Citations

Clear

108 citation(s) found for "Witt, C".

Sinus rhythm heart rate increase after atrial fibrillation ablation is associated with lower risk of arrhythmia recurrence
Killu, Ammar M. , Witt, Chance M. , Sugrue, Alan , Vaidya, Vaibhav R. , Monahan, Kristi H. , Lenz, Charles J., Yogeswaran, Vidhushei , Sun, Philip Y. , Hodge, David O. , Friedman, Paul A. , Packer, Douglas L. , Asirvatham, Samuel J. , Sugrue, Alan M, Vaidya, Vaibhav , Barnes, Stephanie, Friedman, Paul A , Asirvatham, Samuel J , Sun, Philip , Barnes, Stephanie

Mayo Clinic

Pacing and Clinical Electrophysiology | February 17, 2021 | Volume: 44 | Issue: 4 | Pages: 651-656

10.1111/pace.14197 | PMID 33592679 Get It

AbstractBackgroundPulmonary vein isolation (PVI) with autonomic modulation may be more successful than PVI alone for atrial fibrillation (AF) ablation and may be signaled by changes in sinus rhythm heart rate (HR) post ablation. We sought to determine if a change in sinus rhythm HR predicted AF recurrence post PVI.MethodsPatients who underwent AF ablation from 2000 to 2011 were included if sinus rhythm was noted on ECG within 90 days pre and 7 days post ablation. Basic ECG interval and HR changes were analyzed and outcomes determined.ResultsA total of 1152 patients were identified (74.3% male, mean age 57 ± 11 years). Mean AF duration was 5.2 ± 5.3 years. Paroxysmal AF was noted in 712 (61.8%) of the patients. Mean EF was 61% ± 6%. Sinus rhythm HR was 61 ± 11 pre‐ablation and 76 ± 13 bpm post‐ablation (27% ± 24% increase, p < .001). The ability of relative HR change post‐ablation to predict AF recurrence was borderline (hazard ratio 0.65 [0.41–1.01], p = .067). With patients separated into quartiles based on the relative HR change, the upper quartile with the largest relative increase in HR had a significantly lower rate of AF recurrence compared to the lowest quartile following multi variable modeling (p = .038). There were significant changes in PR (171 ± 28 to 167 ± 30 ms) and QTc (424 ± 25 to 434 ± 29 ms) intervals (both p < .001) but these were not predictive of outcome.ConclusionRelative changes in HR post AF ablation correlates with AF recurrence. Further prospective studies are needed to confirm this relationship.
A cross‐sectional evaluation of dermatopathology fellowship website content
Shimshak, Serena , Witt, Bryan , Chen, Joyce Y., Pollock, Jordan R. , Sokumbi, Olayemi , Shimshak, Serena J E , Witt, Bryan S, Pollock, Jordan Riley , Sokumbi, Olayemi

Mayo Clinic

Journal of Cutaneous Pathology | February 12, 2021 | Volume: 48 | Issue: 9 | Pages: 1213-1215

10.1111/cup.13982 | PMID 33576514 Get It

Efficacy of medical and ablation therapy for inappropriate sinus tachycardia: A single‐center experience
Shabtaie, Samuel A. , Witt, Chance M. , Asirvatham, Samuel J. , Asirvatham, Samuel J

Mayo Clinic

Journal of Cardiovascular Electrophysiology | February 10, 2021 | Volume: 32 | Issue: 4 | Pages: 1053-1061

10.1111/jce.14942 | PMID 33566447 Get It

AbstractBackgroundEffective therapy for inappropriate sinus tachycardia (IST) remains challenging with high rates of treatment failure and symptom recurrence. It is uncertain how effective pharmacotherapy and procedural therapy are long‐term, with poor response to medical therapy in general.MethodsWe retrospectively reviewed all patients with the diagnosis of IST at a tertiary academic medical center from 1998 to 2018. We extracted data related to prescribing patterns and symptom response to medical therapy and sinus node modification (SNM), assessing efficacy and periprocedural complication rates.ResultsA total of 305 patients with a formal diagnosis of IST were identified, with 259 (84.9%) receiving at least one prescription medication related to the condition. Beta‐blockers were the most commonly used medication (n = 245), with a majority of patients reporting no change or worsening of symptoms, and poor response was seen to other medication classes. Improvement was seen significantly more often with ivabradine than beta blockers, though the sample size was limited (p = .003). Fifty‐five patients (18.0% of all IST patients), mean age 32.0 ± 9.1 years, underwent a SNM procedure, with an average of 1.8 ± 0.9 procedures per patient. Acute symptomatic improvement (<6 months) was seen in 58.2% of patients. Long‐term complete resolution of symptoms was seen in 5.5% of patients, modest improvement in 29.1%, and no long‐term benefit was seen in 65.5% of patients.ConclusionsAmong all medical therapies, there were high rates of treatment failure or symptom worsening in over three‐quarters of patients in our study. Ivabradine was most beneficial, though the sample size was small. While most patients receiving SNM ablation for IST perceive an acute symptomatic improvement, almost two‐thirds of patients have no long‐term improvement, and resolution of symptoms is quite rare. AV node ablation with pacemaker implantation following lack of response to SNM offered increased success, though the sample size was limited.
Next-Generation Diamond Electrodes for Neurochemical Sensing: Challenges and Opportunities
Purcell, Erin K. , Becker, Michael , Guo, Yue , Hara, Seth A. , Ludwig, Kip A. , McKinney, Collin , Monroe, Elizabeth, Rechenberg, Robert, Rusinek, Cory A. , Saxena, Akash , Siegenthaler, James R. , Sortwell, Caryl E. , Witt, Suzanne E. , McKinney, Collin J , Trevathan, James K , Witt, Suzanne , Ludwig, Kip A , Monroe, Elizabeth, Thompson, Cort H. , Trevathan, James K. , Li, Wen

Mayo Clinic

Micromachines | January 26, 2021 | Volume: 12 | Issue: 2 | Pages: 128

10.3390/mi12020128 | PMID 33530395 Get It

Carbon-based electrodes combined with fast-scan cyclic voltammetry (FSCV) enable neurochemical sensing with high spatiotemporal resolution and sensitivity. While their attractive electrochemical and conductive properties have established a long history of use in the detection of neurotransmitters both in vitro and in vivo, carbon fiber microelectrodes (CFMEs) also have limitations in their fabrication, flexibility, and chronic stability. Diamond is a form of carbon with a more rigid bonding structure (sp3-hybridized) which can become conductive when boron-doped. Boron-doped diamond (BDD) is characterized by an extremely wide potential window, low background current, and good biocompatibility. Additionally, methods for processing and patterning diamond allow for high-throughput batch fabrication and customization of electrode arrays with unique architectures. While tradeoffs in sensitivity can undermine the advantages of BDD as a neurochemical sensor, there are numerous untapped opportunities to further improve performance, including anodic pretreatment, or optimization of the FSCV waveform, instrumentation, sp2/sp3 character, doping, surface characteristics, and signal processing. Here, we review the state-of-the-art in diamond electrodes for neurochemical sensing and discuss potential opportunities for future advancements of the technology. We highlight our team’s progress with the development of an all-diamond fiber ultramicroelectrode as a novel approach to advance the performance and applications of diamond-based neurochemical sensors.
Regulation of oral antigen delivery early in life: Implications for oral tolerance and food allergy
Yokanovich, Lila T. , Newberry, Rodney D. , Knoop, Kathryn A. , Witt, Lila T. , Knoop, Kathryn A , Newberry, Rodney D

Mayo Clinic

Clinical & Experimental Allergy | January 7, 2021 | Volume: 51 | Issue: 4 | Pages: 518-526

10.1111/cea.13823 | PMID 33403739 Get It

AbstractThe increasing incidence of food allergy remains a significant public health concern. Food allergy is partially due to a lack, or loss of tolerance to food allergens. Clinical outcomes surrounding early life practices, such as breastfeeding, antibiotic use and food allergen exposure, indicate the first year of life in children represents a unique time for shaping the immune system to reduce allergic outcomes. Animal models have identified distinctive aspects of when and where dietary antigens are delivered within the intestinal tract to promote oral tolerance prior to weaning. Additionally, animal models have identified contributions from maternal proteins from breast milk and bacterial products from the gut microbiota in regulating dietary antigen exposure and promoting oral tolerance, thus connecting decades of clinical observations on the benefits of breastfeeding, early food allergen introduction and antibiotic avoidance in the first year of life in reducing allergic outcomes. Here, we discuss how exposure to gut luminal antigens, including food allergens, is regulated in early life to generate protective tolerance and the implications of this process for preventing and treating food allergies.
A minimally invasive periacetabular osteotomy technique: minimizing intraoperative risks
Thiagarajah, Shankar, Witt, Johan , Bingham, Joshua S. , Grammatopoulos, George

Mayo Clinic

Journal of Hip Preservation Surgery | November 10, 2020 | Volume: 7 | Issue: 3 | Pages: 591-595

10.1093/jhps/hnaa040 | PMID 33948215 Get It

AbstractThe periacetabular osteotomy (PAO) is an extensive surgical procedure associated with potential risk to the adjacent neurovascular structures. A steep learning curve exists, with surgeon experience an important factor in outcome. Little detail exists of the osteotomies themselves, and how to make them safe and reproducible. This article describes our PAO technique with emphasis on specific safety steps. When performing the posterior column cut, migration of the osteotome beyond the lateral pelvis may lead to damage of the sciatic nerve. The safety features detailed include novel measurement of the posterior column width and the use of specific-width osteotomes to complete this osteotomy. To plan the cut, several computerized tomography-based measurements are taken starting just above the greater sciatic notch and continuing down to the inferior part of the acetabulum. The angle of this cut is determined by acetabular morphology and the width of the posterior column. These posterior column width measurements will determine the width of the osteotomes used to perform the cut with little risk that an osteotome will penetrate too far on the lateral side of the pelvis. To ensure the lateral cortex has been cut completely proximally, an osteotome with pre-measured depths may be used from a medial to a direct lateral trajectory. The senior author has been performing this modified approach since 2010 (n = 530 PAOs) and has witnessed no vascular injuries and no nerve injuries aside from minor lateral femoral cutaneous nerve issues. Utilization of these techniques has prevented any major nerve injury without the need for intraoperative electromyography.
S0053 Comparison of EUS-Guided Conventional Smear Cytology and Liquid Based Cytology in Pancreatic Lesions: A Systematic Review and Meta-Analysis
Keim, Lauren M., Khan, Shahab R. , Dhaliwal, Amaninder J., Shah, Aun R. , Bhogal, Neil, Mashiana, Harmeet S., Mashiana, Simran, Kassab, Lena L., Ponnada, Suresh, Bhat, Ishfaq , Singh, Shailender, Witt, Benjamin L., Chandan, Saurabh , Mohan, Babu P. , Ofosu, Andrew , Facciorusso, Antonio , Adler, Douglas G.

Mayo Clinic

American Journal of Gastroenterology | October 24, 2020 | Volume: 115 | Issue: 1 | Pages: S26-S26

10.14309/01.ajg.0000702260.63492.84 Get It

Comparison of EUS-guided conventional smear and liquid-based cytology in pancreatic lesions: A systematic review and meta-analysis
Khan, Shahab R. , Ofosu, Andrew , Dhaliwal, Amaninder, Shah, Aun R. , Bhogal, Neil, Mashiana, Harmeet S., Mashiana, Simran, Kassab, Lena L., Ponnada, Suresh, Bhat, Ishfaq , Singh, Shailender, Witt, Benjamin L., Chandan, Saurabh , Mohan, Babu P. , Facciorusso, Antonio , Adler, Douglas G.

Mayo Clinic

Endoscopy International Open | October 22, 2020 | Volume: 08 | Issue: 11 | Pages: E1611-E1622

10.1055/a-1240-0027 | PMID 33140017 Get It

Abstract Background and study aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (EUS-FNA) has limitations of inadequate sampling and false-negative results for malignancy. It has been performed using conventional smear (CS) cytology with rapid on-site evaluation (ROSE) with reasonable diagnostic accuracy. An alternative to ROSE is liquid-based cytology (LBC). Commonly used LBC techniques include precipitation-based (SurePath™) and filtration-based (ThinPrep®, CellPrep®). Data regarding the diagnostic efficacy of LBC compared with CS are limited. Methods Multiple databases were searched through March 2020 to identify studies reporting diagnostic yield of EUS-guided CS and LBC in pancreatic lesions. Pooled diagnostic odds and rates of performance for the cytologic diagnoses of benign, suspicious, and malignant lesions were calculated. Diagnostic efficacy was evaluated by pooled rates of accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Results Nine studies with a total of 1308 patients were included in our final analysis. Pooled diagnostic odds of CS cytology were 1.69 (CI 1.02–2.79) and 0.39 (CI 0.19–0.8) for malignant lesions when compared to filtration-based and precipitation-based LBC techniques, respectively. For CS, precipitation-based and filtration-based LBC, pooled diagnostic accuracy was 79.7 %, 85.2 %, 77.3 %, sensitivity was 79.2 %, 83.6 %, 68.3 %, and specificity was 99.4 %, 99.5 %, 99.5 %, respectively. Conclusions The precipitation-based LBC technique (SurePath™) had superior diagnostic odds for malignant pancreatic lesions compared with CS cytology in the absence of ROSE. It showed superior accuracy and sensitivity, but comparable specificity and PPV. Diagnostic odds of CS cytology in the absence of ROSE were superior to the filtration-based LBC technique (ThinPrep®, Cellprep®) for diagnosing malignant pancreatic lesions.
Brain cancer induces systemic immunosuppression through release of non-steroid soluble mediators
Pfaller, Christian K. , Evgin, Laura , Khadka, Roman H., Tritz, Zachariah P. , Goddery, Emma N. , Fain, Cori E. , Yokanovich, Lila T. , Zheng, Jiaying , Schuelke, Matthew , Hansen, Michael J. , Tung, Wesley , Pease, Larry R. , Vile, Richard G. , Johnson, Aaron J. , Ayasoufi, Katayoun , Himes, Benjamin T., Schuelke, Matthew R, Witt, Lila T. , Pfaller, Christian K , Zheng, Jiaying , Himes, Benjamin , Jin, Fang , Parney, Ian F. , Johnson, Aaron J.

Mayo Clinic

Brain | September 19, 2020 | Volume: 143 | Issue: 12 | Pages: 3629-3652

10.1093/brain/awaa343 | PMID 33253355 Get It

Abstract Immunosuppression of unknown aetiology is a hallmark feature of glioblastoma and is characterized by decreased CD4 T-cell counts and downregulation of major histocompatibility complex class II expression on peripheral blood monocytes in patients. This immunosuppression is a critical barrier to the successful development of immunotherapies for glioblastoma. We recapitulated the immunosuppression observed in glioblastoma patients in the C57BL/6 mouse and investigated the aetiology of low CD4 T-cell counts. We determined that thymic involution was a hallmark feature of immunosuppression in three distinct models of brain cancer, including mice harbouring GL261 glioma, B16 melanoma, and in a spontaneous model of diffuse intrinsic pontine glioma. In addition to thymic involution, we determined that tumour growth in the brain induced significant splenic involution, reductions in peripheral T cells, reduced MHC II expression on blood leucocytes, and a modest increase in bone marrow resident CD4 T cells. Using parabiosis we report that thymic involution, declines in peripheral T-cell counts, and reduced major histocompatibility complex class II expression levels were mediated through circulating blood-derived factors. Conversely, T-cell sequestration in the bone marrow was not governed through circulating factors. Serum isolated from glioma-bearing mice potently inhibited proliferation and functions of T cells both in vitro and in vivo. Interestingly, the factor responsible for immunosuppression in serum is non-steroidal and of high molecular weight. Through further analysis of neurological disease models, we determined that the immunosuppression was not unique to cancer itself, but rather occurs in response to brain injury. Non-cancerous acute neurological insults also induced significant thymic involution and rendered serum immunosuppressive. Both thymic involution and serum-derived immunosuppression were reversible upon clearance of brain insults. These findings demonstrate that brain cancers cause multifaceted immunosuppression and pinpoint circulating factors as a target of intervention to restore immunity.
Incremental benefit of a novel signal recording system during mapping and ablation
Padmanabhan, Deepak , Sugrue, Alan , Vaidya, Vaibhav R. , Witt, Chance M. , Yasin, Omar , Naksuk, Niyada , Killu, Ammar M. , Foxall, T., Drakulic, Budimir , Venkatachalam, K, Asirvatham, Samuel J. , Vaidya, Vaibhav, Witt, Chance, Killu, Ammar, Venkatachalam, Kalapathi Lakshminarayana, Asirvatham, Samuel J , Foxall, Thomas

Mayo Clinic

EP Europace | August 10, 2020 | Volume: 23 | Issue: 1 | Pages: 130-138

10.1093/europace/euaa194 | PMID 33094311 Get It

Abstract Aims Current electrophysiology signal recording and mapping systems have limited dynamic range (DR) and bandwidth, which causes loss of valuable information during acquisition of cardiac signals. We evaluated a novel advanced signal processing platform with the objective to obtain and assess additional information of clinical importance. Methods and results Over 10 canines, we compared intracardiac recordings within all cardiac chambers, in various rhythms, in pacing and during radiofrequency (RF) ablation across two platforms; a conventional system and the PURE EP™ [(PEP); Bio Sig Technologies, Inc., Los Angeles, CA, USA]. Recording cardiac signals with varying amplitudes were consistently and reproducibly observed, without loss of detail or introduction of artefact. Further the amplitude of current of injury (COI) on the unipolar signals correlated with the instantaneous contact force (CF) recorded on the sensing catheter in all the animals (r2 = 0.94 in ventricle). The maximum change in the unipolar COI correlated with the change in local electrogram amplitude during non-irrigated RF ablation (r2 = 0.61 in atrium). Reduction in artefact attributable to pacing (20 sites) and noise during ablation (48 sites) was present on the PEP system. Within the PEP system, simultaneous display of identical signals, filtered differently, aided the visualization of discrete conduction tissue signals. Conclusion Compared to current system, the PEP system provided incremental information including identifying conduction tissue signals, estimates of CF and a surrogate for lesion formation. This novel signal processing platform with increased DR and minimal front-end filtering may be useful in clinical practice.