Citations

Clear

76 citation(s) found for "Alizad, Azra".

Quantifying nonlinear elasticity modulus of tissue-like solids using acoustic radiation force
Panahandeh-Shahraki, Danial, Kinnick, Randall R., Ghavami, Siavash , Guzina, Bojan B. , Kumar, Viksit , Urban, Matthew W. , Alizad, Azra , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1802-1802

10.1121/1.5035900 Get It

As shown in a recent study, estimation of the magnitude of the acoustic radiation force (ARF) in isotropic tissue-like solids is the key to measuring a third-order nonlinear modulus of elasticity (C)—responsible for coupling the shear and volumetric constitutive responses of a material. Due to experimental limitations, a direct measurement of the ARF in tissue is however difficult. To overcome this problem, we deploy 3D elastodynamic finite element (EFE) simulations of the ARF experiment in tissue-mimicking phantoms to estimate (i) the “background” shear modulus from the phase of the induced shear waves; (ii) the ARF magnitude from the shear wave amplitude, and (iii) the modulus C from the knowledge of the ARF. In this way, by interpreting the ARF-generated shear waves through the prism of 3D-EFE simulations, we facilitate local estimation of the nonlinear C modulus with spatial resolution equaling the size of the focal region. We call this method the C-Elastography (CE). In this study, the CE technique is applied to gelatin phantoms containing an agar-based inclusion. The profiles of the C-modulus in phantoms tested demonstrate good correlation with the phantom geometry, showing marked (and sharp) C-contrast at push points acting on the inclusion. [Acknowledgment: NIH-Grant EB23113.]
Vibro-acoustic method for detection of osteopenia and osteoporosis
Ghavami, Siavash , Gregory, Adriana , Webb, Jeremy, Denis, Max , Bayat, Mahdi , Fatemi, Mostafa , Alizad, Azra

Mayo Clinic

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1801-1801

10.1121/1.5035894 Get It

Early detection of osteopenia and osteoporosis is critical in identifying at-risk groups and manage necessary therapy. In this paper, a new noninvasive and quantitative vibro-acoustic method is proposed for detection of osteoporosis and osteopenia. In this method, we excite the bone by an ultrasound radiation force (URF) pulse. The URF pulse induces a vibration in the bone, resulting an acoustic wave that is received by a hydrophone placed on the skin. This prospective study included n = 23 volunteers. The number of volunteers with osteopenia and osteoporosis were 7, 6, respectively, and the number of volunteers with normal bone was 10. URF excitations were applied at four equi-distance points on the bone. The resulting acoustic signals were used for wave velocity estimation based on cross-correlation technique. In general, the hydrophone signal may be modeled as a superposition of different modes of bone vibration. Based on this model, we used variational mode decomposition (VMD) as an efficient technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions. Statistical analysis demonstrates that osteopenia and osteoporosis bones can be differentiated from normal bone with p< 0.001 using Wilcoxon rank-sum test on estimated velocity of the modes with maximum power.
Three‐Dimensional Shear Wave Elastography for Differentiating Benign From Malignant Thyroid Nodules
Zhao, Chong‐Ke , Chen, Shigao , He, Ya‐Ping, Wang, Qiao , Wang, Dan , Yue, Wenwen , Zhang, Kun , Wei, Qing , Xu, Hui‐Xiong, Chen, Shi-Gao, Alizad, Azra , He, Ya‐Ping, Qu, Shen , Xu, Hui‐Xiong

Mayo Clinic

Journal of Ultrasound in Medicine | January 10, 2018 | Volume: 37 | Issue: 7 | Pages: 1777-1788

10.1002/jum.14531 | PMID 29315789 Get It

ObjectivesTo prospectively evaluate the diagnostic performance of 3‐dimensional (3D) shear wave elastography (SWE) for assessing thyroid nodules.MethodsA total of 176 surgically or cytologically confirmed thyroid nodules (63 malignant and 113 benign) in 176 patients who had undergone conventional ultrasound (US), 2‐dimensional (2D) SWE, and 3D SWE examinations were included in this study. Quantitative elasticity values (mean elasticity, maximum elasticity, and standard deviation of elasticity of a large region of interest and mean elasticity of a 2‐mm region of interest) were measured on 2D and 3D SWE. Diagnostic performances of conventional US, 2D SWE, and 3D SWE were assessed. The role of 2D and 3D SWE in reducing unnecessary fine‐needle aspiration (FNA) for nodules with low suspicion was also evaluated.ResultsThe diagnostic performances in terms of the area under the receiver operating characteristic curve were 0.612 for conventional US, 0.836 for 2D SWE (P < .001 in comparison with conventional US), and 0.839 for 3D SWE (P < .001 in comparison with conventional US). The mean elasticity achieved the highest diagnostic performance in 2D SWE, whereas the standard deviation of elasticity achieved the highest performance in 3D SWE, although no significant difference was found between them (P > .05). Three‐dimensional SWE increased the specificity in comparison with 2D SWE (88.5% versus 82.3%; P = .039). For the 37 nodules with low suspicion on conventional US imaging, 2D SWE was able to avoid unnecessary FNA in 77.1% (27 of 35) of benign nodules, and 3D SWE further increased the number to 88.6% (31 of 35).ConclusionsThree‐dimensional SWE is a useful tool for predicting thyroid nodule malignancy and reducing unnecessary FNA procedures in thyroid nodules with low suspicion of malignancy.
Measurement of tissue viscoelasticity with ultrasound
Greenleaf, James F. , Alizad, Azra

Mayo Clinic

SPIE Proceedings | February 28, 2017 | Volume: 10067 | Issue: No issue available | Pages: 1006705

10.1117/12.2256842 Get It

Automated Compression Device for Viscoelasticity Imaging
Nabavizadeh, Alireza , Kinnick, Randall R., Bayat, Mahdi , Amador, Carolina , Fatemi, Mostafa , Urban, Matthew W. , Alizad, Azra , Fatemi, Mostafa

Mayo Clinic

IEEE Transactions on Biomedical Engineering | September 22, 2016 | Volume: 64 | Issue: 7 | Pages: 1535-1546

10.1109/tbme.2016.2612541 | PMID 28113299 Get It

Clinical results of ultrasound bladder vibrometry for assessment of bladder compliance
Cheong, Mathew , Denis, Max , Gregory, Adriana , Nenadic, Ivan , Husmann, Douglas A. , Mynderse, Lance A. , Bayat, Mahdi , Kumar, Viksit , Mehrmohammadi, Mohammad , Alizad, Azra , Fatemi, Mostafa

Mayo Clinic

Journal of the Acoustical Society of America | May 6, 2016 | Volume: 139 | Issue: 4_Supplement | Pages: 2176-2176

10.1121/1.4950464 Get It

Healthy human bladder is a viscoelastic shell capable of expanding to allow storage of urine at low pressures. The ability to maintain low pressures as the urine volume increases is called bladder compliance. Compliance is a key in proper functioning of urinary system. Spinal cord injuries and other neurogenic diseases can cause deterioration in bladder expansion capability (e.g., through excessive growth of fibrotic tissue), which in turn can increase the rigidity of the wall and reduce bladder compliance. Urodynamic study (UDS) is the clinical standard for evaluation of the bladder compliance through observation of bladder pressure-volume behavior. However, this method is costly and invasive. Ultrasound bladder vibrometry (UBV) has been introduced as noninvasive technique for evaluation of bladder viscoelasticity through excitation of the bladder using ultrasound radiation force and tracking the resulting Lamb waves. Here, we present the results of UBV from 44 patients undergoing concurrent UDS and UBV studies. Our results show that elasticity parameters obtained from the UBV closely correlate with the UDS pressure-volume data with a median Pearson’s correlation value of more than 0.8. These results prove the potential utility of UBV as an alternative noninvasive method for bladder compliance assessment. [Work supported by NIH grant DK99231.]
Differentiation of breast lesions based on viscoelasticity response at sub-Hertz frequencies
Nabavizadeh, Alireza , Gregory, Adriana , Bayat, Mahdi , Kumar, Viksit , Alizad, Azra , Fatemi, Mostafa

Mayo Clinic

Journal of the Acoustical Society of America | May 6, 2016 | Volume: 139 | Issue: 4_Supplement | Pages: 2028-2028

10.1121/1.4949985 Get It

There is an urgent need for a noninvasive but more accurate method to assess breast masses before referring the patient to biopsy. In this study, we use the slow viscoelastic creep response to evaluate breast masses at low (&lt;1 Hz) frequencies. This method uses an automated ramp-and-hold compression device and a high-frame-rate ultrasound imaging to track tissue strain. The study cohort included 30 pre-biopsy patients with suspicious masses. Sequential high-frame-rate images were recorded during the ramp-and-hold process. The data were used to calculate the creep response at each point. Then, using a classic linear model, the retardation-time map was created within the field of view. The resulting retardation-time maps exhibited clear distinction of the mass margins. The results showed that benign breast lesions appear with an increase in creep retardation-time compared to surrounding breast glandular tissue, and the opposite trend was true for the malignant lesions. Statistical analysis of the viscoelasticity features revealed that a contrast feature based on the retardation-time is an accurate classifier of malignant and benign masses (P&lt;0.0003). It is concluded that the retardation time is a promising biomarker for differentiation of breast masses. [Work supported by NIH Grant CA168575.]
A generalized reconstruction framework for transient elastography
Aquino, Wilkins , Bayat, Mahdi , Ghosh, Susanta , Alizad, Azra , Fatemi, Mostafa

Mayo Clinic

Journal of the Acoustical Society of America | May 6, 2016 | Volume: 139 | Issue: 4_Supplement | Pages: 2028-2028

10.1121/1.4949984 Get It

Ultrasound transient elastography has emerged as a promising imaging modality for noninvasive evaluation of tissue mechanical properties. Most of the established techniques, however, rely on a pointwise measurement of the induced shear wave speed based on a localized planar wave propagation assumption. This assumption is not always true as most tissues exhibit heterogamous characteristics. Complex interaction of different geometries, boundary conditions, and tissue composition limit the ability of these techniques such that additional spatial-temporal filtering and signal truncations are required. These signal conditionings might lead to improvement in elasticity estimation for some cases (e.g. certain geometries, material properties) but the fact that they do not stem from a comprehensive framework can lead to unrealistic mechanical properties in more complex scenarios. We present a generalized framework based on inverse solution of the elasto-dynamic equations which can simultaneously solve for material properties and geometries without requiring any prior knowledge of the wave types. The method is based on a modified error in constitutive equation (MECE) without requiring additional filtering. We present the results of standard phantom studies based on acoustic radiation force excitation and fast ultrasound tracking where MECE technique successfully estimated the elastic moduli and geometry. [Work supported by NIH grant CA174723.]
Bone demineralization assessment using acoustic radiation force
Denis, Max , Wan, Leighton , Cheong, Mathew , Fatemi, Mostafa , Alizad, Azra

Mayo Clinic

Journal of the Acoustical Society of America | May 6, 2016 | Volume: 139 | Issue: 4_Supplement | Pages: 2028-2028

10.1121/1.4949983 Get It

In this work, an ultrasound-guided remote measurement technique is proposed for bone demineralization assessment. Utilizing an acoustic radiation force (ARF) beam as our excitation source and a receiving hydrophone, the mechanical properties of a bone can be noninvasively assessed. Focusing the ARF beam on the bone surface acts as point force generating vibrational waves. Coupling the bone surface and hydrophone, the ensuing radiating acoustic pressure from these vibrational waves are captured for analysis. Of particular interest, are the features best related to the bone’s mechanical properties. Conducting ex-vivo experiments demonstrated that the velocity feature best delineates intact and demineralized bones. The typical velocity of an intact bone (3000 m/s) is higher in comparison to a 72 h demineralized bone (1600 m/s). According to the receiver operating characteristic (ROC) curve, the optimal velocity cut-off value of 3096 m/s yields 80% sensitivity and 82.61% specificity between the intact and demineralized bones. Other features, such as the spectra of the demineralized bones’ acoustic response, exhibited higher attenuation for frequencies below 200 kHz in comparison to the intact bones. A time-frequency analysis demonstrated a frequency shift with demineralization. These results demonstrate the potential application of our proposed technique for monitoring bone demineralization.
Spatially uniform harmonic acoustic radiation force excitation using one-dimensional linear array
Bayat, Mahdi , Alizad, Azra , Fatemi, Mostafa

Mayo Clinic

Journal of the Acoustical Society of America | May 1, 2015 | Volume: 137 | Issue: 4_Supplement | Pages: 2314-2315

10.1121/1.4920447 Get It

Low frequency harmonic force excitation can be used for both imaging and tissue characterization. This type of excitation can be achieved via intersecting two beams that slightly differ in frequency. One requirement of this technique is creating focused intersecting beams using available hardware. Previous studies have suggested different configurations for creating harmonic radiation force using linear arrays. However, these methods rely on identical frequency response assumption across all elements of the aperture. In practice, this assumption can be easily violated, especially if the transmit frequencies are not around the center frequency of the probe. When using electronic steering and focusing at different locations, this can result in a non-uniform radiation force pattern due to frequency changes in the sub-aperture. When used for vibro-acoustography, this manifests as vertical streaks in the final image that can severely degrade the quality of the image. We present a novel technique that minimizes element transmit frequency switching which in turn results in a more uniform excitation intensity. The results of applying this aperture configuration for vibro-acoustography imaging of breast phantoms with hard inclusions show significant improvements over previous methods. [This work was supported by NIH Grant R01 EB17213.]