Citations

Showing 10 of 108162 citations.

Detection of cytomegalovirus DNA in sera of liver transplant recipients
Patel, Robin , Smith, Thomas F., Espy, Mark J., Wiesner, Russell H., Krom, Ruud A. F., Portela, Daniel, Paya, C. V., Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 32 | Issue: 6 | Pages: 1431-1434

10.1128/jcm.32.6.1431-1434.1994 | PMID 8077384 Get It

We prospectively studied the utility of the amplification of cytomegalovirus (CMV) DNA in the sera of liver transplant recipients in order to predict symptomatic CMV infection, thus enabling preemptive therapy with antiviral agents. Serum samples obtained at biweekly intervals from 20 sequential liver transplant recipients for at least 8 weeks following transplantation were tested by the PCR amplification procedure. Results were correlated with blood and urine cultures, histopathological findings from infected organs, and clinical manifestations. Six patients (30%) developed symptomatic CMV infection; in five (83%) of these patients, CMV DNA was detected prior to symptomatic CMV infection, and in one (17%) of these patients, CMV DNA was detected at the time of symptomatic CMV infection. CMV DNA was detected a mean of 13 days (range, 0 to 23 days) prior to the onset of symptomatic CMV infection. In addition, CMV DNA was detected in the sera of four of five patients with asymptomatic viremia and two patients with asymptomatic viruria. Lastly, the PCR was negative for sera from seven patients with no evidence of CMV infection. We found that PCR was able to detect the presence of CMV DNA in the sera of liver transplant recipients at a sensitivity of 92% and a specificity of 100% for CMV infection, while the sensitivity and specificity for symptomatic infection were 100 and 57%, respectively.
Dependence of polymerase chain reaction product inactivation protocols on amplicon length and sequence composition
Espy, Mark J., Smith, Thomas F., Persing, David H.

Mayo Clinic

Journal of Clinical Microbiology | January 5, 2020 | Volume: 31 | Issue: 9 | Pages: 2361-2365

10.1128/jcm.31.9.2361-2365.1993 | PMID 8408556 Get It

Specific diagnostic test results generated by polymerase chain reaction (PCR) depend upon control of amplicon contamination in the clinical laboratory. We compared photochemical (isopsoralen [IP]) and enzymatic (uracil N-glycosylase [UNG]) methods for their ability to prevent carryover of amplicons generated from genomic targets of five viruses. PCR products (amplicons) (herpes simplex virus, 342 bp; cytomegalovirus, 250 bp; Epstein-Barr virus, 240 bp) exposed to UV light in the presence of various concentrations of IP compound 10 (IP-10) resulted in apparent increased molecular sizes of the products, as indicated by migration patterns after gel electrophoresis, and were predictive of inactivation by the agent. For amplicons of < or = 100 bp, IP-10-induced electrophoretic shifts were related to the guanidine-cytidine (G + C) content of the PCR product; no apparent shift and no inactivation were observed for a 92-bp herpes simplex virus amplicon (G + C content, 65%), whereas the 100-bp human papillomavirus product (G + C content, 42%) showed a concentration-dependent shift (25 to 100 micrograms/ml) in electrophoretic migration and was partially inactivated. UNG effectively controlled amplicon carryover for target DNA of > or = 240 bp; however, this treatment did not inactivate the two amplicons of < or = 100 bp, regardless of the G + C content of the product. Larger products were inactivated efficiently by both methods, regardless of their G + C contents. We concluded that both IP and UNG effectively inactivated PCR amplicons but not short amplicons of < or = 100 bp. We recommend that with the adoption of PCR technology in clinical laboratories, primers should be designed to produce amplicons of at least 240 to 350 bp (depending on G + C content) and that at least one effective method of controlling carryover contamination should be incorporated into each PCR protocol.
Preventing false positives: quantitative evaluation of three protocols for inactivation of polymerase chain reaction amplification products
Rys, Paul N., Persing, D. H.

Mayo Clinic

Journal of Clinical Microbiology | January 5, 2020 | Volume: 31 | Issue: 9 | Pages: 2356-2360

10.1128/jcm.31.9.2356-2360.1993 | PMID 8408555 Get It

False-positive results because of carryover contamination by previously amplified nucleic acids are currently the greatest impediment to routine implementation of nucleic acid amplification protocols. We evaluated three methods for inactivation of a 156-bp Borrelia burgdorferi polymerase chain reaction (PCR) product: (i) post-PCR cross-linking with isopsoralen (IP), (ii) pre-PCR treatment of a dU-containing PCR product with uracil N-glycosylase (UNG), and (iii) post-PCR alkaline hydrolysis (primer hydrolysis) of PCR products synthesized by using primers containing 3' ribose residues. The sensitivities of the PCR performed under the conditions of each protocol were comparable. Inactivation of amplified DNA was highly efficient for all three protocols; the IP and UNG protocols eliminated at least to 3 x 10(9) copies of the product. The primer hydrolysis protocol varied in efficiency depending on the number and position of the 3' ribose residues, but inactivation ranged from 10(4) to 10(9) copies. We conclude that with some modifications, all three systems are effective for eliminating amplified DNA products. Routine implementation of at least one method should help to avoid false-positive results because of carryover contamination.
Evaluation of commercially available acridinium ester-labeled chemiluminescent DNA probes for culture identification of Blastomyces dermatitidis, Coccidioides immitis, Cryptococcus neoformans, and Histoplasma capsulatum
Stockman, L, Clark, Kristen , Hunt, John, Roberts, Glenn D., Hunt, J M

Mayo Clinic

Journal of Clinical Microbiology | January 5, 2020 | Volume: 31 | Issue: 4 | Pages: 845-850

10.1128/jcm.31.4.845-850.1993 | PMID 8463395 Get It

Four commercially available acridinium ester-labeled DNA probes directed against rRNA were evaluated for their ability to identify Blastomyces dermatitidis, Coccidioides immitis, Histoplasma capsulatum, and Cryptococcus neoformans in culture. rRNA was extracted by sonication of 1- to 2-mm2 portions of cultures of fungi in two chaotropic reagents with glass beads. Following a heat inactivation step, the extracts were hybridized in solution with probes specific for each pathogen. The acridinium ester reporter moiety of nonhybridized probe was selectively hydrolyzed, and chemiluminescence of specific DNA:RNA hybrids was quantitated in relative light units with a luminometer. A positive identification required a relative light unit value of > or = 50,000. Sensitivity and specificity of the probes were determined by probing cultures of the respective pathogenic fungi (target) and nontarget fungi. Both mycelial and yeast forms of the dimorphic fungi (B. dermatitidis and H. capsulatum) were tested. For B. dermatitidis, sensitivity and specificity were 87.8 and 100%, respectively (74 target and 219 nontarget fungi tested). For C. immitis, sensitivity and specificity were 99.2 and 100%, respectively (122 target and 164 nontarget fungi tested). For H. capsulatum, sensitivity and specificity were 100 and 100%, respectively (86 target and 154 nontarget fungi tested). For C. neoformans, sensitivity and specificity were 97 and 100%, respectively (100 target and 230 nontarget fungi tested). For B. dermatitidis, C. immitis, and C. neoformans, repeat testing increased the respective sensitivities to 97.3, 100, and 100%. The high sensitivities and specificities of the probes, the relatively short time (less than 1 h) required to perform the assay, and the availability of standardized reagent kits make the acridinium ester-labeled DNA probes well suited to laboratories in need of a rapid method to identify these fungal pathogens. Further, use of the probes to identify pathogenic fungi as soon as colonies appear on primary recovery media significantly shortens the time to reporting.
Evaluation of an enzyme-linked immunosorbent assay for detection of Cryptosporidium spp. in stool specimens
Rosenblatt, Jon E., Sloan, Lynne M.

Mayo Clinic

Journal of Clinical Microbiology | January 5, 2020 | Volume: 31 | Issue: 6 | Pages: 1468-1471

10.1128/jcm.31.6.1468-1471.1993 | PMID 8314988 Get It

We evaluated a commercially produced enzyme-linked immunosorbent assay (ELISA; LMD Laboratories, Inc.) for the detection of Cryptosporidium spp. in 296 stool specimens submitted to the Mayo Clinic parasitology laboratory for routine examination. The specimens examined were fresh (4 specimens), were stored frozen at -65 degrees C (49 specimens), or were preserved in 10% formalin (243 specimens). Results were compared with those obtained by indirect immunofluorescent antibody detection (Merifluor Cryptosporidium/Giardia; Meridian Diagnostics, Inc.). One hundred of the specimens were positive by indirect immunofluorescent antibody and ELISA, while 187 were negative by both methods; 91 of these negative stool samples contained 121 parasites of 17 different species. Eight ELISA false negatives and one false positive were observed. The ELISA sensitivity was 93%, specificity was 99%, and the positive predictive value was 99%. Storage of specimens preserved in 10% formalin or frozen fresh at -65 degrees C for up to 18 months did not appear to affect the results. There was no cross-reactivity with Giardia lamblia (54 negative specimens) or with the 16 other parasites present in the ELISA-negative stool samples. The ELISA is a fast, easy-to-read, and accurate method for the detection of Cryptosporidium spp. in stool specimens.
Comparison of commercial serological tests for detection of Helicobacter pylori antibodies
Kost, Louis J., Haddad, Andrea Paula Kafejian , Zinsmeister, Alan R., Talley, Nicholas J.

Mayo Clinic

Journal of Clinical Microbiology | January 5, 2020 | Volume: 30 | Issue: 12 | Pages: 3146-3150

10.1128/jcm.30.12.3146-3150.1992 | PMID 1452698 Get It

Serological testing for Helicobacter pylori infection is one of the diagnostic methods of choice. Various commercial kits that use different antigens have been developed, but data on their diagnostic accuracy and direct comparisons between the tests are lacking. We aimed to evaluate the sensitivity, specificity, and predictive value of three immunoglobulin G enzyme-linked immunosorbent assay kits: Pylori stat, Helico-G, and Premier H. pylori. Serum samples and gastric biopsy findings from 76 patients were evaluated. We found by using a priori cutoff values that the Pylori stat, Helico-G, and Premier kits had overall sensitivities of 96, 96, and 88%, respectively, and specificities of 94, 86, and 96%, respectively, compared with gastric biopsy findings. For 232 serum samples, the Pylori stat test and a previously validated standard serological assay on which the test was based disagreed in 3% of the cases, while for 76 samples that were tested, Helico-G and a previously validated standard assay on which it was based disagreed in 8% of the cases. The intra- and interassay precision of each of the test kits was high. We conclude that serology based on any of these commercial tests represents a reliable and valid method for the diagnosis of H. pylori whether or not highly purified antigens are used.
Bilophila wadsworthia bacteremia in two patients with hepatic abscesses
Kasten, Mary J. , Rosenblatt, Jon E., Gustafson, Daniel R.

Mayo Clinic

Journal of Clinical Microbiology | January 5, 2020 | Volume: 30 | Issue: 9 | Pages: 2502-2503

10.1128/jcm.30.9.2502-2503.1992 | PMID 1401025 Get It

Bilophila wadsworthia, a recently described anaerobic gram-negative bacillus, was isolated from blood cultures of two patients with liver abscesses. These isolates exhibited the expected phenotypic characteristics, and identification was confirmed by cell wall fatty acid analysis by gas-liquid chromatography. This is the first documentation of bacteremia due to B. wadsworthia.
Chemiluminescent universal probe for bacterial ribotyping
Gustaferro, C A, Persing, D. H.

Mayo Clinic

Journal of Clinical Microbiology | January 5, 2020 | Volume: 30 | Issue: 4 | Pages: 1039-1041

10.1128/jcm.30.4.1039-1041.1992 | PMID 1374074 Get It

We describe a novel procedure for direct covalent coupling of horseradish peroxidase to rRNA and ribotyping by using enhanced chemiluminescence. Compared with their 32P-end-labeled counterparts, chemiluminescent rRNA probes are stable and easy to synthesize and provide results as good as or superior to those obtained with isotopic labeling. Direct chemiluminescent labeling of Escherichia coli rRNA produces a sensitive, universal probe suitable for clinical laboratory use in the investigation of nosocomial outbreaks.
Comparison of shell vials and conventional tubes seeded with rhabdomyosarcoma and MRC-5 cells for the rapid detection of herpes simplex virus
Espy, Mark J., Wold, Arlo D., Jespersen, Deborah J., Jones, Mary F. , Smith, Thomas F.

Mayo Clinic

Journal of Clinical Microbiology | January 5, 2020 | Volume: 29 | Issue: 12 | Pages: 2701-2703

10.1128/jcm.29.12.2701-2703.1991 | PMID 1661744 Get It

Shell vials (SV) and conventional tubes (CT) were seeded with rhabdomyosarcoma (RD) and MRC-5 cells and inoculated with clinical specimens, and the systems were evaluated for the rapid diagnosis of herpes simplex virus (HSV) infections by detection of cytopathic effects (CPE) (for CT, for 7 days) and by using fluoresceinated monoclonal antibodies (for SV, 16 h postinoculation). Of 245 genital specimens (16 from males and 229 from females) 56 (23%) seeded with MRC-5 cells (14 type 1 and 42 type 2) and 55 (22%) seeded with RD cells were detected in CT; however, CPE were recognized in only 26 (46%) of the total HSV-positive cultures 1 day postinoculation. Forty-eight (86% sensitivity, MRC-5) and 46 (84% sensitivity, RD) HSV strains were detected immunologically in SV 16 h postinoculation. Early CPE in CT or fluorescent foci in SV were easier to detect in MRC-5 than in RD cell cultures. MRC-5 and RD cells were equally sensitive to infection with HSV. CT cell cultures were more sensitive than SV but less rapid for the detection of HSV infection (P less than 0.01). We recommend using SV for the rapid diagnosis of HSV infections, but in addition, CT must be inoculated with MRC-5 or RD to ensure maximum detection of this virus.
Serodiagnosis of Helicobacter pylori: comparison of enzyme-linked immunosorbent assays
Newell, D. G., Ormand, J. E., Carpenter, Herschel A., Wilson, Walter R., Zinsmeister, Alan R., Perez-Perez, G I, Talley, Nicholas J. , Perez-Perez, G I, Blaser, Martin J.

Mayo Clinic

Journal of Clinical Microbiology | January 5, 2020 | Volume: 29 | Issue: 8 | Pages: 1635-1639

10.1128/jcm.29.8.1635-1639.1991 | PMID 1761685 Get It

Enzyme-linked immunosorbent assays (ELISAs) have been developed to diagnose Helicobacter pylori infection. However, the methods are not standardized. We therefore prospectively evaluated the sensitivities and specificities of ELISAs developed in the United States and the United Kingdom in a study population comprising 41 consecutive symptomatic outpatients and 35 volunteers. At endoscopy, multiple biopsies were obtained for histology and culture and stained sections were graded for chronic gastritis, active chronic gastritis, and density of H. pylori. Serum samples were analyzed for H. pylori by ELISA. The first set of assays for immunoglobulin G (IgG) and IgA used a pool of sonicated isolates of H. pylori from five patients in the United States (antigen A). The second set of assays, developed in the United Kingdom, used three different antigens: antigen 1, an acid-extractable surface antigen; antigen 2, an acid-extractable antigen from an aflagellate variant; and antigen 3, a urease-containing fraction. Cutoff scores for positive results were determined a priori on the basis of previous serological studies. There was close agreement between histology and culture. In the study population, 36% of the individuals were H. pylori positive. The diagnostic value of the different ELISAs were highly comparable, and the crude antigens performed as well as the more purified antigens. The antigen A IgG had a sensitivity and specificity of 96 and 94%, respectively; the values for antigen 1 were 93 and 96%, respectively. The antigen A IgA and antigen 3 assays were the least sensitive tests.(ABSTRACT TRUNCATED AT 250 WORDS)