Citations

Clear

159 citation(s) found for "Srinivasan, V".

Abstract 10986: SGK1 Inhibition Attenuated the Action Potential Duration In-Patient and Genotype-Specific Re-Engineered Heart Cells With Congenital Long QT Syndrome
Tester, David J. , Pradhananga, Sabindra , Srinivasan, Dinesh , Sager, Philip T. , Ackerman, Michael J. , Das, Saumya , Kim, Maengjo , Hamrick, Samantha K.

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10986 Get It

Background: Long QT syndrome (LQTS) often stems from pathogenic variants in KCNQ1 (LQT1), KCNH2 (LQT2), or SCN5A (LQT3) and is characterized cellularly by prolongation of the cardiac action potential duration (APD). We have shown that inhibition of serum and glucocorticoid regulated kinase-1 (SGK1) reduces I NaL and is proposed as a novel therapeutic strategy for LQT3. Objective: To test the efficacy of a potent and selective SGK1 inhibitor (SGK1-I) in human cardiomyocyte models of LQT1, LQT2, and LQT3. Methods: Induced pluripotent stem cell derived cardiomyocytes (iPSC-CMs) were generated from patients with either LQT1, LQT2, or LQT3. The mexiletine (MEX)-sensitive SCN5A-P1332L iPSC-CMs were tested initially. A CRISPR/Cas9 P1332L variant-corrected isogenic control (IC) was used as a control. The SGK1-I’s therapeutic efficacy was compared to MEX and to a commercially available SGK1 inhibitor (EMD638683). The novel SGK-I was then tested for APD shortening in SCN5A-R1623Q, KCNH2-G604S and KCNQ1-V254M iPSC-CMs. The APD90 values were recorded 4 hours after treatment using FluoVolt. Results: The APD90 was significantly prolonged in SCN5A-P1332L iPSC-CMs compared to its IC (646 ± 7 ms vs 482 ± 23 ms, p<0.0001). MEX shortened the average APD90 to 560 ± 7 ms (52% attenuation). Interestingly, SGK1-I significantly shortened the APD to 518 ± 5 ms (78% attenuation) but did not further shorten the APD in the IC. SGK1-I also shortened the APD90 of the SCN5A-R1623Q iPSC-CMs from 753 ± 8 ms to 475 ± 19 ms compared to 558 ± 19 ms with MEX. The SGK1-I shortened the APD90 in KCNH2-G604S (666 ± 10ms to 574 ± 18ms for SGK1-I versus 538 ± 15 ms after MEX). EMD had limited APD shortening effects in SCN5A and KCNH2 iPSC-CMs. Interestingly, while neither MEX nor EMD reduced the APD90 in the KCNQ1-V254M iPSC-CMs, the novel SGK1-I reduced the APD90 from 544 ± 10 ms to 475 ± 11ms (p=0.0004). Conclusions: Therapeutically inhibiting SGK1 effectively shortens the cardiomyocyte APD in human heart cell models of the 3 major LQTS genotypes. The novel SGK1-I normalized the pathological APD prolongation almost fully (> 70%) in the patient-derived SCN5A-P1332L iPSC-CM model. These pre-clinical data support further development of SGK1-I as a novel, first-in-class therapy for patients with congenital LQTS.
Assessment of the Inter-observer Variability of the Radiomic Tools: BRODERS (Benign vs aggressive nODule Evaluation using Radiomic Stratification) and SILA (Score Indicative of Lung cancer Aggression) to Classify Lung Nodules
Al-Ghoula, Faysal, FALDE, SAMUEL D, Rajagopalan, Srinivasan, Maldonado, Fabien , Peikert, Tobias, Bartholmai, Brian J. , Bartholmai, Brian J , Patel, Khushbu

Mayo Clinic

No container title available | May 24, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-2884203/v1 Get It

Abstract Introduction: While CT lung cancer screening reduces lung cancer-specific mortality, there are remaining challenges. Radiomic tools promiss to address these challenges, however, they are subject to interobserver variability if semi-automated segmentation techniques are used. Herein we report interobserver variability for two validated radiomic tools, BRODERS (Benign versus aggRessive nODule Evaluation using Radiomic Stratification) and CANARY (Computer-Aided Nodule Assessment and Risk Yield). Methods We retrospectively analyzed the CT images of 95 malignant lung nodules of the adenocarcinoma spectrum using BRODERS and CANARY. Cases were identified at Mayo Clinic (n = 45) and Vanderbilt University Medical Center and Nashville/Veteran Administration Tennessee Valley Health Care System (n = 50). Three observers with different training levels (medical student, internal medicine resident and thoracic radiology fellow) each performed lung nodule segmentation. All methods were carried out in accordance with relevant guidelines and regulations Results Interclass correlation coefficients (ICC) of 0.77, 0.98 and 0.97 for the average nodule volume, BRODERS cancer probability and Score Indicative of Lesion Aggression (SILA) which summarizes the distribution of the CANARY exemplars indicated good to excellent reliability, respectively. The dice similarity coefficient was 0.79 and 0.81 for the data sets from the two institutions. Conclusion: BRODERS and CANARY are robust radiomics tools with excellent interobserver variability. These tools are simple and reliable regardless the observer/operator’s level of training.
Implications and future directions of ChatGPT utilization in neurosurgery
Reardon, Taylor , Srinivasan, Visish M. , Gottfried, Oren N., Bydon, Mohamad , Lawton, Michael T. , Singh, Rohin

Mayo Clinic

Journal of Neurosurgery | April 29, 2023 | Volume: 139 | Issue: 5 | Pages: 1487-1489

10.3171/2023.3.jns23555 | PMID 37119117 Get It

Abstract Number ‐ 202: Multispecialty Involvement in Neuroendovascular Interventions
Stonnington, Henry O. , Srinivasan, Visish M. , Brown, Nolan J. , Steiger, Kyle , Singh, Rohin , Shahrestani, Shane , Catapano, Joshua S , Gendreau, Julian , Patel, Naresh P. , Erben, Young

Mayo Clinic

Stroke: Vascular and Interventional Neurology | April 25, 2023 | Volume: 3 | Issue: S1 | Pages: No page available

10.1161/svin.03.suppl_1.202 Get It

Introduction While neurovascular surgeries have largely been performed by neurosurgeons, the advent of endovascular procedures has produced increasing involvement of other specialists in this arena (i.e. neurologists and radiologists).This study aims to analyzethe involvement of different specialties within theneuroendovascular workforce by characterizingthem by their primary specialty. Methods The Medicare Provider Utilization Database was queried from 2013 to 2019 for all primary Current Procedural Terminology (CPT) codes identified by the American Medical Association as pertaining to endovascular procedures of the nervous system (61623, 61624, 61630, 61635, 61626, 61645, and 61650). We counted the number of unique providers in respective fields (neurology, neurosurgery, and radiology) who performed these procedures. Statistical analyses, including data aggregation, exploratory analysis, and propensity adjustment, were performed using R, version 4.0.1 (The R Foundation, Vienna, Austria). The two‐sided Mann‐Kendall trend test, a non‐parametric statistical test that assesses for monotonic trends in either an upward or downward trend, was utilized to assess for trends over time. Within each year analyzed, a Chi‐squared test for trend in proportions was used. A significance level of 0.05 was used. Results In 2013, neurosurgeons comprised 45% of the workforce performing these procedures, neurologists were 9%, and radiologists were 47%. By 2019, neurosurgeons decreased to 34.5% of the workforce, while neurologists increased to 21.5%, and radiologists decreased slightly to 44%. Neurologists were the only field in which the proportional shift in providers was noted to have a significant change in trajectory (p:0.04), an upward trajectory. Overall proportional differences between respective specialists were statistically significant each year (p< 0.01). Conclusions Neurologists are increasingly performing endovascular procedures. Increased communication and coordination between specialties can improve disparities in care to ensure adequate access to neurovascular care across the US.
Abstract Number ‐ 201: Increased Utilization of Neuro‐Endovascular Procedures: 2013–2019
Stonnington, Henry O. , Srinivasan, Visish M. , Brown, Nolan J. , Steiger, Kyle , Singh, Rohin , Koester, Stefan Wolfgang , Shahrestani, Shane , Catapano, Joshua S , Gendreau, Julian , Patel, Naresh P. , Erben, Young

Mayo Clinic

Stroke: Vascular and Interventional Neurology | April 25, 2023 | Volume: 3 | Issue: S1 | Pages: No page available

10.1161/svin.03.suppl_1.201 Get It

Introduction Endovascular procedures have become increasingly popular in recent years due to preference of minimally invasive approaches and technological advancement.This study aims to characterize the trends in procedural rates of common neuro‐endovascular procedures performed by neurologists, neurosurgeons, and radiologists. Methods The Medicare Provider Utilization Database was queried from 2013 to 2019 for all primary Current Procedural Terminology codes identified by the American Medical Association as pertaining to endovascular procedures of the nervous system (61623, 61624, 61630, 61635, 61626, 61645, and 61650). Statistical analyses, including data aggregation, exploratory analysis, and propensity adjustment, were performed using R, version 4.0.1 (The R Foundation, Vienna, Austria). The two‐sided Mann‐Kendall trend test, a non‐parametric statistical test that assesses for monotonic trends in either an upward or downward trend, was utilized to assess for trends over time. A significance level of 0.05 was used. Results Between 2013 to 2019 a total of 40,730 endovascular procedures were performed by neurosurgeons, neurologists and radiologists treating Medicare patients. When all codes were combined, there was a significant increase in the number of procedures done by all specialists: Radiology (2013:1080; 2019:4938; p:0.02), Neurosurgery (2013:1230; 2019:4508; p< 0.01), and Neurology (2013:205; 2019:2397; p:0.04). Significant increases in mechanical thrombectomy (CPT61645) were observed in all fields: Radiology (2016:1287, 2019:3542; p< 0.01), Neurosurgery (2016:610; 2019:2326; p< 0.01), Neurology (2016:569; 2019:1951; p< 0.01). Increases in transcatheter permanent occlusion (CPT61624) were observed in neurosurgery (2013:1230; 2019:2049; p:0.04). Increases in temporary balloon artery occlusion (CPT61623) were noted in neurology (2013:21; 2019:27; p:0.04). Conclusions Endovascular procedures have seen a dramatic rise in utilization over a short amount of time, particularly mechanical thrombectomy. Future investigation should include more inclusive datasets beyond the Medicare population.
Hemostatic In Vitro Properties of Novel Plasma Supernatants Produced from Late-storage Low-titer Type O Whole Blood
Mihalko, Emily , Rahn, Katelin, Seheult, Jansen N. , Cap, Andrew P., Triulzi, Darrell J., Yazer, Mark H. , Shea, Susan M. , Mihalko, Emily P , Shea, Susan M , Seheult, Jansen N , Srinivasan, Amudan J. , Spinella, Philip C. , Cap, Andrew P., Neal, Matthew D

Mayo Clinic

Anesthesiology | April 7, 2023 | Volume: 139 | Issue: 1 | Pages: 77-90

10.1097/aln.0000000000004574 | PMID 37027803 Get It

Background The use of low-titer group O whole blood is increasing. To reduce wastage, unused units can be converted to packed red blood cells. Supernatant is currently discarded post-conversion; however, it could be a valuable transfusable product. The aim of this study was to evaluate supernatant prepared from late-storage low-titer group O whole blood being converted to red blood cells, hypothesizing it will have higher hemostatic activity compared to fresh never-frozen liquid plasma. Methods Low-titer group O whole blood supernatant (n = 12) prepared on storage day 15 was tested on days 15, 21, and 26 and liquid plasma (n = 12) on 3, 15, 21, and 26. Same-day assays included cell counts, rotational thromboelastometry, and thrombin generation. Centrifuged plasma from units was banked for microparticle characterization, conventional coagulation, clot structure, hemoglobin, and additional thrombin generation assays. Results Low-titer group O whole blood supernatant contained more residual platelets and microparticles compared to liquid plasma. At day 15, low-titer group O whole blood supernatant elicited a faster intrinsic clotting time compared to liquid plasma (257 ± 41 vs . 299 ± 36 s, P = 0.044), and increased clot firmness (49 ± 9 vs . 28 ± 5 mm, P < 0.0001). Low-titer group O whole blood supernatant showed more significant thrombin generation compared to liquid plasma (day 15 endogenous thrombin potential 1,071 ± 315 vs . 285 ± 221 nM·min, P < 0.0001). Flow cytometry demonstrated low-titer group O whole blood supernatant contained significantly more phosphatidylserine and CD41 + microparticles. However, thrombin generation in isolated plasma suggested residual platelets in low-titer group O whole blood supernatant were a greater contributor than microparticles. Additionally, low-titer group O whole blood supernatant and liquid plasma showed no difference in clot structure, despite higher CD61 + microparticle presence. Conclusions Plasma supernatant produced from late-storage low-titer group O whole blood shows comparable, if not enhanced, in vitro hemostatic efficacy to liquid plasma. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
3D Modeling for Approach Selection Pedagogy in Complex Cranial Surgery: Skull Basics Overview and Proof-of-Concept Results
Nguyen, Bachtri T. , Srinivasan, Visish M. , Holroyd, Michael J., Perry, Avital , Peris‐Celda, Maria , Link, Michael J., Graffeo, Christopher S. , Morris, Jonathan M. , Holroyd, Michael J., Carlstrom, Lucas P. , Link, Michael J.

Mayo Clinic

Journal of Neurological Surgery Part B: Skull Base | March 20, 2023 | Volume: 84 | Issue: S 01 | Pages: S1-S344

10.1055/s-0043-1762111 Get It

A 3D Printed, Multicolor, Drillable Simulation System for Skull Base Drilling with Direct, Objective Real-Time Feedback
Nguyen, Bachtri T. , Srinivasan, Visish M. , Holroyd, Michael J., Perry, Avital , Peris‐Celda, Maria , Link, Michael J., Graffeo, Christopher S. , Morris, Jonathan M. , Holroyd, Michael J., Carlstrom, Lucas P. , Link, Michael J.

Mayo Clinic

Journal of Neurological Surgery Part B: Skull Base | March 20, 2023 | Volume: 84 | Issue: S 01 | Pages: S1-S344

10.1055/s-0043-1762015 Get It

A Comprehensive Review on AI-Enabled Models for Parkinson’s Disease Diagnosis
Dixit, Shriniket, Bohre, Khitij, Singh, Yashbir , Himeur, Yassine , Mansoor, Wathiq , Atalla, Shadi , Srinivasan, Kathiravan , Singh, Yashbir

Mayo Clinic

Electronics | February 6, 2023 | Volume: 12 | Issue: 4 | Pages: 783

10.3390/electronics12040783 Get It

Parkinson’s disease (PD) is a devastating neurological disease that cannot be identified with traditional plasma experiments, necessitating the development of a faster, less expensive diagnostic instrument. Due to the difficulty of quantifying PD in the past, doctors have tended to focus on some signs while ignoring others, primarily relying on an intuitive assessment scale because of the disease’s characteristics, which include loss of motor control and speech that can be utilized to detect and diagnose this disease. It is an illness that impacts both motion and non-motion functions. It takes years to develop and has a wide range of clinical symptoms and prognoses. Parkinson’s patients commonly display non-motor symptoms such as sleep problems, neurocognitive ailments, and cognitive impairment long before the diagnosis, even though scientists have been working to develop designs for diagnosing and categorizing the disease, only noticeable defects such as movement patterns, speech, or writing skills are offered in this paper. This article provides a thorough analysis of several AI-based ML and DL techniques used to diagnose PD and their influence on developing additional research directions. It follows the guidelines of Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). This review also examines the current state of PD diagnosis and the potential applications of data-driven AI technology. It ends with a discussion of future developments, which aids in filling critical gaps in the current Parkinson’s study.
Outcomes after liver transplantation using deceased after circulatory death donors: A comparison of outcomes in the UK and the US
Ivanics, Tommy , Claasen, Marco P. A. W. , Patel, Madhukar S. , Giorgakis, Emmanouil , Khorsandi, Shirin Elizabeth , Srinivasan, Parthi , Prachalias, Andreas , Menon, Krishna , Jassem, Wayel , Cerisuelo, Miriam Cortés , Mathur, Amit K. , Walker, Kate , Taylor, Rhiannon , Heaton, Nigel , Mehta, Neil , Segev, Dorry L. , Massie, Allan B. , Meulen, Jan van der , Wallace, David , Khorsandi, Shirin E , Cortes, Miriam , Sayed, Blayne A , Mathur, Amit , Walker, Kate , Taylor, Rhiannon , Heaton, Nigel , Mehta, Neil , Segev, Dorry L , Massie, Allan B , van der Meulen, Jan H P , Sapisochin, Gonzalo , Ivanics, Tommy , Giorgakis, Emmanouil , Sayed, Blayne A. , Sapisochín, Gonzalo , Patel, Madhukar

Mayo Clinic

Liver International | February 4, 2023 | Volume: 43 | Issue: 5 | Pages: 1107-1119

10.1111/liv.15537 | PMID 36737866 Get It

AbstractBackground and AimsIdentifying international differences in utilization and outcomes of liver transplantation (LT) after donation after circulatory death (DCD) donation provides a unique opportunity for benchmarking and population‐level insight.MethodsAdult (≥18 years) LT data between 2008 and 2018 from the UK and US were used to assess mortality and graft failure after DCD LT. We used time‐dependent Cox‐regression methods to estimate hazard ratios (HR) for risk‐adjusted short‐term (0–90 days) and longer‐term (90 days–5 years) outcomes.ResultsOne‐thousand five‐hundred‐and‐sixty LT receipts from the UK and 3426 from the US were included. Over the study period, the use of DCD livers increased from 15.7% to 23.9% in the UK compared to 5.1% to 7.6% in the US. In the UK, DCD donors were older (UK:51 vs. US:33 years) with longer cold ischaemia time (UK: 437 vs. US: 333 min). Recipients in the US had higher Model for End‐stage Liver Disease (MELD) scores, higher body mass index, higher proportions of ascites, encephalopathy, diabetes and previous abdominal surgeries. No difference in the risk‐adjusted short‐term mortality or graft failure was observed between the countries. In the longer‐term (90 days–5 years), the UK had lower mortality and graft failure (adj.mortality HR:UK: 0.63 (95% CI: 0.49–0.80); graft failure HR: UK: 0.72, 95% CI: 0.58–0.91). The cumulative incidence of retransplantation was higher in the UK (5 years: UK: 11.9% vs. 4.6%; p < .001).ConclusionsFor those receiving a DCD LT, longer‐term post‐transplant outcomes in the UK are superior to the US, however, significant differences in recipient illness, graft quality and access to retransplantation were seen between the two countries.