Citations

Showing 10 of 108081 citations.

Limitations of the Caputo time-fractional wave equation when applied to shear waves in pig liver
McGough, Robert J., Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A312-A312

10.1121/10.0018969 Get It

When applied to compressional waves, the Caputo time-fractional wave equation describes power law attenuation in soft tissue. However, when applied to shear waves, the Caputo wave equation produces some unexpected behavior. To demonstrate examples of the time-domain waveforms generated by this fractional calculus model, the Caputo wave equation is numerically evaluated for multiple orders of the time-fractional derivative between 0 and 1, for an extended range of values for the relaxation time, and for a fixed value of the shear wave speed extracted from ex vivo pig liver. The computed waveforms are then compared to the measured shear wave particle velocities obtained from ex vivo pig liver. These comparisons reveal that the full-width at half maximum (FWHM) of the positive component of the main shear wave particle velocity waveform measured in pig liver is at least an order of magnitude greater than the FWHM obtained from the Caputo wave equation for all parameter combinations evaluated. These preliminary results indicate that the Caputo wave equation produces time-domain waveforms that are inconsistent with measured shear wave data in pig liver and that further efforts are required to establish more effective fractional calculus models for shear waves in soft tissue.
Parametric evaluation of Kelvin-Voigt dispersion curve fitting
Vasconcelos, Luiz, Kijanka, Piotr , Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A313-A313

10.1121/10.0018970 Get It

Ultrasound shear wave elastography (SWE) is a useful technique for non-invasive tissue assessment. For effective quantitative analysis the employment of physical models is necessary for rheological parameter estimation, such as the Kelvin-Voigt (KV) model. From SWE data, the frequency response can be calculated, and the shear wave velocity dispersion can be fit, yielding the shear elasticity and shear viscosity, μ1 and μ2, respectively. In this study, a parametric evaluation is performed using staggered-grid finite-difference simulations of materials with μ1 = 1–25 kPa (increment: 1 kPa) and μ2 = 0–10 Pa s (increment: 0.5 Pa s), with an acoustic radiation force push of f-number equal to 2. The novel Stockwell transform combined with a slant frequency-wavenumber analysis (GST-SFK) was compared with the two-dimensional Fourier transform for dispersion curve estimation over a variety of frequency ranges. Regardless of dispersion curve estimation technique, the accuracy of estimating μ1 is confounded for μ2 values above 5 Pa s. It was found that KV fitting benefits from wider frequency ranges (up to 1kHz), with lower μ1 and μ2 estimation errors. The GST-SFK was the best dispersion curve calculation technique, yet the KV fitting process was found to be unreliable for parameter estimation in highly viscous media.
Nonlinear least-squares estimation of shear modulus and shear viscosity in viscoelastic media
Bannon, Nicholas A., McGough, Robert J., Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A313-A313

10.1121/10.0018971 Get It

Time-domain estimates of the shear wave speed are obtained by performing cross-correlations or by evaluating the time-to-peak for two laterally separated shear wave particle velocity waveforms, where the distance divided by the propagation time yields an approximate value for the shear wave speed. Challenges associated with these time-domain estimation approaches include increasing errors as the shear viscosity increases and the absence of an estimated value for the shear viscosity parameter which is responsible for the rapid attenuation of shear waves in soft tissue. To obtain a time-domain estimate of the shear viscosity that also provides an estimate for the shear wave speed, a nonlinear least squares estimation approach is applied to three-dimensional (3D) shear wave particle velocities computed for a shear elasticity of 1.5 kPa, shear viscosities of 1, 2, 3, and 4 Pa.s, and a realistic simulated 3D acoustic radiation force excitation. The results show cross-correlations tend to over-estimate the value of the shear wave speed, the nonlinear least squares approach tends to under-estimate the value of the shear wave speed, and the nonlinear least square approach produces more accurate estimates as the shear viscosity increases. Two-dimensional maps of each estimated parameter are also shown.
Stress Echo 2030: the new ABCDE protocol defining the future of cardiac imaging
Picano, Eugenio , Cortigiani, Lauro , Bartolacelli, Ylenia , Kane, Garvan C. , Pellikka, Patricia, Ciampi, Quirino , Arbucci, Rosina , Zagatina, A , Čelutkienė, Jelena , Lowenstein, Jorge , Pellikka, Patricia A.

Mayo Clinic

European Heart Journal Supplements | April 26, 2023 | Volume: 25 | Issue: Supplement_C | Pages: C63-C67

10.1093/eurheartjsupp/suad008 | PMID 37125276 Get It

Abstract Functional testing with stress echocardiography is based on the detection of regional wall motion abnormality with two-dimensional echocardiography and is embedded in clinical guidelines. Yet, it under-uses the unique versatility of the technique, ideally suited to describe the different functional abnormalities underlying the same wall motion response during stress. Five parameters converge conceptually and methodologically in the state-of-the-art ABCDE protocol, assessing multiple vulnerabilities of the ischemic patient. The five steps of the ABCDE protocol are (1) step A: regional wall motion; (2) step B: B-lines by lung ultrasound assessing extravascular lung water; (3) step C: left ventricular contractile reserve by volumetric two-dimensional echocardiography; (4) step D: coronary flow velocity reserve in mid-distal left anterior descending coronary with pulsed-wave Doppler; and (5) step E: assessment of heart rate reserve with a one-lead electrocardiogram. ABCDE stress echo offers insight into five functional reserves: epicardial flow (A); diastolic (B), contractile (C), coronary microcirculatory (D), and chronotropic reserve (E). The new format is more comprehensive and allows better functional characterization, risk stratification, and personalized tailoring of therapy. ABCDE protocol is an ‘ecumenic’ and ‘omnivorous’ functional test, suitable for all stresses and all patients also beyond coronary artery disease. It fits the need for sustainability of the current era in healthcare, since it requires universally available technology, and is low-cost, radiation-free, and nearly carbon-neutral.
Shear wave elastography: From dispersion matching to full waveform inversion
Guddati, Murthy N. , Elmeliegy, Abdelrahman , Roy, Tuhin, Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A265-A265

10.1121/10.0018796 Get It

Shear Wave Elastography (SWE) involves estimating mechanical properties through inversion, i.e., matching measured and simulated propagation characteristics of shear waves in the tissue. The accuracy of the estimated properties depends significantly on the specific characteristics/responses that are being matched. These could range from simple group velocity to dispersion curves and to full-wave response (particle velocity measurements). Using specific applications of arterial, liver, and tumor elstography, we illustrate that effective SWE is performed by resorting to an inversion approach, or combination of inversion approaches, guided by the underlying physics. To this end, we present inversion approaches ranging from matching dispersion characteristics to matching full waveform responses and provide rationale for choosing the appropriate technique(s) depending on the problem at hand.
Improving group velocity based estimates of arterial stiffness
Capron, Charles , Guddati, Murthy N. , Roy, Tuhin, Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A266-A266

10.1121/10.0018801 Get It

Arterial stiffness is a predictor of cardiovascular diseases, the leading causes of death worldwide. Ultrasound-based methods that measure arterial wave propagation have promise for evaluating local stiffness in vivo. However, geometric properties of arteries cause dispersion, invalidating typical assumptions underlying the relationship between shear modulus G and group velocity cg, which clinical implementations of ultrasound shear wave elastography do not consider. Here, we examine the dependence of these estimates on geometry and evaluate alternative approaches. Wave motion in the proximal wall of an artery after application of focused acoustic radiation force is simulated with a semi-analytical finite element (SAFE) model, and cg is estimated using a time-to-peak algorithm to determine G with several methods. First, the value of G a clinical scanner would report is calculated assuming a bulk medium. Second, a pulse wave velocity (PWV)-based G estimate is calculated by taking cg = PWV and applying the Moens–Korteweg equation. Third, we develop an interpolation-based method to provide a corrected G estimate using data generated by the SAFE model. Simulation results show severe geometry-dependent bias with the bulk method, which is partially ameliorated with the PWV method and substantially improved with the interpolation approach. Results are validated using arterial phantoms.
Crosstalk analysis of comb detection for measuring shear wave propagation
Lee, Hyungkyi, Holmes, Philip M. , Greenleaf, James F. , Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A266-A266

10.1121/10.0018802 Get It

Applications, such as shear wave elastography and Doppler imaging, require high frame rates. Plane wave compounding (PWC) is widely used for these applications. Comb detection was proposed to combine the high frame rate of PWC and the high signal quality of focused beam scanning. Comb detection transmits multiple focused beams simultaneously to increase the frame rate. These comb beams are scanned laterally to cover the whole region-of-interest. The simultaneous multiple transmission of focused beams causes crosstalk between neighboring beams. Transmit crosstalk is related to the pressure field of transmit beams, and receive crosstalk is determined by the beam profile of receive beamforming. In this study, we varied f-number (F/N) and apodization window and measured their effects on crosstalk based on the pressure field and an arterial wall simulation using Field II. For transmit design, transmit apodization with a Hamming window significantly reduced crosstalk compared to a rectangular window and transmit F/N had little impact on the crosstalk. Regarding receive beamforming, a Hamming window led to lower crosstalk than the rectangular window and F/N from 1 to 5 suppressed crosstalk to below 30 dB. The effects of crosstalk in shear wave motion data from phantom experiments were also analyzed. Comb detection showed less motion artifact than PWC in phantom experiments.
Athletes With Attention-Deficit/Hyperactivity Disorder: Position Statement of the American Medical Society for Sports Medicine
Narducci, Dusty Marie , Smith, Michael S. , King, Rebecca L. , Logan, Kelsey , Callender, Shelley Street, Liebman, Catherine, Israel, Michael, Wolf, Sigrid F. , Nuti, Rathna , Khodaee, Morteza , Pujalte, George , Kane, Shawn F.

Mayo Clinic

Clinical Journal of Sport Medicine | April 26, 2023 | Volume: 33 | Issue: 3 | Pages: 195-208

10.1097/jsm.0000000000001152 | PMID 37185161 Get It

Abstract: Athletes of all ages may be affected by medical and mental health issues. Sports medicine physicians should be familiar with common conditions that may affect the well-being of athletes, such as attention-deficit/hyperactivity disorder (ADHD). ADHD behaviors have the potential to affect a person's ability to concentrate. It is likely that social and cognitive therapies combined with pharmacotherapy will be the most effective way to treat ADHD in athletes. Medications used for ADHD, especially stimulant types, are known to improve alertness, reaction time, anaerobic performance, and endurance, which would potentially improve athletic performance. Furthermore, stimulant medications may enable student athletes with ADHD to focus on academic studies for longer periods of time, beyond usual levels of fatigue, important for those who may be exhausted after practices and games. The purported performance enhancement effects and potential adverse effects of stimulant medications have prompted many sports governing bodies to ban prescription stimulants or establish strict rules for their use. Athletes taking physician-prescribed stimulants to treat ADHD need to provide the appropriate documentation for approval before competition or risk punitive measures. Physicians should strive to provide a high quality of care to athletes with ADHD through early diagnosis, appropriate and careful multidisciplinary treatment, and complete and timely documentation to facilitate continued sports participation.
Recent developments regarding the 15 dB improvement in SNR in noise available from four talkers in noise with wireless signals provided by simple clip-on-collar Companion Mics Remote Microphones
Killion, Mead C., Dunn, F G, Cevette, Michael J. , Haapapuro, Andrew, Dunn, Frank, Haapapuro, Andrew J.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A38-A38

10.1121/10.0018068 Get It

The Companion Mics® (CMICS™) by Etymotic Research, and more recently by the author’ company MCK Audio, have frequently demonstrated a 10–20 dB improvement in SNR in noisy groups and restaurants for up to four talkers, each of whom wears a CMIC wireless microphone unit on the collar or held near the chin. Until recently, however, the listener would need to wear an earphone. (Experimentally, two ears listening to the same signal provide only a 2 dB advantage.) The disadvantage was that the hearing aid audiologist would have to say: “If you have trouble in noise, take off your hearing aids and put on these earphones.” While waiting for the incorporation of Bluetooth circuits, two other successful alternates have been introduced. The first is an open-ear HearHook© sound tube which hooks over the ear and delivers sound near the earcanal, which is also near the microphone of a hearing aid. The second is the use of a neckloop connected to the CMIC, with the hearing aid switched to “tcoil” mode. An amplified tcoil HHearbud with built-in hum filter allows that use even when electrical hum interference is present.
Optimization of synthetic aperture delay-multiply-and-sum reconstruction
Holmes, Philip M. , Lee, Hyungkyi, Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A241-A241

10.1121/10.0018772 Get It

Synthetic aperture (SA) acquisition allows for focusing at all points in ultrasound images during reconstruction. Both delay-and-sum (DAS) and delay-multiply-and-sum (DMAS) have been used to reconstruct SA images. An integral part of both algorithms is the aperture size used to define the beam shape with the f-number. Although f-number variation has been studied in DAS reconstruction, there has not been a systematic study on this topic for DMAS reconstruction in SA imaging. In this work, we evaluated the effects of f-number in DMAS reconstruction using an imaging phantom (CIRS 040GSE). We reconstructed DAS and DMAS images of hyperechoic, hypoechoic, and anechoic contrast targets, as well as point targets, while varying the transmit and receive f-numbers between 0 and 7 in 0.2 increments. Generalized contrast-to-noise ratio (gCNR) was measured for contrast targets. The full width at half maximum (FWHM) was evaluated using point targets. When imaging contrast targets, the DAS and DMAS algorithms responded very differently when varying the f-numbers. DMAS produced higher gCNR values with low transmit f-numbers and high receive f-numbers, while DAS produced higher gCNR values with high transmit and receive f-numbers. When evaluating FWHM, the optimal receive f-number was close to 1 for both algorithms.