Objective: This study evaluated the feasibility and satisfaction of using a wearable brain activity sensing device for stress reduction among patients experiencing Long COVID (LC). Patients and Methods: Patients with LC (N = 45) were invited to participate in an open-label pilot study. Participants were asked to use a brain-sensing electroencephalogram (S-EEG) wearable device (Muse-S™) daily for 90 days and followed for an additional 90 days (180 days total participation). Study enrollment began June 28, 2022, and ended July 28, 2023. Results: Patients were predominantly female (82%), white (96%), and with an average age of 47.6 (±12.5) years. At the end of treatment (90 days), cognition, sleep, self-efficacy, and quality-of-life quality of life improved ( P < .001 to P = .04). In addition, stress and anxiety were significantly reduced ( P < .001). These significant changes persisted by end-of-study (180 days). For stress ( P = .023) and anxiety ( P = .033), a change from the baseline during follow-up was significantly associated with the amount of S-EEG usage. The end-of-study satisfaction survey indicated that patients were very satisfied with the S-EEG device, and 97% planned to continue using it. Conclusion: Results suggest that the S-EEG device improved cognition in LC, which is one of the main severe symptoms we see in our LC clinic. In addition, it helped reduce stress and anxiety. These findings have important clinical implications for LC patients using S-EEG as an adjunct to concurrent LC clinical care which includes pharmacotherapies.
Acute sympathetic activation blunts the hyperemic and vasodilatory response to passive leg movement in young healthy males
AbstractHeightened muscle sympathetic nerve activity (MSNA) contributes to impaired vasodilatory capacity and vascular dysfunction associated with aging and cardiovascular disease. The contribution of elevated MSNA to the vasodilatory response during passive leg movement (PLM) is not fully understood. This study tested the hypothesis that elevated MSNA diminishes the vasodilatory response to PLM in healthy young males (n = 11, 25 ± 2 yr). Post exercise circulatory occlusion (PECO) following 2 min of isometric handgrip (HG) exercise performed at 25% (ExPECO 25%) and 40% (ExPECO 40%) maximum voluntary contraction was used to incrementally engage the metaboreceptors and augment MSNA. Control trials were performed without PECO (ExCON 25% and ExCON 40%) to account for changes due to HG exercise. PLM was performed 2 min after exercise and hemodynamics were assessed. MSNA was recorded by microneurography in the peroneal nerve (n = 8). Measures of MSNA (i.e., burst incidences) increased during ExPECO 25% (+15 ± 5 burst/100 bpm) and ExPECO 40% (+22 ± 4 burst/100 bpm) and returned to pre‐HG levels during ExCON trials. Leg vascular conductance (vasodilation) during PLM was reduced by 16% and 44% during ExPECO 25% and ExPECO 40%, respectively. These findings indicate elevated MSNA attenuates the vasodilatory response to PLM and the magnitude of reduction in vasodilation during PLM is graded with the degree of sympathoexcitation.
Design and Staged Implementation of a Multidisciplinary Preoperative Anemia Clinic at a Tertiary Care Medical Center
BACKGROUND: Preoperative anemia is common and associated with adverse outcomes in surgical patients. There is limited information to guide the design and implementation of preoperative anemia clinics (PAC), which represents a critical barrier to entry for many practices. METHODS: This is a descriptive observational study highlighting the design and implementation of a multidisciplinary PAC, including key steps in planning, stakeholder engagement, organizational structure, identification of target populations, establishing anemia treatments, information technology and electronic health record integration, provider training, and data infrastructure. Demographic and clinical characteristics, laboratory results, and anemia treatments for individuals evaluated in the PAC from November 4, 2019 through September 15, 2023 are enumerated. Patient-reported outcomes (PROs) assessing changes in anemia symptoms and well-being after surgery are evaluated for 2 subsets of patients (one before PAC implementation [pre-PAC], another after PAC implementation [post-PAC]), without formal statistical comparison given limited sample sizes. RESULTS: The PAC was initiated as a multidisciplinary effort under support from a Mayo Clinic Practice Transformation Award in 2019, including broad representation from anesthesiology, surgery, and medical practices, along with institutional project management support (eg, project manager, information technologists, systems engineers). While initially limited to cardiac surgery patients, the PAC underwent planned incremental expansion to include other surgical services. Over the study period, 1188 PAC consultations across 1159 unique patients met eligibility criteria, with a median age of 66 (57–73) years and 58.1% women. The most common etiology of anemia was iron deficiency (69.1%) followed by anemia related to cancer (17.3%). Anemia-directed therapies were recommended in 1038 (87.4%) encounters, with 730 (70.3%) of those receiving recommended treatment preoperatively. Seven hundred nine (97.1%) treatments included intravenous iron and 146 (20.0%) included erythropoiesis-stimulating agents. Fifteen pre-PAC and 38 post-PAC implementation patients completed PROs. PAC implementation was accompanied by earlier resolution of anemia symptoms and less pronounced declines in postoperative well-being scores. CONCLUSIONS: This report highlights the key steps for successful PAC implementation. Treatment is possible for most patients and may be accompanied by improvements in patient-important outcomes.
Lack of Standardized Coding Limits Accuracy of Electronic Clinical Quality Measure for Pulmonary Embolism Diagnosis
Guidelines for diagnosing pulmonary embolism (PE) start with a risk assessment using a pretest probability (PTP) tool, followed by D-dimer testing or computed tomography pulmonary angiography (CTPA) depending on risk. The project aimed to develop an electronic clinical quality measure (eCQM) to encourage broader use of a validated PTP scoring tool in emergency departments (EDs) to more accurately diagnose PE and to reduce unnecessary CTPAs. To identify a value set to accurately identify CTPA and abnormal D-dimer tests using standard classification systems and clinical vocabularies (ie, Current Procedural Terminology [CPT], Logical Observation Identifiers Names and Codes [LOINC], systematized nomenclature of medicine clinical terms [SNOMED CT]) across 3 academic United States health care systems. A comprehensive value set to identify CTPAs was selected, which contained 31 codes. Additionally, each health care system had unique, site-specific codes to more granularly identify CTPAs. Three health care systems representing 38 EDs from across the country submitted data from all ED encounters between September 12, 2022, and January 11, 2023. Imaging types were reviewed from each of the CPT codes and LOINC. The project evaluated whether a D-dimer was obtained using CPT and LOINC and whether the D-dimer result was elevated using SNOMED CT. The number of ED encounters, PTP use, and diagnosis of PE using different codes were determined. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value for selected codes were calculated. Over a 4-month study period, 270,214 encounters were included from 38 EDs. 11,794 ED encounters with CTPAs during the study period, using the site-specific codes were identified. The comprehensive value set had a PPV of 63.4%. Restricting the CTPA value set to CPT code 71275 or LOINC 88322-3 improved the PPV to 82% with 100% sensitivity and 99% specificity. The restricted value set captured the highest proportion of relevant site-specific codes. D-dimer values were identified using LOINC codes 48065-7 and 91556-1 at Site 1 and 48067-3 at Site 2. SNOMED CT codes were not used at any site to identify elevated D-dimer results. Different D-dimer tests with different normal ranges were used at each site, and only one site provided an abnormal flag for D-dimer results. Heterogeneity in the use of nationally standardized codes for labs and imaging tests limits the ability to measure and compare quality across health care organizations for CTPA and D-dimer results. Restricting the identification of CTPA to CPT Code 71275 or LOINC 88322-3 resulted in high sensitivity and specificity, but false positives remain. Additionally, coding for an abnormal D-dimer test result is not standardized across institutions. Therefore, the currently available value sets cannot be used to develop eCQMs whose aim is to evaluate whether CTPA is ordered appropriately based on the PTP risk level and laboratory testing.
1421: DISSEMINATED INTRAVASCULAR COAGULATION, A COMPLICATION OF PERCUTANEOUS RENAL BIOPSY