Citations

Clear

9383 citation(s) found for "Thomas, PS".

Morphology of the Musculus Uvulae In Vivo Using MRI and 3D Modeling Among Adults With Normal Anatomy and Preliminary Comparisons to Cleft Palate Anatomy
Chen, Joshua Y., Kotlarek, Katelyn J. , Haenssler, Abigail E. , Sutton, Bradley P. , Kuehn, David P., Sitzman, Thomas J. , Perry, Jamie L. , Fang, Xiangming

Mayo Clinic

The Cleft Palate Craniofacial Journal | February 20, 2019 | Volume: 56 | Issue: 8 | Pages: 993-1000

10.1177/1055665619828226 | PMID 30786757 Get It

Purpose: To investigate the musculus uvulae morphology in vivo in adults with normal velopharyngeal anatomy and to examine sex and race effects on the muscle morphology. We also sought to provide a preliminary comparison of musculus uvulae morphology in adults with normal velopharyngeal anatomy to adults with repaired cleft palate. Methods: Three-dimensional magnetic resonance imaging data and Amira 5.5 Visualization Modeling software were used to evaluate the musculus uvulae in 70 participants without cleft palate and 6 participants with cleft palate. Muscle length, thickness, width, and volume were compared among participant groups. Results: Analysis of covariance analysis did not yield statistically significant differences in musculus uvulae length, thickness, width, or volume by race or sex among participants without cleft palate when the effect of body size was accounted for. Two-sample t test revealed that the musculus uvulae in participants with repaired cleft palate is significantly shorter ( P = .008, 13.65 mm vs 16.07 mm) and has less volume ( P = .002, 51.08 mm 3 vs 97.62 mm 3 ) than participants without cleft palate. Conclusion: In adults with normal velopharyngeal anatomy, the musculus uvulae is a cylindrical oblong-shaped muscle lying on the nasal surface of the soft palate, with its greatest bulk located just nasal to the levator veli palatini muscle sling. In participants with repaired cleft palate, the musculus uvulae is substantially reduced in volume. This diminished muscle bulk located just at the point where the palate contacts the posterior pharyngeal wall may contribute to velopharyngeal insufficiency in children with repaired cleft palate.
Uniform combined reconstruction of multichannel 7T knee MRI receive coil data without the use of a reference scan
Chebrolu, Venkata V. , Kollasch, Peter , Deshpande, Vibhas , Grinstead, John, Howe, Benjamin M., Frick, Matthew A., Fagan, Andrew , Benner, Thomas, Heidemann, Robin M. , Felmlee, Joel P. , Amrami, Kimberly K. , Chebrolu, Venkata Veerendranadh , Fagan, Andrew J , Howe, Benjamin M.

Mayo Clinic

Journal of Magnetic Resonance Imaging | February 19, 2019 | Volume: 50 | Issue: 5 | Pages: 1534-1544

10.1002/jmri.26691 | PMID 30779475 Get It

BackgroundMR image intensity nonuniformity is often observed at 7T. Reference scans from the body coil used for uniformity correction at lower field strengths are typically not available at 7T.PurposeTo evaluate the efficacy of a novel algorithm, Uniform Combined Reconstruction (UNICORN), to correct receive coil‐induced nonuniformity in musculoskeletal 7T MRI without the use of a reference scan.Study TypeRetrospective image analysis study.SubjectsMRI data of 20 subjects was retrospectively processed offline.Field Strength/Sequence: Knees of 20 subjects were imaged at 7T with a single‐channel transmit, 28‐channel phased‐array receive knee coil. A turbo‐spin‐echo sequence was used to acquire 33 series of images.AssessmentThree fellowship‐trained musculoskeletal radiologists with cumulative experience of 42 years reviewed the images. The uniformity, contrast, signal‐to‐noise ratio (SNR), and overall image quality were evaluated for images with no postprocessing, images processed with N4 bias field correction algorithm, and the UNICORN algorithm.Statistical TestsIntraclass correlation coefficient (ICC) was used for measuring the interrater reliability. ICC and 95% confidence intervals (CIs) were calculated using the R statistical package employing a two‐way mixed‐effects model based on a mean rating (k = 3) for absolute agreement. The Wilcoxon signed‐rank test with continuity correction was used for analyzing the overall image quality scores.ResultsUNICORN was preferred among the three methods evaluated for uniformity in 97.9% of the pooled ratings, with excellent interrater agreement (ICC of 0.98, CI 0.97–0.99). UNICORN was also rated better than N4 for contrast and equivalent to N4 in SNR with ICCs of 0.80 (CI 0.72–0.86) and 0.67 (CI 0.54–0.77), respectively. The overall image quality scores for UNICORN were significantly higher than N4 (P < 6 × 10‐13), with good to excellent interrater agreement (ICC 0.90, CI 0.86–0.93).Data ConclusionWithout the use of a reference scan, UNICORN provides better image uniformity, contrast, and overall image quality at 7T compared with the N4 bias field‐correction algorithm.Level of Evidence: 4Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2019;50:1534–1544.
Robust CT ventilation from the integral formulation of the Jacobian
Castillo, Edward , Castillo, Richard , Vinogradskiy, Yevgeniy , Solís, David , Myziuk, Nicholas , Thompson, A. , Guerra, Rudy, Guerrero, Thomas , Dougherty, Michele, Dougherty, M. K. , NAIR, GIRISH BALACHANDRAN

Mayo Clinic

Medical Physics | February 19, 2019 | Volume: 46 | Issue: 5 | Pages: 2115-2125

10.1002/mp.13453 | PMID 30779353 Get It

Computed tomography (CT) derived ventilation algorithms estimate the apparent voxel volume changes within an inhale/exhale CT image pair. Transformation‐based methods compute these estimates solely from the spatial transformation acquired by applying a deformable image registration (DIR) algorithm to the image pair. However, approaches based on finite difference approximations of the transformation's Jacobian have been shown to be numerically unstable. As a result, transformation‐based CT ventilation is poorly reproducible with respect to both DIR algorithm and CT acquisition method.PurposeWe introduce a novel Integrated Jacobian Formulation (IJF) method for estimating voxel volume changes under a DIR‐recovered spatial transformation. The method is based on computing volume estimates of DIR mapped subregions using the hit‐or‐miss sampling algorithm for integral approximation. The novel approach allows for regional volume change estimates that (a) respect the resolution of the digital grid and (b) are based on approximations with quantitatively characterized and controllable levels of uncertainty. As such, the IJF method is designed to be robust to variations in DIR solutions and thus overall more reproducible.MethodsNumerically, Jacobian estimates are recovered by solving a simple constrained linear least squares problem that guarantees the recovered global volume change is equal to the global volume change obtained from the inhale and exhale lung segmentation masks. Reproducibility of the IJF method with respect to DIR solution was assessed using the expert‐determined landmark point pairs and inhale/exhale phases from 10 four‐dimensional computed tomographies (4DCTs) available on www.dir-lab.com. Reproducibility with respect to CT acquisition was assessed on the 4DCT and 4D cone beam CT (4DCBCT) images acquired for five lung cancer patients prior to radiotherapy.ResultsThe ten Dir‐Lab 4DCT cases were registered twice with the same DIR algorithm, but with different smoothing parameter. Finite difference Jacobian (FDJ) and IFJ images were computed for both solutions. The average spatial errors (300 landmarks per case) for the two DIR solution methods were 0.98 (1.10) and 1.02 (1.11). The average Pearson correlation between the FDJ images computed from the two DIR solutions was 0.83 (0.03), while for the IJF images it was 1.00 (0.00). For intermodality assessment, the IJF and FDJ images were computed from the 4DCT and 4DCBCT of five patients. The average Pearson correlation of the spatially aligned FDJ images was 0.27 (0.11), while it was 0.77 (0.13) for the IFJ method.ConclusionThe mathematical theory underpinning the IJF method allows for the generation of ventilation images that are (a) computed with respect to DIR spatial accuracy on the digital voxel grid and (b) based on DIR‐measured subregional volume change estimates acquired with quantifiable and controllable levels of uncertainty. Analyses of the experiments are consistent with the mathematical theory and indicate that IJF ventilation imaging has a higher reproducibility with respect to both DIR algorithm and CT acquisition method, in comparison to the standard finite difference approach.
Impact of Balloon Guide Catheter Use on Clinical and Angiographic Outcomes in the STRATIS Stroke Thrombectomy Registry
Zaidat, Osama O. , Mueller‐Kronast, Nils , Hassan, Ameer E , Jadhav, Ashutosh P. , Froehler, Michael T. , Aziz‐Sultan, Mohammad Ali , Klucznik, Richard , Hellinger, Frank R, Yavagal, Dileep R. , Yao, Tom L., Gupta, Rishi , Martin, Coleman, Bozorgchami, Hormozd, Kaushal, Ritesh , Gandhi, Ravi H. , Peterson, Eric C. , Given, Curtis A., Mehta, Brijesh , Deshmukh, Vivek R., Starkman, Sidney , Linfante, Italo , McPherson, Scott H., Kvamme, Peter , Grobelny, Thomas, Hussain, Muhammad Shazam , Thacker, Ike, Vora, Nirav , Monteith, Stephen J., Ecker, Robert D., Schirmer, Clemens M. , Sauvageau, Eric , Chebl, Alex , Derdeyn, Colin P. , Maidan, Lucian, Badruddin, Aamir , Siddiqui, Adnan H. , Dumont, Travis M., Alhajeri, Abdulnasser, Taqi, Muhammad , Asi, Khaled, Carpenter, Jeffrey , Boulos, Alan S. , Jindal, Gaurav , Puri, Ajit S , Robinson, David , Kallmes, David F. , Baxter, Blaise, Jumaa, Mouhammad , Sunenshine, Peter, Majjhoo, Aniel, English, Joey , Fessler, Richard D., Delgado-Almandoz, Josser, Martin, Jerry C., Liebeskind, David S. , Investigators, on behalf of the STRATIS, Liebeskind, David S. , Siddiqui, Adnan H , Hassan, Ameer E , Schirmer, Clemens M , Jadhav, Ashutosh P , Haussen, Diogo C , Jahan, Reza , Saver, Jeffrey L. , Nogueira, Raul G. , Dashti, Shervin R , Chen, Peng R , Chitale, Rohan V , Deshaies, Eric Michael , Suzuki, Shuichi , Investigators, on behalf of the STRATIS, Derdeyn, Colin P

Mayo Clinic

Stroke | February 19, 2019 | Volume: 50 | Issue: 3 | Pages: 697-704

10.1161/strokeaha.118.021126 | PMID 30776994 Get It

Background and Purpose— Mechanical thrombectomy has been shown to improve clinical outcomes in patients with acute ischemic stroke. However, the impact of balloon guide catheter (BGC) use is not well established. Methods— STRATIS (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) was a prospective, multicenter study of patients with large vessel occlusion treated with the Solitaire stent retriever as first-line therapy. In this study, an independent core laboratory, blinded to the clinical outcomes, reviewed all procedures and angiographic data to classify procedural technique, target clot location, recanalization after each pass, and determine the number of stent retriever passes. The primary clinical end point was functional independence (modified Rankin Scale, 0–2) at 3 months as determined on-site, and the angiographic end point was first-pass effect (FPE) success rate from a single device attempt (modified Thrombolysis in Cerebral Infarction, ≥2c) as determined by a core laboratory. Achieving modified FPE (modified Thrombolysis in Cerebral Infarction, ≥2b) was also assessed. Comparisons of clinical outcomes were made between groups and adjusted for baseline and procedural characteristics. All participating centers received institutional review board approval from their respective institutions. Results— Adjunctive technique groups included BGC (n=445), distal access catheter (n=238), and conventional guide catheter (n=62). The BGC group had a higher rate of FPE following first pass (212/443 [48%]) versus conventional guide catheter (16/62 [26%]; P =0.001) and distal access catheter (83/235 [35%]; P =0.002). Similarly, the BGC group had a higher rate of modified FPE (294/443 [66%]) versus conventional guide catheter (26/62 [42%]; P <0.001) and distal access catheter (129/234 [55%]; P =0.003). The BGC group achieved the highest rate of functional independence (253/415 [61%]) versus conventional guide catheter (23/55 [42%]; P =0.007) and distal access catheter (113/218 [52%]; P =0.027). Final revascularization and mortality rates did not differ across the groups. Conclusions— BGC use was an independent predictor of FPE, modified FPE, and functional independence, suggesting that its routine use may improve the rates of early revascularization success and good clinical outcomes. Clinical Trial Registration— URL: https://www.clinicaltrials.gov . Unique identifier: NCT02239640.
Multicenter Trial of [18F]fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Staging of Head and Neck Cancer and Negative Predictive Value and Surgical Impact in the N0 Neck: Results From ACRIN 6685
Lowe, Val J. , Duan, Fenghai , Subramaniam, Rathan M. , Sicks, JoRean D., Romanoff, Justin , Bartel, Twyla B. , Yu, Jian Q. , Cognetti, David M. , Stack, Brendan C. , Nussenbaum, Brian A. , Richmon, Jeremy D. , Arnold, Charles D.

Mayo Clinic

Journal of Clinical Oncology | February 15, 2019 | Volume: 37 | Issue: 20 | Pages: 1704-1712

10.1200/jco.18.01182 | PMID 30768363 Get It

PURPOSE The objective of this study was to determine the negative predictive value (NPV) of positron emission tomography (PET)/computed tomography (CT) for the clinically N0 neck on the basis of neck dissection. METHODS Participants with newly diagnosed, first-time, head and neck squamous cell carcinoma (HNSCC) and at least one clinically N0 neck side for which dissection was planned were included. A total of 287 participants were prospectively enrolled from 23 American College of Radiology Imaging Network-qualified institutions. PET/CT was compared with findings at neck dissection. RESULTS PET/CT scans and pathology findings were available for 270 N0 neck sides from 212 participants. For visual assessment, the NPV specific to the clinical-N0 sides was 0.868 (95% CI, 0.803 to 0.925). For dichotomized maximum standardized uptake value, the NPVs specific to the nodal basins were 0.940 (95% CI, 0.928 to 0.952) and 0.937 (95% CI, 0.925 to 0.949) at prespecified cutoffs of 2.5 and 3.5, respectively. The optimal cutoff maximum standardized uptake value was determined to be 1.8, with an NPV of 0.942 (95% CI, 0.930 to 0.953). The PET/CT-informed surgical treatment plan was changed in 51 of 237 participants (22%) compared with the PET/CT-blinded surgical plan. In 34 participants (14%), this led to planned dissection of additional nodal levels. In 12 participants (5%), this led to fewer planned dissected nodal levels. Negative PET/CT scans in N0 necks was true negative in 87% and false negative in 13%. CONCLUSION [18F]fluorodeoxyglucose-PET/CT has high NPV for the N0 neck in T2 to T4 HNSCC. The surgical treatment plans on the basis of PET/CT findings may be changed in approximately 22% of this group. These findings suggest that [18F]fluorodeoxyglucose-PET/CT may assist the clinician in deciding on the best therapy for the clinically N0 neck in HNSCC. Well-designed clinical trials should be performed to test the outcome of omitting neck dissection by using PET/CT.
Longitudinal analysis of epigenome-wide DNA methylation reveals novel smoking-related loci in African Americans
Liu, Jiaxuan , Zhao, Wei , Ammous, Farah , Mosley, Thomas H. , Zhou, Xiang , Smith, Jennifer A. , Zhao, Wei , Turner, Stephen T. , Zhou, Xiang , Smith, Jennifer A , Zhao, Wei

Mayo Clinic

Epigenetics | February 15, 2019 | Volume: 14 | Issue: 2 | Pages: 171-184

10.1080/15592294.2019.1581589 | PMID 30764717 Get It

Heterochromatin anomalies and double-stranded RNA accumulation underlie C9orf72 poly(PR) toxicity
Zhang, Yong‐Jie , Guo, Lin , Gonzales, Patrick , Gendron, Tania F. , Wu, Yanwei , Jansen‐West, Karen , O’Raw, Aliesha D. , Pickles, Sarah , Prudencio, Mercedes , Carlomagno, Yari , Gachechiladze, Mariam A. , Tian, Ruilin , Chew, Jeannie , DeTure, Michael , Lin, Wen-Lang, Tong, Jimei, Daughrity, Lillian M. , Yue, Mei, Song, Yuping , Andersen, Jonathan W. , Castanedes‐Casey, Monica , Kurti, Aishe, Antognetti, Giovanna, McCampbell, Alexander , Rademakers, Rosa , Oskarsson, Björn , Kampmann, Martin , Ward, Michael E. , Fryer, John Denis , Link, Christopher D. , Shorter, James , Petrucelli, Leonard , Gonzales, Patrick K , Pickles, Sarah R , Chew, Jeannie , DeTure, Michael , Daughrity, Lillian M , Castanedes-Casey, Monica , McCampbell, Alexander , Rademakers, Rosa , Oskarsson, Björn , Dickson, Dennis W , Kampmann, Martin , Ward, Michael E , Shorter, James , Petrucelli, Leonard , Zhang, Yong-Jie , Prudencio, Mercedes , O'Raw, Aliesha , Gendron, Tania F , Guo, Lin , Ludwig, Connor , Datta, Abhishek, Dickson, Dennis W.

Mayo Clinic

Science | February 15, 2019 | Volume: 363 | Issue: 6428 | Pages: No page available

10.1126/science.aav2606 | PMID 30765536 Get It

How dipeptide repeats cause pathology A repeat expansion in the chromosome 9 open reading frame 72 ( C9orf72 ) gene is the most common known cause of two neurodegenerative diseases: frontotemporal dementia and amyotrophic lateral sclerosis. This expansion leads to the abnormal production of proteins of repeating dipeptides, but their contribution to disease pathogenesis remains unclear. Zhang et al. engineered a mouse model to study the consequences of one of these dipeptides—prolinearginine dipeptide repeat protein, poly(PR)—in the brain. They found that poly(PR) caused neuron loss as well as motor and memory impairments. These detrimental effects resulted from poly(PR)-induced perturbation of heterochromatin function, a tightly packed form of DNA that represses gene expression. Science , this issue p. eaav2606
An Evidence-Based Approach to Casting and Orthosis Management of the Pediatric, Adolescent, and Young Adult Population for Injuries of the Upper Extremity: A Review Article
McVeigh, Kimberly H. , Berger, Thomas , Cudahy, Ryan, Dekker, Timothy M., Brigham, Tara , Braxton, James C., Berger, Thomas G, Brigham, Tara J, Brigham, T J , Berger, Thomas G.

Mayo Clinic

Clinical Journal of Sport Medicine | February 12, 2019 | Volume: 31 | Issue: 2 | Pages: 151-162

10.1097/jsm.0000000000000718 | PMID 30730385 Get It

Objective: Review the use of upper-extremity orthoses and casts after injuries to the wrist and hand in the pediatric, adolescent, and young adult population. The common injuries reviewed include pediatric distal radius fractures, scaphoid fractures, metacarpal fractures, mallet fingers, volar plate injuries of the proximal interphalangeal (PIP) joint, and ulnar collateral ligament (UCL) tears of the thumb metacarpophalangeal (MCP) joint. Data Sources: We conducted a literature review from 1985 to 2016 of upper-extremity orthotic interventions. Non–English language citations and animal studies were excluded. Citations from retrieved studies were used to identify other relevant publications. This review included cases of common injuries to the upper extremity, which required orthotic intervention. Main Results: Immobilization recommendations for nonsurgical pediatric distal radius fractures, nonsurgical metacarpal fractures, mallet fingers, and UCL tears of the thumb MCP include a removable orthosis. Nondisplaced scaphoid fracture orthosis recommendations include initial immobilization in a nonremovable short-arm thumb spica cast. Volar plate injuries of the PIP joint require buddy straps for healing. Conclusions: The literature demonstrates the effectiveness of removable orthoses in healing, patient satisfaction, and time to return to activity after many common upper-extremity injuries. Removable orthoses should be considered an equal or superior treatment method to cast immobilization, immobilization of additional joints, or longer periods of immobilization.
Cognitive Reserve in Midlife is not Associated with Amyloid-β Deposition in Late-Life
Sharrett, A. Richey , Wong, Dean F. , Gottesman, Rebecca F. , Gottesman, Rebecca F , Rawlings, Andreea M. , Mosley, Thomas H. , Knopman, David S.

Mayo Clinic

Journal of Alzheimer's Disease | February 12, 2019 | Volume: 68 | Issue: 2 | Pages: 517-521

10.3233/jad-180785 | PMID 30775981 Get It