Citations

Clear

71 citation(s) found for "Gandhi, Manish".

72: Exploring Associations Between Genotype and Serology in Celiac Disease
Mills, John R. , Katzman, Brooke M. , Ettore, Michael, Snyder, Melissa R., Murray, Joseph A. , Gandhi, Manish J. , Snyder, Melissa R.

Mayo Clinic

American Journal of Clinical Pathology | February 3, 2017 | Volume: 143 | Issue: suppl_1 | Pages: A042-A042

10.1093/ajcp/143.suppl1.043 Get It

Double red blood cell collection: comparison of three apheresis systems
Burgstaler, Edwin A. , Duffy, Kimberly J., Gandhi, Manish J.

Mayo Clinic

Transfusion | July 13, 2016 | Volume: 56 | Issue: 9 | Pages: 2362-2367

10.1111/trf.13705 | PMID 27409536 Get It

BACKGROUNDWe compared three instruments for double red blood cell (DRBC) collection to efficiently optimize our RBC inventory.STUDY DESIGN AND METHODSInstruments compared were the TerumoBCT Trima Accel (Trima), the Fenwal Alyx (Alyx), and the Haemonetics MCS+ 8150 (MCS+). Forty consecutive collections (80 products) per instrument were evaluated for hemoglobin (Hb) content, leukoreduction, collection time, instrument efficiency, donor acceptance, and reactions. The total number of whole blood donors who could be eligible for DRBC collection was analyzed. All collections were as per the manufacturer recommendations with target volume of 360 or 400mL. Leukoreduction was integral to the collection procedure for the Alyx and Trima, while it was a separate process for the MCS+.RESULTSThe total numbers of whole blood donors who could be eligible for DRBC collection were 10,116 for the MCS+, 9378 for the Alyx, and 8573 for the Trima. All units collected had more than 42.5 g of Hb. Mean Hb levels were as follows: Trima, 59.2 g; Alyx, 56.8 g; and MCS+, 51.5 g. Donor times for the Trima, Alyx, and MCS+ were 52, 45, and 52 minutes, respectively. Technician times for the Trima, Alyx, and MCS+ (without filtration) were 87, 73, and 64 minutes. All collected products had fewer than 5 × 106 white blood cells.CONCLUSIONSAll three instruments would be capable of collecting an acceptable leukoreduced DRBC product. The Alyx was most portable, with the shortest donor time and total technician time (considering filtration time) and highest collection efficiency and would collect from more donors than the Trima. We thus chose the Alyx as it best fits the specific needs of our center.
16th IHIW: Global distribution of extended HLA haplotypes
Askar, Medhat , Daghstani, J., Thomas, Dawn, Leahy, N., Dunn, P.P.J. , Doran, Stephen , Saji, H., Kanangat, Siva, Karoichane, M., Tambur, Anat R. , Monos, Dimitri , El‐Khalifa, M. Y., Turner, Victoria , Kamoun, Malek , Mustafa, Mahiran, Ramón, Daniel S. , Vernaza, Alejandro, Gorodezky, Clara , Wagenknecht, Dawn R., Gautreaux, Michael D. , Hajeer, Ali H. , Fernández-Viña, Marcelo , Claas, Frans H.J. , Gandhi, Manish J. , Kashi, Zahra Mehdizadeh

Mayo Clinic

International Journal of Immunogenetics | October 13, 2015 | Volume: 40 | Issue: 1 | Pages: 31-38

10.1111/iji.12029 | PMID 23302097 Get It

SummaryThis report describes the project to identify the global distribution of extended HLA haplotypes, a component of 16th International HLA and Immunogenetics Workshop (IHIW), and summarizes the initial analyses of data collected. The project aims to investigate extended HLA haplotypes, compare their distribution among different populations, assess their frequency in hematopoietic stem cell unrelated donor registries and initiate an international family studies database and DNA repository to be made publicly available. HLA haplotypes compiled in immunogenetics laboratories during the evaluation of transplant candidates and related potential donors were analysed. Haplotypes were determined using the pedigree analysis tool publicly available from the National Marrow Donor Program (NMDP) website. Nineteen laboratories from 10 countries (11 laboratories from North America, five from Asia, two from Latin America and one from Australia) contributed data on a total of 1719 families comprised of 7474 individuals. We identified 10 393 HLA haplotypes, of which 1682 haplotypes included high‐resolution typing at HLA‐A, B, C, DRB1 and DQB1 loci. We also present haplotypes containing MICA and other HLA loci and haplotypes containing rare alleles seen in these families. The project will be extended through the 17th IHIW, and investigators interested in joining the project may communicate with the first author.
Recipient clinical risk factors predominate in possible transfusion‐related acute lung injury
Toy, Pearl, Bacchetti, Peter , Grimes, Barbara , Murphy, Edward L. , Gropper, Michael A. , Hubmayr, Rolf D., Matthay, Michael A. , Wilson, Gregory , Koenigsberg, Monique, Lee, Deanna C., Hirschler, Nora V., Lowell, Clifford A. , Schuller, Randy M. , Norris, Philip J. , Mair, David , Rosen, Rosa Sanchez, Looney, Mark R. , Winters, Jeffrey L. , Gajic, Ognjen , Gandhi, Manish J.

Mayo Clinic

Transfusion | December 13, 2014 | Volume: 55 | Issue: 5 | Pages: 947-952

10.1111/trf.12954 | PMID 25488517 Get It

Background Possible transfusion‐related acute lung injury (p TRALI ) cases by definition have a clear temporal relationship to an alternative recipient risk factor for acute respiratory distress syndrome ( ARDS ). We questioned whether transfusion factors are important for the development of p TRALI . Study Design and Methods In this nested case‐control study, we prospectively identified 145 consecutive patients with p TRALI and randomly selected 163 transfused controls over a 4‐year period at the U niversity of C alifornia at S an F rancisco and the M ayo C linic ( R ochester, M innesota). Results For p TRALI , we found evidence against transfusion being important: receipt of plasma from female donors (odds ratio [ OR ], 0.82; 95% confidence interval [ CI ], 0.29‐2.3; p = 0.70), total number of units transfused ( OR , 0.99; 95% CI , 0.89‐1.10; p = 0.86), and number of red blood cell and whole blood units transfused ( OR , 0.78; 95% CI , 0.59‐1.03; p = 0.079). In contrast, we found that risk for p TRALI was associated with additional recipient factors: chronic alcohol abuse ( OR , 12.5; 95% CI , 2.8‐55; p < 0.001), current smoker ( OR , 4.2; 95% CI , 1.67‐10.8; p = 0.0024), shock before transfusion ( OR , 4.6; 95% CI , 2.0‐10.7; p < 0.001), and positive fluid balance before transfusion ( OR , 1.32/ L ; 95% CI , 1.20‐1.44; p < 0.001). Conclusion Recipient risk factors for ARDS rather than transfusion risk factors predominate in p TRALI .
Antibody-mediated rejection despite inhibition of terminal complement
Bentall, Andrew , Tyan, Dolly B., Sequeira, Flavia, Everly, Matthew J. , Gandhi, Manish J. , Cornell, Lynn D. , Henderson, Nicole , Raghavaiah, Suresh , Dean, Patrick G. , Stegall, Mark D. , Li, Han , Winters, Jeffrey L. , Stegall, Mark D , Bentall, Andrew , Cornell, Lynn

Mayo Clinic

Transplant International | July 2, 2014 | Volume: 27 | Issue: 12 | Pages: 1235-1243

10.1111/tri.12396 | PMID 24990476 Get It

In Reply
Kreuter, Justin D. , Gandhi, Manish J.

Mayo Clinic

Clinical Chemistry | January 9, 2014 | Volume: 60 | Issue: 2 | Pages: 424-424

10.1373/clinchem.2013.218115 | PMID 24620365 Get It

Economic Rewards for Blood Donation: Validity of the Donor Questionnaire as Litmus Test
Kreuter, Justin D. , Gandhi, Manish J.

Mayo Clinic

Clinical Chemistry | September 27, 2013 | Volume: 59 | Issue: 10 | Pages: 1538-1539

10.1373/clinchem.2013.211599 | PMID 24215083 Get It

Amino acid substitution at peptide-binding pockets of HLA class I molecules increases risk of severe acute GVHD and mortality
Pidala, Joseph, Wang, Tao , Haagenson, Michael , Askar, Medhat , Baxter‐Lowe, Lee Ann , Bitan, Menachem, Fernández-Viña, Marcelo , Jakubowski, Ann A. , Maiers, Martin , Marino, Susana R. , Oudshoorn, Machteld, Palmer, Jeanne , Prasad, Vinod K. , Reddy, Vijay , Ringdén, Olle , Saber, Wael , Santarone, Stella , Schultz, Kirk R. , Setterholm, Michelle, Trachtenberg, Elizabeth, Turner, E. Victoria, Woolfrey, Ann E. , Lee, Stephanie J. , Anasetti, Claudio , Spellman, Stephen R. , Battiwalla, Minoo , Gandhi, Manish J. , Marsh, Steven G. E. , Ringden, Olov , Lee, Stephanie J , Maiers, Martin

Mayo Clinic

Blood | August 28, 2013 | Volume: 122 | Issue: 22 | Pages: 3651-3658

10.1182/blood-2013-05-501510 | PMID 23982174 Get It

Key PointsAmino acid substitution at peptide-binding residues of the HLA class I molecule is associated with graft-versus-host disease and mortality. Avoidance of donor-recipient combinations that result in amino acid substitution at peptide-binding residues may improve transplant outcomes.
Lot‐to‐lot variability in HLA antibody screening using a multiplexed bead‐based assay
Carrick, Danielle M. , Jenkins, Sarah M. , Goey, Steven R. De, Ploeger, Nancy A., Wilson, Gregory , Lee, Jar How, Winters, Jeffrey L. , Stubbs, James R. , Toy, Pearl, Norris, Philip J. , Gandhi, Manish J. , Winters, Jeffrey L

Mayo Clinic

Transfusion | January 11, 2013 | Volume: 53 | Issue: 9 | Pages: 1940-1947

10.1111/trf.12064 | PMID 23305156 Get It

BackgroundIdentifying antibodies to HLA (anti‐HLA) by solid‐phase assays is used to screen blood donors to mitigate transfusion‐related acute lung injury risk. Various cutoffs for detection assays have been proposed in the literature; however, these do not take into consideration lot‐to‐lot variability of commercially available assays.Study Design and MethodsSamples from 93 nontransfused males were tested using five different lots of a multiplex bead‐based anti‐HLA detection kit. A subset of 17 samples was tested on 5 days using a single lot. An additional 96 samples from donations with varied anti‐HLA levels were tested using kits from two different lots. Results were reported as a normalized background (NBG) ratio.ResultsFor the 93 nontransfused donors, NBG values generated using the reference lot were significantly higher than those obtained with three of the four comparator lots. However, for the 96 samples with low‐, moderate‐, and higher‐level anti‐HLA, Class I (CL‐I) values were 1.4 times lower and Class II (CL‐II) values were 1.2 times lower using the reference versus comparator lot. For CL‐I antibodies the between‐lot standard deviation (SD) was 1.36 (95% confidence interval [CI], 1.19‐1.60), while the between‐day SD was 1.27 (95% CI, 1.08‐1.52). Similarly, for CL‐II antibodies the between‐lot SD was 0.81 (95% CI, 0.70‐0.95), while the between‐day SD was 0.50 (95% CI, 0.43‐0.60).ConclusionsThere is interlot variability in the tested HLA detection assay as well as significant bias between lots. It may be reasonable to develop a new cutoff when a new lot is obtained.