Citations

Clear

65 citation(s) found for "Fidler, Jeff".

Magnetic resonance enterography is feasible and reliable in multicenter clinical trials in patients with Crohn's disease, and may help select subjects with active inflammation
Coimbra, A. J. F. , O’Byrne, S., Lu, Timothy T. , Bengtsson, T., Crespigny, Alex de, Luca, Diana, Rutgeerts, P., Bruining, David H. , Fidler, Jeff L. , Sandborn, W. J., Santillan, Cynthia , Higgins, Peter , Al-Hawary, Mahmoud M, Vermeire, Séverine , Vanbeckevoort, Dirk, Vanslembrouck, Ragna , Peyrin‐Biroulet, Laurent , Laurent, V., Herrmann, Karin A., Rimola, Jordi , Fidler, Jeff L. , Sandborn, W.J., Al-Hawary, Mahmoud M. , Vermeire, Séverine , Panés, Julián , Peyrin-Biroulet, Laurent

Mayo Clinic

Alimentary Pharmacology & Therapeutics | November 9, 2015 | Volume: 43 | Issue: 1 | Pages: 61-72

10.1111/apt.13453 | PMID 26548868 Get It

SummaryBackgroundReliable tools for patient selection are critical for clinical drug trials.AimTo evaluate a consensus‐based, standardised magnetic resonance enterography (MRE) protocol for selecting patients for inclusion in Crohn's disease (CD) multicenter clinical trials.MethodsThis study recruited 20 patients [Crohn's Disease Activity Index (CDAI) scores: <150 (n = 8); 150–220 (n = 4); 220–450 (n = 8)], to undergo ileocolonoscopy and two MREs (with and without colonic contrast) within a 14‐day period. Procedures were scored centrally using, Magnetic Resonance Index of Activity (MaRIA), and both Crohn's Disease Endoscopic Index of Severity (CDEIS) and Simplified Endoscopic Score (SES‐CD).Results37 MREs were acquired. Both MREs were evaluable in 16 patients for calculation of test–retest and inter‐reader reliability scores. The MaRIA scores for the terminal ileum had excellent test–retest and inter‐reader reliability, with correlations >0.9. The proximal ileum showed strong within‐reader agreement (0.90–0.96), and fair between‐reader agreement (0.59–0.72). MRE procedures were tolerable. MaRIA scores correlated with CDEIS and SES‐CD (0.63 and 0.71), but not with CDAI (0.34). MRE identified 3 patients with intra‐abdominal complications, who would otherwise have been included in clinical trials. Furthermore, both MRE and ileocolonoscopy identified active bowel wall inflammation in 2 patients with CDAI <150, and none in 1 patient with CDAI > 220. Data quality was good/excellent in 85% of scans, and fair or better in 96%.ConclusionsMagnetic resonance enterography of high‐quality and reproducibility was feasible in a global multi‐ centre setting, with evidence for improved selectivity over CDAI and ileocolonoscopy in identifying appropriate CD patients for inclusion in therapeutic intervention trials.
CT Colonography for the Detection of Nonpolypoid Adenomas: Sensitivity Assessed With Restricted National CT Colonography Trial Criteria
Fidler, Jeff L. , Zhang, Zheng , Herman, B. , Dachman, Abraham H. , Heiken, Jay P. , Kuo, Mark , Menias, Christine O. , Siewert, Bettina , Cheema, Jugesh I., Obregon, Richard G., Zimmerman, Peter, Horton, Karen M., Iyer, Revathy B., Hara, Amy K., Halvorsen, Robert A., Casola, Giovanna, Burgart, Lawrence J., Johnson, C. Daniel, Fidler, Jeff L. , Limburg, Paul J. , Fletcher, Joel G. , Coakley, Kevin J. , Yee, Judy

Mayo Clinic

American Journal of Roentgenology | November 21, 2014 | Volume: 203 | Issue: 6 | Pages: W614-W622

10.2214/ajr.13.12356 | PMID 25415726 Get It

Comparison of manual and semiautomated techniques for analyzing gastric volumes with MRI in humans
Bharucha, Adil E. , Karwoski, Ronald A., Fidler, Jeff L. , Holmes, David R. , Robb, Richard A., Riederer, Stephen J. , Zinsmeister, Alan R., Fidler, Jeff, Fidler, Jeff L.

Mayo Clinic

American Journal of Physiology-Gastrointestinal and Liver Physiology | July 11, 2014 | Volume: 307 | Issue: 5 | Pages: G582-G587

10.1152/ajpgi.00048.2014 | PMID 25012844 Get It

Gastric emptying, accommodation, and motility can be quantified with magnetic resonance imaging (MRI). The first step in image analysis entails segmenting the stomach from surrounding structures, usually by a time-consuming manual process. We have developed a semiautomated process to segment and measure gastric volumes with MRI. Gastric images were acquired with a three-dimensional gradient echo MRI sequence at 5, 10, 20, and 30 min after ingestion of a liquid nutrient (Ensure, 296 ml) labeled with gadolinium in 20 healthy volunteers and 29 patients with dyspeptic symptoms. The agreement between gastric volumes measured by manual segmentation and our new semiautomated algorithm was assessed with Lin's concordance correlation coefficient (CCC) and the Bland Altman test. At 5 min after a meal, food volumes measured by manual (352 ± 4 ml) and semiautomated (346 ± 4 ml) techniques were correlated {CCC[95% confidence interval (CI)] 0.70 (0.52, 0.81)}; air volumes measured by manual (88 ± 6 ml) and semiautomated (84 ± 6 ml) techniques were also correlated [CCC (95% CI) 0.89 (0.82, 0.94)]. Findings were similar at subsequent time points. The Bland Altman test was not significant. The time required for semiautomated segmentation ranged from an average of 204 s for the 5-min images to 233 s for the 20-min images. These times were appreciably smaller than the typical times of many tens of minutes, even hours, required for manual segmentation. To conclude, a semiautomated process can measure gastric food and air volume using MRI with comparable accuracy and far better efficiency than a manual process.
Putting the Fat and Water Protons to Work for You: A Demonstration Through Clinical Cases of How Fat-Water Separation Techniques Can Benefit Your Body MRI Practice
Rampton, Joshua W., Young, Phillip M. , Fidler, Jeff L. , Hartman, Robert P. , Herfkens, Robert J., Fidler, Jeff L.

Mayo Clinic

American Journal of Roentgenology | November 21, 2013 | Volume: 201 | Issue: 6 | Pages: 1303-1308

10.2214/ajr.13.10606 | PMID 24261371 Get It

Noncathartic CT Colonography: Image Quality Assessment and Performance and in a Screening Cohort
Silva, Alvin C. , Fidler, Jeff L. , Cernigliaro, Joseph G. , Wilson, Lynn A., Engelby, Trudy A., Spencer, Garrett, Harmsen, William S. , Mandrekar, Jay , Johnson, C. Daniel, Fletcher, Joel G. , Fidler, Jeff L. , Manduca, Armando , Limburg, Paul J.

Mayo Clinic

American Journal of Roentgenology | September 24, 2013 | Volume: 201 | Issue: 4 | Pages: 787-794

10.2214/ajr.12.9225 | PMID 24059367 Get It

Individualization of Abdominopelvic CT Protocols With Lower Tube Voltage to Reduce IV Contrast Dose or Radiation Dose
Hough, David M., Yu, Lifeng , Shiung, Maria M., Carter, Rickey E. , Geske, Jennifer R. , Fidler, Jeff L. , Huprich, James E., Jondal, Dayna, Yu, Lifeng , Leng, Shuai , Fidler, Jeff L. , McCollough, Cynthia H. , Fletcher, Joel G. , Carter, Rickey E , Geske, Jennifer

Mayo Clinic

American Journal of Roentgenology | June 21, 2013 | Volume: 201 | Issue: 1 | Pages: 147-153

10.2214/ajr.12.9295 | PMID 23789669 Get It

Multiphase CT Enterography Evaluation of Small-Bowel Vascular Lesions
Huprich, James E., Barlow, John M. , Hansel, Stephanie L. , Alexander, Jeffrey A. , Fidler, Jeff L. , Fidler, Jeff L. , Hansel, Stephanie L

Mayo Clinic

American Journal of Roentgenology | June 21, 2013 | Volume: 201 | Issue: 1 | Pages: 65-72

10.2214/ajr.12.10414 | PMID 23789659 Get It

Prospective Assessment of Dynamic CT and MR Cholangiography in Functional Biliary Pain
Fidler, Jeff L. , Knudsen, John M. , Collins, Douglas A. , McGee, Kiaran P. , Lahr, Brian D. , Thistle, Johnson L., Topazian, Mark , Fidler, Jeff L.

Mayo Clinic

American Journal of Roentgenology | May 31, 2013 | Volume: 201 | Issue: 2 | Pages: W271-W282

10.2214/ajr.12.9538 | PMID 23724800 Get It

Intraductal Papillary Mucinous Neoplasms of the Pancreas: CT Patterns of Recurrence and Multiobserver Performance in Detecting Recurrent Neoplasm After Surgical Resection
Christensen, Jared A. , Fidler, Jeff L. , Wold, Peter B., Binstock, Aaron J., Smyrk, Thomas C. , Harmsen, Scott, Crownhart, Brian S., Chari, Suresh T. , Fletcher, Joel G. , Fidler, Jeff L. , Chari, Suresh T

Mayo Clinic

American Journal of Roentgenology | February 28, 2013 | Volume: 183 | Issue: 5 | Pages: 1367-1374

10.2214/ajr.183.5.1831367 | PMID 15505305 Get It

Preoperative Detection of Pancreatic Insulinomas on Multiphasic Helical CT
Fidler, Jeff L. , Reading, Carl C., Andrews, James C. , Thompson, Geoffrey B. , Grant, Clive S., Service, F. John, Fidler, Jeff L. , Fletcher, Joel G.

Mayo Clinic

American Journal of Roentgenology | February 28, 2013 | Volume: 181 | Issue: 3 | Pages: 775-780

10.2214/ajr.181.3.1810775 | PMID 12933480 Get It