Citations

Showing 10 of 108152 citations.

Management of induction failures in newly diagnosed transplant-eligible multiple myeloma
Gertz, Morie A. , Gertz, Morie A

Mayo Clinic

Leukemia & Lymphoma | September 10, 2019 | Volume: 61 | Issue: 1 | Pages: 1-3

10.1080/10428194.2019.1663424 | PMID 31502884 Get It

Objective Outcomes in Upper Blepharoplasty
Boonipat, Thanapoom , Charaffadine, Ali, Fleming, Kevin D., Bite, Uldis, Stotland, Mitchell A. , Abu‐Ghname, Amjed , Fleming, Kevin K.

Mayo Clinic

Plastic and Reconstructive Surgery - Global Open | September 10, 2019 | Volume: 7 | Issue: 8S-1 | Pages: 137-138

10.1097/01.gox.0000585028.07793.16 Get It

Prognostic Indicators for Upper and Lower Extremity Amputations in a Verified Burn Center
Thornburg, Danielle A. , Swanson, Scott D. , Elebrashi, Yehia, Richards, Nicole, Richey, Karen , Kowal-Vern, Areta , Foster, Kevin N , Matthews, Marc R. , Richards, Nicole

Mayo Clinic

Plastic and Reconstructive Surgery - Global Open | September 10, 2019 | Volume: 7 | Issue: 8S-1 | Pages: 112-113

10.1097/01.gox.0000584872.79084.21 Get It

Reconstruction of Complex Hemipelvectomy Defects: A 17-year Single-institutional Experience With Lower Extremity Free and Pedicled Fillet Flaps
Kreutz‐Rodrigues, Lucas , Weissler, Jason M., Carlsen, Brian T. , Rose, Peter S. , Bakri, Karim , Houdek, Matthew T.

Mayo Clinic

Plastic and Reconstructive Surgery - Global Open | September 10, 2019 | Volume: 7 | Issue: 8S-1 | Pages: 108-108

10.1097/01.gox.0000584844.69674.a7 Get It

Intravenous Tranexamic Acid in Implant-based Breast Reconstruction Safely Reduces Hematoma Without Thromboembolic Events
Banuelos, Joseph, Weissler, Jason M., Harless, Christin A., Jacobson, Steven R., Tran, Nho V. , Nguyen, Minh-Doan T. , Manrique, Oscar J. , Martinez‐Jorge, Jorys

Mayo Clinic

Plastic and Reconstructive Surgery - Global Open | September 10, 2019 | Volume: 7 | Issue: 8S-1 | Pages: 87-87

10.1097/01.gox.0000584712.07862.aa Get It

The Use of Vertical Rectus Abdominis Myocutaneous Flap for Pelvic Reconstruction: What Are the Risk Factors for Complications?
Kreutz‐Rodrigues, Lucas , Banuelos, Joseph, Saleem, Humza Y. , Mills, Andrew , Tran, Nho V. , Bakri, Karim

Mayo Clinic

Plastic and Reconstructive Surgery - Global Open | September 10, 2019 | Volume: 7 | Issue: 8S-1 | Pages: 75-75

10.1097/01.gox.0000584640.41927.51 Get It

Novel Method of Double Innervated Free Gracilis Muscle Functional Transfer for Facial Reanimation
Boonipat, Thanapoom , Sabbagh, M. Diya , Asaad, Malke , Robertson, Carrie E. , Mardini, Samir

Mayo Clinic

Plastic and Reconstructive Surgery - Global Open | September 10, 2019 | Volume: 7 | Issue: 8S-1 | Pages: 60-60

10.1097/01.gox.0000584552.10540.58 Get It

Craniofacial Fellowship Trained Surgeons: Where Are They Now?
Howarth, Ashley L. , Kurnik, Nicole M. , Rebecca, Alanna M. , Singh, Davinder

Mayo Clinic

Plastic and Reconstructive Surgery - Global Open | September 10, 2019 | Volume: 7 | Issue: 8S-1 | Pages: 59-59

10.1097/01.gox.0000584544.25788.14 Get It

Image Artifact Management for Clinical Magnetic Resonance Imaging on a 7 T Scanner Using Single-Channel Radiofrequency Transmit Mode
Fagan, Andrew , Welker, Kirk M. , Amrami, Kimberly K. , Frick, Matthew A., Watson, Robert E. , Kollasch, Peter , Chebrolu, Venkata V. , Felmlee, Joel P. , Fagan, Andrew J

Mayo Clinic

Investigative Radiology | September 10, 2019 | Volume: 54 | Issue: 12 | Pages: 781-791

10.1097/rli.0000000000000598 | PMID 31503079 Get It

Objectives The aim of this work was to devise mitigation strategies for addressing a range of image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory-approved single-channel radiofrequency transmit mode and vendor-supplied radiofrequency coils to facilitate clinical scanning within reasonable scan times. Materials and Methods Optimized imaging sequence protocols were developed for routine musculoskeletal knee and neurological imaging. Sources of severe image nonuniformities were identified, and mitigation strategies were devised. A range of custom-made high permittivity dielectric pads were used to compensate for B1 + and B1 − inhomogeneities, and also for magnetic susceptibility-induced signal dropouts particularly in the basal regions of the temporal lobes and in the cerebellum. Results Significant improvements in image uniformity were obtained using dielectric pads in the knee and brain. A combination of small voxels, reduced field of view B0 shimming, and high in-plane parallel imaging factors helped to minimize signal loss in areas of high susceptibility-induced field distortions. The high inherent signal-to-noise ratio at 7 T allowed for high receiver bandwidths and thin slices to minimize chemical shift artifacts. Intermittent artifacts due to radiofrequency inversion pulse limitations (power, bandwidth) were minimized with dielectric pads. A patient with 2 implanted metallic cranial fixation devices located within the radiofrequency transmit field was successfully imaged, with minimal image geometric distortions. Conclusions Challenges relating to severe image artifacts at 7 T using single-channel radiofrequency transmit functionality in the knee and brain were overcome using the approaches described in this article. The resultant high diagnostic image quality paves the way for incorporation of this technology into the routine clinical workflow. Further developmental efforts are required to expand the range of applications to other anatomical areas, and to expand the evidence- and knowledge-base relating to the safety of scanning patients with implanted metallic devices.
Noninvasive Urinary Monitoring of Progression in IgA Nephropathy
Yang, Joshua , Sarwal, Reuben D. , Sarwal, Minnie , Lafayette, Richard , Yang, Joshua Y C , Fervenza, Fernando C.

Mayo Clinic

International Journal of Molecular Sciences | September 10, 2019 | Volume: 20 | Issue: 18 | Pages: 4463

10.3390/ijms20184463 | PMID 31510053 Get It

Standard methods for detecting and monitoring of IgA nephropathy (IgAN) have conventionally required kidney biopsies or suffer from poor sensitivity and specificity. The Kidney Injury Test (KIT) Assay of urinary biomarkers has previously been shown to distinguish between various kidney pathologies, including chronic kidney disease, nephrolithiasis, and transplant rejection. This validation study uses the KIT Assay to investigate the clinical utility of the non-invasive detection of IgAN and predicting the progression of renal damage over time. The study design benefits from longitudinally collected urine samples from an investigator-initiated, multicenter, prospective study, evaluating the efficacy of corticosteroids versus Rituximab for preventing progressive IgAN. A total of 131 urine samples were processed for this study; 64 urine samples were collected from 34 IgAN patients, and urine samples from 64 demographically matched healthy controls were also collected; multiple urinary biomarkers consisting of cell-free DNA, methylated cell-free DNA, DMAIMO, MAMIMO, total protein, clusterin, creatinine, and CXCL10 were measured by the microwell-based KIT Assay. An IgA risk score (KIT-IgA) was significantly higher in IgAN patients as compared to healthy control (87.76 vs. 14.03, p < 0.0001) and performed better than proteinuria in discriminating between the two groups. The KIT Assay biomarkers, measured on a spot random urine sample at study entry could distinguish patients likely to have progressive renal dysfunction a year later. These data support the pursuit of larger prospective studies to evaluate the predictive performance of the KIT-IgA score in both screening for non-invasive diagnosis of IgAN, and for predicting risk of progressive renal disease from IgA and utilizing the KIT score for potentially evaluating the efficacy of IgAN-targeted therapies.