Citations

Showing 10 of 108171 citations.

Real‐World Patient Experience With Erenumab for the Preventive Treatment of Migraine
Robblee, Jennifer , Devick, Katrina L. , Mendez, Natasha, Potter, Jamie L., Slonaker, Jennifer, Starling, Amaal J. , Potter, Jamie, Starling, Amaal J

Mayo Clinic

Headache: The Journal of Head and Face Pain | September 17, 2020 | Volume: 60 | Issue: 9 | Pages: 2014-2025

10.1111/head.13951 | PMID 32920850 Get It

Background Erenumab, a calcitonin gene‐related peptide (CGRP) receptor monoclonal antibody, has been well tolerated with good efficacy for the preventive treatment of episodic and chronic migraine in phase 2 and phase 3 clinical trials. Limited post‐market observations are available to validate these findings in a real‐world tertiary headache clinic population with complex comorbidities and refractory migraine. Objective The goal of this study is to demonstrate the real‐world performance of erenumab among patients in a tertiary care headache clinic by describing patient selection, experience, and clinical characteristics after 6 months of erenumab therapy. Methods A retrospective, exploratory, observational study was conducted on patients receiving at least 1 erenumab injection (70 or 140 mg). Baseline data obtained by chart review and telephone calls were compared to 6‐month follow‐up telephone calls. The primary outcome was the reduction in self‐reported headache days per month at baseline compared to 6 months for those with complete 6‐month data. The significance level was set at P < .05. Secondary analyses explored the distribution of headache severity, responder rates, Migraine Disability Assessment scores, adverse effects, ineffective preventives, comorbidities, wearing‐off, and discontinuation. Results Of the 101 patients who consented to participate, 89.1% (90/101) were women, and the mean age of all patients was 49 years (range, 19‐80 years). At baseline, 94.1% (95/101) of patients had chronic migraine, 5.0% (5/101) had episodic migraine, and 18.8% (19/101) had medication overuse headache. The mean (SD) number of baseline headache and migraine days per month for the entire cohort were 24.3 (8.2) and 18.2 (9.3) days, respectively. Participants had numerous comorbidities and had tried a mean of 11.2 unique oral medications and 4.8 unique medication categories before receiving erenumab, including 83.2% (84/101) who had also received onabotulinumtoxinA. Six‐month post‐erenumab follow‐up data were available for 42.6% (43/101) of participants. For these 43 participants, the number of headache days per month decreased significantly by 6.5 days from a baseline mean (SD) of 24.8 (6.47) days to 18.3 (12) days at 6‐month follow‐up ( P < .001); similarly, the monthly migraine days decreased significantly by 8.4 days from a baseline mean of 19.1 (9.3) days to 10.7 days at 6‐month follow‐up ( P < .001). The 50% responder rate was 34.9% (15/43) for monthly headache days and 54.8% (23/43) for monthly migraine days. Of all 101 participants, 28 (27.7%) discontinued erenumab, primarily because it was ineffective (39.3%, 11/28) or because of adverse effects (42.9%, 12/28). Conclusion This post‐market observational study of patient experience describes response to erenumab in a real‐world tertiary headache clinic with a complex patient population. Overall, these complex patients had a significant positive clinical response to erenumab, but with high rates of discontinuation. This study also noted a 1‐week wearing‐off response and high rates of constipation. Further post‐market studies are needed to better characterize patient selection and real‐world response to erenumab.
Intraoperative management of a hybrid extracorporeal membrane oxygenation circuit for lung transplantation
Martin, Archer Kilbourne , Harrison, Barry, Fritz, Ashley Virginia , Landolfo, Kevin , Makey, Ian A., Sareyyüpoğlu, Başar , Brown, Thomas E. , Johnson, James L., Pham, Si M. , Thomas, Mathew , Thomas, Mathew , Harrison, Barry A, Landolfo, Kevin P, Thomas, Mathew , Pham, Si , Martin, Archer Kilbourne

Mayo Clinic

Journal of Cardiac Surgery | September 17, 2020 | Volume: 35 | Issue: 12 | Pages: 3560-3563

10.1111/jocs.15029 | PMID 32939826 Get It

Keratoconus Patient Satisfaction and Care Burden with Corneal Gas‐permeable and Scleral Lenses
Shorter, Ellen , Schornack, Muriel , Harthan, Jennifer , Nau, Amy , Fogt, Jennifer Swingle , Cao, Dingcai , Nau, Cherie B. , Nau, Cherie, Schornack, Muriel , Fogt, Jennifer Swingle

Mayo Clinic

Optometry and Vision Science | September 17, 2020 | Volume: 97 | Issue: 9 | Pages: 790-796

10.1097/opx.0000000000001565 | PMID 32941334 Get It

SIGNIFICANCE Scleral lenses (SLs) are increasingly being considered as the initial correction for patients with keratoconus. In this study, keratoconus patients report higher levels of comfort and visual satisfaction with SL compared with corneal gas‐permeable lenses (GPs). PURPOSE This study aimed to compare patient satisfaction and care burden associated with GP and SL for the management of keratoconus. METHODS An electronic survey was distributed by the National Keratoconus Foundation from October 2016 to March 2017. Age at diagnosis, initial and current treatment, lens complications, access to care, lens handling time, and annual out‐of‐pocket treatment costs were collected. Vision, lens comfort, and ease of use satisfaction were rated from 1 to 5. RESULTS A total of 422 responses were received, including 75 bilateral GP and 76 bilateral SL wearers. Scleral lens wearers had greater satisfaction with vision (3.2 ± 1.1 [SL] vs. 2.6 ± 1.1 [GP]; P <. 001) and comfort (3.3 ± 1.0 [SL] vs. 2.2 ± 1.2 [GP]; P <. 001) but similar ease of use satisfaction in both groups (2.8 ± 1.1 [SL] vs. 2.7 ± 1.1 [GP]; P <. 90). Both groups reported issues with cloudy or foggy vision (GP, 63%; SL, 58%) and contact lens discomfort (GP, 77%; SL, 67%). Although GP wearers reported more issues with lens movement or loss (40 [GP] vs. 18% [SL]), they had fewer difficulties with halos (53 vs. 72% [SL]) and lens handling (40%) compared with SL wearers (63%). Gas‐permeable lens (48%) and SL (45%) wearers spend 6 to 10 minutes daily handling their lenses. Sixty percent of GP wearers reported annual out‐of‐pocket cost expenses less than U.S.$1000, whereas only 41% of SL wearers reported the same. CONCLUSIONS Scleral lens wearers with keratoconus report greater satisfaction with vision and comfort than do GP wearers, although both groups reported cloudy vision and lens discomfort.
Comparison of Pneumatonometry and Transpalpebral Tonometry Measurements of Intraocular Pressure during Scleral Lens Wear
Fogt, Jennifer Swingle , Nau, Cherie B. , Schornack, Muriel , Shorter, Ellen , Nau, Amy , Harthan, Jennifer , Schornack, Muriel , Fogt, Jennifer Swingle

Mayo Clinic

Optometry and Vision Science | September 17, 2020 | Volume: 97 | Issue: 9 | Pages: 711-719

10.1097/opx.0000000000001574 | PMID 32941336 Get It

ABSTRACT SIGNIFICANCE As scleral lens wear becomes more common, understanding the impact of these lenses upon ocular physiology is critically important. Studies on the effect of scleral lens wear upon intraocular pressure (IOP) have used different instruments and have reported conflicting results. PURPOSE The purpose of this study was to compare assessment of IOP during scleral lens wear using pneumatonometry and transpalpebral tonometry. METHODS Twenty healthy subjects wore a small‐diameter (15.2 mm) and a large‐diameter (18.0 mm) scleral lens on the right eye, each for 1 hour in randomized order. IOP was assessed with pneumatonometry and transpalpebral tonometry on both eyes before lens application, immediately after lens application, after 1 hour of lens wear, and immediately after lens removal. Paired t test compared mean IOP in the study eye to the control eye. Repeated‐measures ANOVA was performed to take instrumentation, lens diameter, and their interaction into account in an analysis of the change in IOP in the study eye. RESULTS Mean peripheral IOP measured with pneumatonometry was not significantly different from baseline at any subsequent measurement. Measurements with transpalpebral tonometry, however, were significantly different during scleral lens wear immediately after application and after 1 hour of wear with both diameter lenses ( P <. 005), but were not significantly different after either sized lens was removed. Repeated‐measures ANOVA revealed that the instrument used to measure IOP was a significant factor in IOP changes found during lens wear ( P ≤. 001). CONCLUSIONS Assessment of IOP during scleral lens wear varies based upon the instrument that is used. Although further studies are clearly needed to further elucidate this issue, clinicians should continue to monitor optic nerve structure and function in scleral lens wearers, as they do in all patients.
Clinical Outcomes of Scleral Lens Fitting with a Data‐driven, Quadrant‐specific Design: Multicenter Review
Barnett, Melissa , Carrasquillo, Karen G. , Schornack, Muriel , Schornack, Muriel M, Schornack, Muriel

Mayo Clinic

Optometry and Vision Science | September 17, 2020 | Volume: 97 | Issue: 9 | Pages: 761-765

10.1097/opx.0000000000001576 | PMID 32941343 Get It

SIGNIFICANCE Alignment of the scleral lens haptic with the anterior ocular surface is of critical importance when fitting scleral lenses. The concept of leveraging big‐data analysis to drive lens design is explored in this study. This retrospective study evaluated fitting outcomes of a data‐driven, quadrant‐specific scleral lens design and found that most patients (76%) were successfully fit with this design. PURPOSE The purpose of this study was to evaluate clinical outcomes with a data‐driven, quadrant‐specific scleral lens design compared with traditional lens designs. METHODS For this multicenter retrospective observational study, A REDCap (Research Electronic Data Capture) survey was distributed to scleral lens practitioners who participated in β testing of a data‐driven, quadrant‐specific scleral lens design (study lens) between June 1, 2016, and January 31, 2017. Descriptive data were collected, and patient‐reported outcomes, visual acuity, and lens design outcomes achieved with the study lens were described. RESULTS Seventy‐five patients (85 eyes) were fit with the study lens design between June 2016 and January 2017. Mean patient age was 47 years (range, 17 to 77 years). Forty‐six were male, and 29 were female. Seventy‐six eyes (89%) were fit for corneal irregularity, whereas nine eyes (11%) were fit for management of ocular surface disease. Compared with habitual correction, 22% more eyes achieved 20/20 or better, and 21% more eyes achieved 20/40 or better. There was also a 60% decrease in the need for midday removal with the study lens. An average of two lenses were manufactured per eye to complete the fitting process. CONCLUSIONS Using a data‐driven, quadrant‐specific scleral lens resulted in visual improvement, a reduced need for midday removal, and an average of two lenses needed to complete the fitting process. Longer‐term clinical outcomes and the use of big‐data analysis to inform scleral lens design should be further explored.
Asymptomatic Females Are at Higher Risk for Perioperative TIA/Stroke and Males Are at Higher Risk for Long-Term Mortality after Carotid Artery Stenting: A Vascular Quality Initiative Analysis
Rocha-Franco, Joao A. Da, Barrett, Kevin M. , Huang, Josephine F. , Miller, David A. , Farres, Houssam , Brott, Thomas G. , Hakaim, Albert G., Da Rocha-Franco, Joao A, Erben, Young , Li, Yupeng , Tawk, Rabih G. , Freeman, William D. , Lin, Michelle , Meschia, James F.

Mayo Clinic

International Journal of Angiology | September 16, 2020 | Volume: 33 | Issue: 01 | Pages: 036-045

10.1055/s-0040-1712506 | PMID 38352638 Get It

AbstractThe study aims to review the sex differences with respect to transient ischemic attack (TIA)/stroke and death in the perioperative period and on long-term follow-up among asymptomatic patients treated with carotid stenting (CAS) in the vascular quality initiative (VQI). All cases reported to VQI of asymptomatic CAS (ACAS) patients were reviewed. The primary end point was risk of TIA/stroke and death in the in-hospital perioperative period and in the long-term follow-up. The secondary end point was to evaluate predictors of in-hospital perioperative TIA/stroke and mortality on long-term follow-up after CAS. There were 22,079 CAS procedures captured from January 2005 to April 2019. There were 5,785 (62.7%) patients in the ACAS group. The rate of in-hospital TIA/stroke was higher in female patients (2.7 vs. 1.87%, p = 0.005) and the rate of death was not significant (0.03 vs. 0.07%, p = 0.66). On multivariable logistic regression analysis, prior/current smoking history (odds ratio = 0.58 [95% confidence interval or CI = 0.39–0.87]; p = 0.008) is a predictor of in-hospital TIA/stroke in females. The long-term all-cause mortality is significantly higher in male patients (26.9 vs. 15.7%, p < 0.001). On multivariable Cox-regression analysis, prior/current smoking history (hazard ratio or HR = 1.17 [95% CI = 1.01–1.34]; p = 0.03), coronary artery disease or CAD (HR = 1.15 [95% CI = 1.03–1.28]; p = 0.009), chronic obstructive pulmonary disease or COPD (HR = 1.73 [95% CI = 1.55–1.93]; p < 0.001), threat to life American Society of Anesthesiologists (ASA) class (HR = 2.3 [95% CI = 1.43–3.70]; p = 0.0006), moribund ASA class (HR = 5.66 [95% CI = 2.24–14.29]; p = 0.0003), and low hemoglobin levels (HR = 0.84 [95% CI = 0.82–0.86]; p < 0.001) are the predictors of long-term mortality. In asymptomatic carotid disease patients, women had higher rates of in-hospital perioperative TIA/stroke and a predictor of TIA/stroke is a prior/current history of smoking. Meanwhile, long-term all-cause mortality is higher for male patients compared with their female counterparts. Predictors of long-term mortality are prior/current smoking history, CAD, COPD, higher ASA classification of physical status, and low hemoglobin level. These data should be considered prior to offering CAS to asymptomatic female and male patients and careful risks versus benefits discussion should be offered to each individual patient.
Effect of obstructive sleep apnea on right ventricular ejection fraction in patients with hypertrophic obstructive cardiomyopathy
Wang, Shengwei , Cui, Hao , Ji, Keshan, Ren, Changwei , Guo, Hongchang , Zhu, Changsheng , Lai, Yongqiang , Wang, Shuiyun, Wang, Shuiyun, Wang, Shuiyun , Wang, Shuiyun, Wang, Shuiyun

Mayo Clinic

Clinical Cardiology | September 16, 2020 | Volume: 43 | Issue: 10 | Pages: 1186-1193

10.1002/clc.23429 | PMID 32936469 Get It

AbstractBackgroundObstructive sleep apnea (OSA) is a common disease associated with worse structural and functional impairment of the heart in patients with hypertrophic obstructive cardiomyopathy (HOCM).HypothesisThe presence and severity of OSA can decrease the right ventricular ejection fraction (RVEF) in patients with HOCM.MethodsIn total, 151 consecutive patients with a confirmed diagnosis of HOCM at Fuwai Hospital between September 2017 and September 2018 were included. Polysomnography and cardiac magnetic resonance imaging were performed in all patients.ResultsOverall, 84 (55.6%) patients were diagnosed with OSA. The RVEF significantly decreased with the severity of OSA (none, mild, moderate‐severe: 46.1 ± 8.2 vs 42.9 ± 7.5 vs 41.4 ± 7.4, P = .009). The apnea‐hypopnea index (AHI) was significantly high in patients with RVEF<40% among the different OSA groups (mild, moderate:7.7 ± 2.4 vs 9.6 ± 2.9, P = .03; 24.4 ± 9.0 vs 36.3 ± 18.0, P = .01). In the multiple linear regression model, the right ventricular end‐systolic volume (β = −0.28, P < .001), AHI (β = −0.09, P = .02), and oxygen desaturation index (β = −0.11, P = .04) were independently associated with a decrease in RVEF (adjusted R2 = 0.347, P < .001). Furthermore, the prevalence of RVEF<40% was high in patients with OSA. Compared with RVEF>40%, RVEF<40% was associated with more symptoms, mainly chest pain, chest distress, NYHA class III or IV, pulmonary hypertension, and moderate or severe mitral regurgitation.ConclusionIn patients with HOCM, the presence and severity of OSA is independently associated with a lower RVEF. In addition, compared with patients with RVEF>40%, those with RVEF<40% had more symptoms, including chest pain, chest distress, and NYHA class III or IV.
Barrier Enclosure for Endotracheal Intubation in a Simulated COVID-19 Scenario: A Crossover Study
Laack, Torrey A. , Pollok, Franziska, Sandefur, Benjamin J. , Russi, Christopher S. , Yalamuri, Suraj , Yalamuri, Suraj M, Mullan, Aidan F.

Mayo Clinic

Western Journal of Emergency Medicine | September 16, 2020 | Volume: 21 | Issue: 5 | Pages: No page available

10.5811/westjem.2020.7.48574 | PMID 32970558 Get It

A novel engineered purified exosome product patch for tendon healing: An explant in an ex vivo model
Shi, Guidong , Wang, Zhanwen , Thoreson, Andrew R. , Jacobson, Daniel S. , Amadio, Peter C. , Behfar, Atta , Moran, Steven L. , Zhao, Chunfeng , Wang, Yicun , Zhao, Chunfeng , Behfar, Atta , Wang, Yicun , Shi, Guidong

Mayo Clinic

Journal of Orthopaedic Research | September 16, 2020 | Volume: 39 | Issue: 8 | Pages: 1825-1837

10.1002/jor.24859 | PMID 32936480 Get It

AbstractReducing tendon failure after repair remains a challenge due to its poor intrinsic healing ability. The purpose of this study is to investigate the effect of a novel tissue‐engineered purified exosome product (PEP) patch on tendon healing in a canine ex vivo model. Lacerated flexor digitorum profundus (FDP) tendons from three canines' paws underwent simulated repair with Tisseel patch alone or biopotentiated with PEP. For the ex vivo model, FDP tendons were randomly divided into three groups: FDP tendon repair alone group (Control), Tisseel patch alone group, and the Tisseel plus PEP (TEPEP) patch group. Following 4 weeks of tissue culture, the failure load, stiffness, histology, and gene expression of the healing tendon were evaluated. Transmission electron microscopy revealed that in exosomes of PEP the diameters ranged from 93.70 to 124.65 nm, and the patch release test showed this TEPEP patch could stably release the extracellular vesicle over 2 weeks. The failure strength of the tendon in the TEPEP patch group was significantly higher than that of the Control group and Tisseel alone group. The results of histology showed that the TEPEP patch group had the smallest healing gap and the largest number of fibroblasts on the surface of the injured tendon. Quantitative reverse transcription polymerase chain reaction showed that TEPEP patch increased the expression of collagen type III, matrix metallopeptidase 2 (MMP2), MMP3, MMP14, and reduced the expression of transforming growth factor β1, interleukin 6. This study shows that the TEPEP patch could promote tendon repair by reducing gap formation and inflammatory response, increasing the activity of endogenous cells, and formation of type III collagen.
Outcomes with catheter‐directed thrombolysis compared with anticoagulation alone in patients with acute deep venous thrombosis
Abraham, Bishoy , Sedhom, Ramy , Saad, Marwan , Elbadawi, Ayman , Elgendy, Islam Y. , Narayanan, Mahesh Anantha , Pershad, Ashish , Shamoun, Fadi , LaLonde, Thomas , Attallah, Antonious, Saad, Marwan , Elgendy, Islam Y , Anantha Narayanan, Mahesh , Pershad, Ashish , Megaly, Michael S. , Omer, Mohamed , Mena‐Hurtado, Carlos

Mayo Clinic

Catheterization and Cardiovascular Interventions | September 16, 2020 | Volume: 97 | Issue: 1 | Pages: No page available

10.1002/ccd.29226 | PMID 32936517 Get It

AbstractObjectiveThe authors aimed to investigate the benefits and risks of catheter‐directed thrombolysis (CDT) in acute deep venous thrombosis (DVT).BackgroundThe role of CDT in the management of DVT is evolving. Data on CDT versus anticoagulation alone in acute DVT is sparse.MethodsWe performed a systematic review and meta‐analysis of published studies that compared CDT to anticoagulation alone in patients with acute DVT.ResultsWe included 11 studies (four randomized control trials [RCTs] and seven observational studies) with a total of 8,737 patients. During hospital stay, patients who received CDT had higher odds of major bleeding (2.5% vs. 1.6%; OR 1.46, 95% CI [1.07, 1.98], p = .02), blood transfusion (10.8% vs. 6.2%; OR 1.8, 95% CI [1.52, 2.13], p < .001), and thromboembolism (15.5% vs. 10%; OR 1.67, 95% CI [1.47, 1.91], p < .001) compared with anticoagulation alone. At 6‐month follow‐up, patients who received CDT had higher venous patency (71.1% vs. 37.7%; OR 5.49, 95% CI [2.63, 11.5], p < .001) and lower postthrombotic syndrome (PTS; 27% vs. 40.7%; OR 0.44, 95% CI [0.22, 0.86], p = .02). During a mean follow‐up duration of 30.5 ± 28 months, CDT group continued to have higher venous patency (79.6% vs. 71.8%; OR 3.79, 95% CI [1.54, 9.32], p = .004) and lower PTS (44.7% vs. 50.5%; OR 0.43, 95% CI [0.23, 0.78], p = .006), but no difference in thromboembolism.ConclusionCompared with anticoagulation alone, CDT for patients with acute DVT was associated with a higher risk of complications, but a higher rate of venous patency and lower risk of postthrombotic syndrome at 2.5 years follow‐up.