Methods for Measuring Plasma Hemoglobin in Micromolar Concentration Compared
Fairbanks, Virgil F., Ziesmer, Steven C., O’Brien, Peter C.

Mayo Clinic

Clinical Chemistry | January 13, 2020 | Volume: 38 | Issue: 1 | Pages: 132-140

10.1093/clinchem/38.1.132 Get It

Abstract Of eight methods examined for measuring plasma hemoglobin in micromolar concentration, all exhibited acceptable linearity, reproducibility, and concurrence except when specimens were icteric or lipemic or contained methemoglobin or methemalbumin. Measurement of absorbance at 578 nm with an Allen correction permits precise assay of plasma oxyhemoglobin concentration as low as 0.01 g/L (1 mg/dL, 0.16 mumol/L), unaffected by hyperlipidemia or hyperbilirubinemia. Discrepancies between methods occurred in 11.6% of a consecutive series of 50 nonicteric patients' plasma specimens. Examination of absorption spectra is helpful when discrepancies are observed between methods. The presence of methemalbumin or methemoglobin in plasma is not recognized by methods that measure only oxyhemoglobin. Increased ceruloplasmin or beta-carotene does not significantly affect results.
American Thyroid Association assessment of current free thyroid hormone and thyrotropin measurements and guidelines for future clinical assays. The Committee on Nomenclature of the American Thyroid Association
Bayer, Monika, Kaplan, M, Klee, George G., Larsen, P R, Spencer, Carole A. , Hay, Ian

Mayo Clinic

Clinical Chemistry | January 13, 2020 | Volume: 37 | Issue: 11 | Pages: 2002-2008

10.1093/clinchem/37.11.2002 Get It

Total arsenic in urine: palladium-persulfate vs nickel as a matrix modifier for graphite furnace atomic absorption spectrophotometry
Nixon, David E., Mussmann, G V, Eckdahl, Steven J., Moyer, Thomas P.

Mayo Clinic

Clinical Chemistry | January 13, 2020 | Volume: 37 | Issue: 9 | Pages: 1575-1579

10.1093/clinchem/37.9.1575 Get It

Abstract We evaluated the effectiveness of nickel and palladium with or without added potassium persulfate as matrix modifiers for the determination of total arsenic in urine. Complete recovery of pure aqueous solutions of As(III), As(V), cacodylic acid (DMA), monomethylarsinic acid (MMA), and o-arsanilic acid was attained by using both nickel and palladium modifiers. Combined arsenobetaine and arsenocholine (so-called fish arsenic), extracted from a certified control material of dogfish muscle (DORM-1), were completely recovered with Pd-S2O8 matrix modification, but not with nickel. Excellent agreement with target values for arsenic in urines from the Centre de Toxicologie du Quebec, supplied by the Interlaboratory Comparison Program, was attained irrespective of the arsenic source when we used Pd-S2O8 as the matrix modifier.
Modified enzyme-based colorimetric assay of urinary and plasma oxalate with improved sensitivity and no ascorbate interference: reference values and sample handling procedures
Wilson, David M. , Liedtke, Robert R.

Mayo Clinic

Clinical Chemistry | January 13, 2020 | Volume: 37 | Issue: 7 | Pages: 1229-1235

10.1093/clinchem/37.7.1229 Get It

Abstract The measurement of oxalate in urine and plasma continues to be difficult, particularly in the presence of ascorbate. We have modified and validated a colorimetric assay involving the use of oxalate oxidase (EC 1.2.3.4). Modification of an HPLC spectrophotometric detector improved sensitivity (to as much as 1000-fold that of conventional spectrophotometers) and allowed measurement of oxalate concentrations less than 1 mumol/L. This provided more than enough sensitivity for measurement of normal concentrations of plasma oxalate. We established reference values for oxalate concentrations in urine and plasma, studied sample handling, and established conditions to avoid ascorbate interference in urine and plasma measurements. Mean analytical recovery of [14C]oxalate from plasma to the filtrate was 86 (SD 10)%; recovery of unlabeled oxalate from filtrate was 87 (SD 9)%. Urinary oxalate excretion rates in apparently healthy controls were 0.11-0.46 mmol/24 h. Plasma concentrations in control subjects were 2.5 (SD 0.7) mumol/L, similar to concentrations determined by recent gas chromatographic and isotope dilution methods. Frozen and acidified urine samples showed no interference from ascorbate when excess ascorbate was avoided. Ingestion of 2 g of ascorbate daily did not increase urinary oxalate in healthy control subjects, but during storage ascorbate was converted to oxalate in all conditions tested.
Quantifying bone and liver alkaline phosphatase by the resolution of two-component inactivation data obtained with a centrifugal analyzer
Forsman, Rodney W, O’Brien, John F.

Mayo Clinic

Clinical Chemistry | January 13, 2020 | Volume: 37 | Issue: 3 | Pages: 347-350

10.1093/clinchem/37.3.347 Get It

Abstract In this method we use a linear equation to resolve two-component decay data from the urea inactivation of mixtures of alkaline phosphatase (EC 3.1.3.1) of liver and bone origin. The specificity for the bone/liver isoenzyme is enhanced by including L-phenylalanine in the urea reaction to inhibit the intestinal and placental forms. Bone and liver fractions are each quantified from results of a single run on the centrifugal analyzer. Total activity and the L-phenylalanine-inhibited fraction are measured on separate runs. A simplification of this method has been used in our laboratory for 14 years in performing greater than 80,000 analyses of clinical specimens. Speed, accuracy, and precision are improved over previous methods by this mathematical solution. Data reduction is automated through the use of a personal computer interfaced to the analyzer. With such systems generally available, this method can now be suggested as suitable for routine use to separate these and perhaps other isoenzyme mixtures.
Tolerance limits for short-term analytical bias and analytical imprecision derived from clinical assay specificity
Klee, George G.

Mayo Clinic

Clinical Chemistry | January 13, 2020 | Volume: 39 | Issue: 7 | Pages: 1514-1518

10.1093/clinchem/39.7.1514 Get It

Abstract I propose a method for defining tolerance limits for assay bias and assay imprecision, based on the effects of these tolerance limits on the clinical specificity of the assay. An analytical "error budget" is defined as the squared sums of the imprecision and bias errors. The maximum limit for this error budget is set at a value corresponding to a 50% increase in the false-positive rate for classifying healthy subjects. For gaussian distributions with +/- 2 SD used as decision limits, this error budget equates to 0.45 SD of combined within-person and between-person biological variation (SDBiol). To provide reasonable power for bias detection in an assay, I recommend that the SD of the assay be kept at less than half the bias limit. Then, for the gaussian distribution, the maximum bias limit should be < 0.36 SDBiol and the SD of the assay should be < 0.18 SDBiol. Procedures are provided for using the same principles to define tolerance limits for decision limits other than +/- 2 SD and for nongaussian distributions.
Immune Checkpoint Axes Are Dysregulated in Patients With Alcoholic Hepatitis
Li, Wei , Xia, Ying , Yang, Jing , Guo, Haitao , Sun, Guoqing, Shah, Vijay H. , Lou, Yongliang , Zheng, Xiaoqun , Chalasani, Naga , Yu, Qigui , Shah, Vijay H , Li, Wei , Sanyal, Arun J.

Mayo Clinic

Hepatology Communications | January 13, 2020 | Volume: 4 | Issue: 4 | Pages: 588-605

10.1002/hep4.1475 | PMID 32258953 Get It

Alcoholic hepatitis (AH) is a severe inflammatory liver disease that develops in some heavy drinkers. The immune system in patients with AH is hyperactive and yet dysfunctional. Here, we investigated whether this immune‐dysregulated state is related to the alcoholic impact on immune checkpoints (ICPs). We used multiplex immunoassays and enzyme‐linked immunosorbent assay to quantify plasma levels of 18 soluble ICPs (sICPs) from 81 patients with AH, 65 heavy drinkers without liver diseases (HDCs), and 39 healthy controls (HCs) at baseline, 33 patients with AH and 32 HDCs at 6‐month follow‐up, and 18 patients with AH and 29 HDCs at 12‐month follow‐up. We demonstrated that baseline levels of 6 sICPs (soluble T‐cell immunoglobulin and mucin domain 3 [sTIM‐3], soluble cluster of differentiation [sCD]27, sCD40, soluble Toll‐like receptor‐2 [sTLR‐2], soluble herpesvirus entry mediator [sHVEM], and soluble lymphotoxin‐like inducible protein that competes with glycoprotein D for herpes virus entry on T cells [sLIGHT]) were up‐regulated, while 11 sICPs (soluble B‐ and T‐lymphocyte attenuator [sBTLA], sCD160, soluble cytotoxic T‐lymphocyte‐associated protein 4 [sCTLA‐4], soluble lymphocyte‐activation gene 3 [sLAG‐3], soluble programmed death 1 [sPD‐1], sPD ligand 1 [sPD‐L1], sCD28, soluble glucocorticoid‐induced tumor necrosis factor receptor‐related protein [sGITR], sGITR ligand [sGITRL], sCD80, and inducible T‐cell costimulator [sICOS]) were down‐regulated in patients with AH compared to HDCs. The up‐regulated sICPs except sLIGHT and down‐regulated sCD80, sCD160, sCTLA‐4, and sLAG‐3 correlated positively or negatively with AH disease severity, bacterial translocation, and inflammatory factors. At follow‐up, abstinent patients with AH still had higher levels of several sICPs compared to HDCs. We also compared expression of 10 membrane‐bound ICPs (mICPs) on peripheral blood mononuclear cells (PBMCs) from patients with AH and HCs by flow cytometry and found that several mICPs were dysregulated on blood cells from patients with AH. The function and regulation of sICPs and mICPs were studied using PBMCs from patients with AH and HCs. Recombinant sHVEM affected tumor necrosis factor (TNF)‐α and interferon‐γ production by T cells from patients with AH and HCs. Conclusion: Both sICPs and mICPs were dysregulated in patients with AH, and alcohol abstinence did not fully reverse these abnormalities. The HVEM axis plays a role in regulating T‐cell function in patients with AH.
Protein Purification: Principles, High Resolution Methods, and Applications. Jan-Christer Janson, Lars Ryder, eds. New York: VCH Publishers, 1989, 512 pp, $65 in U.S. ISBN 0-89573-122-3
Landers, Jane, Madden, Benjamin J.

Mayo Clinic

Clinical Chemistry | January 13, 2020 | Volume: 38 | Issue: 3 | Pages: 447-447

10.1093/clinchem/38.3.447 Get It

Multisite Immunochemiluminometric Assay for Simultaneously Measuring Whole-Molecule and Amino-Terminal Fragments of Human Parathyrin
Klee, George G., Preissner, Carol M., Schryver, Patricia G., Taylor, R L, Kao, Pei-Chun

Mayo Clinic

Clinical Chemistry | January 13, 2020 | Volume: 38 | Issue: 5 | Pages: 628-635

10.1093/clinchem/38.5.628 Get It

Abstract The immunochemiluminometric assay described uses immobilized anti-human parathyrin (parathyroid hormone, hPTH)(1-44) and anti-hPTH(44-68) antisera and acridinium ester-labeled anti-hPTH(1-34) to simultaneously measure both intact hPTH and its amino-terminal fragments. Results by the assay correlate well with those by a cAMP-based bioassay and the Nichols Allegro immunoradiometric assay. The minimal detection limit is 0.08 pmol/L. The normal range is 1.0-5.0 pmol/L, and values are higher in older women. About 90% of study patients with surgically proven parathyroid adenomas had above-normal preoperative PTH concentrations, whereas patients with hypercalcemia of malignancy had normal or suppressed values. This assay was designed to detect both intact PTH and amino-terminal PTH fragments; however, chromatographic fractionation of pools of primary and secondary hyperparathyroid plasma showed virtually no amino-terminal fragment activity. Nonetheless, the design is important because the absence of carboxyl-terminal binding sites prevents interference by carboxyl-terminal fragments and because bioactive amino-terminal fragments will react in the assay if they are present in the patients' sera or if they are produced by in vitro proteolysis of intact PTH.
Blood-collection device for trace and ultra-trace metal specimens evaluated
Moyer, Thomas P. , Mussmann, G V, Nixon, David E.

Mayo Clinic

Clinical Chemistry | January 13, 2020 | Volume: 37 | Issue: 5 | Pages: 709-714

10.1093/clinchem/37.5.709 Get It

Abstract We evaluated the evacuated phlebotomy tube designed specifically for trace metal analysis by Sherwood Medical Co. Pools of human serum containing known concentrations of aluminum, arsenic, calcium, cadmium, copper, chromium, iron, lead, magnesium, manganese, mercury, selenium, and zinc were exposed to the tube and rubber stopper for defined periods ranging from 5 min to 24 h. Analysis for each element was performed in a randomized fashion under rigidly controlled conditions by use of standard electrothermal atomization atomic absorption spectroscopy, inductively coupled plasma atomic emission spectroscopy, and cold vapor atomic absorption spectrometry. In addition, for comparative purposes, we collected blood samples from normal volunteers by use of ultra-clean polystyrene phlebotomy syringes as well as standard evacuated phlebotomy tubes. We conclude that, except for lead, there was no significant contribution of any trace element studied from the evaluated tube and stopper to the serum. Because whole blood is the usual specimen for lead testing, the observation of a trace amount of lead in this tube designed for serum collection is trivial.