Citations

Clear

62 citation(s) found for "Srivathsan, Komandoor".

Abstract 14411: Block in the Fasciculoventricular Pathway in a Complex Arrhythmia Presentation
Suppah, Mustafa , Iyengar, Shruti Krishna , Srivathsan, Komandoor

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.14411 Get It

Background: Fasciculoventricular pathway (FVP) is a rare form of preexcitation without known clinical tachycardia. As it is connected to the His bundle, they conduct whenever it is engaged. Conduction through the His Bundle but block at FVP has not been reported. Case presentation: We present a case of a 42-year-old male with a history of Wolff-Parkinson-White syndrome (WPWS), supraventricular tachycardia (SVT), syncope, embolic stroke, paroxysmal atrial fibrillation, hypertension, hypothyroidism, Sjogren's syndrome and prior unsuccessful attempts at elimination of the preexcitation. He underwent electrophysiology (EP) study for presumed SVT ablation. The EP study identified an FVP as the cause of preexcitation, and the planned accessory pathway ablation was deemed unnecessary. Atrial tachycardia originating from the right superior pulmonary vein (PV) was induced, eventually degenerating into atrial fibrillation, and the patient successfully underwent pulmonary vein isolation with the resolution of symptoms. Discussion: FVP is usually an incidental finding when patients with symptomatic preexcitation are studied. If tachycardia is induced, it is unrelated to the preexcitation. The FVP is connected to the His bundle and invariably conducts if the impulse engages the His Bundle. We are unaware of a case when the His bundle conducts, but the impulse loses preexcitation due to a block in the FVP. This unusual finding was noted in our case. To further confirm the location of the accessory pathway, IV adenosine was given with a complete heart block suggesting the preexcitation is beyond the level of the AV node and within the conduction system. It is not at the annulus with independent atrial and ventricular insertion, typical of an accessory pathway. Conclusions: This case demonstrates an FV pathway's unusual conduction block and physiological characteristics.
Mortality trends, disparities, and social vulnerability in cardiac arrest mortality in the young: A cross‐sectional analysis
Shahid, Mahek, Sorajja, Dan , Deshmukh, Abhishek , Lee, Justin Z. , Deshmukh, Abhishek J , Ibrahim, Ramzi , Srivathsan, Komandoor

Mayo Clinic

Journal of Cardiovascular Electrophysiology | November 3, 2023 | Volume: 35 | Issue: 1 | Pages: 35-43

10.1111/jce.16112 | PMID 37921096 Get It

AbstractBackgroundCardiac arrest (CA) is a leading cause of death in the United States (US). Social determinants of health may impact CA outcomes. We aimed to assess mortality trends, disparities, and the influence of the social vulnerability index (SVI) on CA outcomes in the young.MethodsWe conducted a cross‐sectional analysis of age‐adjusted mortality rates (AAMRs) related to CA in the United States from the Years 1999 to 2020 in individuals aged 35 years and younger. Data were obtained from death certificates and analyzed using log‐linear regression models. We examined disparities in mortality rates based on demographic variables. We also explored the impact of the SVI on CA mortality.ResultsA total of 4792 CA deaths in the young were identified. Overall AAMR decreased from 0.20 in 1999 to 0.14 in 2020 with an average annual percentage change of −1.3% (p = .001). Black (AAMR: 0.30) and male populations (AAMR: 0.14) had higher AAMR compared with White (AAMR: 0.11) and female (AAMR: 0.11) populations, respectively. Nonmetropolitan (AAMR: 0.29) and Southern (AAMR: 0.26) regions were also impacted by higher AAMR compared with metropolitan (AAMR: 0.11) and other US census regions, respectively. A higher SVI was associated with greater mortality risks related to CA (risk ratio: 1.82 [95% CI, 1.77–1.87]).ConclusionsOur analysis of CA in the young revealed disparities based on demographics, with a decline in AAMR from 1999 to 2020. There is a correlation between a higher SVI and increased CA mortality risk, highlighting the importance of targeted interventions to address these disparities effectively.
Bad to worse: mitral regurgitation increases from moderate–severe to torrential following cardioversion to sinus rhythm
Shipman, Justin , Alsidawi, Said , Alsidawi, Said , Srivathsan, Komandoor

Mayo Clinic

European Heart Journal - Cardiovascular Imaging | October 7, 2023 | Volume: 25 | Issue: 1 | Pages: e63-e63

10.1093/ehjci/jead253 | PMID 37804530 Get It

Challenges of atrial fibrillation and atrial flutter ablation in patients with pectus excavatum
Iyengar, Sumedh , Reddy, Sudeepthi, Khetarpal, Banveet Kaur , Elzamar, Mohamed, Srivathsan, Komandoor

Mayo Clinic

Pacing and Clinical Electrophysiology | August 19, 2023 | Volume: 47 | Issue: 5 | Pages: 668-672

10.1111/pace.14805 | PMID 37594226 Get It

Abstract Atrial fibrillation (AF) may be associated with chest wall abnormalities such as pectus excavatum (PE). Pulmonary vein isolation (PVI) has proven to be a useful strategy for radiofrequency catheter ablation (RFCA) of AF. However, the presence of chest wall abnormalities, such as pectus excavatum, imposes certain challenges during ablation due to the anatomic distortion that it causes. We highlight these challenges during ablation in this three‐patient case series.
Adverse events in cryoballoon ablation for pulmonary vein isolation: Insight from the Food and Drug Administration Manufacturer and User Facility Device Experience
Tan, Min Choon , Tan, Jian Liang , Lee, Wei Jun , Sorajja, Dan , Masry, Hicham El , Scott, Luis R. , Lee, Justin Z. , El Masry, Hicham , Tan, Min C , Srivathsan, Komandoor

Mayo Clinic

Journal of Arrhythmia | July 24, 2023 | Volume: 39 | Issue: 5 | Pages: 784-789

10.1002/joa3.12898 | PMID 37799789 Get It

AbstractBackgroundReal‐world clinical data on the adverse events related to the use of cryoballoon catheter for pulmonary vein isolation remains limited.ObjectiveTo report and describe the adverse events related to the use of Artic Front cryoballoon catheters (Arctic Front, Arctic Front Advance, and Arctic Front Advance Pro) reported in the Food and Drug Administration's (FDA) Manufacturers and User Defined Experience (MAUDE) database.MethodsWe reviewed all the adverse events reported to the FDA MAUDE database over a 10.7‐year study period from January 01, 2011 to September 31, 2021. All events were independently reviewed by two physicians.ResultsDuring the study period, a total of 320 procedural‐related adverse events reported in the MAUDE database were identified. The most common adverse event was transient or persistent phrenic nerve palsy (PNP), accounting for 48% of all events. This was followed by cardiac perforation (15%), pulmonary vein stenosis (8%), transient ischemic attack or stroke (6%), vascular injury (4%), transient or persistent ST‐elevation myocardial infarction (3%), hemoptysis (2%), pericarditis (2%), and esophageal ulcer or fistula (1%). There were six reported intra‐procedural death events as a result of cardiac perforation.ConclusionThe two most common procedural adverse events associated with cryoballoon ablation were PNP and cardiac perforation. All cases of procedural mortality were due to cardiac perforation.
Abstract 9696: Long-Term Outcomes With Abandoning versus Extracting Sterile Leads: A 10-Year Population-Based Study
Talaei, Fahimeh , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Asirvatham, Samuel J. , Kusumoto, Fred , Lee, Justin

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.9696 Get It

Background: Long-term outcomes of lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) during cardiac implantable electronic devices (CIED) procedures requiring lead addition or replacement remain unclear. Hypothesis: We hypothesized that there is no difference in long-term (10-year) outcomes of LA versus TLE during CIED procedures requiring lead addition. Methods: We performed a retrospective cohort study of a population residing in seven adjacent counties of southeastern Minnesota with follow-up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE for sterile leads from January 1, 2000, to January 1, 2011, and had follow-up for at least 10-years or until their death were included. Outcomes were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system. Results: A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. In long-term follow-up, indications for subsequent lead extraction arose in 9.1% (n=14) of patients with initial LA and 5.3% (n=1) in patients with initial TLE, after an average of 7-years. Moreover, out of 14 patients, who required secondary extraction in the LA cohort, 28.6% did not proceed with the extraction. Of the remaining 10 patients, 60% had clinical success and 40% had a clinical failure with the extraction. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges such as requiring balloon venoplasty or serial dilation (5.2% vs. 5.3%, P=1.0). There was no difference in 10-year survival probability among LA group and TLE group (P=0.64). Conclusion: Indications for subsequent extraction arose in 9.1% of patients with the initial LA approach for sterile leads after an average of 7.3 years and 28.6% did not proceed with the extraction. Of the patients who underwent the subsequent extraction, 60% had clinical success and 40% had a clinical failure. There was no difference in 10-year survival probability between patients with the initial LA approach or TLE approach.
Abstract 10913: Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation
Deshmukh, Abhishek , Scott, Luis, Cha, Yong‐Mei , Mulpuru, Siva K. , Lee, Justin Z. , Tan, Min Choon , Rattanawong, Pattara , Srivathsan, Komandoor , McLeod, Christopher J. , Asirvatham, Samuel J. , Noseworthy, Peter A.

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10913 Get It

Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. Objective: This study sought to determine the causes of early mortality (≤90-days) after AF ablation and to further understand the circumstances surrounding death after the procedure. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6,723 patients were included in the study. The 30-day and 90-day all-cause mortality rates were 0.09% and 0.22%, respectively. Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06%. Most of the early deaths (93.3%) occurred after discharge from index hospitalization, among which 64.3% were readmitted before their death, 14% died at home, and 7% were discharged on comfort care and died in hospice. The main reason for readmission leading to death was respiratory failure (33%). Conclusion: Atrial fibrillation ablation procedure has a 90-day mortality of 0.22% and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was 0.06%.
Abstract 10571: Causes of Early Mortality After Catheter Ablation of Ventricular Tachycardia in Patients With Reduced Left Ventricular Ejection Fraction
Lee, Justin Z. , Deshmukh, Abhishek , Shen, Win K., Scott, Luis R. , Cha, Yong‐Mei , Mulpuru, Siva K. , Tan, Min Choon , Srivathsan, Komandoor , Masry, Hicham El , Asirvatham, Samuel J. , McLeod, Christopher J.

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10571 Get It

Background: Recognition of the causes of early mortality after ventricular tachycardia (VT) ablation in patients with reduced left ventricular ejection fraction is an essential step toward improving post-procedural outcomes. Objective: This study sought to determine the causes of early mortality (≤30-days) after VT ablation in patients with reduced left ventricular ejection fraction and to understand further the circumstances surrounding death after the procedure. Methods: We performed a retrospective analysis of all patients undergoing VT ablation in patients with reduced left ventricular ejection fraction from January 1, 2013, to November 10, 2021, at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a detailed chart review of the electronic health record within the Mayo Clinic system and outside records. Results: A total of 503 patients (mean age 63 ± 13 years, 11.2% female) with EF <50% were included in the study. The 30-day all-cause mortality rate was 5% (n=25), and the mortality rate due to a procedural complication was 0.4%. Among all 30-day deaths, recurrent VT was the most common primary cause of death (44%). This was followed by decompensated heart failure (28%), procedure-related death (8%), cerebrovascular accident (CVA) (4%), and infection (4%). Most patients (91%) who died from VT had the VT recurrence within three days of the ablation. 76% of patients with early mortality had delayed referral for VT ablation, and 72% opted for comfort care before death. Conclusions: The overall early mortality (≤30-days) rate after catheter ablation of VT in patients with reduced left ventricular ejection fraction was 5%, but the death rate directly due to a procedural complication was only 0.4%. The most common cause of death was recurrent VT, followed by heart failure. Further research into ablation strategies is vital to improving the safety, efficacy, and durability of VT ablation.
Abstract 10567: Sepsis-Related Early Mortality After Transvenous Lead Removal
Lee, Justin Z. , Deshmukh, Abhishek , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Friedman, Paul A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Kusumoto, Fred , Asirvatham, Samuel J.

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10567 Get It

Background: Recognition of the infectious characteristics among the sepsis-related early mortality after transvenous lead removal (TLR) is an essential step to improving patient outcomes. Objective: This study sought to understand the infectious characteristic and circumstances among the sepsis-related early mortality after TLR. Methods: We performed a retrospective analysis of all patients undergoing TLR from January 1, 2001, to January 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Patient details were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 2,319 patients were included in the study. The overall 30-day sepsis-related mortality rate was 1.25% (n=29). Among the sepsis-related deaths, 24 patients (83%) had systemic cardiac implantable electronic device (CIED) infection, and 4 patients (14%) initially had isolated pocket infection. The average time from admission to TLR was 11 days. MSSA was the most common organism (n=8, 28%), and this was followed by MRSA (n=4, 14%) and Candida (n=3, 10%). Twenty of these patients (69%) had vegetation on the echocardiogram: vegetation on lead only in 9 patients, vegetation on both valve and lead in 8 patients, and vegetation on valve only in 3 patients. Among valvular vegetations, 5 patients had tricuspid valve vegetations, 3 patients had aortic valve vegetations, 2 patients had mitral valve vegetations, and 1 patient had both mitral and aortic valve vegetation. The average size of vegetation was 1.3±0.8 x 1.1±0.6 cm. Conclusions: The 30-day sepsis-related mortality rate was 1.25%. Among the sepsis-related early deaths, MSSA was the most common organism, and more than two-thirds (69%) of the patients had vegetations on cardiac imaging. This highlights the importance of further research to improve the infection outcome in TLR patients.
Abstract 10559: Causes of Early Mortality After Transvenous Lead Removal
Lee, Justin Z. , Deshmukh, Abhishek , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Friedman, Paul A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Kusumoto, Fred , Asirvatham, Samuel J.

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10559 Get It

Background: Recognition of the causes of early mortality after transvenous lead removal (TLR) is an essential step for the development of quality improvement programs. Objective: This study sought to determine the causes of early mortality after TLR and to further understand the circumstances surrounding death after TLR. Methods: We performed a retrospective analysis of all patients undergoing TLR from January 1, 2001, to January 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system and outside records when available. The causes of death were further characterized based on whether it was related to the TLR procedure. Results: A total of 2,319 patients were included in the study. The overall 30-day all-cause mortality rate was 3%. Among all 30-day deaths, infection was the most common primary cause of death (42%). This was followed by decompensated heart failure (17%), procedure-related death (10%), sudden cardiac arrest (7%), and respiratory failure (6%). The 30-day mortality rate directly due to complications associated with the TLR procedure was 0.3% due to vascular tear and cardiac perforation. A third of deaths (33%) occurred after discharge from index hospitalization, among which 43% were readmitted before their death, 35% died at home or a nursing facility, and 22% were discharged on comfort care and died in hospice. The main reasons for readmission prior to death were sepsis and decompensated heart failure. Conclusions: The majority (90%) of 30-day mortality after TLR was not due to complications associated with TLR procedures. The primary causes were infection and decompensated heart failure. This highlights the importance of further research to reduce postoperative mortality from these factors, including deaths after hospital discharge.