings with the size of the labral tear. Results Regression analysis displayed statistical significance for sex ( P < .0001), age ( P < .0001), and alpha angle ( P = .005) with labral tear size. For female patients, Tönnis grade ( P = .0004) and neck‐shaft angle ( P = .004) correlated with labral tear size. This model accounted for only 26% of variation in labral tear size. Conclusions Preoperative risk factors for the extent of labral tear size are male sex, increasing age, and increasing alpha angle. Labral tears were larger in female patients with higher Tönnis grades and lower neck‐shaft angles. Measurements of acetabular coverage and version showed no correlation with labral tear size. The majority of labral tear size variation was not accounted for in this model. Level of Evidence Level IV, therapeutic case series.
The Hemodynamic Basis of Exercise Intolerance in Tricuspid Regurgitation
Andersen, Mads J. , Borlaug, Barry A. , Nishimura, Rick A. , Borlaug, Barry A , Andersen, Mads Jønsson

Mayo Clinic

Circulation: Heart Failure | September 5, 2014 | Volume: 7 | Issue: 6 | Pages: 911-917

10.1161/circheartfailure.114.001575 | PMID 25190672 Get It

Background— Patients with severe tricuspid regurgitation (TR) frequently present with exertional fatigue and dyspnea, but the hemodynamic basis for exercise limitation in people with TR remains unclear. Methods and Results— Twelve subjects with normal left ventricular (LV) ejection fraction and grade ≥3 TR underwent high-fidelity invasive hemodynamic exercise testing with simultaneous expired gas analysis and were compared with 13 age- and sex-matched controls. At rest, TR subjects had lower pulmonary blood flow (3.6±0.4 versus 5.1±1.9 L/min; P =0.01), increased right atrial pressure (12±5 versus 4±1 mm Hg; P =0.0002), and higher pulmonary capillary wedge pressure (17±5 versus 9±3 mm Hg; P =0.0001). However, LV transmural pressure (pulmonary capillary wedge pressure−right atrial pressure), which reflects LV preload independent of right heart congestion and pericardial restraint, was similar in TR and controls (6±3 versus 4±2 mm Hg; P =0.3). With exercise, TR subjects displayed lower peak V O 2 (10.3±2.8 versus 13.8±4.2 mL/min per kg; P =0.02), lower pulmonary blood flow (6.4±1.3 versus 10.3±3.3 L/min; P =0.001), and less increase in pulmonary blood flow relative to V O 2 (+4.6±1.1vs +6.2±0.7; P =0.001). TR subjects displayed higher pulmonary capillary wedge pressure with exercise, but this was solely because of RA hypertension (27±9 versus 8±3 mm Hg; P <0.0001), because LV transmural pressure dropped with exercise in subjects with TR (−5±6 versus +3±3 mm Hg; P =0.0007), suggesting inadequate LV diastolic filling, despite high pulmonary capillary wedge pressure. Conclusions— Impaired exercise capacity in people with severe TR is related to low cardiac output reserve relative to metabolic needs, coupled with elevated systemic and pulmonary venous pressures. Left heart pressures are elevated with exercise in subjects with TR, despite low LV preload, secondary to enhanced ventricular interaction.
High-intensity interval training vs. moderate-intensity continuous exercise training in heart failure with preserved ejection fraction: a pilot study
Angadi, Siddhartha S. , Mookadam, Farouk, Lee, Chong D. , Tucker, Wesley J. , Haykowsky, Mark J. , Mookadam, Farouk , Gaesser, Glenn A.

Mayo Clinic

Journal of Applied Physiology | September 5, 2014 | Volume: 119 | Issue: 6 | Pages: 753-758

10.1152/japplphysiol.00518.2014 | PMID 25190739 Get It

Heart failure with preserved ejection fraction (HFpEF) is a major cause of morbidity and mortality. Exercise training is an established adjuvant therapy in heart failure; however, the effects of high-intensity interval training (HIIT) in HFpEF are unknown. We compared the effects of HIIT vs. moderate-intensity aerobic continuous training (MI-ACT) on peak oxygen uptake (V̇o2peak), left ventricular diastolic dysfunction, and endothelial function in patients with HFpEF. Nineteen patients with HFpEF (age 70 ± 8.3 yr) were randomized to either HIIT (4 × 4 min at 85-90% peak heart rate, with 3 min active recovery) or MI-ACT (30 min at 70% peak heart rate). Fifteen patients completed exercise training (HIIT: n = 9; MI-ACT: n = 6). Patients trained 3 days/wk for 4 wk. Before and after training patients underwent a treadmill test for V̇o2peak determination, 2D-echocardiography for assessment of left ventricular diastolic dysfunction, and brachial artery flow-mediated dilation (FMD) for assessment of endothelial function. HIIT improved V̇o2peak (pre = 19.2 ± 5.2 ml·kg−1·min−1; post = 21.0 ± 5.2 ml·kg−1·min−1; P = 0.04) and left ventricular diastolic dysfunction grade (pre = 2.1 ± 0.3; post = 1.3 ± 0.7; P = 0.02), but FMD was unchanged (pre = 6.9 ± 3.7%; post = 7.0 ± 4.2%). No changes were observed following MI-ACT. A trend for reduced left atrial volume index was observed following HIIT compared with MI-ACT (−3.3 ± 6.6 vs. +5.8 ± 10.7 ml/m2; P = 0.06). In HFpEF patients 4 wk of HIIT significantly improved V̇o2peak and left ventricular diastolic dysfunction. HIIT may provide a more robust stimulus than MI-ACT for early exercise training adaptations in HFpEF.
Earl Wood–A research career noted for development of novel instruments driven by the power of the indicator dilution concept
Ritman, Erik L.

Mayo Clinic

Journal of Applied Physiology | September 5, 2014 | Volume: 117 | Issue: 9 | Pages: 945-956

10.1152/japplphysiol.00491.2014 | PMID 25190740 Get It

During World War 2, Earl Wood was charged with elucidating the biomedical factors in acceleration-induced loss of consciousness experienced by pilots in high-performance aircraft. For this, he developed devices for measurement and recording of blood pressure and tissue blood content. Those data lead to the design and fabrication of successful countermeasures to acceleration-induced loss of consciousness with an inflatable “G-suit” and “M1” breath-holding maneuver. After World War 2, he utilized and modified these instruments and made use of indicator dilution techniques by continuous intracardiac blood sampling to greatly increase the specificity and sensitivity of diagnosis of intracardiac anatomic and functional abnormalities in patients with congenital heart disease. This contributed to the greatly increased success rate of open-heart surgery in the 1950s. In the 1960s, he built on the then recently available video-coupled electronic X-ray image intensifier to develop X-ray fluoroscopy-based recording of indicator dilution signals in all cardiac chambers and surrounding great vessels without the need for placing catheter tips at those locations for blood sampling. However, these blood flow-related data were of limited value, as they were not measured concurrent with myocardial functional demand for perfusion. In the 1970s, he overcame this limitation by developing a high-speed multislice X-ray imaging scanner to provide tomographic images of concurrent dynamic cardiac anatomy and the indicator dilution-based estimates of blood flow distributions. On his retirement at age 70 in 1982, he had accomplished his 2 decade-old goal of the ability to make accurate concurrent, minimally invasive, and indicator dilution-based measurement of cardiovascular structure to function relationships.
Virtual Surgical Planning in Craniofacial Surgery
Wetjen, Nicholas M. , Mardini, Samir , Chim, Harvey , Wetjen, Nicholas

Mayo Clinic

Seminars in Plastic Surgery | September 4, 2014 | Volume: 28 | Issue: 03 | Pages: 150-158

10.1055/s-0034-1384811 | PMID 25210509 Get It

First Reported Case of Ehrlichia ewingii Involving Human Bone Marrow
Allen, Mr, Pritt, Bobbi S. , Sloan, Lynne M., Paddock, Christopher D. , Musham, Chaitanya K., Ramos, Jeanette M., Cetin, Neslihan, Rosenbaum, Eric , Pritt, Bobbi S

Mayo Clinic

Journal of Clinical Microbiology | September 4, 2014 | Volume: 52 | Issue: 11 | Pages: 4102-4104

10.1128/jcm.01670-14 | PMID 25187638 Get It

ABSTRACT A 65-year-old female with a history of multiple tick bites presented with fever and pancytopenia. Intracytoplasmic rickettsial morulae were detected on peripheral smear and bone marrow biopsy specimens, and PCR amplified Ehrlichia ewingii DNA from both specimens. To our knowledge, this is the first report of E. ewingii infection of human bone marrow.