Citations

Showing 10 of 108094 citations.

Microscopy used to Show how Spiders Hide!
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | May 4, 2018 | Volume: 16 | Issue: 2 | Pages: 3-5

10.1017/s1551929500055838 Get It

Abstract It has been appreciated that many invertebrates have morphologic and/or behavioral traits that help them survive by camouflage for predator avoidance or being stealthy predators themselves. The morphologic features that are involved have been described in greater detail as the technology has evolved. Recently, Rebecca Duncan, Kellar Autumn, and Greta Binford have used dissecting microscopes and scanning electron microscopes (SEM) to reveal new details of how certain species of spiders hide themselves by covering themselves with sand, and how the sand particles tenaciously stick to the spiders’ bodies.
Looking at Proteins Interacting and Folding inside Cells
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | May 4, 2018 | Volume: 16 | Issue: 3 | Pages: 3-5

10.1017/s1551929500059174 Get It

Abstract Fluorescence microscopy has revolutionized cell biology. Not only has it increased the spatial resolution with which certain processes are visualized, but it has allowed microscopists to monitor more than one event at a time. One of the remaining challenges is to see how proteins fold and assume their native conformations within living cells. Recently, Nathan Luedtke, Rachel Dexter, Daniel Fried, and Alanna Schepartz have demonstrated a technique to demonstrate these events in situ.
How Much Force Does it Take to Move an Atom on a Surface?
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | May 4, 2018 | Volume: 16 | Issue: 4 | Pages: 3-5

10.1017/s1551929500059708 Get It

Abstract It was demonstrated 18 years ago that atoms could be manipulated, one at a time, on a surface. Yet only recently has the force required to move an atom been determined. Markus Ternes, Christopher Lutz, Cyrus Hirjibehedin, Franz Giessibl, and Andreas Heinrich, in a technical tour de force, have engineered a microscope that incorporates features of the scanning tunneling microscope (STM) and atomic force microscope (AFM) to accurately quantitate the lateral and vertical forces needed to move a single atom on a surface.
STORM Offers Super-Resolution in 3D!
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | May 4, 2018 | Volume: 16 | Issue: 6 | Pages: 3-5

10.1017/s1551929500062283 Get It

Abstract For the first few centuries of microscopy, spatial resolution was limited by the diffraction barrier. Recently, this barrier has been broken using several different methods. Optical methods that provide better resolution than the diffraction barrier are referred to as super-resolution. Although these techniques have significantly improved resolution in two dimensions (x and y) or in the axial dimension (z), it has not been possible to achieve substantial improvement in all three dimensions simultaneously. A study by Bo Huang, Wenqin Wang, Mark Bates, and Xiaowei Zhuang demonstrated a breakthrough by achieving a spatial resolution that is 10 times better than the diffraction limit in all three dimensions without using sample or optical-beam scanning.
A Scanning Tunneling Microscope as a Switch in a Nanocomputer
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | May 4, 2018 | Volume: 16 | Issue: 5 | Pages: 3-5

10.1017/s155192950006168x Get It

Abstract There are several “molecular machines” that have been devised on a nanometer scale, made from proteins, DNA, and other molecules. A molecular machine is a system that generates physical forces at the atomic level, controlled by an external stimulus. Since all of the proposed circuits connect components linearly, they only communicate with one machine at a time. Now, Anirban Bandyopadhyay and Somobrata Acharya have devised an ingenious device that has the potential to communicate different instructions to many molecular machines simultaneously. They demonstrated that 2,3,5,6-tetramethyl-1–4-benzoquinone (duroquinone; DRQ) can be assembled as 17 identical molecules, one central molecule surrounded radially by 16 others. The central molecule can control the conformation of all the others when switched to one of four logic states by suitable pulses from an atomic sharp needle of a scanning tunneling microscope (STM).
Dominant strictures in primary sclerosing cholangitis: A multicenter survey of clinical definitions and practices
Hilscher, Moira , Tabibian, James H. , Carey, Elizabeth J. , Gostout, Christopher J., Lindor, Keith D. , Hilscher, Moira B, Tabibian, James H

Mayo Clinic

Hepatology Communications | May 4, 2018 | Volume: 2 | Issue: 7 | Pages: 836-844

10.1002/hep4.1194 | PMID 30027141 Get It

Dominant strictures (DSs) of the biliary tree occur in approximately 50% of patients with primary sclerosing cholangitis (PSC) and may cause significant morbidity. Nevertheless, the definition and management of DSs lacks consensus. We aimed to better understand current perceptions and practices regarding PSC‐associated DSs. We conducted an anonymous, 23‐question, survey‐based study wherein electronic surveys were distributed to 131 faculty in the Division of Gastroenterology and Hepatology at the three Mayo Clinic campuses (Rochester, Scottsdale, and Jacksonville) as well as the affiliated practice network. Responses were aggregated and compared, where applicable, to practice guidelines of the American Association for the Study of Liver Diseases and European Association for the Study of the Liver. A total of 54 faculty (41.2%) completed the survey, of whom 24 (44.4%) were hepatologists, 21 (38.9%) gastroenterologists, and 9 (16.7%) advanced endoscopists. One of the major study findings was that there was heterogeneity among participants' definition, evaluation, management, and follow‐up of DSs in PSC. The majority of participant responses were in accordance with societal practice guidelines, although considerable variation was noted. Conclusion: Despite the prevalence and morbidity of DSs in PSC, clinical perceptions and practices vary widely among hepatologists, gastroenterologists, and advanced endoscopists who manage these patients, even within a single health care system. Further studies are needed to address these variations, develop general and evidence‐based consensus, and increase adherence to societal guidelines. ( Hepatology Communications 2018;2:836‐844)
Copy number variant analysis using genome‐wide mate‐pair sequencing
Smadbeck, James B. , Johnson, Sarah H. , Smoley, Stephanie A., Gaitatzes, Athanasios , Drucker, Travis, Zenka, Roman M. , Kosari, Farhad , Hoppman, Nicole L., Sukov, William R. , Jenkins, Robert B. , Kearney, Hutton M. , Vasmatzis, George , Drucker, Travis M, Hoppman, Nicole, Aypar, Umut , Murphy, Stephen J. , Feldman, Andrew L.

Mayo Clinic

Genes, Chromosomes and Cancer | May 4, 2018 | Volume: 57 | Issue: 9 | Pages: 459-470

10.1002/gcc.5 | PMID 29726617 Get It

AbstractCopy number variation (CNV) is a common form of structural variation detected in human genomes, occurring as both constitutional and somatic events. Cytogenetic techniques like chromosomal microarray (CMA) are widely used in analyzing CNVs. However, CMA techniques cannot resolve the full nature of these structural variations (i.e. the orientation and location of associated breakpoint junctions) and must be combined with other cytogenetic techniques, such as karyotyping or FISH, to do so. This makes the development of a next‐generation sequencing (NGS) approach capable of resolving both CNVs and breakpoint junctions desirable. Mate‐pair sequencing (MPseq) is a NGS technology designed to find large structural rearrangements across the entire genome. Here we present an algorithm capable of performing copy number analysis from mate‐pair sequencing data. The algorithm uses a step‐wise procedure involving normalization, segmentation, and classification of the sequencing data. The segmentation technique combines both read depth and discordant mate‐pair reads to increase the sensitivity and resolution of CNV calls. The method is particularly suited to MPseq, which is designed to detect breakpoint junctions at high resolution. This allows for the classification step to accurately calculate copy number levels at the relatively low read depth of MPseq. Here we compare results for a series of hematological cancer samples that were tested with CMA and MPseq. We demonstrate comparable sensitivity to the state‐of‐the‐art CMA technology, with the benefit of improved breakpoint resolution. The algorithm provides a powerful analytical tool for the analysis of MPseq results in cancer.
Injuries of the Hypoglossal Nerve: Report of Ten Cases
Alrich, E. Meredith, Baker, George S., Baker, George S.

Mayo Clinic

Military Medicine | May 4, 2018 | Volume: 103 | Issue: 1 | Pages: 20-25

10.1093/milmed/103.1.20 Get It

Relationship Between Patient‐Reported Swelling and Magnetic Resonance Imaging–Defined Effusion‐Synovitis in Patients With Meniscus Tears and Knee Osteoarthritis
MacFarlane, Lindsey A. , Yang, Heidi Y. , Collins, Jamie E. , Mandl, Lisa A. , Levy, Bruce A. , Marx, Robert G. , Safran‐Norton, Clare E., Brophy, Robert H. , Losina, Elena , Brophy, Robert H. , Collins, Jamie E , Guermazi, Ali , Marx, Robert G. , Losina, Elena , Katz, Jeffrey N.

Mayo Clinic

Arthritis Care & Research | May 4, 2018 | Volume: 71 | Issue: 3 | Pages: 385-389

10.1002/acr.23592 | PMID 29726627 Get It

Objective Synovitis is a prevalent feature in patients with knee osteoarthritis ( OA ) and meniscal tear and is associated with pain and cartilage damage. Patient‐reported swelling is also prevalent in this population. The aim of this study was to investigate the cross‐sectional association between patient‐reported swelling and effusion‐synovitis detected by magnetic resonance imaging ( MRI ) in patients with OA and meniscal tear. Methods We used baseline data from a multicenter, randomized controlled trial, Meniscal Tear in Osteoarthritis Research ( METEOR ). MRI ‐identified effusion‐synovitis, a proxy for effusion and synovitis on noncontrast MRI s, was graded as none/small versus medium/large. Using MRI ‐identified effusion‐synovitis as the gold standard, we assessed the sensitivity, specificity, and positive predictive value of patient self‐reported swelling in the previous week (none, intermittent, constant) to detect effusion and synovitis. Results We analyzed data from 276 patients. Twenty‐five percent of patients reported no swelling, 40% had intermittent swelling, and 36% had constant swelling. Fifty‐two percent had MRI ‐identified medium/large–grade effusion‐synovitis. As compared with MRI ‐identified effusion‐synovitis, any patient‐reported swelling (versus none) had a sensitivity of 84% (95% confidence interval [95% CI ] 77–89), a specificity of 34% (95% CI 26–43), and a positive predictive value of 57% (95% CI 54–61). A history of constant swelling (versus none or intermittent) showed a sensitivity of 46% (95% CI 37–54), a specificity of 75% (95% CI 67–82), and a positive predictive value of 66% (95% CI 58–74). Conclusion We found that the sensitivity and specificity of patient‐reported swelling were modest when compared with effusion‐synovitis detected by MRI . These data urge caution against using patient‐reported swelling as a proxy of inflammation manifesting as effusion‐synovitis.
Newer Aspects of Aviation Neuropsychiatry
Walsh, Maurice N.

Mayo Clinic

Military Medicine | May 4, 2018 | Volume: 102 | Issue: 1 | Pages: 33-41

10.1093/milmed/102.1.33 Get It