Citations

Showing 10 of 108162 citations.

Indeterminate results of the second-generation hepatitis C virus (HCV) recombinant immunoblot assay: significance of high-level c22-3 reactivity and influence of HCV genotypes
Zein, Nizar N., Germer, Jeffery J., Wendt, N K, SCHIMEK, CAROL M., Thorvilson, Jill N., Mitchell, P. Shawn, Persing, David H.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 1 | Pages: 311-312

10.1128/jcm.35.1.311-312.1997 | PMID 8968936 Get It

A second-generation recombinant immunoblot assay (RIBA 2.0) is used in the United States to confirm infection with hepatitis C virus (HCV) in samples that are anti-HCV (enzyme immunoassay) positive. In some cases, indeterminate results of RIBA 2.0, which are defined as reactivity to a single antigen species or reactivity limited to two proteins derived from the same coding region of the HCV genome, are encountered. This study was performed to establish the significance of indeterminate RIBA 2.0 results in relation to HCV RNA detection, high positivity for the c22-3 band, and the HCV genotype as determined by direct DNA sequencing. Ninety-six samples with indeterminate RIBA 2.0 results were studied. HCV RNA was detected in 21 of 34 (62%) samples with high reactivity to c22-3 and in 8 of 62 (13%) samples with low reactivity to c22-3. The HCV genotype distribution in samples that were RIBA 2.0 indeterminate and HCV RNA positive was significantly different from that in samples of a control group with positive results for both the RIBA 2.0 and HCV PCR. These results suggest that highly positive c22-3 samples are likely to be associated with HCV viremia and that infection with less common HCV genotypes is more commonly associated with indeterminate RIBA 2.0 results.
Borrelia burgdorferi enzyme-linked immunosorbent assay for discrimination of OspA vaccination from spirochete infection
Zhang, Y Q, Mathiesen, Dane A., Kolbert, C. P., Anderson, John F. , Schoen, Robert T. , Fikrig, Erol , Persing, David H.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 1 | Pages: 233-238

10.1128/jcm.35.1.233-238.1997 | PMID 8968914 Get It

Recombinant Lyme disease vaccines based on purified preparations of outer surface protein A (OspA) have been shown to be effective in preventing transmission of Borrelia burgdorferi in experimental animal models and are now being tested in humans. Since the most widely used screening tests for Lyme disease are based on a whole-cell sonicate of B. burgdorferi, serologic false positivity in vaccinated persons could result from reactivity to OspA within the antigen preparation. In order to avoid serologic false positivity in vaccinated subjects, we developed an immunoassay based on a low-passage-number, naturally occurring variant of B. burgdorferi which lacks the plasmid encoding OspA and OspB. The use of an antigen preparation derived from this organism provided sensitive and specific detection of B. burgdorferi seropositivity in experimental animals and in human Lyme disease cases. The OspA-B-negative enzyme-linked immunosorbent assay (ELISA) also appeared to be capable of discriminating the vaccinated state from vaccine failure and natural infection in experimental animals. Sera from human subjects participating in a vaccine trial gave false-positive results with an ELISA based on an OspA-containing strain, but no such reactivity was observed when the OspA-negative ELISA was used. We conclude that low-passage-number OspA-B-negative isolates in immunoassays may become useful for the immunologic discrimination of the vaccinated state, natural infection, and vaccine failure.
Assessment of routine use of an anaerobic bottle in a three-component, high-volume blood culture system
Hellinger, Walter C. , Cawley, John J., Alvarez, S., Hogan, Stephen F., Harmesen, W S, Ilstrup, D M, Cockerill, Franklin R.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 10 | Pages: 2544-2547

10.1128/jcm.34.10.2544-2547.1996 | PMID 8880517 Get It

The relative value of routine anaerobic blood culture for recovery of organisms and identification of episodes of bloodstream infection was assessed in a three-component, high-volume blood culture system which employs aerobic and anaerobic bottles of BacT/Alert (Organon-Teknika, Durham, N.C.) and aerobic cultures of Isolator (Wampole Laboratories, Cranbury, N.J.). The results of 5,595 blood culture sets from patients with suspected bloodstream infection were analyzed. Compared with either the aerobic BacT/Alert bottle or aerobic culture of Isolator, the BacT/Alert anaerobic bottle recovered significantly fewer isolates (242 versus 294, P < 0.05; 242 versus 298, P < 0.05) but did not detect significantly fewer episodes of bloodstream infection (141 versus 157, P > 0.05; 141 versus 147, P > 0.05). The BacT/Alert anaerobic bottle recovered significantly more isolates of obligately anaerobic bacteria (16 versus 4, P < 0.05; 16 versus 0, P < 0.05) and detected significantly more episodes of bloodstream infection caused by obligately anaerobic bacteria (10 versus 3, P < 0.05; 10 versus 0, P < 0.05) than either the aerobic bottle of BacT/Alert or the aerobic culture of Isolator. The combination of the BacT/Alert anaerobic bottle and the aerobic culture of Isolator recovered as may isolates (374 versus 377) and detected as many episodes of bloodstream infection (194 versus 191) as the combination of the aerobic bottle of BacT/Alert and the aerobic culture of Isolator, and both of these combinations identified at least 8% more isolates and detected at least 3% more bloodstream infections than the combination of the BacT/Alert aerobic and anaerobic bottles. Further analysis of the data revealed that the utility of the BacT/Alert anaerobic bottle, especially when combined with the aerobic culture of Isolator, resulted from not only enhanced recovery of obligately anaerobic bacteria but also effective recovery of facultatively anaerobic bacteria. These results demonstrate the utility of the anaerobic BacT/Alert bottle for detecting bloodstream infection caused by either facultatively anaerobic bacteria or obligately anaerobic bacteria and support the routine inclusion of anaerobic blood culture in the three-component blood culture system used in our hospital.
Clinical comparison of isolator, Septi-Chek, nonvented tryptic soy broth, and direct agar plating combined with thioglycolate broth for diagnosing spontaneous bacterial peritonitis
Hay, J. Eileen, Cockerill, Franklin R., Kaese, D, Vetter, Emily A., Wollan, Peter C. , Rakela, J., Wilhelm, Mark

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 34-37

10.1128/jcm.34.1.34-37.1996 | PMID 8748267 Get It

Spontaneous bacterial peritonitis is a life-threatening complication of cirrhotic ascites. Optimal patient management depends on the isolation of the causal organism from ascitic fluid. To evaluate culture techniques for the diagnosis of spontaneous bacterial peritonitis, we prospectively compared three blood culture system, the Isolator system, a lysis-centrifugation system, the Septi-Chek system, a biphasic culture system, and a nonvented tryptic soy broth system, all inoculated at the bedside, and our standard method of direct inoculation of specimens after transport to the laboratory onto agar plates and into thioglycolate broth. The results showed that the Septi-Chek and nonvented tryptic soy broth systems each recovered statistically significantly more pathogens than either the Isolator system (P = 0.0084) or the standard method (P = 0.00098). The Isolator system recovered more pathogens than the standard plate method, but this difference was not statistically significant. Both the Isolator system and the standard plate method recovered more contaminating microorganisms than the Septi-Chek or nonvented tryptic soy broth system. The Isolator system required the most processing time compared with the processing times required by any other method.
Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems
Cockerill, Franklin R., Torgerson, C A, Reed, G S, Vetter, Emily A., Weaver, Amy L. , Dale, J C, Roberts, Glenn D., Henry, Nancy K., Ilstrup, D M, Rosenblatt, Jon E.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 20-24

10.1128/jcm.34.1.20-24.1996 | PMID 8748264 Get It

The ESP 80A aerobic blood culture of the ESP automated blood culture system (Difco Laboratories. Detroit, Mich.) was compared with two manual aerobic blood culture systems, the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek (Becton Dickinson, Cockeysville, Md.) systems, for the detection of bloodstream microorganisms from 5,845 blood samples for culture collected from adult patients with suspected septicemia. The bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated onto solid medium and this medium was incubated for 72 h. A total of 609 microorganisms were recovered from 546 blood cultures. There was no statistically significant difference in the total recovery of microorganisms for the ESP 80A system when compared with that for the Septi-Chek system (P = 0.083); however, the Isolator system recovered significantly more microorganisms overall than either the ESP 80A (P < 0.001) or the Septi-Chek (P < 0.001) system. When assessing individual probable pathogens, the Isolator system detected statistically significantly more Staphylococcus aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). Similarly, the Isolator system detected statistically significantly more bloodstream infections (septic episodes) caused by S. aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). In blood culture sets which produced growth of the same probable pathogens in the ESP 80A and the Isolator systems, there was no statistically significant difference in the median times to detection for all pathogens combined (P = 0.067). However, a similar comparison showed the Isolator and the ESP 80A systems to have statistically significantly shorter median detection times for all pathogens combined (P < 0.001) when they were independently compared with the Septi-Chek system. The ESP 80A system had 29 (0.5%) false-positive signals. The ESP system required less processing time than the Isolator system and eliminates the hands-on time for the detection of positive cultures required by the manual systems.
Detection of the Staphylococcal mecA gene by chemiluminescent DNA hybridization
Kolbert, C. P., Connolly, J E, Lee, Myeong Jin, Persing, David H.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 8 | Pages: 2179-2182

10.1128/jcm.33.8.2179-2182.1995 | PMID 7559973 Get It

A new solution-phase DNA hybridization capture assay for the rapid detection of the mecA gene in clinical isolates of Staphylococcus was compared with multiplex PCR and disk diffusion methods. The assay uses a DNA capture probe immobilized on paramagnetic particles and a second DNA probe labeled with an acridinium ester. Bacteria from 24-h cultures are lysed, and the lysates are hybridized with the DNA probes. After magnetic separation to remove unhybridized labeled probe, the mecA gene is detected by the chemiluminescence of the hybridized probe. Four hundred consecutive staphylococcal isolates were assayed, including 147 S. aureus and 253 coagulase-negative Staphylococcus isolates. Among the S. aureus isolates, 14 of 147 were MecA+ by both the hybridization capture assay and PCR; 133 of 147 were MecA negative by both assays (positive and negative predictive values, 100%). Comparison of disk diffusion results with those obtained by genotypic methods indicated that 14 of 147 S. aureus isolates judged to be resistant were positive by both methods; 119 of 147 were Oxs and negative by both genotypic methods (positive and negative predictive values, 50 and 100%, respectively). The remaining 14 S. aureus isolates were MecA- Oxr; among these, 13 were beta-lactamase hyperproducers. For coagulase-negative staphylococci, 130 of 253 were MecA+ by the hybridization capture assay; 129 of 130 of these isolates were positive by PCR (positive and negative predictive values, 99.2 and 100%, respectively). Comparison with the disk diffusion assay showed that 128 of the coagulase-negative MecA+ isolates were Oxr; 111 of 253 were MecA- and Oxs (positive and negative predictive values, 90.8 and 99.1%, respectively). Thirteen coagulase-negative isolates were MecA-Oxr; among these, three were beta-lactamase hyperproducers. Comparison of the hybridization capture assay results with PCR indicates that the DNA hybridization assay is a sensitive and specific test for the detection of the mecA gene in clinical isolates of Staphylococcus.
Clinical comparison of the isolator and BacT/Alert aerobic blood culture systems
Hellinger, Walter C. , Cawley, John J., Alvarez, S., Hogan, Stephen F., Harmsen, William S. , Ilstrup, D M, Cockerill, Franklin R.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 7 | Pages: 1787-1790

10.1128/jcm.33.7.1787-1790.1995 | PMID 7665647 Get It

The performance characteristics of the Isolator (Wampole Laboratories, Cranbury, N.J.) and the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) aerobic blood culture systems were compared for 6,009 blood culture sets obtained from patients with suspected bloodstream infections. The BacT/Alert aerobic bottle [BTA(O2)] was continuously agitated while it was incubated in 5% CO2 at 36 degrees C; culture plates prepared from the Isolator tube [I(O2)] were incubated in 5% CO2 at 37 degrees C. From 394 blood cultures, 416 clinically significant isolates of bacteria and yeasts were recovered. The overall yields for BTA(O2) and I(O2) were not significantly different (319 versus 336; P = 0.20). I(O2) recovered significantly more staphylococcus (P < 0.05) and yeast isolates (P < 0.01). BTA(O2) recovered significantly more aerobic and facultatively anaerobic gram-negative bacilli (P < 0.05). In blood culture sets which produced growth of the same organisms in both the BTA(O2) and I(O2) systems, the BTA(O2) system detected growth sooner, but more rapid identification was possible with the I(O2) system by virtue of earlier isolation of colonies on solid media.
Genotypic detection of Mycobacterium tuberculosis rifampin resistance: comparison of single-strand conformation polymorphism and dideoxy fingerprinting
Felmlee, Teresa A., Liu, Q, Whelen, A. Christian , Williams, David E. , Sommer, Steve S., Persing, David H.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 6 | Pages: 1617-1623

10.1128/jcm.33.6.1617-1623.1995 | PMID 7650198 Get It

Detection of mutations in the rpoB gene of Mycobacterium tuberculosis can be used as an accurate predictor of rifampin resistance in the majority of strains tested. Simple but highly accurate screening methods must be developed for the detection of these mutations. Either DNA sequence analysis or single-strand conformation polymorphism (SSCP) screening can be used to detect rpoB mutations, but these techniques either are expensive or yield results that may prove difficult to interpret when used in a clinical setting. This report describes the use of dideoxy fingerprinting (ddF) as a postamplification screening method to identify rifampin-resistant genotypes. The ddF protocol was performed on the amplified rpoB fragment with no preparatory steps, thus making ddF practical for laboratories equipped for polyacrylamide gel electrophoresis. When compared with the results of SSCP analysis, ddF results were more easily interpreted and contained more sequence-dependent information that facilitated differentiation of functionally significant and silent mutations. The ddF method was used for genotypic determination of rifampin susceptibility of 20 multidrug-resistant strains of M. tuberculosis. The results of this analysis were concordant with DNA sequence analysis and conventional clinical laboratory methods.
Direct genotypic detection of Mycobacterium tuberculosis rifampin resistance in clinical specimens by using single-tube heminested PCR
Whelen, A. Christian , Felmlee, Teresa A., Hunt, John, Williams, Diana L., Roberts, Glenn D., Stockman, L, Persing, David H., Hunt, J M

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 3 | Pages: 556-561

10.1128/jcm.33.3.556-561.1995 | PMID 7751357 Get It

Recent analysis of the gene encoding the beta subunit of Mycobacterium tuberculosis RNA polymerase (rpoB) has demonstrated a small region that harbors the mutations most frequently associated with rifampin resistance. Earlier reports have described a high degree of sequence conservation of rpoB among mycobacteria other than M. tuberculosis and other GC-rich bacteria that can lead to false-positive amplification when applied directly to clinical specimens. We developed reagents for PCR amplification that are based on signature nucleotides discovered by comparative sequence analysis of the rpoB genes of organisms phylogenetically related to M. tuberculosis. The specificities of the reagents were challenged with 20 isolates of multiple-drug-resistant M. tuberculosis and more than 20 species of mycobacteria other than M. tuberculosis and other GC-rich organisms. A single-tube heminested PCR protocol was devised to obtain sensitivity equal to those of an IS6110-based PCR assay and culture in spiked sputum experiments. The assay correctly identified 21 of 24 (87.5%) culture-positive specimens, 13 of which were acid-fast smear-negative, in a panel of 51 clinical specimens. Three specimens that were false-positive initially were negative upon repeat testing when the assay was modified to eliminate the potential for aerosol carryover of the first-round amplification product during the open-tube addition of the second set of reaction reagents. This assay is the most sensitive and specific test to date for the direct detection of M. tuberculosis rpoB in clinical specimens. This rapid PCR-based assay can be used for the simultaneous identification of M. tuberculosis and its rifampin susceptibility genotype.
Evaluation of enzyme-linked immunoassay for serological diagnosis of cysticercosis
Sloan, Lynne M., Schneider, Susan K., Rosenblatt, Jon E.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 12 | Pages: 3124-3128

10.1128/jcm.33.12.3124-3128.1995 | PMID 8586686 Get It

We evaluated a commercially available enzyme-linked immunoassay (ELISA) from LMD Laboratories, Inc., Carlsbad, Calif., for the detection of antibodies in serum to the cysticercus of Taenia solium. The ELISA was performed on 308 serum samples; 198 from a pool of healthy individuals, 42 from patients who had antibodies against a variety of parasites other than T. solium, and 68 from patients suspected of having cysticercosis. All of these 68 specimens were tested both by the ELISA and by an immunoblot method (enzyme-linked immunoelectrotransfer blot assay [EITB]) developed at the Parasitic Serology Laboratory of the Centers for Disease Control and Prevention. Twenty-seven of the 68 serum samples from patients suspected of having cysticercosis were positive by both EITB and ELISA, while 31 were negative by both assays. ELISA results for three and two samples were considered false positive and false negative, respectively, when compared with the results of EITB. Results for an additional five samples were considered equivocal but were technically positive because their optical density readings were slightly above the cutoff value. Three of the 198 serum samples from the bank of serum samples from healthy individuals were also false positive by ELISA (the EITB result for the samples was negative). Six other serum samples from healthy individuals which had equivocal results and the five serum samples from patients with equivocal results were EITB negative. Serum samples containing antibodies against Echinococcus spp. frequently cross-reacted with the cysticercus ELISA antigen (13 of 16 specimens), but serum samples with antibodies against other parasites did not (2 of 26 specimens); all of these serum samples were EITB negative. The commercially available ELISA that we describe is a simple and rapid test. Considering all 308 specimens, the ELISA had a specificity of 93% (when samples with equivocal results were considered negative) or 89% (when samples with equivocal results were considered positive); the sensitivity was 93%.