Citations

Clear

162 citation(s) found for "Fletcher, Joel G".

Deep-learning-based direct synthesis of low-energy virtual monoenergetic images with multi-energy CT
Gong, Hao , Marsh, Jeffrey F., DSouza, Karen N. , Huber, Nathan R. , D'Souza, Karen N , Rajendran, Kishore , McCollough, Cynthia H , Leng, Shuai , Rajendran, Kishore , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Journal of Medical Imaging | April 19, 2021 | Volume: 8 | Issue: 05 | Pages: No page available

10.1117/1.jmi.8.5.052104 | PMID 33889658 Get It

The feasibility of low iodine dynamic CT angiography with test bolus for evaluation of lower extremity peripheral artery disease
Inoue, Akitoshi , Vrtiska, Terri J., Lee, Yong S. , Vasconcelos, Rogerio N., Weber, Nikkole M. , Halaweish, Ahmed F., Duba, Irene , Williamson, Eric E. , Fletcher, Joel G , Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Mayo Clinic

Vascular | January 18, 2021 | Volume: 29 | Issue: 6 | Pages: 927-937

10.1177/1708538120986304 | PMID 33459205 Get It

Objective This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. Methods After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into “not opacified”, “<50% stenosis”, “ 50 ̶70% stenosis”, “>70% stenosis”, and “occluded” for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. Results Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8–32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively ( p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus ( p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) ( p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients ( p = 0.319), respectively. Conclusion Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.
Low‐dose CT image and projection dataset
Moen, Taylor R., Chen, Baiyu , Holmes, David R. , Yu, Zhicong , Yu, Lifeng , Duan, Xinhui , Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Mayo Clinic

Medical Physics | November 17, 2020 | Volume: 48 | Issue: 2 | Pages: 902-911

10.1002/mp.14594 | PMID 33202055 Get It

Purpose To describe a large, publicly available dataset comprising computed tomography (CT) projection data from patient exams, both at routine clinical doses and simulated lower doses. Acquisition and Validation Methods The library was developed under local ethics committee approval. Projection and image data from 299 clinically performed patient CT exams were archived for three types of clinical exams: noncontrast head CT scans acquired for acute cognitive or motor deficit, low‐dose noncontrast chest scans acquired to screen high‐risk patients for pulmonary nodules, and contrast‐enhanced CT scans of the abdomen acquired to look for metastatic liver lesions. Scans were performed on CT systems from two different CT manufacturers using routine clinical protocols. Projection data were validated by reconstructing the data using several different reconstruction algorithms and through use of the data in the 2016 Low Dose CT Grand Challenge. Reduced dose projection data were simulated for each scan using a validated noise‐insertion method. Radiologists marked location and diagnosis for detected pathologies. Reference truth was obtained from the patient medical record, either from histology or subsequent imaging. Data Format and Usage Notes Projection datasets were converted into the previously developed DICOM‐CT‐PD format, which is an extended DICOM format created to store CT projections and acquisition geometry in a nonproprietary format. Image data are stored in the standard DICOM image format and clinical data in a spreadsheet. Materials are provided to help investigators use the DICOM‐CT‐PD files, including a dictionary file, data reader, and user manual. The library is publicly available from The Cancer Imaging Archive ( https://doi.org/10.7937/9npb‐2637 ). Potential Applications This CT data library will facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence. The provided clinical information allows evaluation of task‐based diagnostic performance.
S1219 Prediction of Surgical Intervention for Crohn’s Perianal Fistula in Children: Predictive Patient Demographic and Anatomic Features by MRI
Khan, Muhammad Rehan , Hull, Nathan C. , Ulrich, Jessica A., Harmsen, William S. , Faubion, William A. , Absah, Imad , Inoue, Akitoshi , Fletcher, Joel G.

Mayo Clinic

American Journal of Gastroenterology | October 24, 2020 | Volume: 115 | Issue: 1 | Pages: S610-S611

10.14309/01.ajg.0000706924.57387.45 Get It

Triple‐Phase Computed Tomography May Replace Dual‐Energy X‐ray Absorptiometry Scan for Evaluation of Osteoporosis in Liver Transplant Candidates
Izzy, Manhal , Addissie, Benyam D., Arab, Juan Pablo , Hilscher, Moira , Cartee, Amanda K. , Lee, David C. , Keaveny, Tony M. , Sánchez, William , Hilscher, Moira B, Lee, Yong, Arab, Juan P , Sanchez, William , Lee, Yong Yi , Fletcher, Joel G.

Mayo Clinic

Liver Transplantation | October 23, 2020 | Volume: 27 | Issue: 3 | Pages: 341-348

10.1002/lt.25926 | PMID 33098253 Get It

Assessment of bone density is an important part of liver transplantation (LT) evaluation for early identification and treatment of osteoporosis. Dual‐energy X‐ray absorptiometry (DXA) is currently the standard clinical test for osteoporosis; however, it may contribute to the appointment burden on LT candidates during the cumbersome evaluation process, and there are limitations affecting its accuracy. In this study, we evaluate the utility of biomechanical analysis of vertebral images obtained during dual‐energy abdominal triple‐phase computed tomography (TPCT) in diagnosing osteoporosis among LT candidates. We retrospectively reviewed cases evaluated for LT between January 2017 and March 2018. All patients who underwent TPCT within 3 months of DXA were included. The biomechanical computed tomography (BCT) analysis was performed at a centralized laboratory (O.N. Diagnostics, Berkeley, CA) by 2 trained analysts blinded to the DXA data. DXA‐based osteoporosis was defined as a T score ≤−2.5 at the hip or spine. BCT‐based osteoporosis was defined as vertebral strength ≤4500 N for women or ≤6500 N for men or trabecular volumetric bone mineral density ≤80 mg/cm3. Comparative data were available for 91 patients who had complete data for both DXA and BCT: 31 women and 60 men, age 54 ± 11 years (mean ± standard deviation), mean body mass index 28 ± 6 kg/m2. Using DXA as the clinical reference, sensitivity of BCT to detect DXA‐defined osteoporosis was 83.3% (20/24 patients) and negative predictive value was 91.7%; specificity and positive predictive value were 65.7% and 46.5%, respectively. BCT analysis of vertebral images on triple‐phase computed tomography, routinely obtained during transplant evaluation, can reliably rule out osteoporosis in LT candidates. Patients with suspicion of osteoporosis on TPCT may need further evaluation by DXA.
Deep-learning-based model observer for a lung nodule detection task in computed tomography
Gong, Hao , Hu, Qiyuan , Walther, Andrew , Koo, Chi Wan , Levin, David L. , Johnson, Tucker F. , Hora, Megan J., Yu, Lifeng , Takahashi, Edwin A. , Leng, Shuai , McCollough, Cynthia H , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Mayo Clinic

Journal of Medical Imaging | June 30, 2020 | Volume: 7 | Issue: 04 | Pages: 1

10.1117/1.jmi.7.4.042807 | PMID 32647740 Get It

Panenteric capsule endoscopy versus ileocolonoscopy plus magnetic resonance enterography in Crohn’s disease: a multicentre, prospective study
Bruining, David H. , Fleisher, Mark R., Fischer, Monika , Bruining, David Henry , Oliva, Salvatore , Fletcher, Joel G.

Mayo Clinic

BMJ Open Gastroenterology | June 4, 2020 | Volume: 7 | Issue: 1 | Pages: e000365

10.1136/bmjgast-2019-000365 | PMID 32499275 Get It

Introduction Crohn’s disease diagnosis and monitoring remains a great clinical challenge and often requires multiple testing modalities. Assessing Crohn’s disease activity in the entire gastrointestinal (GI) tract using a panenteric capsule endoscopy (CE) system could be used as an alternative to colonoscopy and cross-sectional imaging. This study assessed the accuracy and safety of panenteric CE in Crohn’s disease as compared with ileocolonoscopy (IC) and/or magnetic resonance enterography (MRE). Methods A prospective, multicentre study was performed in subjects with established Crohn’s disease. Individuals with proven small bowel patency underwent a standardised bowel preparation, followed by CE ingestion and IC either the same or following day. MRE, IC, and CE interpretations were performed by blinded central readers using validated scoring systems. The primary endpoint was the overall sensitivity of CE vs MRE and/or IC in Crohn’s disease subjects. Results Study enrolment included 158 subjects from 21 sites in the USA, Austria, and Israel. Of those, 99 were included in the analysis. Imaging modality scores indicated none to mild inflammation in the proximal small bowel and colon, but discrepant levels of inflammation in the terminal ileum. Overall sensitivity for active enteric inflammation (CE vs MRE and/or IC) was 94% vs 100% (p=0.125) and specificity was 74% vs 22% (p=0.001). Sensitivity of CE was superior to MRE for enteric inflammation in the proximal small bowel (97% vs 71%, p=0.021), and similar to MRE and/or IC in the terminal ileum and colon (p=0.500–0.625). There were seven serious adverse advents of which three were related to the CE device. Conclusion Panenteric CE is a reliable tool for assessing Crohn’s disease mucosal activity and extent compared with more invasive methods. This study demonstrates high performance of the panenteric CE as compared to MRE and/or IC without the need for multiple tests in non-stricturing Crohn’s disease. Trial registration number ClinicalTrials.gov NCT03241368
Image quality in abdominal CT using an iodine contrast reduction algorithm employing patient size and weight and low kV CT technique
Iyer, Veena R. , Ehman, Eric C. , Khandelwal, Ashish , Wells, Michael , Lee, Yong S. , Weber, Nikkole M. , Johnson, Matthew P. , Yu, Lifeng , Fletcher, Joel G. , Wells, Michael L, Fletcher, Joel G , Yu, Lifeng , McCollough, Cynthia H.

Mayo Clinic

Acta Radiologica | January 27, 2020 | Volume: 61 | Issue: 9 | Pages: 1186-1195

10.1177/0284185119898655 | PMID 31986894 Get It

Background Low tube potential-high tube current computed tomography (CT) imaging allows reduction in iodine-based contrast dose and may extend the benefit of routine contrast-enhanced CT exams to patients at risk of nephrotoxicity. Purpose To determine the ability of an iodine contrast reduction algorithm to maintain diagnostic image quality for contrast-enhanced abdominal CT. Material and Methods CT exams with iodine contrast reduction were prescribed for patients at risk for renal dysfunction. The iodine contrast reduction algorithm combines weight-based contrast volume reduction with patient width-based low tube potential selection and bolus-tracking. Control exams with routine iodine dose were selected based on weight, width, and scan protocol. Three radiologists evaluated image quality and diagnostic confidence using a 4-point scale (<2 acceptable). Another radiologist assessed contrast reduction indications and measured portal vein and liver contrast-to-noise ratios. Results Forty-six contrast reduction algorithm and control exams were compared (mean creatinine 1.6 vs. 1.2 mg/dL, P ≤ 0.0001). Thirty-nine contrast reduction patients had an eGFR <60 mL/min/1.73m 2 and 15 had single or transplanted kidney. Mean iodine contrast dose was lower in the contrast reduction group (20.9 vs. 39.4 g/mL, P < 0.0001). Diagnostic confidence was rated as acceptable in 95% (131/138) of contrast reduction and 100% of control exams (1.18–1.28 vs. 1.02–1.13, respectively; P > 0.06). Liver attenuation and contrast-to-noise ratio (CNR) were similar ( P = 0.08), but portal vein attenuation and CNR were lower with contrast-reduction (mean 176 vs. 198 HU, P = 0.02; 13 vs. 16, P = 0.0002). Conclusion This size-based contrast reduction algorithm using low kV and bolus tracking reduced iodine contrast dose by 50%, while achieving acceptable image quality in 95% of exams.
Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter
Voß, Benjamin, Tao, Shengzhen , Lane, John I. , Weaver, Jayse , Carlson, Matthew L. , Rajendran, Kishore , Zhou, Wei , DeLone, David R. , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Investigative Radiology | November 26, 2019 | Volume: 55 | Issue: 2 | Pages: 91-100

10.1097/rli.0000000000000614 | PMID 31770297 Get It

Objective The aim of this study was to quantitatively demonstrate radiation dose reduction for sinus and temporal bone examinations using high-resolution photon-counting detector (PCD) computed tomography (CT) with an additional tin (Sn) filter. Materials and Methods A multienergy CT phantom, an anthropomorphic head phantom, and a cadaver head were scanned on a research PCD-CT scanner using ultra-high-resolution mode at 100-kV tube potential with an additional tin filter (Sn-100 kV) and volume CT dose index of 10 mGy. They were also scanned on a commercial CT scanner with an energy-integrating detector (EID) following standard clinical protocols. Thirty patients referred to clinically indicated sinus examinations, and two patients referred to temporal bone examinations were scanned on the PCD-CT system after their clinical scans on an EID-CT. For the sinus cohort, PCD-CT scans were performed using Sn-100 kV at 4 dose levels at 10 mGy (n = 9), 8 mGy (n = 7), 7 mGy (n = 7), and 6 mGy (n = 7), and the clinical EID-CT was performed at 120 kV and 13.7 mGy (mean CT volume dose index). For the temporal bone scans, PCD-CT was performed using Sn-100 kV (10.1 mGy), and EID-CT was performed at 120 kV and routine clinical dose (52.6 and 66 mGy). For both PCD-CT and EID-CT, sinus images were reconstructed using H70 kernel at 0.75-mm slice thickness, and temporal bone images were reconstructed using a U70 kernel at 0.6-mm slice thickness. In addition, iterative reconstruction with a dedicated sharp kernel (V80) was used to obtain high-resolution PCD-CT images from a sinus patient scan to demonstrate improved anatomic delineation. Improvements in spatial resolution from the dedicated sharp kernel was quantified using modulation transfer function measured with a wire phantom. A neuroradiologist assessed the H70 sinus images for visualization of critical anatomical structures in low-dose PCD-CT images and routine-dose EID-CT images using a 5-point Likert scale (structural detection obscured and poor diagnostic confidence, score = 1; improved anatomic delineation and diagnostic confidence, score = 5). Image contrast and noise were measured in representative regions of interest and compared between PCD-CT and EID-CT, and the noise difference between the 2 acquisitions was used to estimate the dose reduction in the sinus and temporal bone patient cohorts. Results The multienergy phantom experiment showed a noise reduction of 26% in the Sn-100 kV PCD-CT image, corresponding to a total dose reduction of 56% compared with EID-CT (clinical dose) without compromising image contrast. The PCD-CT images from the head phantom and the cadaver scans demonstrated a dose reduction of 67% and 83%, for sinus and temporal bone examinations, respectively, compared with EID-CT. In the sinus cohort, PCD-CT demonstrated a mean dose reduction of 67%. The 10- and 8-mGy sinus patient images from PCD-CT were significantly superior to clinical EID-CT for visualization of critical sinus structures (median score = 5 ± 0.82 and P = 0.01 for lesser palatine foramina, median score = 4 ± 0.68 and P = 0.039 for nasomaxillary sutures, and median score = 4 ± 0.96 and P = 0.01 for anterior ethmoid artery canal). The 6- and 7-mGy sinus patient images did not show any significant difference between PCD-CT and EID-CT. In addition, V80 (sharp kernel, 10% modulation transfer function = 18.6 cm −1 ) PCD-CT images from a sinus patient scan increased the conspicuity of nasomaxillary sutures compared with the clinical EID-CT images. The temporal bone patient images demonstrated a dose reduction of up to 85% compared with clinical EID-CT images, whereas visualization of inner ear structures such as the incudomalleolar joint were similar between EID-CT and PCD-CT. Conclusions Phantom and cadaver studies demonstrated dose reduction using Sn-100 kV PCD-CT compared with current clinical EID-CT while maintaining the desired image contrast. Dose reduction was further validated in sinus and temporal bone patient studies. The ultra-high resolution capability from PCD-CT allowed improved anatomical delineation for sinus imaging compared with current clinical standard.