Citations

Showing 10 of 108094 citations.

Directly Reading The Genome
Carmichael, Stephen W., Maihle, Nita J.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 9 | Issue: 2 | Pages: 3-7

10.1017/s1551929500056388 Get It

Abstract The code for the human genome is essentially complete, opening an expansive book about our biologic composition. But the problem is to read this book. The font size is very small, What you are reading now is 9 point font, and genetic information would correspond to approximately 10-50 point font, six orders of magnitude smaller. There are methods to derive genetic information, but recently Adam Woolley, Chantal Guillemette, Chin-Li Cheung, David Housman, and Charles Lieber have developed an elegant way to directly read genetic information with a microscope. The microscope they used was an atomic force microscope (AFM) that employed a single-walled carbon nanotube as its probe.
Typing Blood Cells, One At A Time
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 8 | Issue: 7 | Pages: 3-7

10.1017/s1551929500054602 Get It

Abstract We are all familiar with the 4 groups of human blood types; 0, A, B, and AB. Each group is characterized by specific molecules on the surface of the red blood cells (RBCs). Recently, Michel Grandbois, Wolfgang Dettmann, Martin Benoit, and Hermann Gaub have modified the atomic force microscope (AFM) to use the different affinities of these molecules to produce an image. A key step was to specifically functionalize the scanning probe tip of the AFM. What this means is to covalently attach an active molecule to the tip. The active molecule they used was a Iectin derived from the snail Helix pomatia (this is the same snail valued by the French as escargot). This Iectin binds specifically to molecules found on the surface of RBCs in blood group A (N-acetylgalactosamine-terminated glycolipids), but these molecules are not found in blood group O. But if the Iectin was bound directly to the AFM tip, nonspecific adsorption to the specimens would occur.
Cell-Free Secretion
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 8 | Issue: 4 | Pages: 3-7

10.1017/s1551929500063392 Get It

Abstract Regulated secretion occurs when the ceil detects a signal, vesicles containing the secretory product fuse with the plasma membrane of the cell, and the contents are released into the extracellular space. This mechanism is called exocytosis. Many laboratories around the world have studied exocytosis for the past couple of decades, and we know a lot about the many steps that are involved. The cytoskeleton appears to play a role in allowing vesicles to approach the plasma membrane, and many other proteins are in the cascade between reception of the signal and the release of the secretory products.
Do Pathologists Use The Electron Microscope Enough?
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 9 | Issue: 1 | Pages: 3-7

10.1017/s1551929500051282 Get It

Abstract The compound light microscope has been used by patholo gists for centuries, and remains the common tool for making a diagnosis. A half century ago, the electron microscope (EM) was introduced, and has aiso been proven to be a valuable, but expensive, tool. In the meantime, other tools and methods have worked their way into the pathologists’ armamentarium, with immunohistochemical, genetic, and molecular techniques being the most obvious examples. Josep Lloreta-Truil, Lola Ferrer, Teresa Ribalta, Marco Pavesi, and Sergio Serrano examined the literature to determine the frequency and appropriateness with which pathologists use the EM in their studies.
Associations of Obstructive Sleep Apnea With Atrial Fibrillation and Continuous Positive Airway Pressure Treatment
Linz, Dominik , McEvoy, R. Doug , Cowie, Martín , Lévy, Patrick , Kalman, Jonathan M. , Sanders, Prashanthan , Sanders, Prashanthan , Lévy, Patrick , Linz, Dominik , Somers, Virend K. , Nattel, Stanley , Cowie, Martin R

Mayo Clinic

JAMA Cardiology | March 14, 2018 | Volume: 3 | Issue: 6 | Pages: 532

10.1001/jamacardio.2018.0095 | PMID 29541763 Get It

Torn or Todd’s: tend to the postictal immobilised arm
Fracica, Elizabeth , Fracica, Elizabeth A , Hawkes, Maximiliano A. , Wijdicks, Eelco F. M.

Mayo Clinic

Practical Neurology | March 14, 2018 | Volume: 18 | Issue: 5 | Pages: 407-409

10.1136/practneurol-2017-001879 | PMID 29540447 Get It

Greedy Technique and Its Validation for Fusion of Two Segmentation Paradigms Leads to an Accurate Intima–Media Thickness Measure in Plaque Carotid Arterial Ultrasound
Zeng, Guang , Suri, Jasjit S. , Molinari, Filippo , Suri, Jasjit S.

Mayo Clinic

Journal for Vascular Ultrasound | March 14, 2018 | Volume: 34 | Issue: 2 | Pages: 63-73

10.1177/154431671003400201 Get It

The intima–media thickness (IMT) of carotid arteries is a reliable indicator of cardiovascular risk. IMT is usually manually measured on longitudinal B-mode ultrasound images. Many computer-based techniques for IMT measurement have been proposed to overcome the limits of manual segmentation. Most of these, however, require a certain degree of user interaction. We recently developed two automated techniques for segmentation of carotid arteries in ultrasound images and its intima–media thickness (IMT) measurement. The first technique was determined on the basis of local statistics and signal analysis (we named it CULEXsa, ie, Completely User-independent Layer EXtraction based on signal analysis). The second technique was determined on the basis of an integrated approach consisting of feature extraction, line fitting, and classification (or CALEXia, Completely Automated Layers EXtraction based on integrated approach). Both the techniques automatically traced the lumen—intima (LI) and the media—adventitia (MA) boundaries of the carotid wall. IMT was measured as the distance between LI and MA. We observed that CULEXsa offers better performance in the LI segmentation and CALEXia offers better performance in MA segmentation. The goal of this research was to estimate the IMT measurement by using a greedy approach by fusing CULEXsa and CALEXia segmentations, given the ground truth (manually traced by experts). Starting from the technique with the lower system error (CULEXsa for LI and CALEXia for MA), we iteratively swapped the vertices of the profiles until we minimized its overall distance with respect to manual boundary. The fusion boundary, consisting of points of CULEXsa and points of CALEXia, was the Greedy boundary. We used the polyline distance as a metric for both performance evaluation and error minimization. We ran the segmentation protocol over the database of 200 carotid longitudinal B-mode ultrasound images and compared the performance of all the three techniques. The mean error of the greedy technique yielded 0.42 ± 0.89 pixel (26.3 ± 55.6 μm) for the LI boundary (a 12.5 ± 5.6% improvement over CULEXsa) and 0.26 ± 0.56 pixel (16.2 ± 31.3 μm) for MA boundary (a 16.1 ± 6.7% improvement over CALEXia). IMT measurement error is 1.33 ± 0.99 pixel (83.1 ± 61.8 μm), a 3.6 ± 1.4% improvement over CULEXsa.
Incidence and Clinical Significance of New-Onset Device-Detected Atrial Tachyarrhythmia
Belkin, Mark N. , Soria, Cesar, Waldo, Albert L., Borleffs, C. Jan Willem, Hayes, David L. , Tung, Roderick , Upadhyay, Gaurav A. , Soria, Cesar E, Singh, Jagmeet P, Singh, Jagmeet P

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | March 14, 2018 | Volume: 11 | Issue: 3 | Pages: No page available

10.1161/circep.117.005393 | PMID 29540371 Get It

Background: Despite the clear association between atrial fibrillation and risk for thromboembolic events (TEs), the clinical significance of new-onset device-detected atrial tachyarrhythmia (DDAT) and TE remains disputed. We aimed to determine the risk of TE in patients with new-onset DDAT. Methods and Results: The OVID Medline, Cochrane, and Scopus databases (inception to November 2016) were searched. Randomized controlled trials, prospective, or retrospective studies of pacemaker or defibrillator patients reporting incidence of DDAT were selected. Summary statistics were used for analysis. Of 4893 reports identified, 28 studies following 24 984 patients were included: average age 69.9 years, 34.7% women, mean study duration 21.8±18.6 months. New-onset DDAT was observed in 23% of patients. Among 9 studies (n=8181) reporting TE, the absolute incidence was 2.1%. TE risk was significantly greater among patients with new-onset DDAT (relative risk [RR], 2.88; 95% CI, 1.79–4.64; P <0.001). TE risk was correlated with DDAT duration, with an increased risk associated with DDAT ≥5 minutes (RR, 3.86; 95% CI, 2.04–7.30; P <0.001) compared with <1 minute (RR, 1.77; 95% CI, 1.15–2.74; P =0.01). Notably, the risk of TE was also increased in patients with adjudicated atrial electrograms (RR, 3.60; 95% CI, 2.06–6.30; P <0.001) compared with nonadjudicated electrograms (RR, 2.05; 95% CI, 1.06–3.97; P =0.03), even when lower mean thresholds for detection were used. Conclusions: New-onset DDAT is common, affecting close to one quarter of all patients with implanted pacemakers or defibrillators. Adjudication of atrial electrograms further identifies at-risk patients, even when relatively short detection thresholds are used.
Sex Differences in Long-Term Cause-Specific Mortality After Percutaneous Coronary Intervention
Bell, Malcolm R. , Crusan, Daniel J. , Lennon, Ryan J. , Prasad, Abhiram , Rihal, Charanjit S. , Gulati, Rajiv , Raphael, Claire E. , Bell, Malcolm, Crusan, Daniel, Singh, Mandeep , Lerman, Amir , Rihal, Charanjit S. , Gersh, Bernard J. , Prasad, Abhiram

Mayo Clinic

Circulation: Cardiovascular Interventions | March 14, 2018 | Volume: 11 | Issue: 3 | Pages: No page available

10.1161/circinterventions.117.006062 | PMID 29540493 Get It

Background— Women have higher rates of all-cause mortality after percutaneous coronary intervention. Whether this is because of greater age and comorbidity burden or a sex-specific factor remains unclear. Methods and Results— We retrospectively assessed cause-specific long-term mortality after index percutaneous coronary intervention over 3 time periods (1991–1997, 1998–2005, and 2006–2012). Cause of death was determined using telephone interviews, medical records, and death certificates. We performed competing risks analyses of cause-specific mortality. A total of 6847 women and 16 280 men survived index percutaneous coronary intervention hospitalization 1991 to 2012. Women were older (mean±SD: 69.4±12 versus 64.8±11.7 years; P <0.001) with more comorbidities (mean±SD: Charlson index 2.1±2.1 versus 1.9±2.1; P <0.001). Across the 3 time periods, both sexes exhibited a decline in cardiac deaths at 5 years (26% relative decrease in women, 17% in men, trend P <0.001 for each). Although women had higher all-cause mortality compared with men in all eras, the excess mortality was because of noncardiac deaths. In the contemporary era, only a minority of deaths were cardiac (33.8% in women, 38.0% in men). After adjustment, there was no evidence for a sex-specific excess of risk for cardiac or noncardiac mortality. The commonest causes of death were chronic diseases and heart failure in women (5-year cumulative mortality, 5.4% and 3.9%) but cancer and myocardial infarction/sudden death in men (5.4% and 4.3%). Conclusions— The higher mortality after percutaneous coronary intervention in women is because of death from noncardiac causes. This is accounted for by baseline age and comorbidities rather than an additional sex-specific factor. These findings have implications for sex-specific clinical care and trial design.
Thrombus Extension into the Common Femoral Vein after Endovenous Ablation of the Greater Saphenous Vein for the Treatment of Venous Insufficiency
Berland, Todd, Hakaim, Albert G., Oldenburg, W. Andrew, Paz‐Fumagalli, Ricardo , Turan, Naciye , Falkensammer, Juergen

Mayo Clinic

Journal for Vascular Ultrasound | March 14, 2018 | Volume: 30 | Issue: 3 | Pages: 129-131

10.1177/154431670603000303 Get It

Increasingly, endovenous ablation of the greater saphenous vein (GSV) is used for the treatment of symptomatic varicose veins. The propagation of thrombus can result in a “tail of thrombus” within the common femoral vein (CFV). In two cases, patients were treated with low molecular weight heparin and re-imaged within 1 week. In both cases, complete resolution of the thrombus was confirmed, and anticoagulation was discontinued. Thrombus extension into the CFV after endovenous ablation may be safely treated with short-term anticoagulation and followed by duplex ultrasound. If unresolved, standard deep vein thrombosis anticoagulation is indicated.