Citations

Showing 10 of 108162 citations.

Editorial Commentary
Bearrick, Elizabeth , Koo, Kevin , Bearrick, Elizabeth N.

Mayo Clinic

Urology Practice | January 5, 2021 | Volume: 8 | Issue: 2 | Pages: 308-308

10.1097/upj.0000000000000205.02 | PMID 37145643 Get It

Determinants of Morbidity and Mortality Associated With Isolated Tricuspid Valve Surgery
Kawsara, Akram , Eleid, Mackram F. , Rihal, Charanjit S. , Nishimura, Rick A. , Alkhouli, Mohamad , Alkhouli, Mohamad , Nishimura, Rick A , Alqahtani, Fahad , Nkomo, Vuyisile T. , Pislaru, Sorin V. , Rihal, Charanjit S. , Schaff, Hartzell V. , Crestanello, Juan A.

Mayo Clinic

Journal of the American Heart Association | January 5, 2021 | Volume: 10 | Issue: 2 | Pages: No page available

10.1161/jaha.120.018417 | PMID 33399012 Get It

Background Whether the poor outcomes of isolated tricuspid valve surgery are related to the operation itself or to certain patient characteristics including late referral is unknown. Methods and Results Adult patients who underwent isolated tricuspid valve surgery were identified in the Nationwide Readmissions Database (2016–2017). Patients who had redo tricuspid valve surgery, endocarditis, or congenital heart disease were excluded. Multivariable logistic regression was performed to identify contributors to postoperative mortality. A total of 1513 patients were included (mean age 55.7±16.6 years, 49.6% women). Surrogates of late referral were frequent: 41% of patients were admitted with decompensated heart failure, 44.3% had a nonelective surgery status, 16.8% had advanced liver disease, and 31% had an unplanned hospitalization in the prior 90 days. The operation was performed on day 0 to 1 of the hospitalization in only 50% of patients, and beyond day 10 in 22% of patients. In‐hospital mortality occurred in 8.7% of patients. Median length of stay was 14 days (7–35 days), and median cost was $87 223 ($43 122–$200 872). In multivariable logistic regression analysis, surrogates for late referrals (acute heart failure decompensation, nonelective surgery status, or advanced liver disease) were the strongest predictors of in‐hospital mortality (odds ratio [OR], 4.75; 95% CI, 2.74–8.25 [ P <0.001]). This was also consistent in a second model incorporating unplanned hospitalizations in the 90 days before surgery as a surrogate for late referral (OR, 5.50; 95% CI, 2.28–10.71 [ P <0.001]). Conclusions The poor outcomes of isolated tricuspid valve surgery may be largely explained by the late referral for intervention. Studies are needed to determine the role of early intervention for severe isolated tricuspid regurgitation.
Prevalence of Glucose-6-Phosphate Dehydrogenase Deficiency and Gametocytemia in a Pre-Elimination, Low Malaria Transmission Setting in Southern Zambia
Kobayashi, Tamaki , Kurani, Shaheen , Hamapumbu, Harry, Stevenson, Jennifer C. , Thuma, Philip E. , Moss, William J. , _, _, _, _

Mayo Clinic

The American Journal of Tropical Medicine and Hygiene | January 5, 2021 | Volume: 104 | Issue: 3 | Pages: 1000-1002

10.4269/ajtmh.20-1187 | PMID 33399042 Get It

ABSTRACTThe WHO recommends single low-dose (SLD) primaquine as a gametocytocide to reduce Plasmodium falciparum transmission in areas of low transmission. Despite this recommendation, uptake of SLD primaquine has been low because of concerns of glucose-6-phosphate dehydrogenase (G6PD) deficiency. Individuals with G6PD deficiency can experience hemolysis when exposed to primaquine. In Southern Province, Zambia, malaria transmission has declined significantly over the past decade. Single low-dose primaquine may be an effective tool, but there is limited information on G6PD deficiency. We screened 137 residents in Macha, Southern Province, Zambia, and the prevalence of G6PD (A−) was 15%. We also revisited data collected from 2008 to 2013 in the same area and found the highest gametocyte burden among those aged 5–15 years. The findings from this study suggest that SLD primaquine targeted to school-aged children may be an effective tool to help achieve malaria elimination in southern Zambia.
Impact on urinary oxalate levels with use of ezetimibe
Trautman, Christopher L. , Cleve, Margaret Van , Sullivan, Emily A., Ball, Colleen T. , Cochuyt, Jordan J., Porter, Ivan E. , Van Cleve, Margaret, Porter, Ivan

Mayo Clinic

Endocrinology, Diabetes & Metabolism | January 5, 2021 | Volume: 4 | Issue: 2 | Pages: No page available

10.1002/edm2.221 | PMID 33855221 Get It

AbstractBackgroundCalcium oxalate stones are the most common cause of nephrolithiasis in the United States. Smaller studies of <15 patients investigating ezetimibe, a selective cholesterol absorption inhibitor, have suggested increased urine oxalate levels with use of the drug. We attempt to better define this relationship of ezetimibe on urinary oxalate using a larger patient sample analysing multiple urine collections on and off treatment.Materials and MethodsWe retrospectively reviewed all consecutive patients from 01/2018 through 04/2019 evaluated for nephrolithiasis with use of ezetimibe documented in their medical record at Mayo Clinic Florida. Primary outcomes included increase in urinary oxalate with use of ezetimibe and reduction in urinary oxalate with discontinuation of medication.ResultsOf 57 reviewed patients, 30 (53%) met inclusion criteria yielding 117 24‐h urine measurements either on ezetimibe (72 measurements) or off ezetimibe (41 measurements). The mean urinary oxalate level off ezetimibe was 39.86 mg versus 40.45 mg with ezetimibe. After adjusting for age and sex, the estimated difference was 1.239 mg (95% CI, −4.856 to 7.335 mg; p = 0.93). A subset of six patients with urinary oxalate values both on and off ezetimibe showed a difference in 24‐h urinary oxalate levels ranged from −16.40 to 14.95 mg (mean difference = 0.93 mg; median difference = 3.84 mg).ConclusionUse of ezetimibe does not provide clear evidence of a difference in urinary oxalate levels.
Visualization of user interactions with a pressure mapping mobile application for wheelchair users at risk for pressure injuries
Goodwin, Brianna M. , Olney, Christine M. , Ferguson, John E. , Hansen, Andrew H. , Eddy, Byron , Goldish, Gary D, Morrow, Melissa M. , Vos-Draper, Tamara , Vos-Draper, Tamara L , Morrow, Melissa M

Mayo Clinic

Assistive Technology | January 4, 2021 | Volume: 34 | Issue: 4 | Pages: 444-453

10.1080/10400435.2020.1862938 | PMID 33395558 Get It

In adults with hypertension, more- vs. less-intensive BP-lowering treatment reduces orthostatic hypotension
Yousufuddin, Mohammed , Kashani, Kianoush

Mayo Clinic

Annals of Internal Medicine | January 4, 2021 | Volume: 174 | Issue: 1 | Pages: JC7

10.7326/acpj202101190-007 | PMID 33395341 Get It

Initial testing of pegfilgrastim (Neulasta Onpro) on‐body injector in multiple radiological imaging environments
Long, Zaiyang , Kurup, A. Nicholas , Jensen, Nicole M., Hangiandreou, Nicholas J., Schueler, Beth A. , Yu, Lifeng , Wood, Christopher P. , Felmlee, Joel P. , Kurup, Anil Nicholas, Kurup, Anil N , Yu, Lifeng , Leng, Shuai

Mayo Clinic

Journal of Applied Clinical Medical Physics | January 4, 2021 | Volume: 22 | Issue: 1 | Pages: 343-349

10.1002/acm2.13156 | PMID 33395503 Get It

AbstractPurposeAn increasing number of implantable or external devices can impact whether patients can receive radiological imaging examinations. This study examines and tests the Neulasta (pegfilgrastim) Onpro on‐body injector in multiple imaging environments.MethodsThe injector was analyzed for four imaging modalities with testing protocols and strategies developed for each modality. In x‐ray and computed tomography (CT), scans with much higher exposure than clinical protocols were performed with the device attached to an anthropomorphic phantom. The device was monitored until the completion of drug delivery. For magnetic resonance imaging (MRI), the device was assessed using a hand‐held magnet and underwent the magnetically induced displacement testing in a 1.5T clinical MRI scanner room. For ultrasound, magnetic field changes were measured around an ultrasound scanner system with three transducers.ResultsFor x‐ray and CT no sign of device error was identified during or after the high radiation exposure scans. Drug delivery was completed at expected timing with expected volume. For MRI the device showed significant attractive force towards the hand‐held magnet and a 50‐degree deflection angle at 50 cm from the opening of the scanner bore. No further assessment from the gradient or radiofrequency field was deemed necessary. For ultrasound the maximum magnetic field change from baseline was measured to be +11.7 μT in comparison to +74.2 μT at 4 inches from a working microwave.ConclusionsNo device performance issue was identified under the extreme test conditions in x‐ray or CT. The device was found to be MR Unsafe. Magnetic field changes around an ultrasound system met the limitation set by manufacture. Patient ultrasound scanning is considered safe as long as the transducers do not inadvertently loosen the device.
Error traps in anesthesia for fetal interventions
Ferschl, Marla B. , Rollins, Mark D. , Chatterjee, Debnath

Mayo Clinic

Pediatric Anesthesia | January 4, 2021 | Volume: 31 | Issue: 3 | Pages: 275-281

10.1111/pan.14120 | PMID 33394561 Get It

AbstractA wide range of fetal interventions are being performed worldwide to save the fetus's life, prevent permanent fetal organ damage, and allow a successful transition to extrauterine life. However, these are invasive procedures and can be associated with serious complications. This article focuses on promoting a culture of safety by highlighting five common error traps while anesthetizing patients for fetal interventions. They include failure to preserve uteroplacental perfusion and gas exchange, failure to achieve adequate uterine relaxation prior to hysterotomy, failure to monitor the fetus and prepare for fetal/neonatal resuscitation, failure to prepare for maternal hemorrhage, and failure to promptly treat uterine atony. Practical tips for avoiding these serious complications will also be discussed.
Impact of QRS Morphology on Response to Conduction System Pacing After Atrioventricular Junction Ablation
Wu, Shengjie , Cai, Mengxing, Zheng, Rujie , Wang, Songjie, Jiang, Limeng, Xu, Lei , Shi, Ruiyu, Xiao, Fangyi , Ellenbogen, Kenneth A. , Cha, Yong‐Mei , Su, Lan , Cha, Yongmei, Ellenbogen, Kenneth A , Huang, Weijian

Mayo Clinic

ESC Heart Failure | January 4, 2021 | Volume: 8 | Issue: 2 | Pages: 1195-1203

10.1002/ehf2.13181 | PMID 33395736 Get It

Abstract Aims His–Purkinje conduction system pacing (HPCSP) utilizing His (HBP) or left bundle branch pacing (LBBP) in patients with atrial fibrillation (AF) and wide QRS duration has not been well studied. We assessed the benefit of left bundle branch block (LBBB) correction during HPCSP in AF patients undergoing atrioventricular junction (AVJ) ablation with LBBB, compared with those with narrow QRS duration. Methods and results This is an observational study in consecutive patients with typical LBBB or narrow QRS duration in whom we attempted HPCSP after AVJ ablation for refractory AF with a left ventricular ejection fraction (LVEF) ≤ 50%. Echocardiographic responses and clinical outcomes were assessed at baseline and during 1 year of follow-up. A total of 178 patients were enrolled, of which 170 achieved AVJ ablation + permanent HPCSP (age 69.3 ± 10.1 years; LVEF 34.3 ± 7.7%), 133 (78.2%) patients had a narrow QRS duration, and 37 (21.2%) had an LBBB. The QRS duration changed from a baseline of 159.7 ± 16.6 ms to a paced QRS duration of 110.4 ± 12.7 ms in the LBBB cohort and from 95.6 ± 10.4 to 100.8 ± 14.5 ms (both P &lt; 0.001) in the narrow QRS cohort after AVJ ablation and pacing. Compared with the narrow QRS cohort, the LBBB cohort showed a greater absolute increase in LVEF (+22.3% vs. +14.2%, P &lt; 0.001), higher super responder rate (71.4% vs. 49.2%, P = 0.011), and greater New York Heart Association (NYHA) class improvement (−1.9 vs. −1.4, P &lt; 0.001) at 1 year. Conclusion Patients with LBBB have greater improvement in LVEF and NYHA class function than patients with narrow QRS from HPCSP after AVJ ablation.