Citations

Clear

32 citation(s) found for "Pandey, Aditya S".

The Hydrogel Endovascular Aneurysm Treatment Trial (HEAT): A Randomized Controlled Trial of the Second-Generation Hydrogel Coil
Bendok, Bernard R. , Abi-Aad, Karl R., Ward, Jennifer , Kniss, Jason F , Kwasny, Mary , Rahme, Rudy J. , Aoun, Salah G. , Tecle, Najib E. El , Zammar, Samer G. , Aoun, Rami James N. , Patra, Devi Prasad, Raymond, Jean , Woo, Henry H. , Dabus, Guilherme , Milot, Geneviève , Scott, John A. , DeNardo, Andrew , Investigators, HEAT Study, Lavine, Sean D., Bozorgchami, Hormozd, Veznedaroglu, Erol, Albuquerque, Felipe C. , Fiorella, David, Boulos, Alan S. , Cortes, Maria, Kanaan, Hilal, Jindal, Gaurav , Klucznik, Richard , Kalmes, David, Xavier, Andrew, Hussain, Muhammad , Moran, Christopher J. , Adel, Brian van , Milot, Genevieve, Hirsch, Joshua A , Carpenter, Jeffrey , Powers, Ciarán J. , Luh, George, Tummala, Ramanchandra, Evans, Avery J. , Garg, Ankur, James, Roberts, Sauvageau, Eric , Fields, Jeremy D. , Grobelny, Thomas, Hartman, J., Patra, Devi P. , Bendok, Bernard R , Ward, Jennifer D, Ahmadieh, Tarek Y. El , Ansari, Sameer A. , Fiorella, David , Dabus, Guilherme C. , Almandoz, Josser E Delgado , Dashti, Shervin R , Investigators, HEAT Study, Deshaies, Eric Michael , Fiorella, David, Tawk, Rabih G. , Romero, Charles, Kelly, Michael , Chaudry, Imran , Pandey, Aditya S , Wang, Dennis Y.Q. , Milot, Genevieve, Jabbour, Pascal , Shankar, Jai , Patsalides, Athos T , Lee, Sung , James, Robert F. , Jayaraman, Mahesh V. , Satti, Sudhakar R

Mayo Clinic

Neurosurgery | February 10, 2020 | Volume: 86 | Issue: 5 | Pages: 615-624

10.1093/neuros/nyaa006 | PMID 32078692 Get It

Abstract BACKGROUND Aneurysm recurrence after coiling has been associated with aneurysm growth, (re)hemorrhage, and a greater need for follow-up. The second-generation HydroCoil Embolic System (HES; MicroVention, Inc) consists of a platinum core with integrated hydrogel and was developed to reduce recurrence through enhancing packing density and healing within the aneurysm. OBJECTIVE To compare recurrence between the second-generation HES and bare platinum coil (BPC) in the new-generation Hydrogel Endovascular Aneurysm Treatment Trial (HEAT). METHODS HEAT is a randomized, controlled trial that enrolled subjects with ruptured or unruptured 3- to 14-mm intracranial aneurysms amenable to coiling. The primary endpoint was aneurysm recurrence using the Raymond-Roy scale. Secondary endpoints included minor and major recurrence, packing density, adverse events related to the procedure and/or device, mortality, initial complete occlusion, aneurysm retreatment, hemorrhage from target aneurysm during follow-up, aneurysm occlusion stability, and clinical outcome at final follow-up. RESULTS A total of 600 patients were randomized (HES, n = 297 and BPC, n = 303), including 28% with ruptured aneurysms. Recurrence occurred in 11 (4.4%) subjects in the HES arm and 44 (15.4%) subjects in the BPC arm ( P = .002). While the initial occlusion rate was higher with BPC, the packing density and both major and minor recurrence rates were in favor of HES. Secondary endpoints including adverse events, retreatment, hemorrhage, mortality, and clinical outcome did not differ between arms. CONCLUSION Coiling of small-to-medium aneurysms with second-generation HES resulted in less recurrence when compared to BPC, without increased harm. These data further support the use of the second-generation HES for the embolization of intracranial aneurysms. Video Abstract
Gastrostomy tube placement increases the risk of ventriculoperitoneal shunt infection: a multiinstitutional study
Al‐Holou, Wajd N. , Wilson, Thomas J. , Ali, Zarina S. , Brennan, Ryan P., Bridges, Kelly J., Guivatchian, Tannaz, Habboub, Ghaith , Krishnaney, Ajit A., Snyder, Kendall, Than, Khoi D. , Snyder, Kendall A, Al-Holou, Wajd N , Lanzino, Giuseppe , Flanders, Tracy M. , Pandey, Aditya S

Mayo Clinic

Journal of Neurosurgery | February 27, 2019 | Volume: 131 | Issue: 4 | Pages: 1062-1067

10.3171/2018.5.jns18506 | PMID 30497165 Get It

OBJECTIVEGastrostomy tube placement can temporarily seed the peritoneal cavity with bacteria and thus theoretically increases the risk of shunt infection when the two procedures are performed contemporaneously. The authors hypothesized that gastrostomy tube placement would not increase the risk of ventriculoperitoneal shunt infection. The object of this study was to test this hypothesis by utilizing a large patient cohort combined from multiple institutions.METHODSA retrospective study of all adult patients admitted to five institutions with a diagnosis of aneurysmal subarachnoid hemorrhage between January 2005 and January 2015 was performed. The primary outcome of interest was ventriculoperitoneal shunt infection. Variables, including gastrostomy tube placement, were tested for their association with this outcome. Standard statistical methods were utilized.RESULTSThe overall cohort consisted of 432 patients, 47% of whom had undergone placement of a gastrostomy tube. The overall shunt infection rate was 9%. The only variable that predicted shunt infection was gastrostomy tube placement (p = 0.03, OR 2.09, 95% CI 1.07–4.08), which remained significant in the multivariate analysis (p = 0.04, OR 2.03, 95% CI 1.04–3.97). The greatest proportion of shunts that became infected had been placed more than 2 weeks (25%) and 1–2 weeks (18%) prior to gastrostomy tube placement, but the temporal relationship between shunt and gastrostomy was not a significant predictor of shunt infection.CONCLUSIONSGastrostomy tube placement significantly increases the risk of ventriculoperitoneal shunt infection.