INTRODUCTION: Over-the-scope clips (OTSC) are used for closure of fistulas, leaks, and acute perforations, and for GI bleeding. Adverse events include perforation, migration, and ulceration. Little is know about the natural history of OTSCs and no data addressing the longevity of clips is available. We present an interim analysis of our center’s experience with OTSC focusing on natural history. METHODS: OTSCs used from 1/1/2011 to 1/1/2019 were compiled and retrospective chart review undertaken. Primary endpoint was clip retention time (time when the clip was placed to time the clip was last seen or was physically removed). Secondary endpoints were rate of complications and factors that influence clip retention time and clinical success. Cox proportional hazards were used to evaluate variables impacting clip retention. Univariate regression was used to assess potential risk factors for adverse events. RESULTS: A total of 358 OTSC were placed in 299 patients (55.8% male, n = 184) with mean age 64 + 15.3 years. Procedures and indications presented in Table 1. Clip placement was clinically successful in 81% of cases (N = 265). Median time to clip loss as assessed by Kaplan-Meier curve was 267 days (95% CI 196-406) (Figure 1). Adverse events occurred in 34 clip placements (10.7%) and included bleeding (n = 8, 24.2%), perforation (n = 5, 15.2%), ulceration (n = 3, 9.1%), migration (n = 15, 45.5%), and infection (n = 1, 3.0%). Univariate analysis (Table 2) revealed that age, gender, type of clip used (there are 3 types of OTSC), and performing endoscopist did not impact clip retention rate. A size 14 clip had marginally higher rates of retention compared to others. Clips placed in the rectum or esophagus were lost earlier compared to those in the small/large intestine and stomach. Clips placed for fistulas and those associated with adverse event were associated with earlier clip loss. In evaluation of clinical success, clips placed for fistulas had a relative risk of clinical failure of 2.08 (95% CI 1.29-3.36) compared to all other indications. CONCLUSION: OTSCs are retained for a median of 8.9 months with clip location and indication for placement being key factors in time to clip loss. Clips used for fistula closure were more likely to be lost compared to those placed for other indications, less likely to be clinically successful, and more likely to cause a complication. These data help guide decision-making when considering OTSC use across clinical indications.
Esophageal overtubes provide no benefit to safety or technical success in upper gastrointestinal tract endoscopic suturing
Abstract Background and study aim The role of esophageal overtubes in upper gastrointestinal endoscopic suturing is unknown. This study aimed to determine whether overtube use was associated with technical success or adverse events. Patients and methods A retrospective review of consecutive patients who underwent endoscopic suturing for various indications was performed. Results A total of 719 patients underwent endoscopic suturing for various indications, including endoscopic bariatric procedures in 262, stent fixation in 258, defect closure in 190, and hemostasis in nine. An overtube was used in 186 procedures (25.9 %). Technical success was achieved in all cases. Minor mucosal trauma occurred in 15 cases (8.1 %) with use of an overtube, and none without an overtube (P < 0.0001). No full-thickness esophageal perforation or hemorrhage related to overtube use or the suturing device occurred. Conclusions Endoscopic suturing can be performed safely for a variety of indications, including endoscopic bariatric procedures, defect repair, and stent fixation without an esophageal overtube. Minor esophageal mucosal trauma and equipment cost are increased when an overtube is used.
Accelerated gastric emptying is associated with improved aspiration efficiency in obesity
Background The overall effectiveness of aspiration therapy (AT) for obesity relies on optimal aspiration timing after a meal, which can vary depending on a patient’s rate of gastric emptying (GE). Our aim was to identify if baseline GE rates were associated with differences in aspiration efficiency (AE). Methods Subjects from an ongoing AT clinical trial were enrolled in this study. AE was calculated as the absolute gastric residual and calories aspirated at 20 and 40 min. Participants were then divided by baseline GE rate into two groups (slow vs fast). Wilcoxon rank-sum test was used to compare AE at 20 and 40 min between the groups. Exploratory linear regression was used to assess relationship between GE and AE. Results 7 patients (85% female) were coenrolled in the study. Mean age and body mass index were 39.8±9.44 and 43±5, respectively. AE did not significantly differ between the 20 and 40 min time points for the group as a whole (34.3% vs 36.9%; p>0.5). However, those with fast GE aspirated more calories than those with slow GE (20 min: 200 kcal vs 72.5 kcal; 40 min: 154 kcal vs 63 kcal) (p=0.05). On linear regression, delayed GE was associated with poorer aspiration (20 min: β=−107 calories; p=0.019; R2=0.7). 4/7 patients had significant differences in residual/caloric aspiration across the two time points. Conclusion Patients undergoing AT may benefit from a GE test to optimise their AE. Paradoxically faster GE times saw better aspiration. Prospective studies are revealing a personalised approach to obesity.
Knowledge of endoscopic ultrasound-delivered fiducial composition and dimension necessary when planning proton beam radiotherapy
Abstract Background and study aims Little consideration has been given to selection of endoscopic ultrasound-guided fiducials for proton radiotherapy and the resulting perturbations in the therapy dose and pattern. Our aim was to assess the impact of perturbations caused by six fiducials of different composition and dimensions in a phantom gel model. Materials and methods The phantom was submerged in a water bath and irradiated with a uniform 10 cm × 10 cm field of 119.7 MeV monoenergetic spot scanning protons delivered through a 45 mm range shifter. The proton “Bragg Peak” was evaluated. Results Dose perturbations manifesting as dose reductions up to 30 % were observed. A carbon composite (1 × 5 mm) and gold (0.4 × 10 mm) fiducial with backload potential rather than dedicated EUS pre-loaded gold fiducial needles had the best performance in terms of minimizing the dose perturbation. Conclusions Our data demonstrate that a carbon composite fiducial has a less untoward effect on proton therapy dose distribution than dedicated EUS pre-loaded gold fiducial needles. Such information is important to consider when selecting fiducials specifically for proton therapy.
Long-term successful closure of a percutaneous intragastric trocar tract with crossing full-thickness sutures in a porcine model
Abstract Background and study aims A novel intragastric trocar placed using a percutaneous endoscopic gastrostomy technique enables the use of laparoscopic tools and procedures, including tissue stapling, cutting, suturing, and retraction. The aim of this porcine study was to determine long-term success of crossing full-thickness sutures in closure of the tract upon trocar withdrawal. Methods 10 trocars were placed in 5 animals. Each animal underwent a standardized tissue resection using a 5-mm stapler under gastroscopic guidance, and two full-thickness, absorbable, crossing sutures were used to close the trocar tracts. The animals were monitored for 35 days and then euthanized for necropsy. Results All five animals survived without sign of infection or distress. Nine of the 10 trocar sites healed completely without any adverse findings. A single site developed a gastrocutaneous fistula. On necropsy, there was no evidence of intra-abdominal infection or abscess. Conclusions Full-thickness crossing sutures appeared to be effective in long-term closure of an intragastric trocar tract. Given the ease of placement and success of this simple closure method, this device may prove clinically useful to the endoscopist performing complex procedures in the endoscopy suite.