Citations

Clear

6423 citation(s) found for "Su, Christopher".

Fish oil and neurovascular control in humans
Carter, Jason R. , Schwartz, Christopher E., Yang, Huan , Joyner, Michael J. , Carter, Jason R

Mayo Clinic

American Journal of Physiology-Heart and Circulatory Physiology | June 17, 2012 | Volume: 303 | Issue: 4 | Pages: H450-H456

10.1152/ajpheart.00353.2012 | PMID 22707560 Get It

The antihypertensive influence of fish oil is controversial, and the mechanisms remain unclear. Because the inverse relation between fish oil and hypertension appears to be partially dependent on the degree of hypertension, we tested the hypothesis that fish oil would elicit more dramatic reductions in mean arterial pressure (MAP) and muscle sympathetic nerve activity (MSNA) in prehypertensive (PHT) compared with normotensive (NT) subjects. Resting MAP, MSNA, and heart rate (HR) were examined before and after 8 wk of fish oil (9 g/day; 1.6 g eicosapentaenoic acid and 1.1 g docosahexaenoic acid) or placebo (olive oil; 9 g/day) in 38 NT (19 fish oil; 19 placebo) and 29 PHT (15 fish oil; 14 placebo) volunteers. Fish oil did not alter resting MAP, MSNA, or HR in either NT (80 ± 1 to 80 ± 1 mmHg; 11 ± 2 to 10 ± 1 bursts/min; 71 ± 2 to 71 ± 2 beats/min) or PHT (88 ± 2 to 87 ± 1 mmHg; 11 ± 2 to 10 ± 2 bursts/min; 73 ± 2 to 73 ± 2 beats/min) subjects. When NT and PHT groups were consolidated, analysis of covariance confirmed that pretreatment resting MAP was not associated with changes in MSNA after fish oil. In contrast, pretreatment resting HR was correlated with changes in MSNA ( r = 0.47; P = 0.007) and MAP ( r = 0.42; P < 0.007) after fish oil but not placebo. In conclusion, fish oil did not alter sympathetic neural control in NT or PHT subjects. However, our findings suggest that fish oil is associated with modest sympathoinhibition in individuals with higher resting heart rates, a finding that is consistent with a recent meta-analysis examining the relations among fish oil, HR, and the risk of cardiovascular disease.
The Impact of Squamous and Glandular Differentiation on Survival After Radical Cystectomy for Urothelial Carcinoma
Kim, Simon P. , Frank, Igor, Cheville, John C. , Thompson, R. Houston, Weight, Christopher , Thapa, Prabin , Boorjian, Stephen A.

Mayo Clinic

Journal of Urology | June 14, 2012 | Volume: 188 | Issue: 2 | Pages: 405-409

10.1016/j.juro.2012.04.020 | PMID 22704101 Get It

Sympathetic Activity and Baroreflex Sensitivity in Young Women Taking Oral Contraceptives
Minson, Christopher T. , Halliwill, John R. , Young, Tamica M., Joyner, Michael J. , Joyner, Michael J

Mayo Clinic

Circulation | June 12, 2012 | Volume: 102 | Issue: 13 | Pages: 1473-1476

10.1161/01.cir.102.13.1473 | PMID 11004135 Get It

Background —We tested sympathetic and cardiovagal baroreflex sensitivity during the placebo or “low-hormone” phase (LH) and 2 to 3 weeks later during the “high-hormone” phase (HH) of oral contraceptive (OC) use in 9 women. Methods and Results —Sympathetic baroreflex sensitivity was assessed by intravenous doses of sodium nitroprusside and phenylephrine and defined as the slope relating muscle sympathetic nerve activity (by microneurography) and diastolic blood pressure. Cardiovagal baroreflex sensitivity was defined as the slope relating R-R interval and systolic blood pressure. No difference was observed for resting muscle sympathetic nerve activity or plasma norepinephrine levels. However, sympathetic baroreflex sensitivity was greater and mean arterial pressure was higher during the LH than in the HH phase. Similarly, cardiovagal baroreflex sensitivity was greater in the LH than in the HH phase. Conclusions —Sympathetic and cardiovagal baroreflex sensitivities change during the 28-day course of OC use. Furthermore, changes in baroreflex sensitivity with OC differ from changes in baroreflex sensitivity during the normal menstrual cycle.
Relationship Between Delay in Performing Direct Coronary Angioplasty and Early Clinical Outcome in Patients With Acute Myocardial Infarction
Berger, Peter B. , Ellis, Stephen G. , Holmes, David R. , Granger, Christopher B. , Criger, Douglas A., Betriu, Amadeo, Topol, Eric J. , Califf, Robert M. , Granger, Christopher B

Mayo Clinic

Circulation | June 12, 2012 | Volume: 100 | Issue: 1 | Pages: 14-20

10.1161/01.cir.100.1.14 | PMID 10393675 Get It

Background —Time to treatment with thrombolytic therapy is a critical determinant of mortality in acute myocardial infarction. Little is known about the relationship between the time to treatment with direct coronary angioplasty and clinical outcome. The objectives of this study were to determine both the time required to perform direct coronary angioplasty in the Global Use of Strategies to Open Occluded Arteries in Acute Coronary Syndromes (GUSTO-IIb) trial and its relationship to clinical outcome. Methods and Results —Patients randomized to direct coronary angioplasty (n=565) were divided into groups based on the time between study enrollment and first balloon inflation. Patients randomized to angioplasty who did not undergo the procedure were also analyzed. The median time from study enrollment to first balloon inflation was 76 minutes; 19% of patients assigned to angioplasty did not undergo an angioplasty procedure. The 30-day mortality rate of patients who underwent balloon inflation ≤60 minutes after study enrollment was 1.0%; 61 to 75 minutes after enrollment, 3.7%; 76 to 90 minutes after enrollment, 4.0%; and ≥91 minutes after enrollment, 6.4%. The mortality rate of patients assigned to angioplasty who never underwent the procedure was 14.1% ( P =0.001). Logistic regression analysis revealed that the time from enrollment to first balloon inflation was a significant predictor of mortality within 30 days; after adjustment for differences in baseline characteristics, the odds of death increased 1.6 times ( P =0.008) for a movement from each time interval to the next. Conclusions —The time to treatment with direct PTCA, as with thrombolytic therapy, is a critical determinant of mortality.
Variation in the Region of the Angiotensin-Converting Enzyme Gene Influences Interindividual Differences in Blood Pressure Levels in Young White Males
Fornage, Myriam , Kardia, Sharon R., Boerwinkle, Eric , Amos, Christopher I. , Sing, Charles F. , Turner, Stephen T.

Mayo Clinic

Circulation | June 12, 2012 | Volume: 97 | Issue: 18 | Pages: 1773-1779

10.1161/01.cir.97.18.1773 | PMID 9603530 Get It

Background —The renin-angiotensin system regulates blood pressure through its effects on vascular tone, renal hemodynamics, and renal sodium and fluid balance. Methods and Results —Using data from a large population-based sample of 1488 siblings having a mean age of 14.8 years and belonging to the youngest generation of 583 randomly ascertained three-generation pedigrees from Rochester, Minn, we carried out variance components–based linkage analyses to evaluate the contribution of variation in four renin-angiotensin system gene regions (angiotensinogen, renin, angiotensin I–converting enzyme, and angiotensin II receptor type 1) to interindividual variation in systolic, diastolic, and mean arterial pressure. We rejected the null hypothesis that allelic variation in the region of the angiotensin-converting enzyme ( ACE ) gene does not contribute to interindividual blood pressure variability. After conditioning on measured covariates, variation in this region accounted for 0%, 13% ( P =0.04), and 16% ( P =0.04) of the interindividual variance in systolic, diastolic, and mean arterial pressures, respectively. These estimates were even greater in a subset of subjects with a positive family history of hypertension (0%, 29% [ P =0.005], and 32% [ P <0.005], respectively). In sex-specific analyses, genetic variation in the region of the ACE gene significantly influenced interindividual blood pressure variation in males (37% for SBP [ P =0.03], 38% for DBP [ P =0.04], and 53% for MAP [ P <0.005]) but not in females. Conclusions —Although it is possible that variation in a gene near the ACE gene may explain the observed results, knowledge about the physiological involvement of ACE in blood pressure regulation supports the proposition that the ACE gene itself influences blood pressure variability in a sex-specific manner.
Effects of Subtype-Selective and Balanced Angiotensin II Receptor Antagonists in a Porcine Coronary Artery Model of Vascular Restenosis
Huckle, William R. , Drag, Marlene , Acker, Wayne R., Powers, Michele, McFall, Rosemary C., Fujita, Tsuneo, Stabilito, Inez I., Kim, Dooseop, Ondeyka, Debra L., Mantlo, Nathan B., Chang, Raymond S.L., Reilly, Christopher, Schwartz, Robert S., Greenlee, William J. , Johnson, Robert Garret, Holder, Daniel

Mayo Clinic

Circulation | June 12, 2012 | Volume: 93 | Issue: 5 | Pages: 1009-1019

10.1161/01.cir.93.5.1009 | PMID 8598064 Get It

BackgroundNumerous studies have demonstrated the ability of angiotensin II (Ang II) receptor antagonists and angiotensin-converting enzyme (ACE) inhibitors to inhibit intimal hyperplasia after balloon dilatation of noncoronary arteries in small-animal models, suggesting an important role for Ang II in the response to injury. Although ACE inhibitors have not been similarly effective in nonhuman coronary models or in human restenosis trials, questions remain regarding the efficacy of ACE inhibitors against tissue ACE and the contributions of ACE-independent pathways of Ang II generation. Unlike ACE inhibitors, Ang II receptor antagonists have the potential to inhibit responses to Ang II independent of its biosynthetic origin.Methods and ResultsIn separate studies, three Ang II receptor antagonists, including AT1-selective (L-158,809), balanced AT1/AT2(L-163,082), and AT2-selective (L-164,282) agents, were evaluated for their ability to inhibit vascular intimal thickening in a porcine coronary artery model of vascular injury. Preliminary studies in a rat carotid artery model revealed that constant infusion of L-158,809 (0.3 or 1.0 mg·kg−1·d−1) reduced the neointimal cross-sectional area by up to 37% measured 14 days after balloon dilatation. In the porcine studies, animals were treated with vehicle or test compound beginning 2 days before and extending 28 days after experimental angioplasty. Left anterior descending, left circumflex, and/or right coronary arteries were injured by inflation of commercially available angioplasty balloons with placement of coiled metallic stents. Infusion of L-158,809 (1 mg·kg−1·d−1), L-163,082 (1 mg·kg−1·d−1), or L-164,282 (1.5 mg·kg−1·d−1) in the study animals yielded plasma drug levels sufficient either to chronically block or, for L-164,282, to spare pressor responses to exogenous Ang II. Neither L-158,809, L-163,082, nor L-164,282 had statistically significant effects (P=.12,P=.75, andP=.48, respectively, compared with vehicle-treated controls) on neointimal thickness (normalized for degree of injury) measured by morphometric analysis at day 28 after angioplasty.ConclusionsThese findings indicate that chronic blockade of Ang II receptors by either site-selective or balanced AT1/AT2antagonists is insufficient to inhibit intimal hyperplasia after experimental coronary vascular injury in the pig. The results further suggest that, unlike in the rat carotid artery, Ang II is not a major mediator of intimal thickening in the pig coronary artery.
Impact of Acute Pulmonary Rejection on Cardiac Function
McLarty, Allison J., McGregor, Christopher G.A. , Shu, Nai H., Miller, Virginia M. , Ritman, Erik L.

Mayo Clinic

Circulation | June 12, 2012 | Volume: 91 | Issue: 1 | Pages: 186-191

10.1161/01.cir.91.1.186 | PMID 7805201 Get It

Background Experiments were designed to define cardiac function in dogs with single lung allografts during acute rejection of the allografted lung. Methods and Results Left lungs were either autotransplanted (n=4) or allotransplanted (n=8) in adult male mongrel dogs. All allotransplanted animals were maintained on triple-drug immunosuppression (cyclosporine, azathioprine, and steroids) for 5 days after the operation. In 4 allotransplanted animals, treatment was discontinued, allowing the animals to reject (usually after a further 3 days; rejecting group); 4 other allotransplanted animals were maintained on immunosuppression for an additional 3 days (immunosuppressed group). Another group of dogs were not operated on but were maintained on the same immunosuppression as the rejecting group (controls). All experimental animals underwent fast computed tomographic scanning with measurement of left ventricular pressure and calculation of ventricular chamber volumes, cross-sectional areas of coronary arteries, myocardial perfusion, and intramyocardial blood volume. Neither cardiac output, left ventricular mass, left ventricular pressure, nor myocardial oxygen consumption was altered during acute rejection of lung allografts. However, left ventricular contractility (systolic elastance, E max ) and ejection fraction were depressed to approximately one half ( P <.05) in acutely rejecting animals compared with other groups. The cross-sectional area of the coronary arteries was less in autotransplanted and allotransplanted treated animals than in animals that were not operated on. Cross-sectional area of the coronary arteries was decreased by an additional 30% in the rejecting group ( P <.05). Conclusions The results of this study indicate that acute rejection of a single lung allograft decreases cardiac performance and reduces diameter of coronary arteries in the recipient. Alterations of circulating humoral factors and activated leukocytes may contribute to these changes.
Influence of the Menstrual Cycle on Sympathetic Activity, Baroreflex Sensitivity, and Vascular Transduction in Young Women
Minson, Christopher T. , Halliwill, John R. , Young, Tamica M., Joyner, Michael J. , Joyner, Michael J

Mayo Clinic

Circulation | June 11, 2012 | Volume: 101 | Issue: 8 | Pages: 862-868

10.1161/01.cir.101.8.862 | PMID 10694525 Get It

Background —Our goal was to test sympathetic and cardiovagal baroreflex sensitivity and the transduction of sympathetic traffic into vascular resistance during the early follicular (EF) and midluteal (ML) phases of the menstrual cycle. Methods and Results —Sympathetic baroreflex sensitivity was assessed by lowering and raising blood pressure with intravenous bolus doses of sodium nitroprusside and phenylephrine. It was defined as the slope relating muscle sympathetic nerve activity (MSNA; determined by microneurography) and diastolic blood pressure. Cardiovagal baroreflex sensitivity was defined as the slope relating R-R interval and systolic blood pressure. Vascular transduction was evaluated during ischemic handgrip exercise and postexercise ischemia, and it was defined as the slope relating MSNA and calf vascular resistance (determined by plethysmography). Resting MSNA (EF, 1170±151 U/min; ML, 2252±251 U/min; P <0.001) and plasma norepinephrine levels (EF, 240±21 pg/mL; ML, 294±25 pg/mL; P =0.025) were significantly higher in the ML than in the EF phase. Furthermore, sympathetic baroreflex sensitivity was greater during the ML than the EF phase in every subject (MSNA/diastolic blood pressure slopes: EF, −4.15; FL, −5.42; P =0.005). No significant differences in cardiovagal baroreflex sensitivity or vascular transduction were observed. Conclusions —The present study suggests that the hormonal fluctuations that occur during the normal menstrual cycle may alter sympathetic outflow but not the transduction of sympathetic activity into vascular resistance.
Initial Experience With Larger Laser Sheaths for the Removal of Transvenous Pacemaker and Implantable Defibrillator Leads
BYRD, CHARLES L., Love, Charles J. , Sellers, T. Duncan, Hayes, David L. , Reiser, Christopher, Epstein, Laurence M. , Wilkoff, Bruce L.

Mayo Clinic

Circulation | June 11, 2012 | Volume: 100 | Issue: 5 | Pages: 516-525

10.1161/01.cir.100.5.516 | PMID 10430766 Get It

Background —In a previous randomized trial, the 12F laser sheath removed pacing leads via the implant vein more successfully than traditional mechanical tools alone. Two larger sizes of laser sheath, the 14F and 16F models, were developed to extract defibrillator leads and large-diameter pacing leads implanted for the chronic. These devices use pulsed ultraviolet laser light to core though fibrotic tissue grown over the lead body to free the lead from the vasculature. A mandatory prospective registry studied the safety and effectiveness profiles of the larger laser sheaths vis-à-vis the 12F laser sheath. Methods and Results —In this study, 863 patients underwent extraction of 1285 leads at 52 sites. Patients treated with the 14F device tended to have older leads than the 12F population; the 16F population, which comprised mostly defibrillator patients, were younger, had younger leads, and were more often male than the 12F population. Clinical success (extracting the entire lead or the lead body minus the distal electrode) was observed in 91% to 92% of cases for all device sizes. The overall complication rate was 3.6%, with 0.8% perioperative mortality. Incidence of complications was independent of laser sheath size. Conclusions —The 14F and 16F laser sheaths offer an extraction option for larger long-term transvenous pacemaker and defibrillator leads that is as safe and effective as the 12F laser sheath.