Citations

Showing 10 of 108083 citations.

Patterns of Health Portal Use by Regular Portal Users Among Patients With Cancer: Results From the UWCCC Survivorship Program
Emamekhoo, Hamid , Chandereng, Thevaa , Sesto, Mary E. , Luoh, Rebecca P., Bergeson, Elena M., Carroll, Cibele Barbosa , Tevaarwerk, Amyé , Carroll, Cibele B , Tevaarwerk, Amye J , Emamekhoo, Hamid

Mayo Clinic

JCO Clinical Cancer Informatics | January 13, 2023 | Volume: No volume available | Issue: 7 | Pages: No page available

10.1200/cci.22.00119 | PMID 36638325 Get It

PURPOSE We sought to evaluate the patterns of portal usage among patients with cancer who regularly log in to the portal. These data will inform approaches to facilitate portal use among patients with cancer. PATIENTS AND METHODS We conducted a retrospective analysis of patient portal usage by patients with cancer at the University of Wisconsin Carbone Cancer Center. Our analysis focuses on patterns of portal use by regular users (≥ 2 portal logins/year, > 3 months) receiving ongoing oncology care between January 1, 2017, and December 31, 2019. Demographics, cancer characteristics, number of oncology visits per month, and portal usage data were extracted. Regular portal users were grouped and compared on the basis of their frequency of use. A linear mixed-effects model was used to determine if the frequency of oncology visits influenced the number of logins. RESULTS We identified 2076 regular portal users. The median number of portal logins/year was 72 for the entire cohort. Age and race were associated with frequency of portal logins. There was no difference in frequency of portal login on the basis of cancer type or stage. Each additional oncology office visit in a month increased the frequency of portal logins by 3.05 ± 0.11 (SE) within the same month. Messages and test result functionalities were used by 98.7% and 98.9% of the regular users, respectively. Regular users who logged in to portal more frequently used all five studied portal functionalities. CONCLUSION Patients with cancer who use portals regularly use it more in proximity to an oncology office visit and use multiple available portal functionalities. These findings can direct strategic planning to facilitate portal utilization among those not engaged with this tool.
Outcome and safety of intraoperative defibrillation testing during device replacement: the Simpler trial
Nof, Eyal , Rav, Moshe , Beinart, Roy, Kutyifa, Valentina , Regev, Ehud , Biffi, Mauro , Cha, Yong‐Mei , Ovdat, Tal , Klempfner, Robert , Glikson, Michael , Goldenberg, Ilan , Milman, Anat , Rav Acha, Moshe , Beinart, Roy , Kutyifa, Valentina , Merkely, Béla , Regev, Ehud , Biffi, Mauro , Cha, Yong-Mei , Ovdat, Tal , Glikson, Michael

Mayo Clinic

EP Europace | January 13, 2023 | Volume: 25 | Issue: 3 | Pages: 956-960

10.1093/europace/euac282 | PMID 36636968 Get It

AbstractAimsIntraoperative defibrillation testing (DT) during implant or replacement of implantable cardioverter-defibrillators (ICDs) has been a matter of debate for many years. This debate was put to rest by the Simple and Nordic ICD trials, and the practice of testing during new implantations has essentially been almost abandoned. Old registries demonstrated an increased incidence of significant findings in DT during replacements. The aim of the present study was to evaluate frequency of significant findings and safety of DT in subjects undergoing device replacement.Methods and resultsA prospective observational multi-centre study included consecutive patients undergoing ICD generator replacement. The primary outcome was a failure to terminate induced ventricular fibrillation (VF) with a single shock 10 J below the maximal capacity of the device. Secondary outcomes included complications of DT. Patients were followed-up at 1- and 6-months post-procedure. A total of 92 patients were eligible, and consented to the study, of which 84 underwent DT during battery replacement. The median age was 68 years and 79.8% were males. Induction of VF was successful in 84 patients as was a successful conversion on the first attempt in all. There were no procedure-related complications. During follow up one patient had two appropriate ICD shock events. In four patients, ICD programming was changed. None suffered inappropriate shock. There was no evidence of lead malfunction. Two deaths occurred, none of which was related to arrhythmia.ConclusionThe present study found DT was not associated with complications in patients undergoing ICD generator replacement but produced no clinically important information.
Cardiac troponin measurement at the point of care: educational recommendations on analytical and clinical aspects by the IFCC Committee on Clinical Applications of Cardiac Bio-Markers (IFCC C-CB)
Aakre, Kristin M. , Saenger, Amy K., Body, Rick, Hammarsten, Ole, Jaffe, Allan S. , Kavsak, Peter A. , Omland, Torbjørn , Ordonez-Lianos, Jordi, Karon, Brad S. , Apple, Fred S. , Aakre, Kristin M , Karon, Brad, Collinson, Paul , Body, Rick, Jaffe, Allan S.

Mayo Clinic

Clinical Chemistry and Laboratory Medicine (CCLM) | January 13, 2023 | Volume: 61 | Issue: 6 | Pages: 989-998

10.1515/cclm-2022-1270 | PMID 36637984 Get It

Abstract The International Federation of Clinical Chemistry and Laboarator Medicine (IFCC) Committee on Clinical Applications of Cardiac Bio-Markers (C-CB) has provided evidence-based educational resources to aid and improve the understanding of important analytical and clinical aspects of cardiac biomarkers. The present IFCC C-CB educational report focuses on recommendations for appropriate use, analytical performance, and gaps in clinical studies related to the use of cardiac troponin (cTn) by point of care (POC) measurement, often referred to as a point of care testing (POCT). The use of high-sensitivity (hs)-cTn POC devices in accelerated diagnostic protocols used in emergency departments or outpatient clinics investigating acute coronary syndrome has the potential for improved efficacy, reduction of length of stay and reduced costs in the health care system. POCT workflow integration includes location of the instrument, assignment of collection and testing responsibility to (non-lab) staff, instrument maintenance, in-service and recurrent training, quality control, proficiency assessments, discrepant result trapping, and troubleshooting and inventory management.
Predicting 30-day all-cause hospital readmission using multimodal spatiotemporal graph neural networks
Tang, Siyi , Tariq, Amara , Dunnmon, Jared , Elugunti, Praneetha, Rubin, Daniel L. , Patel, Bhavik N. , Banerjee, Imon , Banerjee, Imon , Rubin, Daniel L , Sharma, Umesh

Mayo Clinic

IEEE Journal of Biomedical and Health Informatics | January 13, 2023 | Volume: No volume available | Issue: No issue available | Pages: 1-12

10.1109/jbhi.2023.3236888 | PMID 37018684 Get It

Commentary: En Bloc Resection of a Cauda Equina Paraganglioma and Associated Intradural Hematoma After Diagnosis of Renal Clear Cell Carcinoma: 2-Dimensional Operative Video
Stonnington, Henry O. , Olson, Vita A. , Kalani, Maziyar A. , Krishna, Chandan , Patel, Naresh P. , Bendok, Bernard R.

Mayo Clinic

Operative Neurosurgery | January 13, 2023 | Volume: 24 | Issue: 2 | Pages: e144-e145

10.1227/ons.0000000000000550 | PMID 36637329 Get It

International Learner Perceptions, Educational Value, and Cost Associated With the Use of Start-to-Finish Surgical Simulation Compared With Cadaveric Models
Damon, Aaron , Pichelmann, Mark A., Nottmeier, Eric W. , CreveCoeur, Travis S. , Lee, Seung-Jin, Pichelmann, Mark, Nottmeier, Eric, Lee, Seung Jin , Clifton, William

Mayo Clinic

Operative Neurosurgery | January 13, 2023 | Volume: 24 | Issue: 2 | Pages: 201-208

10.1227/ons.0000000000000475 | PMID 36637305 Get It

BACKGROUND: Graduate surgical education is highly variable across regions and institutions regarding case volume and degree of trainee participation in each case. Dedicated educational curriculum using cadaveric tissue has been shown to enhance graduate surgical training, however with associated financial and utility burden to the institution. OBJECTIVE: To investigate the utility of educational and cost applications of a novel method of combining mixed organic hydrogel polymers and 3-dimensional printed anatomic structures to create a complete “start-to-finish” simulation for resident education in spinal anatomy, instrumentation, and surgical techniques. METHODS: This qualitative pilot study investigated 14 international participants on achievement of objective and personal learning goals in a standardized curriculum using biomimetic simulation compared with cadaveric tissue. A questionnaire was developed to examine trainee evaluation of individual anatomic components of the biomimetic simulators compared with previous experience with cadaveric tissue. RESULTS: A total of 210 responses were acquired from 14 participants. Six participants originated from US residency education programs and 8 from transcontinental residency programs. Survey results for the simulation session revealed high user satisfaction. Score averages for each portion of the simulation session indicated learner validation of anatomic features for the simulation compared with previous cadaveric experience. Cost analysis resulted in an estimated savings of $10 833.00 for this single simulation session compared with previous cadaveric tissue sessions. CONCLUSION: The results of this study indicate a strong potential of establishing biomimetic simulation as a cost-effective and high-quality alternative to cadaveric tissue for the instruction of fundamental spine surgical techniques.
Commentary: Physiological Responses and Training Satisfaction During National Rollout of a Neurosurgical Intraoperative Catastrophe Simulator for Resident Training
Bouchal, Samantha M. , Meyer, Jenna H., Bouchal, Samantha M , Bendok, Bernard R.

Mayo Clinic

Operative Neurosurgery | January 13, 2023 | Volume: 24 | Issue: 2 | Pages: e139-e141

10.1227/ons.0000000000000548 | PMID 36637327 Get It

Awake Microsurgical Resection of a Motor Cortex Glioma With Cortical and Subcortical Motor Mapping, Image Guidance, and Augmented Reality: 2-Dimensional Operative Video
Turcotte, Evelyn L. , Jones, Breck A., Chhabra, Nikita, Porter, Alyx B. , Donev, Kliment , Hu, Leland , Bendok, Bernard R. , Bendok, Bernard R

Mayo Clinic

Operative Neurosurgery | January 13, 2023 | Volume: 24 | Issue: 2 | Pages: e122-e122

10.1227/ons.0000000000000525 | PMID 36637320 Get It

Surgical Decompression of Traumatic Cervical Spinal Cord Injury: A Pilot Study Comparing Real-Time Intraoperative Ultrasound After Laminectomy With Postoperative MRI and CT Myelography
Chryssikos, Timothy , Stokum, Jesse A. , Ahmed, Abdul-Kareem , Wessell, Aaron , Cannarsa, Gregory , Caffes, Nicholas, Oliver, Jeffrey , Olexa, Joshua , Shea, Phelan, Labib, Mohamed, Woodworth, Graeme F., Ksendzovsky, Alexander , Bodanapally, Uttam K. , Crandall, Kenneth M. , Sansur, Charles A. , Schwartzbauer, Gary , Aarabi, Bizhan , Woodworth, Graeme F , Chen, Chixiang

Mayo Clinic

Neurosurgery | January 13, 2023 | Volume: 92 | Issue: 2 | Pages: 353-362

10.1227/neu.0000000000002207 | PMID 36637270 Get It

BACKGROUND: Decompression of the injured spinal cord confers neuroprotection. Compared with timing of surgery, verification of surgical decompression is understudied. OBJECTIVE: To compare the judgment of cervical spinal cord decompression using real-time intraoperative ultrasound (IOUS) following laminectomy with postoperative MRI and CT myelography. METHODS: Fifty-one patients were retrospectively reviewed. Completeness of decompression was evaluated by real-time IOUS and compared with postoperative MRI (47 cases) and CT myelography (4 cases). RESULTS: Five cases (9.8%) underwent additional laminectomy after initial IOUS evaluation to yield a final judgment of adequate decompression using IOUS in all 51 cases (100%). Postoperative MRI/CT myelography showed adequate decompression in 43 cases (84.31%). Six cases had insufficient bony decompression, of which 3 (50%) had cerebrospinal fluid effacement at >1 level. Two cases had severe circumferential intradural swelling despite adequate bony decompression. Between groups with and without adequate decompression on postoperative MRI/CT myelography, there were significant differences for American Spinal Injury Association motor score, American Spinal Injury Association Impairment Scale grade, AO Spine injury morphology, and intramedullary lesion length (IMLL). Multivariate analysis using stepwise variable selection and logistic regression showed that preoperative IMLL was the most significant predictor of inadequate decompression on postoperative imaging ( P = .024). CONCLUSION: Patients with severe clinical injury and large IMLL were more likely to have inadequate decompression on postoperative MRI/CT myelography. IOUS can serve as a supplement to postoperative MRI/CT myelography for the assessment of spinal cord decompression. However, further investigation, additional surgeon experience, and anticipation of prolonged swelling after surgery are required.