Citations

Clear

470 citation(s) found for "Robin, Patel".

Performance of BIOFIRE FILMARRAY pneumonia panel in suspected pneumonia: insights from a real-world study
Hellou, Mona Mustafa , Virk, Abinash , Strasburg, Angel P., Harmsen, William S. , Vergidis, Paschalis , Kooda, Kirstin , Kies, Kami D., Donadio, Alexander D., Mandrekar, Jay , Schuetz, Audrey N. , Mustafa Hellou, Mona , Patel, Robin , Schuetz, Audrey N , Vergidis, Paschalis , Strasburg, Angela P., Kies, Kami D, Patel, Robin

Mayo Clinic

Microbiology Spectrum | May 22, 2025 | Volume: 13 | Issue: 7 | Pages: No page available

10.1128/spectrum.00571-25 | PMID 40401975 Get It

ABSTRACT Pneumonia may be caused by a diverse group of microorganisms; however, a microbiologic diagnosis is not universally made. Molecular tests such as the BIOFIRE FILMARRAY Pneumonia Panel (BF-PP) offer the possibility of rapid identification of potential pneumonia pathogens. This retrospective analysis was conducted as a sub-study of a recently published randomized controlled trial. Specimens from patients with suspected pneumonia were tested by the BF-PP, with results compared to cultures. The overall BF-PP positivity rate was 44.8% (252/563), and was higher [64.6% (164/254)] in specimens from patients ultimately diagnosed with pneumonia. Discrepancies between the BF-PP and cultures were most common for Streptococcus pneumoniae , Haemophilus influenzae , Moraxella catarrhalis, and Streptococcus agalactiae . Positive percent agreement (PPA) and negative percent agreement (NPA) between the BF-PP and culture were 91.4% (CI 86.3%–94.9%) and 83.6% (CI 79.5%–87.2%), respectively. For most bacteria, a correlation between high genomic abundance (genomic copies/mL) reported from the BF-PP and culture growth abundance was found. In specimens from patients ultimately diagnosed with pneumonia, clinical consistency—assessed based on whether BF-PP results aligned with associated culture results—was 79.9% and was highest for bronchoalveolar lavage fluid specimens. The BF-PP has reliable analytical performance and offers the potential advantage over conventional cultures of providing higher detection rates and more rapid results. Interestingly, despite the use of this advanced molecular diagnostic tool, one-third of pneumonia cases remained without a microbiologic etiology. IMPORTANCE This study evaluates the BIOFIRE FILMARRAY Pneumonia Panel by comparing its performance to conventional cultures in a real-world patient population (including patients ultimately diagnosed as not having pneumonia) using different types of specimens. Findings show a higher detection rate of microorganisms with the panel compared to cultures, suggesting that this test could aid in tailoring treatments for pneumonia. However, challenges remain and require further study, including distinguishing true pathogens from colonizing microorganisms and determinig why one-third of patients diagnosed with pneumonia still lacked a microbiologic etiology.
In Vitro Activity of Nisin A Against Staphylococci Isolated from Periprosthetic Joint Infection
Karau, Melissa J. , Koscianski, Christina, Badley, Andrew D. , Bedard, Nicholas A. , Zinckgraf, John W. , Patel, Robin , Koscianski, Christina A , Patel, Robin , Badley, Andrew D , Bedard, Nicholas A

Mayo Clinic

Antibiotics | May 16, 2025 | Volume: 14 | Issue: 5 | Pages: 515

10.3390/antibiotics14050515 | PMID 40426581 Get It

Background/Objectives: Staphylococci are the most common causes of periprosthetic joint infection (PJI); new antimicrobials are needed to manage these difficult infections. Nisin A is a lantibiotic peptide derived from Lactococcus lactis that has antimicrobial activity against Gram-positive bacteria, including staphylococci, and is an FDA-approved preservative used in the food and dairy industry. Here, the in vitro nisin A susceptibility of PJI-associated staphylococci was assessed. Methods: The minimum inhibitory concentrations (MICs), minimum biofilm inhibitory concentrations (MBICs), and minimum biofilm bactericidal concentrations (MBBCs) of nisin A were measured by broth microdilution against 106 staphylococcus isolates isolated from PJI. MICs were assessed using 5 × 105 CFU/mL plus nisin A. For MBICs, biofilms were grown on pegged lids for 6 h, followed by 20 h of treatment. For MBBCs, pegged lids were transferred to plates containing media only for 20 h. The results were determined as the lowest concentrations with no visual growth. Two-dimensional MICs with nisin A and vancomycin were assessed for 20 isolates. Fractional inhibitory concentrations (FICs) were calculated to determine synergistic, additive, antagonistic, or indifferent interactions. Results: The MIC that inhibited 90% of S. aureus and S. epidermidis was 4 µg/mL, apart from for the MRSA subset (8 µg/mL). The MBIC that inhibited 90% of isolates was 4 µg/mL. The MBBCs ranged from 4 to 256 µg/mL. When tested together, nisin A and vancomycin yielded an FIC between 1.25 and 1.5, indicative of indifference, except for one isolate each of MRSA and MSSA, for which an additive effect (FIC of 1) was observed. Conclusions: Nisin A showed inhibitory activity against staphylococci that cause PJI.
Fungi in the Airways: Associations With Bacterial and Mycobacterial Co-isolation in Patients With Bronchiectasis
Alitelat, Alwatheq , Aksamit, T.R., Chalmers, Sarah , Escalante, Patricio , Peikert, Tobias, Limper, A.H., Kanj, A.N., Patel, Robin , Skalski, Joseph H.

Mayo Clinic

American Journal of Respiratory and Critical Care Medicine | May 11, 2025 | Volume: 211 | Issue: Supplement_1 | Pages: A4552-A4552

10.1164/ajrccm.2025.211.abstracts.a4552 Get It

Abstract RATIONALE: Understanding co-isolation patterns between fungi and other potentially pathogenic microorganisms in the airways of bronchiectasis patients is important for uncovering possible microbial interactions and informing treatment. Although numerous organisms have been identified in respiratory cultures, the specific patterns of their co-isolation are underexplored. OBJECTIVES: To examine the patterns of co-isolation between fungi and bacteria or mycobacteria in respiratory samples from patients with bronchiectasis across a large national health system. METHODS: We reviewed 58,170 respiratory culture tests from 8,194 patients with bronchiectasis (identified using ICD-10-CM codes J47.0, J47.1, and J47.9) across Mayo Clinic. These tests were analyzed for fungal, bacterial, and mycobacterial growth, focusing on co-isolation from the same sample. Chi-square statistics were used to compute p-values. RESULTS: Of all 18,983 samples cultured for fungi, 59% were positive. Of these, 72% yielded yeasts and 40% molds. Among the 11,372 samples cultured for both fungi and bacteria, 681 (6%) showed co-isolation, representing 54% of positive bacterial cultures. The odds of bacterial co-isolation with fungi were 1.4 (95% CI: 1.3-1.6; p < 0.01), driven by yeasts (OR: 1.5, 95% CI: 1.3-1.7; p < 0.01), rather than molds (OR: 1.0, 95% CI: 0.9-1.2; p = 0.8). Pseudomonas species, the most common bacterial isolate, had a higher likelihood of co-isolation with fungi (OR: 1.6, 95% CI: 1.3-1.9; p < 0.01), particularly yeasts (OR: 1.6, 95% CI: 1.4-2.0; p < 0.01). Molds, including those from genera such as aspergillus and penicillium, did not show a significant association with the isolation of pseudomonas. On the other hand, among the 15,859 samples cultured for both fungi and mycobacteria, 1352 (9%) showed co-isolation, representing 62% of positive mycobacterial cultures. Odds of co-isolation were 1.7 (95% CI: 1.5-1.8; p < 0.01). Molds showed a stronger association with isolation of mycobacteria (OR: 1.7, 95% CI: 1.5-1.9; p < 0.01) compared to bacteria, while yeasts also had elevated odds (OR: 1.4, 95% CI: 1.2-1.5). CONCLUSIONS: Distinct patterns of fungal co-isolation with bacteria and mycobacteria have been observed in bronchiectasis, which may influence key aspects of the disease, such as inflammation and mucociliary dysfunction. Advanced metagenomic and immunoprofiling techniques could provide deeper insights into these co-isolation patterns while considering other factors like clinical demographics, previous antibiotic exposure, and disease severity. Understanding whether altering the mycobiome could modify these aspects and improve outcomes remains an important avenue for research.
Activity of contezolid against methicillin-resistant Staphylococcus aureus in a rat model of foreign body osteomyelitis
Herren, Sebastian , Karau, Melissa J. , Koscianski, Christina, Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Patel, Robin , Herren, Sebastian C , Patel, Robin , Wang, Wen

Mayo Clinic

Microbiology Spectrum | April 25, 2025 | Volume: 13 | Issue: 6 | Pages: No page available

10.1128/spectrum.02372-24 | PMID 40277362 Get It

ABSTRACT Contezolid has activity against methicillin-resistant Staphylococcus aureus (MRSA), a common cause of orthopedic infection. In a rat model of foreign body osteomyelitis, 1.3 log 10 cfu/g bone and 0.5 log 10 cfu/k-wire reduction in MRSA was found in tibiae ( P = 0.0186) and K-wires, respectively, of contezolid-treated compared to untreated rats. No MRSA was recovered from animals receiving rifampin alone or in combination with contezolid or vancomycin. There was no emergence of resistance to contezolid, vancomycin, or rifampin.
Automated whole genome sequencing platform for bacterial strain typing in clinical microbiology laboratories
Siddall, R.S., Starkey, Jordan C., Patel, Robin , Siddall, Rachel L , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | April 22, 2025 | Volume: 63 | Issue: 5 | Pages: No page available

10.1128/jcm.00178-25 | PMID 40261051 Get It

ABSTRACT Nosocomial outbreaks impact patient safety and place an economic burden on healthcare facilities. Laboratory testing plays a crucial role in outbreak investigation and guides containment efforts. In recent years, whole genome sequencing (WGS) methods have replaced traditional typing methods due to higher resolution and simplified workflows. Though an improvement from previous methods, bacterial WGS is time-consuming with manual DNA extraction and library preparation and long sequencing times for paired-end sequence data. Here, a fully automated library preparation and sequencing solution, the Clear Dx TM WGS platform (Clear Labs, San Carlos, CA), was compared to a more manual library preparation and sequencing approach using 226 isolates representing 18 bacterial species. Sequence data were analyzed using SeqSphere+ (Ridom, Münster, Germany), and the results of the two methods were compared. Of the 224 isolate sequences analyzed, 222 (99%) showed concordant isolate groupings, and, overall, the results of the two approaches were statistically similar by comparison of distance matrices. The automated workflow reduced turnaround time by 16–19 h and eliminated 3 h of manual labor while decreasing costs by an estimated 34%–57% depending on the number of isolates run. This study demonstrates the advantages of integrating automation into bacterial WGS workflows. IMPORTANCE An automated platform for bacterial nucleic acid extraction and whole genome sequencing was compared to a manual method for bacterial strain typing. The two approaches yielded nearly equivalent results, with the automated approach providing improvement in turnaround time and cost, with less manual pipetting.
Electrochemical Catheter Hub Operated by a Wearable Micropotentiostat Prevents Acinetobacter baumannii Infection In Vitro
Al‐Qurahi, Majid , Kim, Won‐Jun , Bozyel, Ibrahim , Patel, Robin , Beyenal, Haluk , Fleming, Derek , Kim, Won-Jun , Bozyel, Ibrahim , Patel, Robin , Beyenal, H , Fleming, Derek

Mayo Clinic

Biotechnology and Bioengineering | April 16, 2025 | Volume: 122 | Issue: 7 | Pages: 1828-1839

10.1002/bit.28990 | PMID 40235195 Get It

ABSTRACTIntraluminal infection of central venous catheters, used for long‐term treatment, can result in central line‐associated bloodstream infection (CLABSI). These infections can be challenging to prevent and treat due to formation of biofilms within catheter lumens, which shield bacteria from the human immune response and conventional antimicrobial therapies. Preventing bacterial colonization of catheter hubs is a strategy to prevent CLABSI. To address this, we developed a nonantibiotic, animal‐ready electrochemical catheter hub (e‐catheter hub), operated by a wearable, battery‐powered micropotentiostat (MP), that internally generates tunable hypochlorous acid (HOCl) for preventing intraluminal infection. The design evaluated three different electrode materials—titanium, platinum, and gold—for HOCl generation and biocidal activity, using working and counter electrodes of the same materials and a silver/silver chloride‐plated wire as a quasi‐reference electrode. e‐catheter hubs operated by MPs at 1.5 VAg/AgCl for 3 h generated HOCl, reducing Acinetobacter baumannii ATCC‐17978 below the detection limit (average reduction of 4.40 ± 0.05 log10 CFU/mL). The efficacy of e‐catheter hubs operated by MPs in generating HOCl and achieving biocidal activity is comparable to that of a commercial potentiostat. This study represents the first step in developing a localized, nonantibiotic strategy to mitigate CLABSI risk.
Comparative efficacy of levofloxacin, azithromycin, and doxycycline prophylaxis and treatment in an experimental Ureaplasma murine lung infection model
Al-Jabri, Maha Y. , Patel, Robin , Fleming, Derek , Patel, Robin , Fleming, Derek

Mayo Clinic

Antimicrobial Agents and Chemotherapy | April 14, 2025 | Volume: 69 | Issue: 5 | Pages: No page available

10.1128/aac.01724-24 | PMID 40227041 Get It

ABSTRACT Although lung transplant recipients who develop Ureaplasma- associated hyperammonemia syndrome are treated with Ureaplasma -targeted antibiotics, optimal therapy is incompletely defined, and typically not based on real-time antimicrobial susceptibility testing results. This study compared levofloxacin, azithromycin, and doxycycline prevention and treatment of Ureaplasma urealyticum (UU) and Ureaplasma parvum (UP) infections in an immunosuppressed murine lung infection model. For prophylaxis, mice received antibiotics before infection with UP-FS (susceptible to all study antibiotics), UP-AzmR (azithromycin-resistant), UP-LevR (levofloxacin-resistant), or UU-DoxR (doxycycline-resistant), with lung bacterial loads (color changing units [CCUs]) measured 18 hours following infection. For UP-FS, doxycycline was most active (Δ4.84 log 10 CCU/g; P = 0.0006), followed by levofloxacin (Δ2.45 log 10 CCU/g; P = 0.018), with azithromycin yielding a nonsignificant CCU reduction. Doxycycline (Δ1.9 log 10 CCU/g; P = 0.0025) and levofloxacin (Δ1.3 log 10 CCU/g; P = 0.004) showed activity against UP-AzmR. Only doxycycline showed activity against UP-LevR (Δ2.28 log 10 CCU/g; P = 0.0002), and only azithromycin showed activity against UU-DoxR (Δ0.67 log 10 CCU/g; P = 0.0175). For treatment, antibiotics were administered 24 hours following infection; doxycycline significantly reduced bacterial loads of all study isolates, except UU-DoxR. In addition, azithromycin was active against UP-LevR (Δ1.21 log 10 CCU/g reduction; P = 0.0003). In summary, except for doxycycline-resistant UU, doxycycline was active in preventing and treating Ureaplasma lung infection in immunosuppressed mice.
Addressing Spinal Implant Infections: Emerging Options and Unresolved Challenges
Tai, Don Bambino Geno , Patel, Robin , Lovecchio, Francis , Kwee, Thomas C. , Wouthuyzen‐Bakker, Marjan , Patel, Robin , Tai, Don Bambino Geno , Wouthuyzen-Bakker, Marjan

Mayo Clinic

Clinical Infectious Diseases | February 12, 2025 | Volume: 81 | Issue: 2 | Pages: e40-e40

10.1093/cid/ciaf065 | PMID 39935396 Get It

Corynebacterium mayonis sp. nov. isolated from a human blood culture
Mohammed, Hamidu T. , Koscianski, Christina, Berent, Taylor E. , Gordy, Garrett G. , Herren, Sebastian , Patel, Robin , Koscianski, Christina A, Herren, Sebastian C , Patel, Robin , Johnson, Stephen A.

Mayo Clinic

International Journal of Systematic and Evolutionary Microbiology | January 31, 2025 | Volume: 75 | Issue: 1 | Pages: No page available

10.1099/ijsem.0.006632 | PMID 39887037 Get It

A novel Corynebacterium species, strain BD556T, isolated from blood, was identified at Mayo Clinic, Rochester, MN, USA. After failing definitive identification using MALDI-ToF MS and partial 16S rRNA gene sequencing, BD556T was characterized using a polyphasic approach, including phenotypic, biochemical and whole-genome sequencing methods. BD556T was a Gram-positive rod with clubbed ends, facultatively anaerobic, catalase-positive, oxidase-negative and non-motile. Colonies were white, opaque and non-haemolytic with halo-like edges. BD556T grew at 35 °C in room air, with CO2 and under anaerobic conditions. BD556T grew well in 0 and 6% NaCl and weakly in 10% NaCl. The genome size was 2 349 779 bp with a G+C content of 60.39%. Phylogenetic analysis using 16S rRNA gene sequence analysis, average nucleotide identity and digital DNA–DNA hybridization between the genome of BD556T and the closest type strains from the Type Strain Genome Server database yielded separation values well beyond those required for species delineation. Chemotaxonomic analyses of BD556T revealed ribose, arabinose and galactose as whole-cell sugars and an A1γ meso-diaminopimelic acid-direct peptidoglycan type. The major cellular fatty acids were C15 : 0 (21.0%), C16 : 0 (14.8%), C17 : 1 ω9c (26.2%), C17 : 0 (13.3%) and C18 : 1 ω9c (18.3%). Polar lipids included diphosphatidylglycerol, phosphatidylglycerol and unidentified glycolipids and phospholipids. BD556T also contained mycolic acids (32–36 carbons) typical of corynebacteria. The respiratory quinones were dominated by MK-8(H2) (71.2%) and MK-9(H2) (25.9%), with smaller amounts of MK-7(H2) and MK-10(H2). The results presented support the tenet that BD556T (=TSD 427T=NCTC 15078T) is a novel species for which the name Corynebacterium mayonis sp. nov. is proposed.
P-1498. Contezolid is Active against Methicillin-Resistant Staphylococcus aureus in Experimental Rat Foreign Body Osteomyelitis
Karau, Melissa J. , Koscianski, Christina, Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jay , Herren, Sebastian , Patel, Robin

Mayo Clinic

Open Forum Infectious Diseases | January 29, 2025 | Volume: 12 | Issue: Supplement_1 | Pages: No page available

10.1093/ofid/ofae631.1667 Get It

Abstract Background Methicillin-resistant Staphylococcus aureus (MRSA) is a common cause of orthopedic implant-associated infection, where S. aureus can survive intracellularly and form biofilms. Vancomycin has poor activity against staphyloccoccal biofilms. Although rifampin is effective against staphylococcoal biofilms and has intracellular activity, resistance may develop when it is used as a single agent. Contezolid is a novel oxazolidinone with reported activity against S. aureus in vitro and in vivo in both murine systemic and thigh infection models. Here, we assessed the in vivo activity of contezolid, with and without rifampin, in a rat model of foreign body osteomyelitis. Figure 1. Quantities of MRSA IDRL-6169 recovered from A. tibia B. K-wire. Circles represent values from individual animals; horizontal lines represent mean values. Compared to no treatment: *p=0.0186 **p<0.0002 Methods The left tibia of 60 male Wister rats were inoculated with arachidonic acid (sclerosing agent) and 106 cfu MRSA IDRL-6169 and a K-wire implanted. After four weeks, rats received either no treatment, contezolid (50 mg/kg orally, every 12 h), rifampin (10 mg/kg intraperitoneally every 12 h), rifampin plus contezolid, or vancomycin (75 mg/kg intraperitoneally, every 12 h) plus rifampin for 21 days. Following treatment, tibiae were harvested and cyropulverized. Tibiae and K-wires were cultured separately, and results reported as log10 cfu/gram of bone or K-wire (limit of detect 0.1 log10), respectively. Wilcoxon rank-sum test and false discovery rates were performed and p< 0.05 considered significant. Results Results are shown in Figure 1. MRSA was recovered from tibiae and K-wires of all untreated animals, at means of 5.1 log10 cfu/bone and 3.0 log10 cfu/K-wire, respectively. There was a 1.0 log10 cfu/g mean reduction in MRSA recovered from the tibiae of contezolid-treated rats compared to untreated rats (p=0.0186), and a 0.2 log10 reduction on K-wires. No MRSA was recovered from the tibiae or K-wires in animals receiving rifampin, whether alone or in combination with contezolid or vancomycin. Conclusion Contezolid was active against MRSA in a rat model of foreign body osteomyelitis, reducing bacterial loads in bone, albeit not on K-wires, unless co-administered with rifampin. Disclosures Robin Patel, MD, a patent on Bordetella pertussis/parapertussis PCR issued, a patent on a device/method for sonication with royalties paid by Samsung to Mayo Clinic, a: See above|MicuRx Pharmaceuticals and BIOFIRE: Grant/Research Support|PhAST, Day Zero Diagnostics, Abbott Laboratories, Sysmex, DEEPULL DIAGNOSTICS, S.L., Netflix, Oxford Nanopore Technologies and CARB-X: Advisor/Consultant|Up-to-Date and the Infectious Diseases Board Review Course.: Honoraria