Citations

Showing 10 of 108036 citations.

Large B-cell transformation in nodular lymphocyte-predominant Hodgkin lymphoma: 40-year experience from a single institution
Kenderian, Saad S. , Macon, William R. , Ristow, Kay M., Ansell, Stephen M. , Johnston, Patrick B. , Inwards, David J. , Micallef, Ivana N. , Thompson, Carrie A. , Porrata, Luis F. , Martenson, James A., Nowakowski, Grzegorz S. , Kenderian, Saad Sirop , Habermann, Thomas M. , Colgan, Joseph P. , Markovic, Svetomir N. , Witzig, Thomas E.

Mayo Clinic

Blood | February 2, 2016 | Volume: 127 | Issue: 16 | Pages: 1960-1966

10.1182/blood-2015-08-665505 | PMID 26837698 Get It

Key Points The risk of transformation of NLPHL to DLBCL is 0.74 per 100 patient-years of follow-up. Risk factors for transformation include prior exposure to chemotherapy and splenic involvement at time of diagnosis.
Unique cause of right hemispheric syndrome: Embolism of myocardium after open septal myectomy
Murphy, Meghan E. , Raghunathan, Aditya , Schaff, Hartzell V. , Fugate, Jennifer E. , Schaff, Hartzell, Lanzino, Giuseppe , Raghunathan, Aditya , Schaff, Hartzell

Mayo Clinic

The Neuroradiology Journal | February 2, 2016 | Volume: 29 | Issue: 2 | Pages: 110-114

10.1177/1971400916628169 | PMID 26838173 Get It

We present a novel case of acute ischemic stroke in the postoperative setting of open septal myectomy. A 24-year-old woman developed acute left hemiparesis and rightward eye deviation the morning after surgery. She underwent emergent endovascular stoke therapy by mechanical embolectomy with successful retrieval of a fragment of myocardium that was obstructing the right middle cerebral artery. To our knowledge there has been no previous case described of a myocardial fragment causing a proximal intracranial artery occlusion with resulting ischemia and infarction.
Safety and Feasibility of Laparoscopic Abdominal Surgery in Patients With Mechanical Circulatory Assist Devices
Chapital, Alyssa B. , Johnson, Daniel J. , Staley, Linda L., Arabía, Francisco A. , Harold, Kristi L., Ashfaq, Awais , Ashfaq, Awais

Mayo Clinic

Surgical Innovation | February 2, 2016 | Volume: 23 | Issue: 5 | Pages: 469-473

10.1177/1553350616628679 | PMID 26839214 Get It

Objectives. Increasing number of mechanical circulatory assist devices (MCADs) are being placed in heart failure patients. Morbidity from device placement is high and the outcome of patients who require noncardiac surgery after, is unclear. As laparoscopic interventions are associated with decreased morbidity, we examined the impact of such procedures in these patients. Methods. A retrospective review was conducted on 302 patients who underwent MCAD placement from 2005 to 2012. All laparoscopic abdominal surgeries were included and impact on postoperative morbidity and mortality studied. Results. Ten out of 16 procedures were laparoscopic with 1 conversion to open. Seven patients had a HeartMate II, 2 had Total Artificial Hearts, and 1 had CentriMag. Four patients had devices for ischemic cardiomyopathy and 6 cases were emergent. Surgeries included 6 laparoscopic cholecystectomies, 2 exploratory laparoscopies, 1 laparoscopic colostomy takedown, and 1 laparoscopic ventral hernia repair with mesh. Median age of the patients was 63 years (range, 29-79 years). Median operative time was 123 minutes (range, 30-380 minutes). Five of 10 patients were on preoperative anticoagulation with average intraoperative blood loss of 150 mL (range, 20-700 mL). There were 3 postoperative complications; acute respiratory failure, acute kidney injury and multisystem organ failure resulting in death not related to the surgical procedure. Conclusion. The need for noncardiac surgery in post-MCAD patients is increasing due to limited donors and due to more durable and longer support from newer generation assist devices. While surgery should be approached with caution in this high-risk group, laparoscopic surgery appears to be a safe and successful treatment option.
Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array
Yu, Zhicong , Jorgensen, Steven M., Li, Zhoubo , Gutjahr, Ralf , Chen, Baiyu , Halaweish, Ahmed F., Kappler, S. , Yu, Lifeng , Ritman, Erik L., Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H.

Mayo Clinic

Physics in Medicine & Biology | February 2, 2016 | Volume: 61 | Issue: 4 | Pages: 1572-1595

10.1088/0031-9155/61/4/1572 | PMID 26835839 Get It

Abstract This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x-ray photon flux.
Analysis of fluid movement in skeletal muscle using fluorescent microspheres
Evertz, Loribeth Q., Greising, Sarah M. , Morrow, Duane A., Sieck, Gary C. , Kaufman, Kenton R. , Sieck, Gary , Kaufman, Kenton R

Mayo Clinic

Muscle & Nerve | February 2, 2016 | Volume: 54 | Issue: 3 | Pages: 444-450

10.1002/mus.25063 | PMID 26833456 Get It

ABSTRACTIntroductionRegional variability in interstitial fluid pressure confounds use of intramuscular pressure measurement to assess muscle force. It is hypothesized that interstitial flow is dependent on intramuscular pressure. The goal of this study was to assess the feasibility of using fluorescent microspheres to evaluate movement of interstitial fluid in skeletal muscle.MethodsTwo diameters of fluorescent microspheres were injected into the rat tibialis anterior during both static (n = 6) and passively lengthened (10% strain) experimental conditions (n = 6). Microsphere dispersion was evaluated using confocal imaging of transverse muscle sections.ResultsFluorescent microspheres tracked interstitial fluid while not penetrating the muscle fiber. When compared with the static condition, significantly greater dispersion (P = 0.003) was seen with passively lengthened conditions (17 ± 9% vs. 31 ± 7%, respectively). Dispersion did not differ for the 2 microsphere sizes (P = 0.811).ConclusionsFluorescent microspheres track movement of interstitial fluid, and dispersion is dependent on passive lengthening. Muscle Nerve 54: 444–450, 2016
Development of Liposomal Formulation for Delivering Anticancer Drug to Breast Cancer Stem-Cell-Like Cells and its Pharmacokinetics in an Animal Model
Ahmad, Ajaz , Mondal, Sujan Kumar , Banerjee‬‬‬‬‬‬‬‬‬, Rintu , Alkharfy, Khalid M. , Mukhopadhyay, Debabrata , Banerjee, Rajkumar

Mayo Clinic

Molecular Pharmaceutics | February 2, 2016 | Volume: 13 | Issue: 3 | Pages: 1081-1088

10.1021/acs.molpharmaceut.5b00900 | PMID 26832839 Get It

A targeted genetic association study of epithelial ovarian cancer susceptibility
Earp, Madalene A. , Winham, Stacey J. , Sicotte, Hugues , Chien, Jeremy , Goodman, Marc T. , Levine, Douglas A. , Monteiro, Álvaro N.A. , Ness, Roberta B., Pearce, Celeste Leigh, Rossing, Mary Anne, Tworoger, Shelley S. , Wentzensen, Nicolas , Bisogna, Maria, Brinton, Louise A. , Brooks‐Wilson, Angela , Carney, Michael E. , Cunningham, Julie M. , Edwards, Robert P., Fogarty, Zachary C. , Iversen, Edwin S., Kraft, Peter , Le, Nhu D. , Lin, Hui‐Yi , Lissowska, Jolanta , Moysich, Kirsten B. , Olson, Sara H. , Pike, Malcolm C. , Rider, David N., Terry, Kathryn L. , Thompson, Pamela J., Vierkant, Robert A. , Vitonis, Allison F., Wu, Anna H. , Phelan, Catherine M., Schildkraut, Joellen M. , Chen, Y. Ann , Sellers, Thomas A. , Goode, Ellen L. , Earp, Madalene, Larson, Nicholas, Larson, Nicholas B. , Permuth, Jennifer B. , Anton‐Culver, Hoda , Bandera, Elisa V. , Berchuck, Andrew , Cook, Linda S. , Cramer, Daniel W. , Doherty, Jennifer A. , Larson, Melissa C. , Modugno, Francesmary , Poole, Elizabeth M. , Berg, David Van Den , Wilkens, Lynne R. , Yang, Hannah , Ziogas, Argyrios , Fridley, Brooke L. , Winham, Stacey J , Tworoger, Shelley S , Vierkant, Robert A , Chien, Jeremey , Monteiro, Alvaro N , Moysich, Kirsten , Lissowska, Jolanta , Brooks-Wilson, Angela R , Lin, Hui-Yi , Fogarty, Zachary C , Kraft, Peter , Goodman, Marc T

Mayo Clinic

Oncotarget | February 2, 2016 | Volume: 7 | Issue: 7 | Pages: 7381-7389

10.18632/oncotarget.7121 | PMID 26848776 Get It

Three-Day-Old Boy With Palmar Pustules
Oza, Vikash S. , Asch, Sarah , Mathes, Erin F.

Mayo Clinic

JAMA Pediatrics | February 2, 2016 | Volume: 170 | Issue: 2 | Pages: 171

10.1001/jamapediatrics.2015.1996 | PMID 26830870 Get It

Diagnosing Testicular Torsion before Urological Consultation and Imaging: Validation of the TWIST Score
Sheth, Kunj , Keays, Mélise , Grimsby, Gwen M. , Granberg, Candace F. , Menon, Vani S. , DaJusta, Daniel , Ostrov, Lauren , Hill, Martinez, Sanchez, Emma, Kuppermann, David , Harrison, Clanton B., Jacobs, Micah A. , Huang, Rong , Burgu, Berk , Hennes, Halim , Schlomer, Bruce J., Baker, Linda A.

Mayo Clinic

Journal of Urology | February 2, 2016 | Volume: 195 | Issue: 6 | Pages: 1870-1876

10.1016/j.juro.2016.01.101 | PMID 26835833 Get It