Citations

Clear

949 citation(s) found for "Li, Bryan".

The cobas® 6800/8800 System: a new era of automation in molecular diagnostics
Cobb, Bryan, Simon, Christian O., Body, Barbara A., Mitchell, P. Shawn, Reisch, Nataša, Stevens, Wendy , Carmona, Sergio , Katz, Louis N., Will, Stephen, Liesenfeld, Oliver , Stramer, Susan L. , Katz, Louis

Mayo Clinic

Expert Review of Molecular Diagnostics | January 3, 2017 | Volume: 17 | Issue: 2 | Pages: 167-180

10.1080/14737159.2017.1275962 | PMID 28043179 Get It

Dementia Research—A Roadmap for the Next Decade
Rademakers, Rosa, Traynor, Bryan J.

Mayo Clinic

JAMA Neurology | December 12, 2016 | Volume: 74 | Issue: 2 | Pages: 141

10.1001/jamaneurol.2016.5004 | PMID 27942708 Get It

Outcomes of atrial arrhythmia radiofrequency catheter ablation in patients with Ebstein’s anomaly
Hassan, Abdalla, Tan, Nicholas Y. , Aung, Htin , Connolly, Heidi M. , Hodge, David O. , Vargas, Emily , Cannon, Bryan C. , Packer, Douglas L. , Asirvatham, Samuel J. , Vargas, Emily R, McLeod, Christopher J. , Asirvatham, Samuel J

Mayo Clinic

EP Europace | November 7, 2016 | Volume: 20 | Issue: 3 | Pages: 535-540

10.1093/europace/euw396 | PMID 28340054 Get It

Clinical Impact of Amyloid Positron Emission Tomography—Is It Worth the Cost?
Caselli, Richard J. , Woodruff, Bryan K.

Mayo Clinic

JAMA Neurology | November 1, 2016 | Volume: 73 | Issue: 12 | Pages: 1396

10.1001/jamaneurol.2016.3792 | PMID 27802483 Get It

Intravascular and hybrid intraoperative stent placement for baffle obstruction in transposition of the great arteries after atrial switch
Poterucha, Joseph T., Taggart, Nathaniel W. , Johnson, Jonathan N. , Cannon, Bryan C. , Hagler, Donald J. , Cetta, Frank , Cabalka, Allison K. , Dearani, Joseph A. , Taggart, Nathaniel W

Mayo Clinic

Catheterization and Cardiovascular Interventions | October 27, 2016 | Volume: 89 | Issue: 2 | Pages: 306-314

10.1002/ccd.26783 | PMID 27785879 Get It

ObjectivesTo report our experience with intravascular and hybrid intra‐operative stent placement for baffle obstruction in patients with complete transposition of the great arteries (TGA) after the atrial switch (Mustard/Senning) operation.BackgroundVenous baffle obstruction is a challenging complication after atrial switch operation in patients with TGA. Traditional treatment options include intravascular stenting or surgery.MethodsA retrospective analysis of Mayo Clinic's electronic medical record was completed to identify consecutive pediatric and adult patients with TGA after atrial switch who underwent baffle stent implantation from 1994 to 2015.ResultsOverall, 64 patients were referred for cardiac catheterization, in whom 47 (73%) were noted to have hemodynamic and angiographic evidence of baffle obstruction. A total of 20 patients mean age 33 (range: 8–46) years old underwent stent implantation of baffle stenosis at a mean of 33 (range: 7.5–45) years after initial atrial switch operation (Mustard, n = 19; Senning, n = 1). Overall, 27 baffles were stented in 20 patients via the following approaches: intravascular (17); hybrid surgical (3); staged intravascular & hybrid (2). Sites of stent placement were: superior vena cava (SVC) (13); inferior vena cava (IVC) (9); pulmonary venous baffle (5). Three patients had stent placement in the SVC and IVC baffles during the same procedure. Procedural adverse events occurred in 2/22 cases (9%) including creation of unintentional baffle leak (n = 1) and stent migration (n = 1). There was no procedure‐related mortality. At follow‐up (median 2, range 0.02–10 years), significantly improved NYHA class and mean Doppler baffle gradient were demonstrated (P < 0.05). Mild baffle re‐stenosis (mean Doppler gradient; 2–3 mmHg) occurred in two patients who have not required re‐intervention. Trivial baffle leak was noted in four patients. Baffle re‐intervention was only occurred in one patient. One patient with pre‐procedural Class IV symptoms died 3.5 months after stent implantation.ConclusionsThis study is the largest reported experience of intravascular and intra‐operative hybrid stent placement for patients with TGA after atrial switch. Transcatheter and minimally invasive hybrid intraoperative surgical stent placement are an effective strategy for relief of systemic and pulmonary venous baffle obstruction. © 2016 Wiley Periodicals, Inc.
High‐Frequency Spinal Cord Stimulation in a Patient with an Implanted Cardiac Device
Hoelzer, Bryan C. , Martin, David P. , Lamer, Tim J. , Kissoon, Narayan

Mayo Clinic

Pain Practice | October 22, 2016 | Volume: 17 | Issue: 4 | Pages: 558-563

10.1111/papr.12530 | PMID 27770599 Get It

AbstractBackgroundNew advances in spinal cord stimulation have led to improved treatment of patients suffering from chronic pain. While the overall safety of newer stimulation devices has been established, no published reports exist regarding safety considerations when these devices are implanted in patients with a preexisting cardiac device.Case ReportAn 83‐year‐old man with a history of out‐of‐hospital cardiac arrest secondary to an episode of ventricular fibrillation underwent automated implantable cardiac defibrillator placement. Concomitantly, he suffered from intractable chronic low axial back pain and was deemed a candidate for high‐frequency (10 kHz) spinal cord stimulation (SCS). Cardiac monitoring during SCS trial and implantation was performed with no interference noted. Following high‐frequency SCS implantation, the patient was observed to have significant pain relief with functional improvement.DiscussionWhile others have reported safety during traditional SCS in patients with implanted cardiac devices, this is the first case report to describe safe and effective use of high‐frequency SCS in a patient with an implanted cardiac device.
P3‐323: Prevalence of Autistic Traits in a Cognitively Normal Aging Cohort
Woodruff, Bryan K. , Snyder, Charlene R. Hoffman, Johnson, Travis A. , Henslin, Bruce R. , Caselli, Richard J. , Locke, Dona E.C.

Mayo Clinic

Alzheimer's & Dementia | October 17, 2016 | Volume: 12 | Issue: 7S_Part_19 | Pages: No page available

10.1016/j.jalz.2016.06.1987 Get It

Effectiveness of Ultrasound‐Guided Compared to Blind Steroid Injections in the Treatment of Carpal Tunnel Syndrome
Evers, Stefanie, Bryan, Andrew J., Sanders, Thomas L. , Selles, Ruud W. , Gelfman, Russell , Amadio, Peter C.

Mayo Clinic

Arthritis Care & Research | October 7, 2016 | Volume: 69 | Issue: 7 | Pages: 1060-1065

10.1002/acr.23108 | PMID 27696773 Get It

ObjectiveTo compare the effectiveness of ultrasound‐guided injections to blind injections in the treatment of carpal tunnel syndrome (CTS) in a large community‐based cohort.MethodsThis study evaluated residents of Olmsted County, Minnesota, treated with a corticosteroid injection for CTS between 2001 and 2010. The proportion of patients receiving retreatment and the duration of retreatment‐free survival between blind and ultrasound‐guided injections were compared. Propensity score matching was used to control for confounding by indication.ResultsIn the matched data set consisting of 234 (of 600) hands treated with a blind injection and 87 (of 89) ultrasound‐guided injection cases, ultrasound guidance was associated with a reduced hazard of retreatment (hazard ratio 0.59 [95% confidence interval (95% CI) 0.37–0.93]). In addition, ultrasound guidance was associated with 55% reduced odds of retreatment within 1 year compared to blind injections (adjusted odds ratio 0.45 [95% CI 0.24–0.83]).ConclusionThis study indicates that ultrasound‐guided injections are more effective in comparison to blind injections in the treatment of CTS.
Dissemination and Implementation of Shared Decision Making Into Clinical Practice: A Research Agenda
Kanzaria, Hemal K., Booker‐Vaughns, Juanita , Itakura, K, Yadav, Kabir , Kane, Bryan G , Gayer, Christopher, Lin, Grace A. , Gibson, Robert W. , Williams, Pluscedia, Carpenter, Christopher R. , LeBlanc, Annie , Chen, Esther H. , Carpenter, Christopher R

Mayo Clinic

Academic Emergency Medicine | August 26, 2016 | Volume: 23 | Issue: 12 | Pages: 1368-1379

10.1111/acem.13075 | PMID 27561951 Get It

AbstractShared decision making (SDM) is essential to advancing patient‐centered care in emergency medicine. Despite many documented benefits of SDM, prior research has demonstrated persistently low levels of patient engagement by clinicians across many disciplines, including emergency medicine. An effective dissemination and implementation (D&I) framework could be used to alter the process of delivering care and to facilitate SDM in routine clinical emergency medicine practice. Here we outline a research and policy agenda to support the D&I strategy needed to integrate SDM into emergency care.