Citations

Clear

4848 citation(s) found for "Wu, Eric".

Frozen Section Pathology for Decision Making in Parotid Surgery
Olsen, Kerry D., Moore, Eric J. , Lewis, Jean E.

Mayo Clinic

JAMA Otolaryngology–Head & Neck Surgery | March 10, 2014 | Volume: 139 | Issue: 12 | Pages: 1275

10.1001/jamaoto.2013.5217 | PMID 24136579 Get It

Salvage Surgery for Recurrent Cancers of the Oropharynx
White, Hilliary N., Ford, Samuel E. , Bush, Benjamin , Moore, Eric J. , Ghanem, Tamer , Carroll, William R. , Rosenthal, Eben L. , Sweeny, Larissa , Magnuson, J. Scott , Holsinger, F. Christopher , Sweeny, Larissa , Rosenthal, Eben L

Mayo Clinic

JAMA Otolaryngology–Head & Neck Surgery | March 10, 2014 | Volume: 139 | Issue: 8 | Pages: 773

10.1001/jamaoto.2013.3866 | PMID 23949352 Get It

Analysis of Postoperative Bleeding and Risk Factors in Transoral Surgery of the Oropharynx
Pollei, Taylor R., Hinni, Michael L., Moore, Eric J. , Hayden, Richard E. , Olsen, Kerry D., Casler, John D., Walter, Logan C.

Mayo Clinic

JAMA Otolaryngology–Head & Neck Surgery | March 10, 2014 | Volume: 139 | Issue: 11 | Pages: 1212

10.1001/jamaoto.2013.5097 | PMID 24113922 Get It

Functions of flt3 in zebrafish hematopoiesis and its relevance to human acute myeloid leukemia
He, Bai‐Liang , Shi, Xiangguo , Man, Cheuk Him , C.H., Alvin, Ekker, Stephen C. , Chow, Howard C.H., So, Chi Wai Eric , Choi, William W.L., Leung, Anskar Y.H. , Zhang, Wenqing , Zhang, Yiyue , Alvin, C. H. , Ekker, Stephen C

Mayo Clinic

Blood | March 4, 2014 | Volume: 123 | Issue: 16 | Pages: 2518-2529

10.1182/blood-2013-02-486688 | PMID 24591202 Get It

Key Points Zebrafish flt3 plays an important role in the initiation of definitive hematopoietic stem cells. Expression of human FLT3-ITD activates endogenous flt3 signaling and induces myeloid expansion.
Intraoperative image-guided spinal navigation: technical pitfalls and their avoidance
Rahmathulla, Gazanfar , Nottmeier, Eric W. , Pirris, Stephen M. , Deen, H. Gordon , Pichelmann, Mark A.

Mayo Clinic

Neurosurgical Focus | March 1, 2014 | Volume: 36 | Issue: 3 | Pages: E3

10.3171/2014.1.focus13516 | PMID 24580004 Get It

Spinal instrumentation has made significant advances in the last two decades, with transpedicular constructs now widely used in spinal fixation. Pedicle screw constructs are routinely used in thoracolumbar-instrumented fusions, and in recent years, the cervical spine as well. Three-column fixations with pedicle screws provide the most rigid form of posterior stabilization. Surgical landmarks and fluoroscopy have been used routinely for pedicle screw insertion, but a number of studies reveal inaccuracies in placement using these conventional techniques (ranging from 10% to 50%). The ability to combine 3D imaging with intraoperative navigation systems has improved the accuracy and safety of pedicle screw placement, especially in more complex spinal deformities. However, in the authors' experience with image guidance in more than 1500 cases, several potential pitfalls have been identified while using intraoperative spinal navigation that could lead to suboptimal results. This article summarizes the authors' experience with these various pitfalls using spinal navigation, and gives practical tips on their avoidance and management.
Two‐year seizure reduction in adults with medically intractable partial onset epilepsy treated with responsive neurostimulation: Final results of the RNS System Pivotal trial
Heck, Christianne, King‐Stephens, David , Nair, Dileep , Jobst, Barbara C. , Barkley, Gregory L., Salanova, Vicenta , Gwinn, Ryder P. , Skidmore, Christopher , Ness, Paul C. Van, Bergey, Gregory K. , Park, Yong D., Miller, Ian , Geller, Eric B., Rutecki, Paul , Zimmerman, Richard S. , Spencer, David , Leiphart, James W., Wharen, Robert E. , Fessler, James, Fountain, Nathan B. , Eisenschenk, Stephan, Duckrow, Robert B., Hirsch, Lawrence J. , Bazil, Carl W., O’Donovan, Cormac A. , Sun, Felice T., Courtney, Tracy A., Seale, Cairn G. , Morrell, Martha J. , Massey, Andrew D. , Cole, Andrew J. , Smith, Michael C. F. , Goldman, Alica M. , Edwards, Jonathan , Worrell, Gregory A. , Gross, Robert E. , Fountain, Nathan , Hirsch, Lawrence J , Jobst, Barbara , Nair, Dileep R , Skidmore, Christopher , Morrell, Martha J

Mayo Clinic

Epilepsia | February 24, 2014 | Volume: 55 | Issue: 3 | Pages: 432-441

10.1111/epi.12534 | PMID 24621228 Get It

Summary Objective To demonstrate the safety and effectiveness of responsive stimulation at the seizure focus as an adjunctive therapy to reduce the frequency of seizures in adults with medically intractable partial onset seizures arising from one or two seizure foci. Methods Randomized multicenter double‐blinded controlled trial of responsive focal cortical stimulation (RNS System). Subjects with medically intractable partial onset seizures from one or two foci were implanted, and 1 month postimplant were randomized 1:1 to active or sham stimulation. After the fifth postimplant month, all subjects received responsive stimulation in an open label period ( OLP ) to complete 2 years of postimplant follow‐up. Results All 191 subjects were randomized. The percent change in seizures at the end of the blinded period was −37.9% in the active and −17.3% in the sham stimulation group (p = 0.012, Generalized Estimating Equations). The median percent reduction in seizures in the OLP was 44% at 1 year and 53% at 2 years, which represents a progressive and significant improvement with time (p < 0.0001). The serious adverse event rate was not different between subjects receiving active and sham stimulation. Adverse events were consistent with the known risks of an implanted medical device, seizures, and of other epilepsy treatments. There were no adverse effects on neuropsychological function or mood. Significance Responsive stimulation to the seizure focus reduced the frequency of partial‐onset seizures acutely, showed improving seizure reduction over time, was well tolerated, and was acceptably safe. The RNS System provides an additional treatment option for patients with medically intractable partial‐onset seizures.
Kinetic analysis of anterior cervical discectomy and fusion supplemented with transarticular facet screws
Traynelis, Vincent C. , Sherman, Jonathan D., Nottmeier, Eric W. , Singh, Vaneet, McGilvray, Kirk C. , Puttlitz, Christian M. , Leahy, P. Devin , McGilvray, Kirk

Mayo Clinic

Journal of Neurosurgery: Spine | February 21, 2014 | Volume: 20 | Issue: 5 | Pages: 485-491

10.3171/2014.1.spine13837 | PMID 24559463 Get It

Object The clinical success rates of anterior cervical discectomy and fusion (ACDF) procedures are substantially reduced as more cervical levels are included in the fusion procedure. One method that has been proposed as an adjunctive technique for multilevel ACDF is the placement of screws across the facet joints (“transfacet screws”). However, the biomechanical stability imparted by transfacet screw placement (either unilaterally or bilaterally) has not been reported. Therefore, the purpose of this study was to determine the acute stability conferred by implementation of unilateral and bilateral transfacet screws to an ACDF construct. Methods Eight C2–T1 fresh-frozen human cadaveric spines (3 female and 5 male; mean age 50 years) were tested. Three different instrumentation variants were performed on cadaveric cervical spines across C4–7: 1) ACDF with an intervertebral spacer and standard plate/screw instrumentation; 2) ACDF with an intervertebral spacer and standard plate/screw instrumentation with unilateral facet screw placement; and 3) ACDF with an intervertebral spacer and standard plate/screw instrumentation with bilateral facet screw placement. Kinetic ranges of motion in flexion-extension, lateral bending, and axial rotation at 1.5 Nm were captured after each of these procedures and were statistically analyzed for significance. Results All 3 fixation scenarios produced statistically significant reductions (p < 0.05) in all 3 bending planes compared with the intact condition. The addition of a unilateral facet screw to the ACDF construct produced significant reductions at the C4–5 and C6–7 levels in lateral bending and axial rotation but not in flexion-extension motion. Bilateral facet screw fixation did not produce any statistically significant decreases in flexion-extension motion compared with unilateral facet screw fixation. However, in lateral bending, significant reductions at the C4–5 and C5–6 levels were observed with the addition of a second facet screw. The untreated, adjacent levels (C2–3, C3–4, and C7–1) did not demonstrate significant differences in range of motion. Conclusions The data demonstrated that adjunctive unilateral facet screw fixation to an ACDF construct provides significant gains in stability and should be considered a potential option for increasing the likelihood for obtaining a successful arthrodesis for multilevel ACDF procedures.
Linked distal radioulnar joint arthroplasty: an analysis of the APTIS prosthesis
Fox, Tyler J. , Wagner, Eric R. , Berger, Richard A. , Kakar, Sanjeev , Wagner, Eric R

Mayo Clinic

Journal of Hand Surgery (European Volume) | February 19, 2014 | Volume: 39 | Issue: 7 | Pages: 739-744

10.1177/1753193414523189 | PMID 24554688 Get It

Painful radioulnar convergence following resection of the distal ulna can produce substantial disability and prove a challenging surgical problem, particularly in the revision setting. The purpose of this study was to evaluate the outcome of a series of patients with chronic distal radioulnar joint instability or multiple prior procedures treated with linked distal radioulnar joint arthroplasty with the APTIS prosthesis. A series of ten patients were identified with a mean follow up of 4.0 years. At final follow-up nine of ten implants survived free from revision or removal, with patients experiencing good pain relief and functional outcomes, with reasonable overall satisfaction in all seven patients who returned the questionnaires. Despite the medium-term follow-up and small number of patients, our results suggest the linked distal radioulnar joint arthroplasty may be a viable option for treating painful radioulnar convergence following multiple failed procedures at the distal radioulnar joint.
A case series on the technical use of three-dimensional image guidance in subaxial anterior cervical surgery
Pirris, Stephen M. , Nottmeier, Eric W.

Mayo Clinic

The International Journal of Medical Robotics and Computer Assisted Surgery | February 13, 2014 | Volume: 11 | Issue: 1 | Pages: 44-51

10.1002/rcs.1571 | PMID 24523103 Get It