Citations

Showing 10 of 108083 citations.

Advances in peripheral nerve regeneration as it relates to VCA
Suchyta, Marissa , Sabbagh, M. Diya , Morsy, Mohamed , Moran, Steven L. , Mardini, Samir

Mayo Clinic

Vascularized Composite Allotransplantation | June 30, 2017 | Volume: 3 | Issue: 1-2 | Pages: 75-88

10.1080/23723505.2017.1344347 Get It

Quality measurement for rhinosinusitis: a review from the Quality Improvement Committee of the American Rhinologic Society
Rudmik, Luke , Mattos, José L. , Schneider, John S. , Manes, Peter R., Stokken, Janalee K., Lee, Jivianne, Schlosser, Rodney J. , Reh, Douglas D., Setzen, Michael, Stokken, Janalee K. , Lee, Jivianne T. , Higgins, Thomas S , Soler, Zachary M. , Schlosser, Rodney J , Carlson, Matthew L , Mattos, Jose

Mayo Clinic

International Forum of Allergy & Rhinology | June 30, 2017 | Volume: 7 | Issue: 9 | Pages: 853-860

10.1002/alr.21983 | PMID 28665549 Get It

BackgroundMeasuring quality outcomes is an important prerequisite to improve quality of care. Rhinosinusitis represents a high value target to improve quality of care because it has a high prevalence of disease, large economic burden, and large practice variation. In this study we review the current state of quality measurement for management of both acute (ARS) and chronic rhinosinusitis (CRS).MethodsThe major national quality metric repositories and clearinghouses were queried. Additional searches included the American Academy of Otolaryngology–Head and Neck Surgery database, PubMed, and Google to attempt to capture any additional quality metrics.ResultsSeven quality metrics for ARS and 4 quality metrics for CRS were identified. ARS metrics focused on appropriateness of diagnosis (n = 1), antibiotic prescribing (n = 4), and radiologic imaging (n = 2). CRS quality metrics focused on appropriateness of diagnosis (n = 1), radiologic imaging (n = 1), and measurement of patient quality of life (n = 2). The Physician Quality Reporting System (PQRS) currently tracks 3 ARS quality metrics and 1 CRS quality metric. There are no outcome‐based rhinosinusitis quality metrics and no metrics that assess domains of safety, patient‐centeredness, and timeliness of care.ConclusionsThe current status of quality measurement for rhinosinusitis has focused primarily on the quality domain of efficiency and process measures for ARS. More work is needed to develop, validate, and track outcome‐based quality metrics along with CRS‐specific metrics. Although there has been excellent work done to improve quality measurement for rhinosinusitis, there remain major gaps and challenges that need to be considered during the development of future metrics.
BIOMARKERS OF AGING AND ALZHEIMER’S DISEASE
Petersen, R. C.

Mayo Clinic

Innovation in Aging | June 30, 2017 | Volume: 1 | Issue: suppl_1 | Pages: 296-296

10.1093/geroni/igx004.1100 Get It

KEYNOTE: HOW EARLY CAN WE DETECT COGNITIVE DISORDERS
Petersen, R. C.

Mayo Clinic

Innovation in Aging | June 30, 2017 | Volume: 1 | Issue: suppl_1 | Pages: 296-296

10.1093/geroni/igx004.1099 Get It

THE PATH TOWARD TRANSLATING SENOLYTIC DRUGS INTO CLINICAL TREATMENTS
Kirkland, James L.

Mayo Clinic

Innovation in Aging | June 30, 2017 | Volume: 1 | Issue: suppl_1 | Pages: 743-743

10.1093/geroni/igx004.2681 Get It

A novel and fast method for proton range verification using a step wedge and 2D scintillator
Shen, Jiajian , Allred, Bryce C., Robertson, Daniel , Remmes, Nicholas B. , Keole, Sameer R., Bues, Martin , Robertson, Daniel G, Liu, Wei , Sio, Terence T. , Shen, Jiajian , Bues, Martin

Mayo Clinic

Medical Physics | June 30, 2017 | Volume: 44 | Issue: 9 | Pages: 4409-4414

10.1002/mp.12439 | PMID 28665529 Get It

PurposeTo implement and evaluate a novel and fast method for proton range verification by using a planar scintillator and step wedge.MethodsA homogenous proton pencil beam plan with 35 energies was designed and delivered to a 2D flat scintillator with a step wedge. The measurement was repeated 15 times (3 different days, 5 times per day). The scintillator image was smoothed, the Bragg peak and distal fall off regions were fitted by an analytical equation, and the proton range was calculated using simple trigonometry. The accuracy of this method was verified by comparing the measured ranges to those obtained using an ionization chamber and a scanning water tank, the gold standard. The reproducibility was evaluated by comparing the ranges over 15 repeated measurements. The sensitivity was evaluated by delivering to same beam to the system with a film inserted under the wedge.ResultsThe range accuracy of all 35 proton energies measured over 3 days was within 0.2 mm. The reproducibility in 15 repeated measurements for all 35 proton ranges was ±0.045 mm. The sensitivity to range variation is 0.1 mm for the worst case. This efficient procedure permits measurement of 35 proton ranges in less than 3 min. The automated data processing produces results immediately. The setup of this system took less than 5 min. The time saving by this new method is about two orders of magnitude when compared with the time for water tank range measurements.ConclusionsA novel method using a scintillator with a step wedge to measure the proton range was implemented and evaluated. This novel method is fast and sensitive, and the proton range measured by this method was accurate and highly reproducible.
GROWTH DIFFERENTIATION FACTORS AND SENESCENCE-RELATED PROTEINS AS MODIFIERS OF AGING
LeBrasseur, Nathan K.

Mayo Clinic

Innovation in Aging | June 30, 2017 | Volume: 1 | Issue: suppl_1 | Pages: 28-28

10.1093/geroni/igx004.107 Get It

BIOLOGICAL MARKERS IN FAMILY RESEARCH
Bangerter, L., Zarit, Steven Howard

Mayo Clinic

Innovation in Aging | June 30, 2017 | Volume: 1 | Issue: suppl_1 | Pages: 11-11

10.1093/geroni/igx004.038 Get It

Simulation for Assessment of the Practice of Board-certified Anesthesiologists
Lien, Cynthia A. , Warner, Mark A. , Rathmell, James P.

Mayo Clinic

Anesthesiology | June 30, 2017 | Volume: 127 | Issue: 3 | Pages: 410-412

10.1097/aln.0000000000001792 | PMID 28671902 Get It

Vesical Neck Reconstruction in Patients with Epispadias-exstrophy
Ritchey, Michael L., Kramer, Stephen A., Kelalis, Panayotis P.

Mayo Clinic

Journal of Urology | June 30, 2017 | Volume: 139 | Issue: 6 | Pages: 1278-1281

10.1016/s0022-5347(17)42892-8 | PMID 3373600 Get It