Citations

Showing 10 of 107906 citations.

NGS-based monitoring of secondary acute lymphoblastic leukemia dynamics following lenalidomide maintenance in multiple myeloma patients
Calvillo, C. Daniel , Castro, Valentina Cardenas , Arribas, Mariano , Cardenas Castro, Valentina, Arana Yi, Cecilia , Shim, Kevin G. , Kirsch, Ilan R. , Fonseca, Rafaël , Yi, Cecilia Arana

Mayo Clinic

Leukemia & Lymphoma | November 19, 2025 | Volume: 67 | Issue: 2 | Pages: 342-348

10.1080/10428194.2025.2586084 | PMID 41257444 Get It

Pediatric Dermatology Learning Needs Identified Through Continuing Certification Program Assessments of the American Board of Dermatology
Stratman, Erik J. , Schaffer, Julie V., Miller, Stanley J., Bruckner, Anna L. , González, Mercedes E. , Zaenglein, Andrea L. , Roenigk, Randall K.

Mayo Clinic

Pediatric Dermatology | November 19, 2025 | Volume: 43 | Issue: 3 | Pages: 650-653

10.1111/pde.70076 | PMID 41257358 Get It

ABSTRACT The American Board of Dermatology (ABD) Continuing Certification Program (CCP) for board‐certified dermatologists helps advance its vision, which includes quarterly web‐based knowledge assessments. In 2022, the ABD began a review of gaps in knowledge assessment, practice improvement reporting, and areas of educational interest. The American Board of Medical Specialties directed member boards to share frequently occurring deficits with specialty societies to identify and prioritize gaps. This report summarizes pediatric dermatology findings from this review.
Patient wellness is linked to physician wellness
Brandenburg, Joline E. , Erlandson, Erika, Srinivasan, Rajashree , Sukhov, Renat

Mayo Clinic

Journal of Pediatric Rehabilitation Medicine | November 19, 2025 | Volume: 17 | Issue: 3 | Pages: 297-298

10.1177/18758894241282518 | PMID 39973580 Get It

Aggregation Periods Influence Step Count Error in Low-Power Wearables
Lundell, Sydney , Kaufman, Kenton R. , Kaufman, Kenton R

Mayo Clinic

Sensors | November 19, 2025 | Volume: 25 | Issue: 22 | Pages: 6998

10.3390/s25226998 | PMID 41305204 Get It

Wearable sensors are increasingly used to monitor physical activity, yet low-power devices often rely on data aggregation to conserve battery life, potentially impacting measurement accuracy. This study evaluates the performance of a new low-power wearable (LPW), designed for monitoring steps across multiple months in a free-living environment, compared to a research-grade sensor (RGS) that collects raw acceleration data, with a focus on how different aggregation intervals impact step count accuracy. Thirty-two participants wore both sensors over two days, with LPW data collected in 10 min, 1 min, or 10 s aggregation periods (APs). Sensitivity and specificity of wear time detection were high across all APs (0.96 and 0.98, respectively). While total daily step count error did not differ significantly between APs, the 10 min AP exhibited greater undercounting and wider limits of agreement, especially in APs containing more than 40 steps. These findings suggest that although AP does not affect total daily step count, it influences the accuracy and variability of more granular data windows. Aggregating step counts over longer intervals may obscure short, fragmented bouts common in daily activity, leading to underestimation of steps. Optimizing APs and sensor settings is critical for improving accuracy in low-power wearables used outside laboratory settings.
Response to Letter Regarding “Sodium–Glucose Cotransporter‐2 Inhibitors and Stroke Risk in Patients With Atrial Fibrillation”
Mee, Xuan Ci , Ibrahim, Ramzi , Lim, Ghee Kheng, Abdelnabi, Mahmoud , Habib, Eiad , Lee, Justin Z. , Lester, Steven J., Scott, Luis R. , Sorajja, Dan , Ayoub, Chadi , Mee, Xuan Ci , Ibrahim, Ramzi , Ibrahim, Ramzi , Lim, Ghee Kheng, Pham, Hoang Nhat , Farina, Juan M. , Lee, Kwan , Arsanjani, Reza

Mayo Clinic

Journal of Cardiovascular Electrophysiology | November 19, 2025 | Volume: 37 | Issue: 1 | Pages: 216-217

10.1111/jce.70189 | PMID 41255042 Get It

Impact of heart failure on in-hospital outcomes of pulmonary valve interventions: a nationwide analysis
Asnani, Heena , Oujamaa, Ider , Harmouch, Khaled M. , Sheffeh, Judy, Basit, Jawad , AlJaroudi, Wael A., Alraies, M Chadi, Sheffeh, Mohammad Ali , Turkmani, Mustafa , Alraies, M Chadi

Mayo Clinic

Future Cardiology | November 19, 2025 | Volume: 21 | Issue: 12 | Pages: 1045-1051

10.1080/14796678.2025.2591511 | PMID 41255017 Get It

Environmental Enrichment Suppresses Food Seeking and Increases Inhibitory Interneuron Excitability While Decreasing Corticothalamic Neuronal Recruitment in the Prelimbic Cortex
Peters, Kate Z. , Agbude, Romarua, Steele, Oliver G. , Suto, Nobuyoshi , Koya, Eisuke

Mayo Clinic

European Journal of Neuroscience | November 19, 2025 | Volume: 62 | Issue: 10 | Pages: No page available

10.1111/ejn.70315 | PMID 41254855 Get It

ABSTRACT Cues such as fast‐food advertisements associated with food can provoke food cravings which may lead to unhealthy overeating. To effectively control such cravings, we need to better understand the factors that reduce food cue reactivity and reveal corresponding ‘anti‐craving’ brain mechanisms. We previously reported that access to environmental enrichment (EE), that provides cognitive and physical stimulation in mice, reduced cue‐evoked sucrose seeking and prelimbic cortex (PL) neuronal reactivity. To date, the phenotype of PL neurons that undergo EE‐induced adaptations has not been fully elucidated. Therefore, we used brain slice electrophysiology to investigate how EE modulated intrinsic excitability in the general population of PL interneurons and pyramidal cells. Additionally, we used retrograde tracing and the neuronal activity marker ‘Fos’ to investigate how EE modulated cue‐evoked recruitment of pyramidal cells projecting to the paraventricular nucleus of the thalamus (PVT) and nucleus accumbens core (NAc). Before the cue‐evoked sucrose seeking test, EE increased the general, baseline excitability of inhibitory interneurons, but not pyramidal cells. During cue‐evoked sucrose seeking, EE selectively suppressed recruitment of corticothalamic (PL → PVT), but not corticoaccumbens (PL → NAc), projections. Collectively, these findings advance our understanding of EE's ‘anti–food‐seeking’ actions by demonstrating both cell type‐specific increases in local inhibitory tone and circuit‐specific modulation of PL output pathways.
Physiologically Adaptive Soft Millirobot for Atraumatic, Image-Guided Endovascular Therapy
Ceylan, Hakan , Alabay, Husnu Halid , Austin, Melissa, Urbina, Pamela Manco, Misra, Sanjay, Alabay, Husnu H., Manco Urbina, Pamela A, Ceylan, Hakan , Le, Tuan‐Anh , Singh, Prabh G. , Austin, Melissa, Urbina, Pamela Manco

Mayo Clinic

No container title available | November 19, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-8089047/v1 | PMID 41333416 Get It

Abstract Atraumatic and localized drug delivery to the vascular endothelium remains a critical unmet need in interventional medicine, with major implications for the management of arterial and venous diseases. Current approaches, such as drug-eluting stents and drug-coated balloons, combine mechanical revascularization with local drug release but frequently denude the endothelium and injure vessel walls, leading to restenosis, thrombosis, and chronic inflammatory repair cycles that severely limit long-term outcomes. Here, we present EndoBot, a soft, untethered millirobot designed for atraumatic navigation and targeted endovascular drug delivery during physiologic blood flow. EndoBot employs magnetically actuated corkscrew propulsion and mechanically adaptive surface crawling to maintain low radial pressure (<1 kPa) and preserve endothelial integrity. Its feasibility is established in arterial and venous phantom models, ex vivo human umbilical veins under normothermic perfusion, and in vivo rat inferior vena cava, all under clinical fluoroscopic guidance using a human-scale magnetic manipulation system. Despite periodic vessel motion, compression, and geometric irregularities, EndoBot maintains stable, mechanically adaptive navigation without endothelial injury. Under real-time fluoroscopic imaging, we identify key challenges and showcase clinically feasible strategies for 3D localization and tracking, overcoming intrinsic depth limitations of 2D clinical imaging. The device can be deployed and retrieved through standard vascular sheaths and remains stable under supraphysiologic arterial and venous flow conditions (flow rate >100 mL min-1; flow velocity >155 cm s-1, shear stress >10 Pa). Blood-compatibility testing demonstrates no increase in coagulation tendency and minimal hemolysis (<0.01%) during magnetic actuation. For drug delivery, EndoBot employs a novel endoluminal painting-based technique that transfers a hydrophobic and flow-resistant coating directly onto the inner vessel surface. This method ensures uniform deposition of a biodegradable drug depot without generating fragments larger than typical capillary diameters (>10 mm). By enabling local, atraumatic drug delivery without compromising vessel wall integrity, EndoBot first time demonstrates a translationally viable platform for exploring effectiveness in preventive interventions in early-stage vascular disease and for adjunctive therapies in advanced disease stages.
An automated daily QA strategy for dosimetry and imaging guidance check of a novel PET/CT ring gantry linac
Ghimire, Sagar, Park, Yang Kyun, Gibbard, Grant, Tan, Jun , Banks, T. , Shen, Chenyang , Zhuang, Tingliang , Godley, Andrew , Banks, Thomas I , Prasad, Rameshwar , Jiang, Steve B , Cai, Bin, Tan, Jun

Mayo Clinic

Journal of Applied Clinical Medical Physics | November 19, 2025 | Volume: 26 | Issue: 12 | Pages: No page available

10.1002/acm2.70309 | PMID 41253712 Get It

Abstract Background The RefleXion X1 is a novel PET/CT‐guided ring gantry linac that introduces unique geometry and workflow compared to conventional systems. Existing QA guidelines (AAPM TG‐142, 148, 306) cover standard linacs and tomotherapy but do not address this platform's needs. Therefore, an automated daily QA solution is required to ensure accurate output, imaging guidance, and couch positioning, which motivated the development and evaluation of the workflow presented in this study. Purpose To develop and evaluate an automated, efficient, and comprehensive daily quality assurance (QA) workflow for a novel PET/CT‐guided ring gantry linear accelerator (RefleXion X1), incorporating tests for dosimetry, imaging guidance, and couch positioning accuracy. Methods An IMRT QA plan was designed following the CT scan of the TomoDose 2D diode detector array (Sun Nuclear, Melbourne, FL) within the RefleXion treatment planning system (TPS). Several spherical targets of varying sizes were contoured to conform the dose distribution to these targets and evaluate beam output, laser localization, profile constancy, and CT‐MV isocenter coincidence. Linear models correlating spatial location of dose peak with intentional shifts in different directions were developed and integrated into an in‐house analysis software, iQA, written in C#. The software was validated for robustness and successfully implemented in clinical practice. Results Validation with 42 intentional shifts showed submillimeter accuracy, with mean deviations of 0.2 mm (X), 0.1 mm (Y), and 0.79 mm (Z), and R 2 values ≥ 0.98. Over 1 year, daily QA data showed stable output constancy (1.006 ± 0.016), left/right target dose constancy (1.007 ± 0.005 and 0.996 ± 0.004), and consistent CT‐MV isocenter offsets (–0.335 ± 0.23 mm in X, 0.19 ± 0.19 mm in Y, and –0.544 ± 0.36 mm in Z). The software also detected a gradual output drift in between, prompting a timely linac adjustment. Conclusion This fully automated, single‐delivery QA workflow enables efficient and robust evaluation of multiple IGRT performance parameters. It improves standardization, reduces human error, and reliably monitors long‐term machine stability. The tools and methodology may be adopted by other clinics seeking a practical and automated daily QA solution. Future developments will focus on incorporating PET QA and rotational couch validations to further enhance the system's comprehensiveness and adaptability.
Commissioning of a gantry‐mounted synchrocyclotron for preclinical FLASH studies utilizing spread‐out Bragg peaks
Zhang, Hailei , Owen, Daniel , Zhao, Tianyu , Darafsheh, Arash , Lowe, Michael

Mayo Clinic

Journal of Applied Clinical Medical Physics | November 19, 2025 | Volume: 26 | Issue: 12 | Pages: No page available

10.1002/acm2.70357 | PMID 41253689 Get It

Background Preclinical studies demonstrate the benefits of ultra‐high dose‐rate (FLASH) radiation, reducing normal tissue toxicity while maintaining tumoricidal effects. Proton FLASH (pFLASH) studies typically use transmission beams, missing the normal tissue‐sparing advantage of the spread‐out Bragg peak (SOBP). Purpose This study aims to propose and implement a series of modifications to enable a clinical Mevion S250i gantry‐mounted synchrocyclotron to deliver pFLASH within the SOBP of the proton beam. Methods A clinical synchrocyclotron was modified to enable FLASH proton beam delivery using the Mevion FLASH accessory kit, a commercially available tool that allows for the delivery of a single spot SOBP at FLASH dose rates. To ensure accurate beam monitoring, a Faraday cup was utilized to measure the integral charge per delivery at different dose rates and calibrate the FLASH transmission ion chamber (FLASHTic), which is integrated in the FLASH accessory mount attached to the nozzle of the gantry. The FLASHTic was specifically designed to prevent saturation at the dose rates associated with FLASH. To generate the desired single spot SOBP, boron carbide absorbers, a range modulating hole filter, and an 11‐mm‐diameter circle brass aperture were employed on the FLASH nozzle mount. Results The results indicate that the FLASHTic measurements demonstrated a strong correlation with the Faraday cup post calibration, suggesting that the FLASHTic can be effectively utilized for both monitoring and terminating the proton beam. The 80%–80% width of the SOBP was 2.01 cm. The peak dose rate at the SOBP proximal peak reached 105.03 Gy/s, with an average of 96.18 Gy/s over five days. Transitioning between FLASH and clinical mode required less than one hour without affecting the clinical beam. Conclusions The commissioning of a 230 MeV proton synchrocyclotron for SOBP FLASH delivery was achieved, providing a platform for preclinical small animal studies on pFLASH effects.