Citations

Showing 10 of 108162 citations.

Medicare Prescription Drug Plan Formulary Restrictions After Postmarket FDA Black Box Warnings
Solotke, Michael T. , Ross, Joseph S. , Shah, Nilay D. , Karaca‐Mandic, Pinar , Dhruva, Sanket S. , Ross, Joseph S

Mayo Clinic

Journal of Managed Care & Specialty Pharmacy | October 30, 2019 | Volume: 25 | Issue: 11 | Pages: 1201-1217

10.18553/jmcp.2019.25.11.1201 | PMID 31663461 Get It

Effect of incremental increase in radial neck height on coronoid and capitellar contact pressures
Ramazanian, Taghi , Müller-Lebschi, Julia A., Chuang, Min-Yao , Vaichinger, Anthony M. , Fitzsimmons, James S. , O’Driscoll, Shawn W. , Fitzsimmons, James S

Mayo Clinic

Shoulder & Elbow | October 30, 2019 | Volume: 13 | Issue: 4 | Pages: 445-450

10.1177/1758573219881772 | PMID 34394742 Get It

Background Over-lengthening of the radial neck has been shown to affect ulnohumeral kinematics and has been proposed to affect radiocapitellar pressures. We hypothesized that an incremental increase in radial neck height increases the capitellar contact pressure and reduces the coronoid contact pressure. Knowledge of the effects of over-lengthening is clinically important in preventing pain and degenerative changes due to overstuffing. Methods Six human cadaveric elbows were prepared on a custom-designed apparatus simulating muscle loads and passive flexion from 0° to 90° under gravity valgus torque while measuring joint contact pressures in this biomechanical study. Each elbow was tested sequentially starting with the intact specimen followed by insertion of a radial head prosthesis with 0, +2, and +4 mm of radial neck height, respectively. Results Capitellar mean contact pressures significantly increased after insertion of +2 and +4 mm radial head prostheses (p < 0.03). The capitellar mean contact pressure with a 0 mm radial head prosthesis was 97 KPa. Insertion of +2 mm and +4 mm radial heads increased mean contact pressures to 391 KPa (p = 0.001) and 619 KPa (p = 0.001), respectively, with 90° of elbow flexion. Discussion Increasing radial prosthesis height by 2 mm significantly increases capitellar contact pressures and reduces coronoid contact pressures.
Augmented cerebral blood velocity in response to isometric handgrip exercise in women with a history of preeclampsia
Miller, Kathleen B. , Miller, Virginia M. , Harvey, Ronée E. , Ranadive, Sushant M. , Barnes, Jill N. , Ranadive, Sushant M. , Barnes, J N , Harvey, Ronée E , Ranadive, Sushant , Joyner, Michael J.

Mayo Clinic

American Journal of Physiology-Regulatory, Integrative and Comparative Physiology | October 30, 2019 | Volume: 317 | Issue: 6 | Pages: R834-R839

10.1152/ajpregu.00280.2019 | PMID 31663771 Get It

Preeclampsia (PE) is a hypertensive disorder of pregnancy described as a condition of excessive sympathoexcitation. PE places a woman at increased risk for lifelong hypertension and cognitive impairment. Cerebral blood velocity is blunted in response to a vasoactive stimulus in women with a history of PE. This study investigated how a sympathoexcitatory stimulus affects cerebral blood velocity in women with a history of PE. Middle cerebral artery blood velocity (MCAv) and beat-to-beat mean arterial blood pressure (MAP) were measured in postmenopausal women with a history of PE ( n = 21; age = 59 ± 5 yr) and a history of a normotensive pregnancy (NP; n = 27; age = 58 ± 4 yr), at baseline, during isometric handgrip to fatigue (IHG) followed by postexercise ischemia (PEI), and a recovery period (REC). Baseline MAP and MAP responses to IHG and PEI did not differ between groups. MCAv at baseline and throughout the stimulus was lower in PE women compared with NP women ( P < 0.05 for all). MCAv increased during IHG in both groups ( P < 0.05). This increase in MCAv was greater in PE compared with NP women during IHG and REC (IHG: PE 13 ± 2% vs. NP 9 ± 2%; REC: PE 3 ± 2% vs. NP −2 ± 2%; P < 0.05 for both). Thus, a history of PE is associated with low baseline cerebral blood velocity but an augmented response to a sympathoexcitatory stimulus. These changes in cerebral blood flow regulation may lead to an increased risk for cognitive impairment in women with a history of PE.
Impact of menopausal hormone formulations on pituitary-ovarian regulatory feedback
Kling, Juliana M. , Dowling, N. Maritza , Bimonte‐Nelson, Heather A. , Gleason, Carey E. , Kantarci, Kejal , Taylor, Hugh S. , Løbo, Rogerio A. , Cedars, Marcelle I. , Pal, Lubna , Neal‐Perry, Genevieve , Naftolin, Frederick , Harman, S. Mitchell , Miller, Virginia M. , Kantarci, Kejal , Kling, Juliana M , Manson, JoAnn E. , Brinton, Eliot A.

Mayo Clinic

American Journal of Physiology-Regulatory, Integrative and Comparative Physiology | October 30, 2019 | Volume: 317 | Issue: 6 | Pages: R912-R920

10.1152/ajpregu.00234.2019 | PMID 31663769 Get It

Changes in pituitary-ovarian hormones across the menopausal transition have multiple physiological consequences. However, little is known about how the major types of postmenopausal hormone therapy (HT) affect pituitary-ovarian hormonal relationships. This study evaluated these relationships in recently menopausal women (52.45 ± 2.49 yr of age) in the Kronos Early Estrogen Prevention Study (KEEPS) who were compliant to randomized, double-blinded treatment with oral conjugated equine estrogen (o-CEE; n = 109), transdermal 17β-estradiol (t-E2; n = 107), or placebo ( n = 146). Androstenedione, testosterone, 17β-estradiol, estrone, follicle-stimulating hormone (FSH), and luteinizing hormone (LH) were measured in serum before (baseline) and 48 mo after randomization to treatment. Descriptive summaries of hormone levels were performed, and multiple regression analyses were used to examine the effects of o-CEE, t-E2, and placebo on these hormone levels at 48 mo, adjusting for baseline levels. A network analysis examined the covariance of changes in hormone levels over the 48 mo within treatment groups. As expected, at 48 mo of treatment, hormone levels differed between women in the two active treatment groups compared with placebo, and network analysis indicated stronger relationships among hormone levels in the t-E2 and o-CEE groups compared with placebo. Associations among testosterone, 17β-estradiol, FSH, and LH differed between the o-CEE group compared with t-E2 and placebo groups. Thus, two common HT regimens differentially alter pituitary-ovarian hormone levels, altering feedback cycles and interhormonal associations in recently menopausal women. These interactions provide the basis for future studies investigating the impact of hormonal modulation of aging, including cognitive decline in women.
Sex, Survival, and Cardiomyopathy: Differences Between Men and Women With Hypertrophic Cardiomyopathy
Siontis, Konstantinos C. , Ommen, Steve R. , Geske, Jeffrey B. , Geske, Jeffrey B

Mayo Clinic

Journal of the American Heart Association | October 30, 2019 | Volume: 8 | Issue: 21 | Pages: No page available

10.1161/jaha.119.014448 | PMID 31663428 Get It

Small Diameter Xenogeneic Extracellular Matrix Scaffolds for Vascular Applications
Higuita, Manuela Lopera , Griffiths, Leigh G. , Lopera Higuita, Manuela, Griffiths, Leigh G

Mayo Clinic

Tissue Engineering Part B: Reviews | October 30, 2019 | Volume: 26 | Issue: 1 | Pages: 26-45

10.1089/ten.teb.2019.0229 | PMID 31663438 Get It

Currently, despite the success of percutaneous coronary intervention (PCI), coronary artery bypass graft (CABG) remains among the most commonly performed cardiac surgical procedures in the United States. Unfortunately, the use of autologous grafts in CABG presents a major clinical challenge as complications due to autologous vessel harvest and limited vessel availability pose a significant setback in the success rate of CABG surgeries. Acellular extracellular matrix (ECM) scaffolds derived from xenogeneic vascular tissues have the potential to overcome these challenges, as they offer unlimited availability and sufficient length to serve as “off-the-shelf” CABGs. Unfortunately, regardless of numerous efforts to produce a fully functional small diameter xenogeneic ECM scaffold, the combination of factors required to overcome all failure mechanisms in a single graft remains elusive. This article covers the major failure mechanisms of current xenogeneic small diameter vessel ECM scaffolds, and reviews the recent advances in the field to overcome these failure mechanisms and ultimately develop a small diameter ECM xenogeneic scaffold for CABG. Impact Statement Currently, the use of autologous vessel in coronary artery bypass graft (CABG) is common practice. However, the use of autologous tissue poses significant complications due to tissue harvest and limited availability. Developing an alternative vessel for use in CABG can potentially increase the success rate of CABG surgery by eliminating complications related to the use of autologous vessel. However, this development has been hindered by an array of failure mechanisms that currently have not been overcome. This article describes the currently identified failure mechanisms of small diameter vascular xenogeneic extracellular matrix scaffolds and reviews current research targeted to overcoming these failure mechanisms toward ensuring long-term graft patency.
Serratia marcescens shapes cutaneous bacterial communities and influences survival of an amphibian host
Madison, Joseph D. , Schmidt, Emme, Kerby, Jacob L., Ouellette, Scot P.

Mayo Clinic

Proceedings of the Royal Society B: Biological Sciences | October 30, 2019 | Volume: 286 | Issue: 1914 | Pages: 20191833

10.1098/rspb.2019.1833 | PMID 31662077 Get It

Ongoing investigations into the interactions between microbial communities and their associated hosts are changing how emerging diseases are perceived and ameliorated. Of the numerous host–microbiome–disease systems of study, the emergence of chytridiomycosis (caused by Batrachochytrium dendrobatidis , hereafter Bd ) has been implicated in ongoing declines and extinction events of amphibians worldwide. Interestingly, there has been differential survival among amphibians in resisting Bd infection and subsequent disease. One factor thought to contribute to this resistance is the host-associated cutaneous microbiota. This has raised the possibility of using genetically modified probiotics to restructure the host-associated microbiota for desired anti-fungal outcomes. Here, we use a previously described strain of Serratia marcescens ( Sm ) for the manipulation of amphibian cutaneous microbiota. Sm was genetically altered to have a dysfunctional pathway for the production of the extracellular metabolite prodigiosin. This genetically altered strain (Δ pig ) and the functional prodigiosin producing strain (wild-type, WT) were compared for their microbial community and anti- Bd effects both in vitro and in vivo . In vitro , Bd growth was significantly repressed in the presence of prodigiosin. In vivo , the inoculation of both Sm strains was shown to significantly influence amphibian microbiota diversity with the Δ pig-Sm treatment showing increasing alpha diversity, and the WT- Sm having no temporal effect on diversity. Differences were also seen in host mortality with Δ pig-Sm treatments exhibiting significantly decreased survival probability when compared with WT- Sm in the presence of Bd . These results are an important proof-of-concept for linking the use of genetically modified probiotic bacteria to host microbial community structure and disease outcomes, which in the future may provide a way to ameliorate disease and address critical frontiers in disease and microbial ecology.
More About USMLE Step 1 Scoring
Syed, Sabrina, Sykora, Daniel , Syed, Sabrina

Mayo Clinic

Academic Medicine | October 30, 2019 | Volume: 94 | Issue: 11 | Pages: 1626-1627

10.1097/acm.0000000000002926 | PMID 31663946 Get It

Courage in Medical Education: Cultivating Stories for Change
Sklar, David P. , Hafferty, Frederic W.

Mayo Clinic

Academic Medicine | October 30, 2019 | Volume: 94 | Issue: 11 | Pages: 1623-1625

10.1097/acm.0000000000002906 | PMID 31663943 Get It

Development and Validation of a Nomogram for Early Detection of Malignant Gallbladder Lesions
Chen, Mingyu , Cao, Jiasheng , Bai, Yang , Tong, Chenhao, Lin, Jian , Jindal, Vishal , Yang, Sherry X. , Pesce, Antonio , Panaro, Fabrizio , Ariche, Arié, Memeo, Riccardo , Bekaii‐Saab, Tanios , Cai, Xiujun , Group, Written on behalf of the AME Gallbladder Cancer Collaborative, Bekaii-Saab, Tanios S , Barchi, Leandro Cardoso , Nadalin, Silvio , Kai, Keita , Group, Written on behalf of the AME Gallbladder Cancer Collaborative, Memeo, Riccardo

Mayo Clinic

Clinical and Translational Gastroenterology | October 30, 2019 | Volume: 10 | Issue: 10 | Pages: e00098

10.14309/ctg.0000000000000098 | PMID 31663905 Get It

OBJECTIVES: Preoperative decision-making for differentiating malignant from benign lesions in the gallbladder remains challenging. We aimed to create a diagnostic nomogram to identify gallbladder cancer (GBC), especially for incidental GBC (IGBC), before surgical resection. METHODS: A total of 587 consecutive patients with pathologically confirmed gallbladder lesions from a hospital were randomly assigned to a training cohort (70%) and an internal validation cohort (30%), with 287 patients from other centers as an external validation cohort. Radiological features were developed by the least absolute shrinkage and selection operator logistic regression model. Significant radiological features and independent clinical factors, identified by multivariate analyses, were used to construct a nomogram. RESULTS: A diagnostic nomogram was established by age, CA19.9, and 6 radiological features. The values of area under the curve in the internal and external validation cohorts were up to 0.91 and 0.89, respectively. The calibration curves for probability of GBC showed optimal agreement between nomogram prediction and actual observation. Compared with previous methods, it demonstrated superior sensitivity (91.5%) and accuracy (85.1%) in the diagnosis of GBC. The accuracy using the nomogram was significantly higher in GBC groups compared with that by radiologists in the training cohort ( P < 0.001) and similarly in each cohort. Notably, most of the IGBC, which were misdiagnosed as benign lesions, were successfully identified using this nomogram. DISCUSSION: A novel nomogram provides a powerful tool for detecting the presence of cancer in gallbladder masses, with an increase in accuracy and sensitivity. It demonstrates an unprecedented potential for IGBC identification.