Detection of Interrupted Bubble Flow in the Technicon Automated Immunoprecipitin System
Hansen, Robert J., Tschida, Anthony R., Markowitz, Harold

Mayo Clinic

Clinical Chemistry | January 21, 2020 | Volume: 18 | Issue: 7 | Pages: 677-678

10.1093/clinchem/18.7.677 Get It

Abstract A simple unit is described for detecting interrupted flow in an automated immunoprecipitin system. The principle involved is conductivity change resulting from interruption of bubble flow.
High-Resolution Chromatographic System for Measuring Organic Acids in Biological Samples
Rosevear, John W., Pfaff, Kenneth J, Moffitt, Emerson A.

Mayo Clinic

Clinical Chemistry | January 21, 2020 | Volume: 17 | Issue: 8 | Pages: 721-730

10.1093/clinchem/17.8.721 Get It

Abstract A chromatographic system for organic acids has been developed, with improved stability, resolution, and sensitivity for measuring organic anions in biological samples. A calibration mixture containing 100 nEq each of 18 organic anions was clearly resolved, with a signal-to-noise ratio greater than 100:1. The baseline was essentially flat throughout the chromatogram. With scale expansion, the sensitivity limit was about 0.2 nEq per constituent. The width of each peak at half its height was 1 to 2% of its retention time. The system could thus resolve 50 or more constituents. In chromatograms of whole blood and urine more than 40 compounds are resolved. The system is basically a liquid-liquid partition between an acidified aqueous phase on silicic acid and a gradient of nonpolar and polar solvents. Eluted organic acids are detected photometrically by mixing the column effluent with a miscible solvent containing a suitable indicator. Samples require about 6 h for complete chromatography at present.
Glucose Oxidase Method for Continuous Automated Blood Glucose Determination
Rosevear, John W., Pfaff, Kenneth J, SERVICE, FREDERICK J., Molnar, George D., Ackerman, Eugene

Mayo Clinic

Clinical Chemistry | January 21, 2020 | Volume: 15 | Issue: 8 | Pages: 680-698

10.1093/clinchem/15.8.680 Get It

Abstract A glucose oxidase-peroxidase method for continuous automated monitoring of blood glucose has been developed. The response is linear over the range 0-800 mg/100 ml. Sensitivity can be maintained for 24 hr or longer and can be restored by rinsing the analytic system with sulfuric acid to permit studies of longer than 48 hr in duration. A precision of ± 1% can be maintained between rinses for samples containing 100-600 mg of glucose per 100 ml. This method is satisfactorily specific for glucose: The response with other sugars is less than 1% of the response obtained with the same concentration of glucose. Ascorbic acid causes no significant inhibition of the response to glucose. The inhibition by uric acid has been reduced fifty-fold compared to that in other methods. Transit through the sampling catheter and analytic system requires 15 min. Timed from the first detectable response to a change in concentration, 25% of total response is achieved in 30 sec and 90% in 80 sec. Fifty percent of an oscillation with a half-period of 45 sec can be detected; no oscillations this short were observed in records of human blood glucose. Applicability and feasibility of this method have been demonstrated in over 2000 hr of repeated blood glucose recordings in 12 diabetic and 6 normal subjects.
Waldenstrom's macroglobulinemia in the era of immunotherapy
Vaxman, Iuliana , Gertz, Morie A. , Gertz, Morie A , Vaxman, Iuliana

Mayo Clinic

Leukemia & Lymphoma | January 21, 2020 | Volume: 61 | Issue: 6 | Pages: 1292-1304

10.1080/10428194.2020.1711901 | PMID 31960730 Get It

Implication of Creatinine and Gut Flora in the Uremic Syndrome: Induction of "Creatininase" in Colon Contents of the Rat by Dietary Creatinine
Jones, James D., Burnett, Philip

Mayo Clinic

Clinical Chemistry | January 21, 2020 | Volume: 18 | Issue: 3 | Pages: 280-284

10.1093/clinchem/18.3.280 Get It

Abstract "Creatininase" activity was induced in the colon flora of rats by feeding creatinine. Sarcosine and methylamine were tentatively identified as the major products of the enzymic action. A third (unidentified) compound was observed. These compounds and methylguanidine were labeled in the urine of rats given 14CH3-creatinine orally. The results suggest that creatinine should not be considered biologically inert in animals, especially in those with decreased renal function.
Responsiveness of a Balance Assessment Using a Mobile Application
Anderson, Sarah , Campbell, Graeme R., Davis, Samson J., Tindall, Samuel W., Anderson, Sarah E, Krause, David A. , Anderson, Sarah E., Hollman, John H.

Mayo Clinic

Sports Health: A Multidisciplinary Approach | January 21, 2020 | Volume: 12 | Issue: 4 | Pages: 401-404

10.1177/1941738119888656 | PMID 31961240 Get It

Background: Balance assessment is used by clinicians as part of athlete concussion screening. The King-Devick (K-D) Balance app is designed to provide an objective balance assessment value. The purpose of this study was to investigate the responsiveness of a balance assessment using the K-D Balance app. Hypothesis: The K-D Balance app will demonstrate acceptable responsiveness for balance assessment. Study Design: Repeated-measures study. Level of Evidence: Level 5. Methods: A convenience sample of 25 participants between the ages of 20 and 25 years completed testing procedures. A battery of balance tests using the K-D Balance app on an iPhone were conducted 1 week apart. After a 5-minute warm-up, 3 stances were assessed: double leg, tandem right, and tandem left. The K-D Balance app guided the test positions and test times. A value representing movement was generated by the app algorithm. Analysis included descriptive statistics along with intraclass correlation coefficient and minimal detectable change (MDC). Results: The median score of the K-D test was 0.5 for session 1 and 0.4 for session 2. The ICC was 0.42 (95% CI, 0.04-0.70), and the MDC was 1.58. Conclusion: The MDC value of 1.58 represents the threshold of meaningful change in balance, as measured with the K-D Balance app. Clinical Relevance: Clinicians can use the results of this study to objectively assess changes in balance over time using the K-D Balance app.
Comparison of Improved Fluorometric Methods Used to Quantitate Plasma Catecholamines
Manger, William M., Steinsland, O. S., Nahas, Gabriel G. , Wakim, Khalil G., Dufton, S.

Mayo Clinic

Clinical Chemistry | January 21, 2020 | Volume: 15 | Issue: 12 | Pages: 1101-1123

10.1093/clinchem/15.12.1101 Get It

Abstract Comparative studies reveal that the ethylenediamine and the trihydroxyindole method when employed as suggested are suitable for assessing sympatho-adrenal activation under various stressful conditions that are accompanied by release of catecholamines into the circulation. Both methods are very accurate in quantitating epinephrine or norepinephrine that has been added to plasma or whole blood, although recovery from blood is less, owing mainly to some association of catecholamines with formed elements, primarily erythrocytes. Use of sodium thiosulfate in the ethylenediamine procedure minimizes association of catecholamines with formed elements. If blood samples are cooled in ice water when collected, association of catecholamines with blood cells can be further reduced. In the trihydroxyindole method, unless tubes containing blood samples are immediately immersed in ice water, a significant amount of catecholamines will disappear from plasma, because of this association of catecholamines with cells.
Regulation of Plasma Creatinine Concentration by Use of a Servo Control System
Harvey, Rodney B., Bassingthwaighte, James B. , Heppner, Richard L.

Mayo Clinic

Clinical Chemistry | January 21, 2020 | Volume: 14 | Issue: 10 | Pages: 944-959

10.1093/clinchem/14.10.944 Get It

Abstract A method for controlling the plasma creatinine concentration is described. This method uses continuous determination of the plasma creatinine concentration and a servomechanism which drives an infusion pump at a rate proportional to the difference between the actual and desired creatinine concentrations. The rate and volume of creatinine infusion necessary to maintain the desired plasma concentration provide information related to kidney function and the accumulation of creatinine in the body. Experiments using this technic and the method of data analysis are described. It has been shown that under certain conditions this technic may be used to estimate the renal clearance of creatinine and the size and nature of the space into which creatinine is distributed in the dog.