Citations

Clear

343 citation(s) found for "Asirvatham, Samuel J".

Mitral valve prolapse: arrhythmic risk during pregnancy and postpartum
Sabbag, Avi , Aabel, Eivind W. , Castrini, Anna Isotta , Siontis, Konstantinos C. , Duthoit, Guillaume , Asirvatham, Samuel J. , Sehrawat, Ojasay, Kirkels, Feddo P. , Rav, Moshe , Peichl, Petr , Lim, H. , Martins, Raphaël P. , Font, Jonaz , Truong, Nguyen Ngoc Khoi , Estensen, Mette E , Laredo, Mikael , Duthoit, Guillaume , Kirkels, Feddo P , Beinart, Roy , Peichl, Petr , Sohns, Christian , Haugaa, Kristina , Asirvatham, Samuel J , Martins, Raphael , Aabel, Eivind W , Sabbag, Avi , Nizard, J. , Rosendael, Philippe J. van , Beinart, Roy , Haugaa, Kristina H.

Mayo Clinic

European Heart Journal | May 14, 2024 | Volume: 45 | Issue: 20 | Pages: 1831-1839

10.1093/eurheartj/ehae224 | PMID 38740526 Get It

Abstract Background and Aims Arrhythmic mitral valve prolapse (AMVP) is linked to life-threatening ventricular arrhythmias (VAs), and young women are considered at high risk. Cases of AMVP in women with malignant VA during pregnancy have emerged, but the arrhythmic risk during pregnancy is unknown. The authors aimed to describe features of women with high-risk AMVP who developed malignant VA during the perinatal period and to assess if pregnancy and the postpartum period were associated with a higher risk of malignant VA. Methods This retrospective international multi-centre case series included high-risk women with AMVP who experienced malignant VA and at least one pregnancy. Malignant VA included ventricular fibrillation, sustained ventricular tachycardia, or appropriate shock from an implantable cardioverter defibrillator. The authors compared the incidence of malignant VA in non-pregnant periods and perinatal period; the latter defined as occurring during pregnancy and within 6 months after delivery. Results The authors included 18 women with AMVP from 11 centres. During 7.5 (interquartile range 5.8–16.6) years of follow-up, 37 malignant VAs occurred, of which 18 were pregnancy related occurring in 13 (72%) unique patients. Pregnancy and 6 months after delivery showed increased incidence rate of malignant VA compared to the non-pregnancy period (univariate incidence rate ratio 2.66, 95% confidence interval 1.23–5.76). Conclusions The perinatal period could impose increased risk of malignant VA in women with high-risk AMVP. The data may provide general guidance for pre-conception counselling and for nuanced shared decision-making between patients and clinicians.
Abstract 13698: Prognostic Value of Left Atrial Volume and Reservoir Function at 3-months Post-Procedure in 792 Patients Undergoing Catheter Ablation for Atrial Fibrillation
Wen, Songnan , Lin, Grace, Asirvatham, Samuel, Pislaru, Sorin V. , Kane, Garvan C. , Pislaru, Cristina

Mayo Clinic

Circulation | April 23, 2024 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.13698 Get It

Introduction: The predictive value of left atrial (LA) volume and reservoir function (ResF) post-atrial fibrillation (AF) ablation has been scarcely studied. Hypothesis: Abnormal LA volume and ResF post-ablation are associated with adverse cardiovascular events. Methods: We analyzed LA maximum (LAVImax) and minimum (LAVImin) volume index, and 2 measures of ResF, emptying fraction (LAEF) and expansion index (LAEI), prospectively measured at 3-month post-procedure in patients in sinus rhythm who underwent AF ablation between 2007-2016. Composite endpoint (CE) at follow up was all-cause mortality, cardiac hospitalization (heart failure or acute ischemic event) and stroke. Results: 792 patients were studied ( age 60±10 years, 25% women ; Table 1) . Over 7.5 years [IQR 3.0-9.7], 96 (12%) patients experienced CE, which was more prevalent in patients with enlarged LA and reduced ResF. Impaired LA volumes and ResF were each independently associated with CE ( Fig.1 ), even after adjustment for clinical, demographic and echo characteristics (Model A, Fig.2 ) (LAVImax ≥35 ml/m 2 : HR 2.15 [95% CI, 1.35-3.43], p=0.001; LAVImin≥20.5 ml/m 2 : HR 2.88 [1.77-4.69], p<0.0001; LAEF<39%: HR 2.00 [1.31-3.05], p=0.001; LAEI<65%: HR 1.95 [1.27-3.01], p=0.003). ResF measures (LAEF and LAEI) were incremental to LAVImax (all p<0.05), but not LAVImin (all p>0.05; Fig.2 ). In patients with normal LA (LAVImax <35 ml/m 2 ; n=408), increased LAVImin (≥20.5 ml/m 2 ) remained associated with CE (HR 3.11 [1.45-6.67], p=0.004) and cardiac hospitalization (HR 5.81 [1.87-18.01], p=0.002). These findings were independent of AF recurrence. Conclusions: In these patients, enlarged LA and impaired ResF at 3-month post-ablation were strongly associated with adverse cardiovascular outcomes, regardless of AF recurrence. Measures of LA ResF were incremental to LAVImax. Notably, LAVImin showed the strongest associations and even identified a high-risk subgroup among patients with non-dilated LA.
Abstract 13068: Use of Cardiac Implantable Electronic Devices in Carcinoid Heart Disease
Shabtaie, Samuel A. , Connolly, Heidi M. , Miranda, William R. , Shen, Win-Kuang, Cha, Yong‐Mei , Asirvatham, Samuel, Deshmukh, Abhishek , Ward, Robert C. , Luis, Sushil Allen , Pellikka, Patricia A. , Schaff, Hartzell V. , DeSimone, Christopher V.

Mayo Clinic

Circulation | April 23, 2024 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.13068 Get It

Introduction: Carcinoid heart disease (CHD) is a rare sequelae of hormonally active neuroendocrine tumors that often requires cardiac surgical intervention. Little is reported on cardiac implantable electronic device (CIED) implantation in the CHD patient population. Hypothesis: We sought to establish the safety and efficacy of CIED implantation in patients with CHD. Methods: We retrospectively reviewed patients with a diagnosis of CHD who underwent CIED implantation at our institution (Mayo Clinic) and evaluated indications for implant, perioperative complications, and mortality. Results: A total of 27 patients with a cumulative follow up of 75 patient-years were identified during the study period. The most common indication for device implant was high grade atrioventricular block (n=18, 66.7%). 14 (51.8%) had baseline conduction disease and 26 (96.2%) underwent cardiac surgery prior to CIED implant. The majority of devices implanted were dual chamber permanent pacemakers (PPM) (n=17, 63.0%), while other devices included single chamber PPM, epicardial PPM, chronic resynchronization devices, and intracardiac defibrillators. Peri-operative complication occurred in 6 patients (22.2%), with 2 patients requiring ICU level care. No patient suffered carcinoid crisis during implantation and there was no peri-implant mortality. Long term, 3 patients required device extraction: 1 for infection, 1 for lead related pain, and 1 for generator migration. The median time to death from implant was 2.5 years, with one-year mortality at 15%. Conclusions: In this unique cohort of patients with CHD, CIED can be performed safely. CIED most often occurred in the post cardiac surgical period and carcinoid crisis was uncommon.
Abstract 16621: Holter Monitoring in Patients With Left Ventricular Noncompaction
Vaidya, Vaibhav R. , Lyle, Melissa , Deshmukh, Abhishek , Foley, Thomas A. , Connolly, Heidi M. , Melduni, Rowlens M. , Farwati, Medhat , Isath, Ameesh , Asirvatham, Samuel J. , Michelena, Héctor I. , Kapa, Suraj

Mayo Clinic

Circulation | April 23, 2024 | Volume: 138 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.138.suppl_1.16621 Get It

Introduction: Multiple arrhythmias including ventricular tachycardia (VT) and atrial fibrillation (AF) have been reported in patients with left ventricular noncompaction (LVNC). We sought to determine the frequency of rhythm abnormalities on Holter monitoring, and their association with all-cause mortality, in patients with LVNC. Methods: Imaging databases from 2000-2016 were reviewed to identify patients with LVNC. On transthoracic echocardiography (TTE), LVNC was defined as: end systolic noncompacted: compacted (NC:C) ratio>2 and end diastolic epicardium to trough: epicardium to peak trabeculation (X:Y) ratio<0.5. Holter monitor reports from the medical record were evaluated. VT was defined as ≥3 consecutive beats of ventricular origin. All-cause mortality was obtained from a web-based research and location service (Accurint). We used a proportional hazards model to determine associations of Holter variables with all-cause mortality. Results: Among 340 LVNC patients, Holter reports were available for 177 patients (median age 45 years, interquartile range [IQR] 33-61; 45% females). On TTE, the median NC:C ratio was 2.7 (IQR 2.4-3.2) and X:Y ratio was 0.25 (IQR 0.20-0.28). The median ejection fraction (EF) was 48% (IQR 33-58). 48 patients (27%) had at least one episode of VT (median 4 episodes, IQR 2-4). The median longest duration of VT was 5 beats (IQR 4-9) and maximum rate was 148 beats per minute (IQR: 125-169). PVC burden >5% and 20% was present in 13% and 5% of patients respectively. Patients with EF<50% were more likely to have VT (43% vs 16%, p=0.0003) and PVC burden >5% (19% vs 7%, p=0.03). AF was infrequent (N=5, all persistent). All-cause mortality was 12% over median 6.9 years of follow up (IQR: 3.6-11.3 years). Presence of VT and PVC burden on Holter monitoring were not associated with all-cause mortality (p>0.05). Among patients with VT, the number, longest duration, and fastest rate of VT episodes were not associated with all-cause mortality. Conclusions: Ventricular tachycardia on Holter monitoring is common among patients with LVNC, especially those with a reduced EF. However, the clinical significance of this finding is uncertain, and presence of VT was not associated with long term all-cause mortality.
Abstract 15661: Clinical Predictors and Financial Implications of Permanent Pacemaker Implantation in Patients Undergoing TAVR: A Nationwide study
Deshmukh, Abhishek , Pant, Sadip, Patel, Nileshkumar , Savani, Chirag, Arora, Shilpkumar , Patel, Nilay , Desai, Maheshkumar, Bhimani, Ronak , Badheka, Apurva O., Padmanabhan, Deepak , Friedman, Paul A. , Turakhia, Minang, Rihal, Charanjit S. , Patel, Samir , Turakhia, Minang, Cha, Yong Mei, Asirvatham, Samuel J. , Rihal, Charanjit S. , Noseworthy, Peter A.

Mayo Clinic

Circulation | April 23, 2024 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.15661 Get It

Introduction: The treatment options for high and extreme-risk patients with severe symptomatic aortic stenosis have changed significantly over the past decade because of advances in transcatheter aortic valve replacement (TAVR). However new permanent pacemaker implant (PPI) remains an impending concern after TAVR. Hypothesis: We sought to determine the frequency, predictors and outcomes of patients requiring PPI after TAVR. Methods: We queried the National Inpatient Sample (NIS) database using the ICD-9-CM procedure code of 35.05 for transfemoral/transaortic and 35.06 for transapical replacement of aortic valve .We identified TAVR procedures associated with new permanent pacemaker implants using appropriate validated ICD-9-CM codes. Using multivariate analysis we further identified predictors of PPM implants Results: An estimated 8828 TAVR procedures were performed in United States between 2011-2012. 773 (8.7%) TAVR procedures were associated with PPIs. PPI were higher in older (age>80 years), White race, diabetics, left bundle branch block (LBBB), right bundle branch block (RBBB), transfemoral approach. The inhospital mortality ( 5.2% vs.4.6% ) , mean length of stay ( 9.8 vs. 8.3 days ) disposition to short term nursing facility was higher (38.2% vs. 32.1%) and mean total costs (82217$ vs. 52283$) was higher in TAVR + PPI group . On multivariate analysis, Age in 5 year increment [Odds ratio (OR) 1.11; Confidence interval (CI) 1.05-1.17, p<0.001], diabetes [OR 1.26; CI 1.07-1.49, p<0.001], LBBB [OR 1.99; CI 1.55-2.56, p<0.001], RBBB [OR 5.36; CI 3.80-7.55, p<0.001] were independent predictors of PPI. Transfemoral approach was associated with more PPI implants [OR 1.41; CI 1.12 -1.78, p<0.001] Conclusion: Age, baseline conduction system disturbances, diabetes, transfemoral approach emerged as independent predictors of PPI after TAVR. This study provides useful tools to identify high-risk patients for PPI after TAVR.
Abstract 12054: Electro-anatomic Mapping Guided Endomyocardial Biopsy: A Systematic Review
Vaidya, Vaibhav, Deshmukh, Abhishek , Vasudevan, Krithika , Packer, Douglas L. , Farrell, Ann , Cooper, Leslie T. , Kapa, Suraj , Noseworthy, Peter A. , Asirvatham, Samuel J.

Mayo Clinic

Circulation | April 23, 2024 | Volume: 134 | Issue: suppl_1 | Pages: No page available

10.1161/circ.134.suppl_1.12054 Get It

Introduction: Electro-anatomic mapping (EAM) has been studied as a modality to improve the sensitivity and reduce false negative rates with endomyocardial biopsy (EMB). We systematically reviewed the literature describing EAM guided EMB. Methods: An experienced librarian developed search strategies for Ovid MEDLINE, Ovid Embase, Ovid CDR, Cochrane Central, Scopus and Web of Science. There were no restrictions on language or publication date. Animal studies were excluded. Search strategy included MESH headings and keywords including endomyocardial biopsy and electroanatomic mapping. Results: Out of 139 studies initially identified, 16 (9 case series, 7 case reports) were included in this systematic review. EAM guided EMB was performed in 152 patients and results of 241 biopsies were available for analysis. The most common indications for EAM guided EMB were suspected arrhythmogenic right ventricular cardiomyopathy (ARVC), myocarditis and cardiac sarcoidosis (CS). While fluoroscopic visualization of the bioptome close to mapping catheter was the most commonly utilized biopsy technique (n=7 studies), direct visualization of bioptome on CARTO (n=4) and on NavX (n=2) were used as well. Low voltage areas had abnormal myocardial histology more commonly (range 60-100%) than normal voltage areas (range 11-52%). Sensitivity of low voltage areas for abnormal myocardium ranged from 60% to 82%. EAM guided EMB appears safe and adverse events were noted in only one study (remote hemopericardium). Conclusions: EAM guided EMB is a safe and efficacious method to improve the sensitivity and reduce the false negative rate of conventional fluoroscopy guided biopsy.
Abstract 9770: Anatomic Findings and Myocardial Extensions Into the Thoracic Venous Connections of the Heart
Lachman, Nirusha , Edwards, William D. , Gami, Apoor S., Talreja, Deepak, Friedman, Paul A. , Munger, Thomas M. , Hammill, Stephen C., Packer, Douglas L. , DeSimone, Christopher V. , Noheria, Amit , Asirvatham, Samuel J.

Mayo Clinic

Circulation | April 23, 2024 | Volume: 124 | Issue: suppl_21 | Pages: No page available

10.1161/circ.124.suppl_21.a9770 Get It

Introduction: Cardiac veins serve as substrate for arrhythmogenesis, and are especially involved as foci in atrial fibrillation. Understanding cardiac vein anatomy along with myocardial extension into these structures can improve electrophysiological mapping and electrical isolation of arrhythmogenic substrate. Accurately defining cardiac vein anatomy is critical in improving success of ablation therapy for atrial fibrillation. Methods: We performed measurements on 620 formalin-fixed autopsy hearts explanted from October 1998 to July 2003. The integrity of the thoracic veins and their cardiac connections were examined and systematic measurements of the superior and inferior vena cavae, azygous vein, vein of Marshall, coronary sinus, and pulmonary veins were performed and data were analyzed using univariate statistics. Results: We found that muscular extensions into the pulmonary veins were visible in 99% of the examined hearts, and were circumferential around the vein ostia (99.6%). Muscle extension into the SVC was found in 78% of examined hearts. These extensions were largely circumferential around the ostium (39%), but were also found to be asymmetric in a majority of hearts. Asymmetry was found in hearts with longer muscle extensions; no symmetry was observed in extensions greater than 0.8cm. Muscle extensions into the IVC were not seen. Occasionally, macroscopic muscle extensions into the azygous vein were visible (6%). The vein of Marshall was found to be patent to probing in the majority of hearts examined (72%) and was almost always overlying the lateral left atrial endocardial ridge. Conclusions: Our data suggest that all pulmonary veins need to be electrically isolated during atrial fibrillation ablation because of the almost universal presence of myocardial tissue extending into the veins. Mapping of the SVC should be done circumferentially and if potentials are noted isolation should also be performed. The IVC did not have muscle extensions and is unlikely to be a site of arrhythmogenesis. The azygous vein occasionally had muscle extensions and thus requires mapping and possible isolation. The vein of Marshall can be a substrate for arrhythmogenesis and is accessible for ablation by targeting the lateral left atrial endocardial ridge.
Unlocking the potential of artificial intelligence in electrocardiogram biometrics: age-related changes, anomaly detection, and data authenticity in mobile health platforms
Mangold, Kathryn, Carter, Rickey E. , Siontis, Konstantinos C. , López-Jiménez, Francisco , Asirvatham, Samuel J. , Friedman, Paul A. , Attia, Zachi I. , Mangold, Kathryn E , Lopez-Jimenez, Francisco , Attia, Zachi I , Asirvatham, Samuel J , Carter, Rickey E , Noseworthy, Peter A.

Mayo Clinic

European Heart Journal - Digital Health | April 22, 2024 | Volume: 5 | Issue: 3 | Pages: 314-323

10.1093/ehjdh/ztae024 | PMID 38774362 Get It

Abstract Aims Mobile devices such as smartphones and watches can now record single-lead electrocardiograms (ECGs), making wearables a potential screening tool for cardiac and wellness monitoring outside of healthcare settings. Because friends and family often share their smart phones and devices, confirmation that a sample is from a given patient is important before it is added to the electronic health record. Methods and results We sought to determine whether the application of Siamese neural network would permit the diagnostic ECG sample to serve as both a medical test and biometric identifier. When using similarity scores to discriminate whether a pair of ECGs came from the same patient or different patients, inputs of single-lead and 12-lead medians produced an area under the curve of 0.94 and 0.97, respectively. Conclusion The similar performance of the single-lead and 12-lead configurations underscores the potential use of mobile devices to monitor cardiac health.
Long‐term outcomes with abandoning versus extracting sterile leads: A 10‐year population‐based study
Lee, Justin Z. , Talaei, Fahimeh , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Asirvatham, Samuel J. , Kusumoto, Fred , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Valverde, Arturo, Asirvatham, Samuel J , Kusumoto, Fred M , Cha, Yong-Mei , Srivathsan, Komandoor

Mayo Clinic

Pacing and Clinical Electrophysiology | March 16, 2024 | Volume: 47 | Issue: 5 | Pages: 626-634

10.1111/pace.14940 | PMID 38488756 Get It

Abstract Background Long‐term outcomes of sterile lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) remain unclear. Methods We performed a retrospective study of a population residing in southeastern Minnesota with follow‐up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE of sterile leads from January 1, 2000, to January 1, 2011, and had follow‐up for at least 10 years or until their death were included. Results A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. Indications for subsequent lead extraction arose in 9.1% ( n = 14) of patients with initial LA and 5.3% ( n = 1) in patients with initial TLE, after an average of 7 years. Moreover, 28.6% of patients in the LA cohort who required subsequent extraction did not proceed with the extraction, and among those who proceeded, 60% had clinical success and 40% had a clinical failure. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges (5.2% vs. 5.3%). There was no difference in 10‐year survival probability among the LA group and the TLE group ( p = .64). Conclusion An initial lead abandonment strategy was associated with more complicated subsequent extraction procedures compared to patients with an initial transvenous lead extraction strategy. However, there was no difference in 10‐year survival probability between both lead management approaches.
First‐in‐man report of transsubclavian venous implantation of the Aveir leadless cardiac pacing system
Ward, Robert C. , Amin, Hina , Noseworthy, Peter A. , Asirvatham, Samuel J. , Friedman, Paul A. , Mulpuru, Siva K. , Balanescu, Dinu V , Ward, Robert C , Noseworthy, Peter A , Asirvatham, Samuel J , Friedman, Paul A , Mulpuru, Siva K , Balanescu, Dinu Valentin

Mayo Clinic

Journal of Cardiovascular Electrophysiology | March 11, 2024 | Volume: 35 | Issue: 5 | Pages: 1041-1045

10.1111/jce.16241 | PMID 38462703 Get It

Abstract Introduction Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. Methods and Results Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same‐day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. Conclusions We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.